Zhigen Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhigen Wu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Dan Zhou
School of Transportation and Vehicle Engineering, Shandong University of Technology, Zibo, China
3 shared publicationsMaohui Luo
School of Mechanical Engineering, Tongji University, Shanghai 201804, China
1 shared publicationPengyuan Fan
Faculty of Land Resources Engineering, Kunming University of Science and Technology, Kunming, China
1 shared publicationQinghong Zhang
School of Transportation and Vehicle Engineering, Shandong University of Technology, Zibo 255000, China
1 shared publicationQingqing Wang
State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China
1 shared publication- Rong Xu
Centre for Environmental Risk Management and Remediation of Soil and Groundwater, Tongji University, Shanghai 200092, China
1 shared publication
Latest Publications
- Open Access
Benzo[a]pyrene (B[a]P) Degradation Enhanced by Soils Mixing Effects: Validation Study of Stirring Test and Discrete Element Method (DEM)
To date, few studies have been carried out on the influence of the mixing effects of soils and remediation agents on the remediation effects of benzo[a]pyrene (B[a]P) in contaminated soils. In this study, the mixing effects of soils and remediation agents and the degradation effects of B[a]P under different stirring conditions were investigated by combining stirring tests with discrete element method (DEM) simulation. The results from the stirring tests indicated that the mixing effects of two-stage (CDrill) drill bits were better than first-stage one-line (ADrill) and first-stage cruciform (BDrill) drill bits. The mixing quality of CDrill at the drilling/raising rates of 2, 2.5, 3, 4, and 7.5 cm/min were 42.13%, 43.20%, 43.98%, and 43.30%, respectively. In terms of the results from the B[a]P oxidation remediation tests, the contaminated soils mixed with CDril have better remediation effects for B[a]p than those mixed with ADril and BDril, since B[a]p in contaminated soils stirred and mixed using CDrill could not be detected after oxidative degradation. The present study results have proved that the mixing effects of soils and remediation agents could significantly affect the remediation effects of contaminated soils with polycyclic aromatic hydrocarbons (PAHs).
Open AccessBenzo[a]pyrene (B[a]P) Degradation Enhanced by Soils Mixing Effects: Validation Study of Stirring Test and Discrete Element Method (DEM)
To date, few studies have been carried out on the influence of the mixing effects of soils and remediation agents on the remediation effects of benzo[a]pyrene (B[a]P) in contaminated soils. In this study, the mixing effects of soils and remediation agents and the degradation effects of B[a]P under different stirring conditions were investigated by combining stirring tests with discrete element method (DEM) simulation. The results from the stirring tests indicated that the mixing effects of two-stage (CDrill) drill bits were better than first-stage one-line (ADrill) and first-stage cruciform (BDrill) drill bits. The mixing quality of CDrill at the drilling/raising rates of 2, 2.5, 3, 4, and 7.5 cm/min were 42.13%, 43.20%, 43.98%, and 43.30%, respectively. In terms of the results from the B[a]P oxidation remediation tests, the contaminated soils mixed with CDril have better remediation effects for B[a]p than those mixed with ADril and BDril, since B[a]p in contaminated soils stirred and mixed using CDrill could not be detected after oxidative degradation. The present study results have proved that the mixing effects of soils and remediation agents could significantly affect the remediation effects of contaminated soils with polycyclic aromatic hydrocarbons (PAHs).
- Open Access
Analytical Solution of Thermal Performance in Metal Foam Partially Filled Channel with Asymmetric Wall Heat Flux
An analytical solution is conducted on forced convection in a metal foam partially filled plate channel under asymmetric heat flux conditions, with the aim of optimizing heat transfer performance. The Darcy–Brinkman model and the local thermal non-equilibrium (LTNE) model are employed to predict heat transfer characteristics under varying heat flux ratios (q1/q2). Key parameters such as the free zone height, pore density, and thermal conductivity ratio significantly influence heat transfer efficiency. The results indicate that the height of the free region has a greater impact on the flow distribution than porosity and pore density. When the non-dimensional height of the free region is 0.3, the flow fraction in the free region reaches 80%. When the free zone height is H = 0.1, the heat exchanger heat transfer coefficient reaches its maximum value, and the combination of copper (Cu) and R134a refrigerant demonstrates superior convective heat transfer performance compared to the empty channel. Their optimization can lead to substantial improvements in the heat transfer effectiveness of the channel.
Open AccessAnalytical Solution of Thermal Performance in Metal Foam Partially Filled Channel with Asymmetric Wall Heat Flux
An analytical solution is conducted on forced convection in a metal foam partially filled plate channel under asymmetric heat flux conditions, with the aim of optimizing heat transfer performance. The Darcy–Brinkman model and the local thermal non-equilibrium (LTNE) model are employed to predict heat transfer characteristics under varying heat flux ratios (q1/q2). Key parameters such as the free zone height, pore density, and thermal conductivity ratio significantly influence heat transfer efficiency. The results indicate that the height of the free region has a greater impact on the flow distribution than porosity and pore density. When the non-dimensional height of the free region is 0.3, the flow fraction in the free region reaches 80%. When the free zone height is H = 0.1, the heat exchanger heat transfer coefficient reaches its maximum value, and the combination of copper (Cu) and R134a refrigerant demonstrates superior convective heat transfer performance compared to the empty channel. Their optimization can lead to substantial improvements in the heat transfer effectiveness of the channel.
- 29 November 2023
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 33 (24) , 13843-13854
Investigation on Corrosion Behaviors of Ternary Nitrate Molten Salt on 304 and 316L at High Temperatures
- 29 November 2023
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 33 (24) , 13843-13854
Investigation on Corrosion Behaviors of Ternary Nitrate Molten Salt on 304 and 316L at High Temperatures
- 18 November 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (2) , 625-636
Study on combustion characteristics and flame retardants of bamboo powder
- 18 November 2023
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (2) , 625-636
Study on combustion characteristics and flame retardants of bamboo powder
- Open Access
- 12 October 2023
- Published by IWA Publishing in Water Science & Technology
- Vol. 88 (8) , 2081-2107
Review on descaling and anti-scaling technology of heat exchanger in high-salt wastewater thermal desalination
Thermal desalination evaporation of high-salt wastewater has been widely used in industry because of the proposed concept of ‘zero liquid discharge’. However, due to the high content of Ca2+ and Mg2+ in high-salt wastewater, the heat exchanger, as the main treatment equipment, suffers from serious scaling problems. This review presents descaling and scale inhibition technologies of high-salt wastewater. The advantages and disadvantages of various technologies are summarized and analyzed to provide theoretical support for the research of descaling and anti-scaling of heat exchangers with high-salt wastewater. In future industrial development, the synergistic application of electromagnetic water treatment technology and scale inhibitors can significantly improve the anti-scaling effect, which can reach over 95% stably. Furthermore, the addition of a physical field can also expand the application range of scale inhibitors.
- 12 October 2023
- Published by IWA Publishing in Water Science & Technology
- Vol. 88 (8) , 2081-2107
Open AccessReview on descaling and anti-scaling technology of heat exchanger in high-salt wastewater thermal desalination
Thermal desalination evaporation of high-salt wastewater has been widely used in industry because of the proposed concept of ‘zero liquid discharge’. However, due to the high content of Ca2+ and Mg2+ in high-salt wastewater, the heat exchanger, as the main treatment equipment, suffers from serious scaling problems. This review presents descaling and scale inhibition technologies of high-salt wastewater. The advantages and disadvantages of various technologies are summarized and analyzed to provide theoretical support for the research of descaling and anti-scaling of heat exchangers with high-salt wastewater. In future industrial development, the synergistic application of electromagnetic water treatment technology and scale inhibitors can significantly improve the anti-scaling effect, which can reach over 95% stably. Furthermore, the addition of a physical field can also expand the application range of scale inhibitors.
- 15 March 2018
- Published by Elsevier in Computers & Fluids
- Vol. 164, 27-34
Direct numerical method for studying heat transfer behaviors in an enclosure with dispersed thermal conductive particles
- 15 March 2018
- Published by Elsevier in Computers & Fluids
- Vol. 164, 27-34
Direct numerical method for studying heat transfer behaviors in an enclosure with dispersed thermal conductive particles