Zhiduo Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhiduo Liu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hongda Chen
State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, China
2 shared publications - Miao Yuan
The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
2 shared publications - Weihua Pei
Institute of Semiconductors, Chinese Academy of Sciences
2 shared publications - Yamin Li
The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
2 shared publications - Yijun Wang
Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
2 shared publications - Chunrong Wei
The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
- 22 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (2) , 108
Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at night. To avoid missing the peak value at night and sample the entire rhythm cycle, the continuous monitoring of IOP is urgently needed. A wearable contact lens IOP sensor based on a platinum (Pt) strain gauge is fabricated by the micro-electro-mechanical (MEMS) process. The structure and parameters of the strain gauge are optimized to improve the sensitivity and temperature stability. Tests on an eyeball model indicate that the IOP sensor has a high sensitivity of 289.5 μV/mmHg and excellent dynamic cycling performance at different speeds of IOP variation. The temperature drift coefficient of the sensor is 33.4 μV/°C. The non-invasive IOP sensor proposed in this report exhibits high sensitivity and satisfactory stability, promising a potential in continuous IOP monitoring.
- 22 January 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (2) , 108
Open AccessWearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at night. To avoid missing the peak value at night and sample the entire rhythm cycle, the continuous monitoring of IOP is urgently needed. A wearable contact lens IOP sensor based on a platinum (Pt) strain gauge is fabricated by the micro-electro-mechanical (MEMS) process. The structure and parameters of the strain gauge are optimized to improve the sensitivity and temperature stability. Tests on an eyeball model indicate that the IOP sensor has a high sensitivity of 289.5 μV/mmHg and excellent dynamic cycling performance at different speeds of IOP variation. The temperature drift coefficient of the sensor is 33.4 μV/°C. The non-invasive IOP sensor proposed in this report exhibits high sensitivity and satisfactory stability, promising a potential in continuous IOP monitoring.
- Open Access
- 23 September 2019
- Published by MDPI AG in Electronics
- Vol. 8 (10) , 1080
A Dry Electrode Cap and Its Application in a Steady-State Visual Evoked Potential-Based Brain–Computer Interface
The wearable electroencephalogram (EEG) dry electrode acquisition system has shown great application prospects in mental state monitoring, the brain–computer interface (BCI), and other fields due to advantages such as being small in volume, light weight, and a ready-to-use facility. This study demonstrates a novel EEG cap with concise structure, easy adjustment size, as well as independently adjustable electrodes. The cap can be rapidly worn and adjusted in both horizontal and vertical dimensions. The dry electrodes on it can be adjusted independently to fit the scalp as quickly as possible. The accuracy of the BCI test employing this device is higher than when employing a headband. The proposed EEG cap makes adjustment easier and the contact impedance of the dry electrodes more uniform.
- 23 September 2019
- Published by MDPI AG in Electronics
- Vol. 8 (10) , 1080
Open AccessA Dry Electrode Cap and Its Application in a Steady-State Visual Evoked Potential-Based Brain–Computer Interface
The wearable electroencephalogram (EEG) dry electrode acquisition system has shown great application prospects in mental state monitoring, the brain–computer interface (BCI), and other fields due to advantages such as being small in volume, light weight, and a ready-to-use facility. This study demonstrates a novel EEG cap with concise structure, easy adjustment size, as well as independently adjustable electrodes. The cap can be rapidly worn and adjusted in both horizontal and vertical dimensions. The dry electrodes on it can be adjusted independently to fit the scalp as quickly as possible. The accuracy of the BCI test employing this device is higher than when employing a headband. The proposed EEG cap makes adjustment easier and the contact impedance of the dry electrodes more uniform.