Alberto Moreno-Cansado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alberto Moreno-Cansado has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Jesús Carretero-Ayuso
Universidad de Extremadura
7 shared publications - Jorge de Brito
University of Lisbon
3 shared publications - Justo García-Sanz-Calcedo
Departamento de Expresión Gráfica, Escuela de Ingenierías Industriales, Universidad de Extremadura
2 shared publications Centro Universitario de Mérida Universidad de Extremadura
1 shared publication- Eduardo Manuel Cuerda Correa
Departamento de Química Orgánica e Inorgánica, Facultad de Ciencias, Universidad de Extremadura, Avenida de Elvas s/n, 06006 Badajoz, Spain
1 shared publication Universidad de Extremadura
1 shared publication
Latest Publications
- Open Access
- 30 September 2019
- Published by Editorial CSIC in Informes de la Construcción
- Vol. 71 (555) , e303
Cuantificación porcentual de los daños existentes en los revestimientos interiores de las viviendas españolas
Los revestimientos interiores son de las unidades constructivas que más interrelación tienen con los usuarios, dada su cercanía de uso con éstos. Esta investigación se centra en la determinación de los daños más usuales en los alicatados, enfoscados, guarnecidos, falsos techos y solados interiores, obtenidos en el conjunto de España a partir de los requerimientos presentados por los usuarios. Se determinan también cuáles son los orígenes que motivan estas deficiencias, así como la presencia que tienen las mismas en función del formato constructivo en donde tienen lugar (viviendas en bloque o unifamiliares). A partir de los datos manejados se presentan los grupos de daños más característicos, así como un procedimiento para determinar la probabilidad ante futuros requerimientos, en función de una matriz ponderada que clasifica la correspondencia entre los 4 descriptores manejados. El conocimiento de los resultados obtenidos ayudará a los técnicos a minimizar los daños en estas unidades constructivas.
- 30 September 2019
- Published by Editorial CSIC in Informes de la Construcción
- Vol. 71 (555) , e303
Open AccessCuantificación porcentual de los daños existentes en los revestimientos interiores de las viviendas españolas
Los revestimientos interiores son de las unidades constructivas que más interrelación tienen con los usuarios, dada su cercanía de uso con éstos. Esta investigación se centra en la determinación de los daños más usuales en los alicatados, enfoscados, guarnecidos, falsos techos y solados interiores, obtenidos en el conjunto de España a partir de los requerimientos presentados por los usuarios. Se determinan también cuáles son los orígenes que motivan estas deficiencias, así como la presencia que tienen las mismas en función del formato constructivo en donde tienen lugar (viviendas en bloque o unifamiliares). A partir de los datos manejados se presentan los grupos de daños más característicos, así como un procedimiento para determinar la probabilidad ante futuros requerimientos, en función de una matriz ponderada que clasifica la correspondencia entre los 4 descriptores manejados. El conocimiento de los resultados obtenidos ayudará a los técnicos a minimizar los daños en estas unidades constructivas.
- Open Access
- 2 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (7) , 1389
Influence of Climate Conditions on Deficiencies of Building Roofs
Climate conditions affect buildings’ performance and durability. The purpose of this paper is to examine the influence of climate conditions on roof deficiencies. 763 cases of such deficiencies were analyzed in this regard. Once the construction deficiencies were quantified, they were characterized from a climatological point of view and their ‘climate location segments’ were studied to obtain ‘ranges of concentration of anomalies’ according to the obtained percentage. A direct relation is shown to exist between the location of the building (latitude, situation, type of climate, precipitation, thermal demands, and average wind speed) and a greater or smaller concentration of deficiencies found in both flat and pitched buildings. It was also found that an annual average wind speed greater than 3 m/s increases the appearance of deficiencies in roofs. A higher prevalence of deficiencies was also found in those geographical zones with a thermal demand of 1800–2800 heating degree days or 450–700 cooling degree days. It was found that a higher percentage of construction deficiencies are concentrated in buildings located in the northern coastal climate segments of Spain. With these results, technicians will be able to take more appropriate precautions during both the building process and the use and maintenance phase.
- 2 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (7) , 1389
Open AccessInfluence of Climate Conditions on Deficiencies of Building Roofs
Climate conditions affect buildings’ performance and durability. The purpose of this paper is to examine the influence of climate conditions on roof deficiencies. 763 cases of such deficiencies were analyzed in this regard. Once the construction deficiencies were quantified, they were characterized from a climatological point of view and their ‘climate location segments’ were studied to obtain ‘ranges of concentration of anomalies’ according to the obtained percentage. A direct relation is shown to exist between the location of the building (latitude, situation, type of climate, precipitation, thermal demands, and average wind speed) and a greater or smaller concentration of deficiencies found in both flat and pitched buildings. It was also found that an annual average wind speed greater than 3 m/s increases the appearance of deficiencies in roofs. A higher prevalence of deficiencies was also found in those geographical zones with a thermal demand of 1800–2800 heating degree days or 450–700 cooling degree days. It was found that a higher percentage of construction deficiencies are concentrated in buildings located in the northern coastal climate segments of Spain. With these results, technicians will be able to take more appropriate precautions during both the building process and the use and maintenance phase.
- 5 October 2017
- Published by Springer Nature in International Journal of Civil Engineering
- Vol. 16 (12) , 1781-1796
General Survey of Construction-Related Complaints in Recent Buildings in Spain
- 5 October 2017
- Published by Springer Nature in International Journal of Civil Engineering
- Vol. 16 (12) , 1781-1796
General Survey of Construction-Related Complaints in Recent Buildings in Spain
- Open Access
- 5 May 2017
- Published by Pontificia Universidad Catolica de Chile in Revista de la construcción
- Vol. 16 (1) , 145-157
Failure and damage determination of building roofs
Journal of Construction is an international scientific publication, created on 2002 and edited by the Escuela de Construcción Civil of Pontificia Universidad Católica de Chile, Santiago, Chile.
- 5 May 2017
- Published by Pontificia Universidad Catolica de Chile in Revista de la construcción
- Vol. 16 (1) , 145-157
Open AccessFailure and damage determination of building roofs
Journal of Construction is an international scientific publication, created on 2002 and edited by the Escuela de Construcción Civil of Pontificia Universidad Católica de Chile, Santiago, Chile.
- 1 May 2017
- Published by Elsevier in Engineering Failure Analysis
- Vol. 75, 15-25
Study of the prevalence of critical and conflict-prone points in facades
- 1 May 2017
- Published by Elsevier in Engineering Failure Analysis
- Vol. 75, 15-25
Study of the prevalence of critical and conflict-prone points in facades
- 23 March 2017
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (4) , 490-498
An analysis of technical facilities failures in modern Spanish houses
The correct execution of facilities in housing determines their maintenance and comfort. The objective of this article is to identify the usual functional failures, common in technical facilities of houses, study their causes and determine their consequences. To this effect, a total of 153 detached houses (18%), 231 attached houses (27%), 444 apartment blocks (52%) and 26 residential buildings of other types (3%) were analysed. The facilities with the greatest number of detected failures were ‘covered sanitation pipes’ (24.00%), ‘exposed sanitation pipes’ (20.73%), ‘ventilation’ (13.93%), ‘heating and air conditioning’ (11.01%) and ‘plumbing’ (9.72%). The most common types of failures identified were ‘malfunctions’ (41.22%) and ‘humidity/runoffs in finished elements’ (37.55%). The housing typology which concentrates the most failures is ‘apartment block’ (52%), followed by ‘attached houses’ (27%). The causes, in general, are one of the following three: ‘installation anomaly’, ‘omission of/in an installation’ and ‘joints or tail-ends inadequately placed or deteriorated’. Practical application: This work presents a methodological procedure which allows designers to identify the most common incidences in building facilities and the causes leading to them, analyse their consequences and avoid their appearance in the design stage.
- 23 March 2017
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 38 (4) , 490-498
An analysis of technical facilities failures in modern Spanish houses
The correct execution of facilities in housing determines their maintenance and comfort. The objective of this article is to identify the usual functional failures, common in technical facilities of houses, study their causes and determine their consequences. To this effect, a total of 153 detached houses (18%), 231 attached houses (27%), 444 apartment blocks (52%) and 26 residential buildings of other types (3%) were analysed. The facilities with the greatest number of detected failures were ‘covered sanitation pipes’ (24.00%), ‘exposed sanitation pipes’ (20.73%), ‘ventilation’ (13.93%), ‘heating and air conditioning’ (11.01%) and ‘plumbing’ (9.72%). The most common types of failures identified were ‘malfunctions’ (41.22%) and ‘humidity/runoffs in finished elements’ (37.55%). The housing typology which concentrates the most failures is ‘apartment block’ (52%), followed by ‘attached houses’ (27%). The causes, in general, are one of the following three: ‘installation anomaly’, ‘omission of/in an installation’ and ‘joints or tail-ends inadequately placed or deteriorated’. Practical application: This work presents a methodological procedure which allows designers to identify the most common incidences in building facilities and the causes leading to them, analyse their consequences and avoid their appearance in the design stage.
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 30 (3)
Research and Analysis on Recurring Anomalies in Foundations and Structures
- 1 June 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 30 (3)
Research and Analysis on Recurring Anomalies in Foundations and Structures