Robert F. Labadie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert F. Labadie has a total of 244 co-authors. Here are the top co-authors by number of shared publications:
- Jack H. Noble
Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
12 shared publications - Benoit M. Dawant
Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
9 shared publications - René H. Gifford
Vanderbilt University
4 shared publications - Shaun A. Nguyen
Department of Otolaryngology–Head and Neck Surgery Medical University of South Carolina Charleston South Carolina USA
4 shared publications J. Michael Fitzpatrick
Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee
3 shared publications- Katelyn A. Berg
Department of Otolaryngology–Head and Neck Surgery, Vanderbilt University Medical Center
3 shared publications
Latest Publications
- 18 November 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Assessment of Magnetic Resonance Imaging–Derived Synthetic Computed Tomography for Otologic Surgical Planning
Objective: Synthetic computed tomography (sCT) techniques generate CT-equivalent images from magnetic resonance imaging to support surgical planning while reducing radiation exposure. Although prior work shows strong quantitative agreement between sCT and real CT (rCT), its clinical validity for otologic surgical planning remains uncertain. Study design: Cross-sectional reader study. Setting: Academic tertiary medical center. Participants: Otolaryngologists and neuroradiologists. Interventions: Participants reviewed 60 CT images (30 rCT, 30 sCT) and classified each as real or synthetic, while assessing acceptability for surgical planning. Paired rCT-sCT images were reviewed side-by-side to identify image type and evaluate potential limitations of sCT for clinical use. Main outcome measures: Accuracy of distinguishing sCT from rCT; acceptability of sCT for cochlear implant and middle ear surgical planning; qualitative assessment of anatomic discrepancies. Results: Nine readers participated. In single-image review, overall discrimination of sCT from rCT was limited, with mean accuracy of 57.2 ± 7.1% among otolaryngologists and 77.8 ± 1.0% among neuroradiologists (area under the curve: 0.60 ± 0.10 vs. 0.80 ± 0.01, P < 0.001). Acceptability ratings for cochlear implant planning were high for both rCT (97.8% to 98.9%) and sCT (90.0% to 93.9%), with similar findings for middle ear surgery (rCT 92.2% to 97.8%, sCT 86.7% to 87.8%). Concern regarding sCT reliability was reported in ∼20% of cases and primarily involved ossicular morphology, mastoid air cell architecture, and postoperative anatomy. Conclusions: This exploratory study suggests that sCT can approximate rCT for otologic surgical planning in cases with preserved anatomy, with high reported acceptability ratings across specialties. However, discrepancies identified in a subset of cases suggest that further validation is needed to define its role in clinical practice.
- 18 November 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Assessment of Magnetic Resonance Imaging–Derived Synthetic Computed Tomography for Otologic Surgical Planning
Objective: Synthetic computed tomography (sCT) techniques generate CT-equivalent images from magnetic resonance imaging to support surgical planning while reducing radiation exposure. Although prior work shows strong quantitative agreement between sCT and real CT (rCT), its clinical validity for otologic surgical planning remains uncertain. Study design: Cross-sectional reader study. Setting: Academic tertiary medical center. Participants: Otolaryngologists and neuroradiologists. Interventions: Participants reviewed 60 CT images (30 rCT, 30 sCT) and classified each as real or synthetic, while assessing acceptability for surgical planning. Paired rCT-sCT images were reviewed side-by-side to identify image type and evaluate potential limitations of sCT for clinical use. Main outcome measures: Accuracy of distinguishing sCT from rCT; acceptability of sCT for cochlear implant and middle ear surgical planning; qualitative assessment of anatomic discrepancies. Results: Nine readers participated. In single-image review, overall discrimination of sCT from rCT was limited, with mean accuracy of 57.2 ± 7.1% among otolaryngologists and 77.8 ± 1.0% among neuroradiologists (area under the curve: 0.60 ± 0.10 vs. 0.80 ± 0.01, P < 0.001). Acceptability ratings for cochlear implant planning were high for both rCT (97.8% to 98.9%) and sCT (90.0% to 93.9%), with similar findings for middle ear surgery (rCT 92.2% to 97.8%, sCT 86.7% to 87.8%). Concern regarding sCT reliability was reported in ∼20% of cases and primarily involved ossicular morphology, mastoid air cell architecture, and postoperative anatomy. Conclusions: This exploratory study suggests that sCT can approximate rCT for otologic surgical planning in cases with preserved anatomy, with high reported acceptability ratings across specialties. However, discrepancies identified in a subset of cases suggest that further validation is needed to define its role in clinical practice.
- Open Access
- 18 November 2026
- Published by Springer Nature in Neurosurgical Review
- Vol. 49 (1)
Microvascular decompression compared with other surgical interventions for trigeminal neuralgia: A systematic review and meta-analysis
Microvascular decompression (MVD) is often considered the standard of care operation for medically refractory primary trigeminal neuralgia (PTN), yet there is variable evidence comparing its effectiveness with other procedures such as percutaneous balloon compression (PBC) or stereotactic radiosurgery (SRS). Following PRISMA guidelines, we systematically searched CINAHL, Cochrane Library, Embase, PubMed, and Scopus from inception through April 1, 2026. Studies of surgically naïve PTN patients undergoing procedural and surgical interventions for PTN comparing MVD with at least one other procedural or surgical intervention were included. Outcomes focused on pain relief, recurrence, repeat procedures, and complications. A total of 26 studies (7 prospective, including two randomized controlled trials, and 19 retrospective) comprising 3,806 patients were included. Across predominantly retrospective cohorts, MVD was associated with higher short‑term and long‑term pain relief and lower crude recurrence and reoperation rates than SRS (e.g., short‑term 94.7% vs. 67.3%; long‑term 79.4% vs. 55.4%; recurrence 9.5% vs. 32.0%). Versus RFR, MVD showed higher short‑term (89.0% vs. 68.5%) and long‑term pain relief (72.1% vs. 54.7%), with lower crude recurrence (20.7% vs. 38.3%) and fewer repeat procedures (10.7% vs. 53.5%). MVD and PBC demonstrated similar short‑term (89.3% vs. 91.8%) and long‑term relief (83.9% vs. 79.7%), whereas crude recurrence rates favored MVD (11.1% vs. 18.3%). Limited data suggested higher long‑term pain relief with MVD versus partial sensory rhizotomy (88.9% vs. 70.9%). MVD generally showed lower rates of persistent sensory complications than ablative or radiosurgical procedures. These patterns arise largely from nonrandomized studies with baseline imbalances and variable follow‑up. Recurrence and long‑term estimates are crude proportions without time‑to‑event adjustment and are therefore exploratory and descriptive. This systematic review and meta-analysis suggests that MVD is an important option for appropriately selected PTN patients, with observational comparative data showing higher crude long‑term pain relief, lower crude recurrence, and fewer persistent sensory complications than several alternatives. Given the predominance of retrospective, nonrandomized cohorts and heterogeneous follow‑up, the pooled recurrence and long‑term estimates are exploratory descriptive findings and cannot establish comparative durability or superiority of MVD over alternative interventions.
- 18 November 2026
- Published by Springer Nature in Neurosurgical Review
- Vol. 49 (1)
Open AccessMicrovascular decompression compared with other surgical interventions for trigeminal neuralgia: A systematic review and meta-analysis
Microvascular decompression (MVD) is often considered the standard of care operation for medically refractory primary trigeminal neuralgia (PTN), yet there is variable evidence comparing its effectiveness with other procedures such as percutaneous balloon compression (PBC) or stereotactic radiosurgery (SRS). Following PRISMA guidelines, we systematically searched CINAHL, Cochrane Library, Embase, PubMed, and Scopus from inception through April 1, 2026. Studies of surgically naïve PTN patients undergoing procedural and surgical interventions for PTN comparing MVD with at least one other procedural or surgical intervention were included. Outcomes focused on pain relief, recurrence, repeat procedures, and complications. A total of 26 studies (7 prospective, including two randomized controlled trials, and 19 retrospective) comprising 3,806 patients were included. Across predominantly retrospective cohorts, MVD was associated with higher short‑term and long‑term pain relief and lower crude recurrence and reoperation rates than SRS (e.g., short‑term 94.7% vs. 67.3%; long‑term 79.4% vs. 55.4%; recurrence 9.5% vs. 32.0%). Versus RFR, MVD showed higher short‑term (89.0% vs. 68.5%) and long‑term pain relief (72.1% vs. 54.7%), with lower crude recurrence (20.7% vs. 38.3%) and fewer repeat procedures (10.7% vs. 53.5%). MVD and PBC demonstrated similar short‑term (89.3% vs. 91.8%) and long‑term relief (83.9% vs. 79.7%), whereas crude recurrence rates favored MVD (11.1% vs. 18.3%). Limited data suggested higher long‑term pain relief with MVD versus partial sensory rhizotomy (88.9% vs. 70.9%). MVD generally showed lower rates of persistent sensory complications than ablative or radiosurgical procedures. These patterns arise largely from nonrandomized studies with baseline imbalances and variable follow‑up. Recurrence and long‑term estimates are crude proportions without time‑to‑event adjustment and are therefore exploratory and descriptive. This systematic review and meta-analysis suggests that MVD is an important option for appropriately selected PTN patients, with observational comparative data showing higher crude long‑term pain relief, lower crude recurrence, and fewer persistent sensory complications than several alternatives. Given the predominance of retrospective, nonrandomized cohorts and heterogeneous follow‑up, the pooled recurrence and long‑term estimates are exploratory descriptive findings and cannot establish comparative durability or superiority of MVD over alternative interventions.
- 5 November 2026
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 35 (6) , 3469-3483
An Exploratory Study of Image-Guided Cochlear Implant Intervention on Articulation and Phonological Processing in Children With Speech Sound Disorders
Purpose: Poor spectral clarity from cochlear implants (CIs) has been hypothesized to contribute to articulation and phonological processing deficits among children with CIs. Therefore, CI programming techniques that aim to improve spectral resolution may lead to improvements in articulation and phonological processing skills (i.e., phonological awareness as well as phonological and phonetic recoding). Method: We analyzed the articulation and phonological skills of 21 children with CIs (4.7–13.1 years old) with articulation and phonological processing deficits who were enrolled in a 2-year waitlist-deferred randomized controlled trial examining image-guided cochlear implant programming (IGCIP). In the clinical trial, participants were randomly assigned to receive IGCIP at varying time points throughout the study. Change over time in articulation and phonological processing was assessed in the subset of 21 children. Additionally, an exploratory analysis of the effect of IGCIP on articulation and phonological processing skills was completed. Results: Only articulation, not phonological processing, improved relative to age norms. IGCIP did not have a statistically significant effect on articulation or phonological processing in the first year of the study. However, participants who received IGCIP within the first year of the study did exhibit larger and clinically meaningful improvements in articulation scores compared with those who did not receive IGCIP. Conclusions: Articulation deficits, but not phonological processing deficits, improved over time among children with CIs. Future studies should assess the impact of IGCIP on articulation within a larger sample of CI users with articulation deficits to clarify its role in such improvements.
- 5 November 2026
- Published by American Speech Language Hearing Association in American Journal of Speech-Language Pathology
- Vol. 35 (6) , 3469-3483
An Exploratory Study of Image-Guided Cochlear Implant Intervention on Articulation and Phonological Processing in Children With Speech Sound Disorders
Purpose: Poor spectral clarity from cochlear implants (CIs) has been hypothesized to contribute to articulation and phonological processing deficits among children with CIs. Therefore, CI programming techniques that aim to improve spectral resolution may lead to improvements in articulation and phonological processing skills (i.e., phonological awareness as well as phonological and phonetic recoding). Method: We analyzed the articulation and phonological skills of 21 children with CIs (4.7–13.1 years old) with articulation and phonological processing deficits who were enrolled in a 2-year waitlist-deferred randomized controlled trial examining image-guided cochlear implant programming (IGCIP). In the clinical trial, participants were randomly assigned to receive IGCIP at varying time points throughout the study. Change over time in articulation and phonological processing was assessed in the subset of 21 children. Additionally, an exploratory analysis of the effect of IGCIP on articulation and phonological processing skills was completed. Results: Only articulation, not phonological processing, improved relative to age norms. IGCIP did not have a statistically significant effect on articulation or phonological processing in the first year of the study. However, participants who received IGCIP within the first year of the study did exhibit larger and clinically meaningful improvements in articulation scores compared with those who did not receive IGCIP. Conclusions: Articulation deficits, but not phonological processing deficits, improved over time among children with CIs. Future studies should assess the impact of IGCIP on articulation within a larger sample of CI users with articulation deficits to clarify its role in such improvements.
- 19 October 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Cost-Effectiveness of Intraoperative Facial Nerve Monitoring in Otologic Surgery
Objective: Evaluate the cost-effectiveness of intraoperative facial nerve monitoring (FNM) during otologic/neurotologic surgery. Study design: Decision-tree cost-effectiveness analysis with probabilistic sensitivity analysis using 1000-iteration Monte Carlo simulation. Setting: Tertiary academic center. Patients: Hypothetical adult cohort undergoing otologic surgery. Interventions: FNM for all otologic surgeries, FNM for revision surgeries only, and no FNM. Main outcome measures: Expected quality-adjusted life years (QALYs), expected cost per patient, incremental cost-effectiveness ratio (ICER; difference in cost/difference in QALY), and probability of cost-effectiveness at willingness-to-pay thresholds. Results: FNM for all otologic surgeries (both primary and revision) was associated with an increase in QALYs of 0.18 compared with no monitoring. Average cost increased by $169.99 per patient for equipment purchased from vendor 1 (ICER=$968.21/QALY), by $58.99 with vendor 2 (ICER=$336.00/QALY), and by $6.99 with vendor 3 (ICER=$39.83/QALY). Probabilistic sensitivity analysis demonstrated that monitoring all otologic surgeries was the most cost-effective strategy in most simulations (93% for vendor 1, 96% for vendor 2, and 95% for vendor 3) at a $50,000/QALY willingness-to-pay threshold. Sensitivity analysis suggested FNM to be cost-effective over a wide range of costs and probabilities. Conclusions: FNM for otologic surgery is cost-effective across vendors. Although use of higher-cost electrodes leads to increases in per-patient cost, the incremental cost per QALY gained remains minimal and well below accepted thresholds. These findings suggest routine FNM use in all cases is cost-effective, particularly in institutions with surgical volume to exceed break-even thresholds.
- 19 October 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Cost-Effectiveness of Intraoperative Facial Nerve Monitoring in Otologic Surgery
Objective: Evaluate the cost-effectiveness of intraoperative facial nerve monitoring (FNM) during otologic/neurotologic surgery. Study design: Decision-tree cost-effectiveness analysis with probabilistic sensitivity analysis using 1000-iteration Monte Carlo simulation. Setting: Tertiary academic center. Patients: Hypothetical adult cohort undergoing otologic surgery. Interventions: FNM for all otologic surgeries, FNM for revision surgeries only, and no FNM. Main outcome measures: Expected quality-adjusted life years (QALYs), expected cost per patient, incremental cost-effectiveness ratio (ICER; difference in cost/difference in QALY), and probability of cost-effectiveness at willingness-to-pay thresholds. Results: FNM for all otologic surgeries (both primary and revision) was associated with an increase in QALYs of 0.18 compared with no monitoring. Average cost increased by $169.99 per patient for equipment purchased from vendor 1 (ICER=$968.21/QALY), by $58.99 with vendor 2 (ICER=$336.00/QALY), and by $6.99 with vendor 3 (ICER=$39.83/QALY). Probabilistic sensitivity analysis demonstrated that monitoring all otologic surgeries was the most cost-effective strategy in most simulations (93% for vendor 1, 96% for vendor 2, and 95% for vendor 3) at a $50,000/QALY willingness-to-pay threshold. Sensitivity analysis suggested FNM to be cost-effective over a wide range of costs and probabilities. Conclusions: FNM for otologic surgery is cost-effective across vendors. Although use of higher-cost electrodes leads to increases in per-patient cost, the incremental cost per QALY gained remains minimal and well below accepted thresholds. These findings suggest routine FNM use in all cases is cost-effective, particularly in institutions with surgical volume to exceed break-even thresholds.
- Open Access
- 22 July 2026
- Published by Springer Nature
- p. 423-433
Image-Guided Systems in Temporal Bone and Skull Base Surgery
Image guidance is a part of the cutting edge of otologic and neurotologic surgery. The critical structures within the temporal bone generally have conserved and measurable relationships with the surrounding bone, which allows imaging to create accurate anatomical estimates that can be followed by a surgeon, human, or robot. As a relatively new area of temporal bone and skull base surgery, this field is filled with concepts and companies seeking adaptation, creating multiple, critical considerations for surgeons and scientists, which are discussed in this chapter.
- 22 July 2026
- Published by Springer Nature
- p. 423-433
Open AccessImage-Guided Systems in Temporal Bone and Skull Base Surgery
Image guidance is a part of the cutting edge of otologic and neurotologic surgery. The critical structures within the temporal bone generally have conserved and measurable relationships with the surrounding bone, which allows imaging to create accurate anatomical estimates that can be followed by a surgeon, human, or robot. As a relatively new area of temporal bone and skull base surgery, this field is filled with concepts and companies seeking adaptation, creating multiple, critical considerations for surgeons and scientists, which are discussed in this chapter.
- Open Access
- 14 April 2026
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 175 (1) , 21-30
Canal Cholesteatoma Presentation and Management: A Systematic Review and Meta‐Analysis
Objective: To evaluate current understanding of external auditory canal cholesteatoma (EACC), its symptomatic burden, clinical features, diagnostic approach, and management strategies to reduce delays in diagnosis. Data Sources: PubMed, CINAHL, COCHRANE Library, and SCOPUS. Review Methods: A comprehensive literature search was completed in March 2025. The search identified 2117 English‐language articles, of which 30 studies reported patients diagnosed with EACC. Meta‐analyses of mean difference (Δ), proportions (%), and continuous measures with 95% confidence intervals (CI) were performed using random and fixed effects models. Results: A total of 1007 patients were included with a mean age of 43.9 years (range 6‐89). Most were diagnosed with Stage III EACC (60.7%, CI 43.5‐76.7). Nicotine use (33.1%, CI 15.2‐54.1) and cotton swab abuse (24.3%, CI 16.7‐33.7) were common risk factors. Patients most often presented with otalgia (39.9%, CI 30.5‐49.7) or otorrhea (50.3%, CI 37.8‐62.7), though 15.7% (CI 4.5‐31.6) were asymptomatic. Conservative treatment with serial debridement was used in most patients (69.6%, CI 44.5‐89.7). Canalplasty (68.6%, CI 48.3‐85.7), tympanoplasty (24.7%, CI 3.7‐56.1), and mastoidectomy (33.7%, CI 17.4‐52.3) were the most common surgical approaches. Recurrence was low (4.5%; 95% CI 2.3‐8.0). Conclusion: Patients with EACC are frequently diagnosed at advanced stages. Recognizing risk factors and symptoms can expedite detection and guide management. This review highlights how tailored interventions achieve low recurrence rates and reduce morbidity linked to delayed diagnosis.
- 14 April 2026
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 175 (1) , 21-30
Open AccessCanal Cholesteatoma Presentation and Management: A Systematic Review and Meta‐Analysis
Objective: To evaluate current understanding of external auditory canal cholesteatoma (EACC), its symptomatic burden, clinical features, diagnostic approach, and management strategies to reduce delays in diagnosis. Data Sources: PubMed, CINAHL, COCHRANE Library, and SCOPUS. Review Methods: A comprehensive literature search was completed in March 2025. The search identified 2117 English‐language articles, of which 30 studies reported patients diagnosed with EACC. Meta‐analyses of mean difference (Δ), proportions (%), and continuous measures with 95% confidence intervals (CI) were performed using random and fixed effects models. Results: A total of 1007 patients were included with a mean age of 43.9 years (range 6‐89). Most were diagnosed with Stage III EACC (60.7%, CI 43.5‐76.7). Nicotine use (33.1%, CI 15.2‐54.1) and cotton swab abuse (24.3%, CI 16.7‐33.7) were common risk factors. Patients most often presented with otalgia (39.9%, CI 30.5‐49.7) or otorrhea (50.3%, CI 37.8‐62.7), though 15.7% (CI 4.5‐31.6) were asymptomatic. Conservative treatment with serial debridement was used in most patients (69.6%, CI 44.5‐89.7). Canalplasty (68.6%, CI 48.3‐85.7), tympanoplasty (24.7%, CI 3.7‐56.1), and mastoidectomy (33.7%, CI 17.4‐52.3) were the most common surgical approaches. Recurrence was low (4.5%; 95% CI 2.3‐8.0). Conclusion: Patients with EACC are frequently diagnosed at advanced stages. Recognizing risk factors and symptoms can expedite detection and guide management. This review highlights how tailored interventions achieve low recurrence rates and reduce morbidity linked to delayed diagnosis.
- Open Access
- 12 January 2026
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 174 (3) , 613-627
Suicidality in Individuals With Hearing Loss: A Systematic Review and Meta‐Analysis
Objective: To evaluate the prevalence of suicidality, including suicidal ideation and attempts, in individuals with any type of hearing loss compared to individuals without hearing loss, and to assess risk factors for suicidality in this population. Data Sources: CINAHL, Cochrane Review, PubMed, Scopus, and PsycINFO through March 25, 2025. Review Methods: Two investigators independently performed the search, screened abstracts, and selected publications for data extraction. Studies that assessed hearing loss and at least one suicidality measure in individuals aged 16 years or older were included for fixed and random‐effects meta‐analyses (proportions, continuous measures, relative risks [RR]). Depression and social isolation were also assessed. Results: Of 5,015 abstracts identified, 14 studies (N = 221,681) were included. Individuals with hearing loss had higher prevalences of suicidal ideation (13.2% vs 9.3%) and suicide attempts (4.9% vs 2.4%) compared to controls ( P < .0001). Hearing loss was associated with significantly increased risks of suicidal ideation (RR = 1.47, 95% CI [1.37‐1.57]) and suicide attempts (RR = 1.83, 95% CI [1.31‐2.55]). Subgroup analyses revealed that risk of depression was elevated only in individuals with subjective hearing loss, while risk of suicidal ideation was increased in individuals with either subjective or audiometrically measured hearing loss. Conclusion: This meta‐analysis demonstrates a clear association between hearing loss and suicidality, although the strength of this relationship varies depending on how hearing loss is measured. Clinicians should consider both audiometric data and patient‐reported concerns when assessing psychiatric risk. These findings support early screening and timely interventions to mitigate mental health consequences.
- 12 January 2026
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 174 (3) , 613-627
Open AccessSuicidality in Individuals With Hearing Loss: A Systematic Review and Meta‐Analysis
Objective: To evaluate the prevalence of suicidality, including suicidal ideation and attempts, in individuals with any type of hearing loss compared to individuals without hearing loss, and to assess risk factors for suicidality in this population. Data Sources: CINAHL, Cochrane Review, PubMed, Scopus, and PsycINFO through March 25, 2025. Review Methods: Two investigators independently performed the search, screened abstracts, and selected publications for data extraction. Studies that assessed hearing loss and at least one suicidality measure in individuals aged 16 years or older were included for fixed and random‐effects meta‐analyses (proportions, continuous measures, relative risks [RR]). Depression and social isolation were also assessed. Results: Of 5,015 abstracts identified, 14 studies (N = 221,681) were included. Individuals with hearing loss had higher prevalences of suicidal ideation (13.2% vs 9.3%) and suicide attempts (4.9% vs 2.4%) compared to controls ( P < .0001). Hearing loss was associated with significantly increased risks of suicidal ideation (RR = 1.47, 95% CI [1.37‐1.57]) and suicide attempts (RR = 1.83, 95% CI [1.31‐2.55]). Subgroup analyses revealed that risk of depression was elevated only in individuals with subjective hearing loss, while risk of suicidal ideation was increased in individuals with either subjective or audiometrically measured hearing loss. Conclusion: This meta‐analysis demonstrates a clear association between hearing loss and suicidality, although the strength of this relationship varies depending on how hearing loss is measured. Clinicians should consider both audiometric data and patient‐reported concerns when assessing psychiatric risk. These findings support early screening and timely interventions to mitigate mental health consequences.
- 18 January 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 146 (2) , 159-175
Does cochlear implant electrode array design affect audiologic outcomes? A systematic review and meta-analysis
There is conflicting literature regarding whether cochlear implants (CI) electrode array (EA) selection impacts audiologic outcomes. To compare outcomes for the two EA designs, precurved and straight. A systematic search of CINAHL, Cochrane Library, PubMed, and SCOPUS was conducted according to PRISMA guidelines. Included studies reported word recognition scores, sentence recognition scores in quiet or noise, or hearing preservation (HP) rates for patients with post-lingual hearing loss who underwent CI with either EA type. Primary outcome measures included mean difference (baseline vs. post-surgery) and proportions (%) with 95% confidence intervals (CI). Of 4134 unique abstracts screened, 92 studies (N = 5365 patients, 5658 ears) were included. Mean improvement of overall word recognition scores for patients with precurved EAs (46.5%, 95% CI: 43.13-49.88%) was significantly (p = 0.0009) superior to that of patients with straight EAs (36.33%; 95% CI, 31.4-41.27%). There was no significant difference between mean improvement of Azbio Quiet scores, mean improvement of overall sentences in noise scores, or HP or pure-tone averages between patients with precurved EAs and those with straight EAs. Precurved EAs were superior in mean word recognition score improvement, but there was no superior EA design regarding sentence recognition or hearing preservation.
- 18 January 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 146 (2) , 159-175
Does cochlear implant electrode array design affect audiologic outcomes? A systematic review and meta-analysis
There is conflicting literature regarding whether cochlear implants (CI) electrode array (EA) selection impacts audiologic outcomes. To compare outcomes for the two EA designs, precurved and straight. A systematic search of CINAHL, Cochrane Library, PubMed, and SCOPUS was conducted according to PRISMA guidelines. Included studies reported word recognition scores, sentence recognition scores in quiet or noise, or hearing preservation (HP) rates for patients with post-lingual hearing loss who underwent CI with either EA type. Primary outcome measures included mean difference (baseline vs. post-surgery) and proportions (%) with 95% confidence intervals (CI). Of 4134 unique abstracts screened, 92 studies (N = 5365 patients, 5658 ears) were included. Mean improvement of overall word recognition scores for patients with precurved EAs (46.5%, 95% CI: 43.13-49.88%) was significantly (p = 0.0009) superior to that of patients with straight EAs (36.33%; 95% CI, 31.4-41.27%). There was no significant difference between mean improvement of Azbio Quiet scores, mean improvement of overall sentences in noise scores, or HP or pure-tone averages between patients with precurved EAs and those with straight EAs. Precurved EAs were superior in mean word recognition score improvement, but there was no superior EA design regarding sentence recognition or hearing preservation.
- 2 January 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (3) , e88-e90
Use of Photon-Counting Detector Computed Tomography (PCD-CT) in a Revision Cochlear Implant
- 2 January 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (3) , e88-e90
Use of Photon-Counting Detector Computed Tomography (PCD-CT) in a Revision Cochlear Implant
- Open Access
Zero-Shot Surgical Tool Segmentation in Monocular Video Using Segment Anything Model 2
The Segment Anything Model 2 (SAM 2) is the latest generation foundation model for image and video segmentation. Trained on the expansive Segment Anything Video (SA-V) dataset, which comprises 35.5 million masks across 50.9K videos, SAM 2 advances its predecessor's capabilities by supporting zero-shot segmentation through various prompts (e.g., points, boxes, and masks). Its robust zero-shot performance and efficient memory usage make SAM 2 particularly appealing for surgical tool segmentation in videos, especially given the scarcity of labeled data and the diversity of surgical procedures. In this study, we evaluate the zero-shot video segmentation performance of the SAM 2 model across different types of surgeries, including endoscopy and microscopy. We also assess its performance on videos featuring single and multiple tools of varying lengths to demonstrate SAM 2's applicability and effectiveness in the surgical domain. We found that: 1) SAM 2 demonstrates a strong capability for segmenting various surgical videos; 2) When new tools enter the scene, additional prompts are necessary to maintain segmentation accuracy; and 3) Specific challenges inherent to surgical videos can impact the robustness of SAM 2.
Open AccessZero-Shot Surgical Tool Segmentation in Monocular Video Using Segment Anything Model 2
The Segment Anything Model 2 (SAM 2) is the latest generation foundation model for image and video segmentation. Trained on the expansive Segment Anything Video (SA-V) dataset, which comprises 35.5 million masks across 50.9K videos, SAM 2 advances its predecessor's capabilities by supporting zero-shot segmentation through various prompts (e.g., points, boxes, and masks). Its robust zero-shot performance and efficient memory usage make SAM 2 particularly appealing for surgical tool segmentation in videos, especially given the scarcity of labeled data and the diversity of surgical procedures. In this study, we evaluate the zero-shot video segmentation performance of the SAM 2 model across different types of surgeries, including endoscopy and microscopy. We also assess its performance on videos featuring single and multiple tools of varying lengths to demonstrate SAM 2's applicability and effectiveness in the surgical domain. We found that: 1) SAM 2 demonstrates a strong capability for segmenting various surgical videos; 2) When new tools enter the scene, additional prompts are necessary to maintain segmentation accuracy; and 3) Specific challenges inherent to surgical videos can impact the robustness of SAM 2.