M. V. Zhukova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M. V. Zhukova has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. S. Lunev
A.I.Burnasyan Federal Medical Biophysical Center;Moscow State Academy of Veterinary Medicine and Biotechnology
1 shared publication- Alina Krasnoperova
State Research Center—Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency, Zhivopisnaya str., bld. 46; 123182 Moscow, Russian
1 shared publication - Anton A. Larenkov
State Research Center – Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency
1 shared publication - Artur G. Makichyan
State Research Center–Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency, Zhivopisnaya Str., bld. 46, 123098 Moscow, Russia
1 shared publication - Galina E. Kodina
National Medical Research Radiological Centre
1 shared publication K. A. Petrosova
A.I.Burnasyan Federal Medical Biophysical Center
1 shared publication
Latest Publications
- Open Access
Preparation of Zirconium-89 Solutions for Radiopharmaceutical Purposes: Interrelation Between Formulation, Radiochemical Purity, Stability and Biodistribution
Zirconium-89 is a promising radionuclide for nuclear medicine. The aim of the present work was to find a suitable method for obtaining zirconium-89 solutions for radiopharmaceutical purposes. For this purpose, the ion exchange behavior of zirconium-89 solutions was studied. Radio-TLC (thin layer chromatography) and biodistribution studies were carried out to understand speciation of zirconium-89 complexes and their role in the development of new radiopharmaceuticals. Three methods of zirconium-89 isolation were studied using ZR (hydroxamate) and Chelex-100 resins. It was found that ZR-resin alone is not enough to obtain stable zirconium-89 formulations. An easy and effective method of reconstitution of [89Zr]Zr-oxalate to [89Zr]Zr-citrate using Chelex-100 resin was developed. Developed procedures allow obtaining [89Zr]Zr-oxalate (in 0.1 M sodium oxalate solution) and [89Zr]Zr-citrate (in 0.1–1.0 M sodium citrate solution). These solutions are perfectly suitable and convenient for radiopharmaceutical purposes. Our results prove [89Zr]Zr-citrate to be advantageous over [89Zr]Zr-oxalate. During evaluation of speciation of zirconium-89 complexes, a new TLC method was developed, since it was proved that there is no comprehensive method for analysis or zirconium-89 preparations. The new method provides valuable insights about the content of “active” ionic form of zirconium-89. The interrelation of the chromatographic behavior of zirconium-89 preparations and their biodistribution was studied.
Open AccessPreparation of Zirconium-89 Solutions for Radiopharmaceutical Purposes: Interrelation Between Formulation, Radiochemical Purity, Stability and Biodistribution
Zirconium-89 is a promising radionuclide for nuclear medicine. The aim of the present work was to find a suitable method for obtaining zirconium-89 solutions for radiopharmaceutical purposes. For this purpose, the ion exchange behavior of zirconium-89 solutions was studied. Radio-TLC (thin layer chromatography) and biodistribution studies were carried out to understand speciation of zirconium-89 complexes and their role in the development of new radiopharmaceuticals. Three methods of zirconium-89 isolation were studied using ZR (hydroxamate) and Chelex-100 resins. It was found that ZR-resin alone is not enough to obtain stable zirconium-89 formulations. An easy and effective method of reconstitution of [89Zr]Zr-oxalate to [89Zr]Zr-citrate using Chelex-100 resin was developed. Developed procedures allow obtaining [89Zr]Zr-oxalate (in 0.1 M sodium oxalate solution) and [89Zr]Zr-citrate (in 0.1–1.0 M sodium citrate solution). These solutions are perfectly suitable and convenient for radiopharmaceutical purposes. Our results prove [89Zr]Zr-citrate to be advantageous over [89Zr]Zr-oxalate. During evaluation of speciation of zirconium-89 complexes, a new TLC method was developed, since it was proved that there is no comprehensive method for analysis or zirconium-89 preparations. The new method provides valuable insights about the content of “active” ionic form of zirconium-89. The interrelation of the chromatographic behavior of zirconium-89 preparations and their biodistribution was studied.
- Open Access
- 28 February 2016
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Toxicological Review
- No. 1,p. 21-30
TOXICITY EVALUATION OF SAFETY OF LIOPHILIZATES USED FOR FORMULATION OF THE RADIOPHARMACEUTICAL PREPARATION 68Ga-CITRATE IN EXPERIMENT IN RODENTS
Toxicity effects of «Cigalin» and «Ferocit» lyophilizates used for formulation of the radiopharmaceutical preparation 68Ga-citrate were studied in animal organisms (rats, mice). Good tolerability, absence of pronounced intoxication symptoms, allergenic effects and animal deaths were noted in experiments using a recommended clinic dose of lyophilizates. «Cigalin» didn’t produce toxicity effects influencing on statistically significant changes in blood main hematological and biochemical parameters. Similar changes in case of «Ferocit» used in multiple doses were functionally reversible. The results permit to characterize 68Ga-citrate as safe for clinical applications in radionuclide diagnostics for PET imaging of inflammation and infection.
- 28 February 2016
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Toxicological Review
- No. 1,p. 21-30
Open AccessTOXICITY EVALUATION OF SAFETY OF LIOPHILIZATES USED FOR FORMULATION OF THE RADIOPHARMACEUTICAL PREPARATION 68Ga-CITRATE IN EXPERIMENT IN RODENTS
Toxicity effects of «Cigalin» and «Ferocit» lyophilizates used for formulation of the radiopharmaceutical preparation 68Ga-citrate were studied in animal organisms (rats, mice). Good tolerability, absence of pronounced intoxication symptoms, allergenic effects and animal deaths were noted in experiments using a recommended clinic dose of lyophilizates. «Cigalin» didn’t produce toxicity effects influencing on statistically significant changes in blood main hematological and biochemical parameters. Similar changes in case of «Ferocit» used in multiple doses were functionally reversible. The results permit to characterize 68Ga-citrate as safe for clinical applications in radionuclide diagnostics for PET imaging of inflammation and infection.