BWBettine G. van Willigen

Bettine G. van Willigen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bettine G. van Willigen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Frans N. van de Vosse

    Biomedical Engineering Cardiovascular Biomechanics Eindhoven University of Technology Eindhoven The Netherlands

    6 shared publications
  • Wouter Huberts

    Cardiovascular Biomechanics, Eindhoven University of Technology

    4 shared publications
  • M. Beatrijs van der Hout-Van der Jagt

    Cardiovascular Biomechanics, Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands

    2 shared publications
  • M. Beatrijs van der Hout‐Van der Jagt

    Obstetrics and Gynaecology, Máxima Medical Centre Veldhoven The Netherlands

    2 shared publications
  • Wouter Huberts

    Eindhoven University of Technology

    2 shared publications
  • Babette C. Krabben

    Biomedical Engineering Cardiovascular Biomechanics Eindhoven University of Technology Eindhoven The Netherlands

    1 shared publication

Latest Publications

  • Open Access

    Sex-specific assumptions underlie cardiovascular digital twin technologies: A narrative review

    by Bettine G. van Willigen, Henk A. Marquering, Wouter Huberts, Joris R. de Groot

    Digital twin technologies (DTTs) are increasingly applied in cardiovascular medicine to support personalized treatment. At the same time, growing evidence demonstrates sex differences in cardiovascular anatomy, physiology, disease presentation, and outcomes. Whether current cardiovascular DTTs adequately incorporate these sex-specific characteristics is unclear. This narrative review examines how sex bias and inclusivity are addressed within cardiovascular DTTs and identifies where sex-related bias may arise within different components of DTT. A six-dimensional digital twin framework is introduced to review DTTs. We focus on three cardiovascular domains: coronary artery disease, aortic valve stenosis, and atrial fibrillation. For each domain, we assessed sex representation in modeling assumptions, data interpretation, clinical outputs, and validation studies. Within three domains, physiological assumptions, boundary conditions, interpretation thresholds, and validation cohorts, models are frequently derived from sex-skewed populations. DTTs estimating noninvasive fractional flow reserve are predominantly validated in male-dominated cohorts, potentially resulting in lower precision in women. In contrast, validation studies for DTTs in TAVI planning show variable sex distributions, with some cohorts being female-skewed and others male-skewed, raising questions about their generalizability across sexes. In both model-based DTTs, sex bias may arise from generalized boundary conditions. Electro-anatomical mapping systems for atrial fibrillation are susceptible to sex bias within measurement methodology. Uniform clinical thresholding and outcome selection bias further add to sex-bias in DTTs. Current cardiovascular DTTs insufficiently account for sex-specific cardiovascular characteristics, risking underperformance in underrepresented populations. Incorporating sex-aware physiological parameters, sex-stratified validation, balanced datasets, and transparent reporting should be considered minimal standards for future clinical implementation.

  • Open Access

    The hemodynamic impact of congenital heart diseases during fetal-to-neonatal transition: an in-silico investigation

    by Bettine G. van Willigen, Babette C. Krabben, M. Beatrijs van der Hout-Van der Jagt, Wouter Huberts, Frans N. van de Vosse

    Background: Congenital heart disease (CHD) is a significant congenital anomaly, with ventricular septal defect (VSD) and transposition of the great arteries (TGA) being commonly encountered. Despite advancements in prenatal diagnosis and postnatal care, predicting neonatal outcomes remains difficult due to fetal compensatory mechanisms. This study utilizes and adapts existing mathematical models, without patient-specific parameters, to simulate the hemodynamic effects of VSD and TGA during the fetal-to-neonatal transition, validated against literature data. Method: The model uses a closed-loop 0D-1D cardiovascular system and an oxygen-carbon dioxide exchange model to retrieve clinically relevant information. Results: Results show realistic replication of flow, pressure profiles, oxygen saturation, and carbon dioxide levels for both normal and CHD-compromised fetuses. Conclusion: The mathematical model offers valuable insights into hemodynamic alterations during the fetal-to-neonatal transition, also under two pathophysiological conditions. It provides a non-invasive means of predicting clinically relevant parameters, which is essential for postnatal treatment planning in the prenatal period, especially given the potential need for immediate postnatal hemodynamic management. Overall, this model presents a promising tool for predicting the impact of CHD postnatally based on prenatal information and for guiding timely and effective treatment strategies. As such, the model may be considered as a potential basis for other applications in perinatal hemodynamics including fetal-to-neonatal transition. Impact: This study introduces a mathematical model that simulates the hemodynamic impact of congenital heart disease (CHD) during the fetal-to-neonatal transition, focusing on ventricular septal defect (VSD) and transposition of the great arteries (TGA). By integrating a one-fiber heart model and oxygen and carbon dioxide dynamics, the model gives a prediction of critical clinical parameters like flow, pressure, and oxygen saturation. This mathematical model has a potential to serve as non-invasive tool, providing valuable insights for prenatal planning and postnatal management, helping guide timely interventions for newborns affected by CHD.


  • Open Access

    A virtual population cohort approach for fetal cardiac valve modeling

    by Bettine G. van Willigen, Nick van Osta, M. Beatrijs van der Hout-Van der Jagt, Frans N. van de Vosse, Wouter Huberts

  • Open Access

    A Multiscale Mathematical Model for Fetal Gas Transport and Regulatory Systems During Second Half of Pregnancy

    by Bettine G. Van Willigen, M. Beatrijs van der Hout‐Van der Jagt, Wouter Huberts, Frans N. van de Vosse

    Fetal asphyxia, a condition resulting from the combined effects of hypoxia and hypercapnia, leads to approximately 900,000 annual deaths worldwide. One cause is umbilical cord compression during labor‐induced uterine contractions, disrupting the transport of metabolites to and from the placenta, and resulting in asphyxia. Current fetal well‐being assessment relies on monitoring fetal heart rate and uterine contractions as indicators of oxygen delivery to the brain. To enhance our understanding of this complex relationship, this study aims to develop a modular mathematical model including fetal blood gas dynamics, the autonomic nervous system, and cerebral blood flow regulation. The novelty of this study lies in the capability of the model to simulate fetal growth. These submodels are part of a larger multiscale mathematical model describing fetal circulation in the second half of pregnancy. The blood gas model realistically replicates partial oxygen and carbon dioxide pressures in umbilical arteries and veins during healthy fetal development reported in the literature. An in silico experiment is conducted to simulate umbilical cord occlusion and is compared with lamb experiments to verify the realism of the regulation models during fetal growth. Our findings suggest that premature infants are more susceptible to umbilical cord occlusion, exhibiting elevated cerebral perfusion pressure and flow. This modular mathematical model may serve as a valuable tool for testing hypotheses related to the fetal regulatory system.


  • Open Access

    A Multiscale Mathematical Model for the Fetal Blood Circulation of the Second Half of Pregnancy

    by Bettine G. van Willigen, M. Beatrijs van der Hout‐Van der Jagt, Peter H. M. Bovendeerd, Wouter Huberts, Frans N. van de Vosse

    Doppler ultrasound is a commonly used method to assess hemodynamics of the fetal cardiovascular system and to monitor the well‐being of the fetus. Indices based on the velocity profile are often used for diagnosis. However, precisely linking these indices to specific underlying physiology factors is challenging. Several influences, including wave reflections, fetal growth, vessel stiffness, and resistance distal to the vessel, contribute to these indices. Understanding these data is essential for making informed clinical decisions. Mathematical models can be used to investigate the relation between velocity profiles and physiological properties. This study presents a mathematical model designed to simulate velocity wave propagation throughout the fetal cardiovascular system, facilitating the assessment of factors influencing velocity‐based indices. The model combines a one‐fiber model of the heart with a 1D wave propagation model describing the larger vessels of the circulatory system and a lumped parameter model for the microcirculation. Fetal growth from 20 to 40 weeks of gestational age is incorporated by adjusting cardiac and circulatory parameter settings according to scaling laws. The model's results, including cardiac function, cardiac output distribution, and volume distribution, show a good agreement with literature studies for a growing healthy fetus from 20 to 40 weeks. In addition, Doppler indices are simulated in various vessels and agree with literature as well. In conclusion, this study introduces a novel closed‐loop 0D‐1D mathematical model that has been verified against literature studies. This model offers a valuable platform for analyzing factors influencing velocity‐based indices in the fetal cardiovascular system.


  • Open Access

    A review study of fetal circulatory models to develop a digital twin of a fetus in a perinatal life support system

    by Bettine G. van Willigen, M. Beatrijs van der Hout-Van der Jagt, Wouter Huberts, Frans N. van de Vosse

    Background: Preterm birth is the main cause of neonatal deaths with increasing mortality and morbidity rates with decreasing GA at time of birth. Currently, premature infants are treated in neonatal intensive care units to support further development. However, the organs of, especially, extremely premature infants (born before 28 weeks of GA) are not mature enough to function optimally outside the womb. This is seen as the main cause of the high morbidity and mortality rates in this group. A liquid-filled incubator, a so-called PLS system, could potentially improve these numbers for extremely premature infants, since this system is designed to mimic the environment of the natural womb. To support the development and implementation of such a complex system and to interpret vital signals of the fetus during a PLS system operation, a digital twin is proposed. This mathematical model is connected with a manikin representing the digital and physical twin of the real-life PLS system. Before developing a digital twin of a fetus in a PLS system, its functional and technical requirements are defined and existing mathematical models are evaluated.Method and results: This review summarizes existing 0D and 1D fetal circulatory models that potentially could be (partly) adopted for integration in a digital twin of a fetus in a PLS system based on predefined requirements. The 0D models typically describe hemodynamics and/or oxygen transport during specific events, such as the transition from fetus to neonate. Furthermore, these models can be used to find hemodynamic differences between healthy and pathological physiological states. Rather than giving a global description of an entire cardiovascular system, some studies focus on specific organs or vessels. In order to analyze pressure and flow wave profiles in the cardiovascular system, transmission line or 1D models are used. As for now, these models do not include oxygen transport.Conclusion: This study shows that none of the models identified in literature meet all the requirements relevant for a digital twin of a fetus in a PLS system. Nevertheless, it does show the potential to develop this digital twin by integrating (parts) of models into a single model.


  • A predictive computational model to estimate myocardial temperature during intracoronary hypothermia in acute myocardial infarction

    by Bettine G. van Willigen, Luuk C. Otterspoor, Marcel van ’t Veer, Tilaï T. Rosalina, Nico H.J. Pijls, Frans N. van de Vosse

    Hypothermia, if provided before coronary reperfusion, reduces infarct size in animal models of acute myocardial infarction (AMI). Translation to humans has failed so far, because the target temperature is not reached in time within the endangered myocardium using systemic hypothermia method. Hence, a clinically applicable method has been developed to provide intracoronary hypothermia using cold saline, selectively infused locally into the infarct area. In this study, a lumped parameter model has been designed to support the clinical method and to describe this myocardial cooling process mathematically. This model is able to predict the myocardial temperature changes over time, which cannot be measured, based on the temperature and flow of the intracoronary injected cold saline and coronary arterial blood. It was validated using data from an isolated beating porcine heart model and applied on data from patients with AMI undergoing intracoronary hypothermia. In prospect, the computational model may be used as an assistive tool to calculate the patient specific flow rate and temperature of saline required for reliable achievement of the target myocardial temperature in the hypothermia enhanced clinical treatment of AMI.