Clara Barneo-Caragol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Clara Barneo-Caragol has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ignacio Vega-Naredo
Department of Morphology and Cell Biology, Faculty of Medicine, University of Oviedo, Oviedo 33006, Asturias, Spain, Spain
3 shared publications - Susana Rodríguez-González
Department of Morphology and Cell Biology, Faculty of Medicine, University of Oviedo, Av. Julián Clavería, S/n, 33006, Oviedo, Asturias, Spain
3 shared publications - Eduardo Martínez-Morillo
Laboratory of Medicine, Department of Clinical Biochemistry, Hospital Universitario Central de Asturias, Av. de Roma, S/n, 33011, Oviedo, Asturias, Spain
2 shared publications - Francisco V. Alvarez
Clinical Biochemistry, Laboratory Medicine, Hospital Universitario Central de Asturias, Avenida de Roma, s/n, 33011 Oviedo, Spain
2 shared publications - Paloma Lequerica-Fernández
Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Instituto Universitario de Oncología del Principado de Asturias (IUOPA), Universidad de Oviedo, C/Carretera de Rubín, s/n, 33011 Oviedo, Asturias, Spain
2 shared publications Ana Isabel Cillero Sánchez
Department of Clinical Biochemistry , Hospital Álvarez Buylla , Mieres , Asturias , Spain
1 shared publication
Latest Publications
- Open Access
- 20 October 2023
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 4 (4) , 419-424
Evaluation of DiaSorin Liaison® calprotectin fecal assay adapted for pleural effusion
Objectives: Calprotectin (CP) is a calcium and zinc binding protein that is widely measured on faecal samples but its determination in other biological fluids might be of interest. The aim of this work was to validate the measurement of CP in pleural fluid by chemiluminescence. Methods: LIAISON®XL, a fully automated chemiluminescence analyzer, was used for CP quantification on pleural fluid. A validation protocol was designed using both quality control materials provided by the manufacturer and pools of pleural fluid samples. Stability, imprecision, bias, linearity, detection capability and carry over effect were evaluated. Results: CP was stable on pleural fluid at least one week, under refrigerated conditions, and four weeks at −80 °C. The observed intra- and inter-day imprecision was between 2.2 and 6.49 %, with a negative bias under 5.51 %. The linearity of the method was verified up to 2,000 ng/mL. The LoQ for the assay was 48.52 ng/mL. A statistically significant carry-over effect was observed after measuring CP concentrations above the upper limit of linearity, but given the observed magnitude, a clinically relevant impact should not be expected. Conclusions: DiaSorin Liaison® calprotectin assay allows reliable measurement of CP in pleural fluid.
- 20 October 2023
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 4 (4) , 419-424
Open AccessEvaluation of DiaSorin Liaison® calprotectin fecal assay adapted for pleural effusion
Objectives: Calprotectin (CP) is a calcium and zinc binding protein that is widely measured on faecal samples but its determination in other biological fluids might be of interest. The aim of this work was to validate the measurement of CP in pleural fluid by chemiluminescence. Methods: LIAISON®XL, a fully automated chemiluminescence analyzer, was used for CP quantification on pleural fluid. A validation protocol was designed using both quality control materials provided by the manufacturer and pools of pleural fluid samples. Stability, imprecision, bias, linearity, detection capability and carry over effect were evaluated. Results: CP was stable on pleural fluid at least one week, under refrigerated conditions, and four weeks at −80 °C. The observed intra- and inter-day imprecision was between 2.2 and 6.49 %, with a negative bias under 5.51 %. The linearity of the method was verified up to 2,000 ng/mL. The LoQ for the assay was 48.52 ng/mL. A statistically significant carry-over effect was observed after measuring CP concentrations above the upper limit of linearity, but given the observed magnitude, a clinically relevant impact should not be expected. Conclusions: DiaSorin Liaison® calprotectin assay allows reliable measurement of CP in pleural fluid.
- 1 July 2019
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 138, 1-9
Increased serum strontium levels and altered oxidative stress status in early-onset preeclampsia
- 1 July 2019
- Published by Elsevier in Free Radical Biology and Medicine
- Vol. 138, 1-9
Increased serum strontium levels and altered oxidative stress status in early-onset preeclampsia
- 1 May 2018
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 47, 37-44
Strontium and its role in preeclampsia
- 1 May 2018
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 47, 37-44
Strontium and its role in preeclampsia
- 1 January 2018
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 45, 57-63
Strontium and oxidative stress in normal pregnancy
- 1 January 2018
- Published by Elsevier in Journal of Trace Elements in Medicine and Biology
- Vol. 45, 57-63
Strontium and oxidative stress in normal pregnancy