Daniel Habor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel Habor has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Juliana Marotti
Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Aachen, Germany
2 shared publications - Klaus Radermacher
Chair of Medical Engineering, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany
2 shared publications - Lauren Bohner
Department of Cranio‐Maxillofacial Surgery University Hospital Muenster Muenster Germany
2 shared publications - Stefan Wolfart
Department of Prosthodontics and Biomaterials, Centre for Implantology Uniklinik RWTH Aachen Aachen Germany
2 shared publications - Sarah Neuhaus
Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany
1 shared publication - Stefan Heger
Institute for Biomedical Engineering, Mannheim University, John-Deere-Strasse 85, 68163 Mannheim, Germany
1 shared publication
Latest Publications
- Open Access
- 14 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5494
Scanning of a Dental Implant with a High-Frequency Ultrasound Scanner: A Pilot Study
The purpose of this in vitro study was to assess the trueness of a dental implant scanned using an intraoral high-frequency ultrasound prototype and compared with conventional optical scanners. An acrylic resin cast containing a dental implant at position 11 was scanned with a fringe projection 3D sensor for use as a reference dataset. The same cast was scanned 10 times for each group. Ultrasound scanning was performed with a high-frequency probe (42 MHz, aperture diameter of 4 mm and focus length of 8 mm), and 3D images were reconstructed based on the depth of each surface point echo. Optical scans were performed in a laboratory and with an intraoral scanner. A region of interest consisting of the dental implant site was segmented and matched to the reference dataset. Trueness was defined as the closeness between experimental data and the reference surface. Statistical analysis was performed with one-way ANOVA and post-hoc tests with a significance level of p = 0.05. No statistical difference was found among the evaluated scanners. The mean deviation error was 57.40 ± 17.44 µm for the ultrasound scanner, 75.40 ± 41.43 µm for the laboratory scanner and 38.55 ± 24.34 µm for the intraoral scanner. The high-frequency ultrasound scanner showed similar trueness to optical scanners for digital implant impression.
- 14 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5494
Open AccessScanning of a Dental Implant with a High-Frequency Ultrasound Scanner: A Pilot Study
The purpose of this in vitro study was to assess the trueness of a dental implant scanned using an intraoral high-frequency ultrasound prototype and compared with conventional optical scanners. An acrylic resin cast containing a dental implant at position 11 was scanned with a fringe projection 3D sensor for use as a reference dataset. The same cast was scanned 10 times for each group. Ultrasound scanning was performed with a high-frequency probe (42 MHz, aperture diameter of 4 mm and focus length of 8 mm), and 3D images were reconstructed based on the depth of each surface point echo. Optical scans were performed in a laboratory and with an intraoral scanner. A region of interest consisting of the dental implant site was segmented and matched to the reference dataset. Trueness was defined as the closeness between experimental data and the reference surface. Statistical analysis was performed with one-way ANOVA and post-hoc tests with a significance level of p = 0.05. No statistical difference was found among the evaluated scanners. The mean deviation error was 57.40 ± 17.44 µm for the ultrasound scanner, 75.40 ± 41.43 µm for the laboratory scanner and 38.55 ± 24.34 µm for the intraoral scanner. The high-frequency ultrasound scanner showed similar trueness to optical scanners for digital implant impression.
- Open Access
- 25 September 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (10) , 1539
High-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness
Purpose: The aim of this study was to evaluate the accuracy of high-frequency ultrasound (HFUS) for measurement of bone thickness surrounding dental implants. Methods: Eight porcine bone samples containing dental implants were scanned by a HFUS scanner and compared using cone-beam computed tomography (CBCT) and an optical scanner. Bone thickness was measured in the buccolingual region of dental implants in 10 points distributed between the platform and apical portion of the implant. Results: The mean measurement error for the ultrasound method was 0.11 mm, whereas CBCT showed a measurement error of 0.20 mm. For both devices, the maximal measurement error was 0.28 mm. Conclusion: Within the simulated limited conditions of this study, high-frequency ultrasound, with optical scanning used as a reference, presented higher accuracy in comparison to CBCT, and seems to be a promising tool for measuring peri-implant bone.
- 25 September 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (10) , 1539
Open AccessHigh-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness
Purpose: The aim of this study was to evaluate the accuracy of high-frequency ultrasound (HFUS) for measurement of bone thickness surrounding dental implants. Methods: Eight porcine bone samples containing dental implants were scanned by a HFUS scanner and compared using cone-beam computed tomography (CBCT) and an optical scanner. Bone thickness was measured in the buccolingual region of dental implants in 10 points distributed between the platform and apical portion of the implant. Results: The mean measurement error for the ultrasound method was 0.11 mm, whereas CBCT showed a measurement error of 0.20 mm. For both devices, the maximal measurement error was 0.28 mm. Conclusion: Within the simulated limited conditions of this study, high-frequency ultrasound, with optical scanning used as a reference, presented higher accuracy in comparison to CBCT, and seems to be a promising tool for measuring peri-implant bone.