Yunfeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yunfeng Zhang has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Linpei Dong
Institute of Forensic Science, Ministry of Public Security, Beijing, China
6 shared publicationsJifen Wang
School of investigation, People’s Public Security University of China, Beijing, China
5 shared publicationsPeng Zhao
Institute of Forensic Science, Ministry of Public Security, Beijing, China
5 shared publicationsXiaojun Wu
Institute of Forensic Science, Ministry of Public Security, Beijing, China
5 shared publicationsAihua Wang
Institute of Forensic Science, Ministry of Public Security, Beijing, China
4 shared publicationsShihao Wu
School of investigation, People’s Public Security University of China, Beijing, China
4 shared publications
Latest Publications
- 26 November 2024
- Published by Springer Nature in Biological Trace Element Research
- Vol. 203 (3) , 1776-1785
Rapid Determination of Toxic Trace Metals As, Hg, Tl, and Pb in Hair by Monochromatic Excitation X-ray Fluorescence Spectrometry
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry emerges as a novel technique in trace element analysis, distinguished by its simplicity, rapidity, and efficiency. Its application in forensic toxicology has grown significantly for identifying toxic trace metals in biological samples. This study further expands its utility by developing a method for the rapid determination of arsenic (As), mercury (Hg), thallium (Tl), and lead (Pb) in hair samples. Calibration curves were established using analytical reference samples, and optimal detection conditions were determined and validated. The LODs for As, Hg, Tl, and Pb were 0.03, 0.03, 0.03, and 0.05 μg g−1, respectively. Method precision was evaluated through seven parallel analyses of samples within the concentration range of 0.27 to 20.051 μg g⁻1, with relative standard deviations (RSDs) consistently below 10%. The feasibility of the ME-XRF technique for forensic toxicology analysis was validated through the analysis of authentic poisoned hair samples collected from the animal experiment.
- 26 November 2024
- Published by Springer Nature in Biological Trace Element Research
- Vol. 203 (3) , 1776-1785
Rapid Determination of Toxic Trace Metals As, Hg, Tl, and Pb in Hair by Monochromatic Excitation X-ray Fluorescence Spectrometry
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry emerges as a novel technique in trace element analysis, distinguished by its simplicity, rapidity, and efficiency. Its application in forensic toxicology has grown significantly for identifying toxic trace metals in biological samples. This study further expands its utility by developing a method for the rapid determination of arsenic (As), mercury (Hg), thallium (Tl), and lead (Pb) in hair samples. Calibration curves were established using analytical reference samples, and optimal detection conditions were determined and validated. The LODs for As, Hg, Tl, and Pb were 0.03, 0.03, 0.03, and 0.05 μg g−1, respectively. Method precision was evaluated through seven parallel analyses of samples within the concentration range of 0.27 to 20.051 μg g⁻1, with relative standard deviations (RSDs) consistently below 10%. The feasibility of the ME-XRF technique for forensic toxicology analysis was validated through the analysis of authentic poisoned hair samples collected from the animal experiment.
- 16 September 2024
- Published by Elsevier in Forensic Science International
- Vol. 364, 112232
Degradation and preservation of nitrites in whole blood
- 16 September 2024
- Published by Elsevier in Forensic Science International
- Vol. 364, 112232
Degradation and preservation of nitrites in whole blood
- 28 September 2023
- Published by Springer Nature in Biological Trace Element Research
- Vol. 202 (6) , 2755-2763
Evaluation of Monochromatic Excitation X-ray Fluorescence Spectrometry for Rapid Thallium Detection in Biological Samples Using Animal Models
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is a novel technique for trace element analysis, characterized by its simplicity, rapidity, and low cost. The objective of this study was to evaluate the applicability of ME-XRF technique for the measurement of thallium in biological samples. Acute and subacute thallium poisoning experiments were conducted to simulate various scenarios, with blood, urine, and 10 distinct organs collected. Detection was initially performed using ME-XRF technique, followed by validation with inductively coupled plasma mass spectrometry (ICP-MS). Excellent agreement between ME-XRF and ICP-MS values was demonstrated by means of paired sample t-tests and intraclass correlation coefficients. Subsequently, the practical implementation of the proposed technique was demonstrated through an actual case study. In conclusion, this study validates ME-XRF as a suitable alternative to ICP-MS for the measurement of trace heavy metals in biological samples. These efforts promote the development of simpler and faster techniques for heavy metal detection, thereby presenting novel avenues for the prevention and diagnosis of heavy metal poisoning.
- 28 September 2023
- Published by Springer Nature in Biological Trace Element Research
- Vol. 202 (6) , 2755-2763
Evaluation of Monochromatic Excitation X-ray Fluorescence Spectrometry for Rapid Thallium Detection in Biological Samples Using Animal Models
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is a novel technique for trace element analysis, characterized by its simplicity, rapidity, and low cost. The objective of this study was to evaluate the applicability of ME-XRF technique for the measurement of thallium in biological samples. Acute and subacute thallium poisoning experiments were conducted to simulate various scenarios, with blood, urine, and 10 distinct organs collected. Detection was initially performed using ME-XRF technique, followed by validation with inductively coupled plasma mass spectrometry (ICP-MS). Excellent agreement between ME-XRF and ICP-MS values was demonstrated by means of paired sample t-tests and intraclass correlation coefficients. Subsequently, the practical implementation of the proposed technique was demonstrated through an actual case study. In conclusion, this study validates ME-XRF as a suitable alternative to ICP-MS for the measurement of trace heavy metals in biological samples. These efforts promote the development of simpler and faster techniques for heavy metal detection, thereby presenting novel avenues for the prevention and diagnosis of heavy metal poisoning.
- 31 August 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (10) , 2127-2133
Simultaneous detection of trace As, Hg, Tl, and Pb in biological tissues using monochromatic excitation X-ray fluorescence spectrometry
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is an emerging technique for elemental analysis with many potential forensic applications. In this study, a method for rapid and efficient quantification of As, Hg, Tl, and Pb in biological tissues using ME-XRF was established and applied to actual cases. The instrument's operating conditions were optimized, and the optimum method for sample preparation was determined. According to the calibration curves of each element, a new model for the detection of biological tissues was developed based on the fundamental parameter (FP) method. The LOD values of As, Hg, Tl, and Pb were 0.04, 0.04, 0.06, and 0.07 μg g−1, respectively. Through systematic evaluation and validation, the feasibility of using ME-XRF in forensic toxicology analysis was confirmed.
- 31 August 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (10) , 2127-2133
Simultaneous detection of trace As, Hg, Tl, and Pb in biological tissues using monochromatic excitation X-ray fluorescence spectrometry
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is an emerging technique for elemental analysis with many potential forensic applications. In this study, a method for rapid and efficient quantification of As, Hg, Tl, and Pb in biological tissues using ME-XRF was established and applied to actual cases. The instrument's operating conditions were optimized, and the optimum method for sample preparation was determined. According to the calibration curves of each element, a new model for the detection of biological tissues was developed based on the fundamental parameter (FP) method. The LOD values of As, Hg, Tl, and Pb were 0.04, 0.04, 0.06, and 0.07 μg g−1, respectively. Through systematic evaluation and validation, the feasibility of using ME-XRF in forensic toxicology analysis was confirmed.
- Open Access
- 17 July 2023
- Published by Springer Nature in Research Square
Evaluation of monochromatic excitation X-ray fluorescence spectrometry for rapid thallium detection in biological samples using animal models
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is a novel technique for trace element analysis, characterized by its simplicity, rapidity, and low cost. The objective of this study was to evaluate the applicability of ME-XRF technique for the measurement of thallium in biological samples. Acute and subacute thallium poisoning experiments were conducted to simulate various scenarios, with blood, urine, and 10 distinct organs collected. Detection was initially performed using ME-XRF technique, followed by validation with inductively coupled plasma mass spectrometry (ICP-MS). Excellent agreement between ME-XRF and ICP-MS values was demonstrated by means of paired sample t-tests and intraclass correlation coefficients. Subsequently, the practical implementation of the proposed technique was demonstrated through an actual case study. In conclusion, this study validates ME-XRF as a suitable alternative to ICP-MS for the measurement of trace heavy metals in biological samples. These efforts promote the development of simpler and faster techniques for heavy metal detection, thereby presenting novel avenues for the prevention and diagnosis of heavy metal poisoning.
- 17 July 2023
- Published by Springer Nature in Research Square
Open AccessEvaluation of monochromatic excitation X-ray fluorescence spectrometry for rapid thallium detection in biological samples using animal models
Monochromatic excitation X-ray fluorescence (ME-XRF) spectrometry is a novel technique for trace element analysis, characterized by its simplicity, rapidity, and low cost. The objective of this study was to evaluate the applicability of ME-XRF technique for the measurement of thallium in biological samples. Acute and subacute thallium poisoning experiments were conducted to simulate various scenarios, with blood, urine, and 10 distinct organs collected. Detection was initially performed using ME-XRF technique, followed by validation with inductively coupled plasma mass spectrometry (ICP-MS). Excellent agreement between ME-XRF and ICP-MS values was demonstrated by means of paired sample t-tests and intraclass correlation coefficients. Subsequently, the practical implementation of the proposed technique was demonstrated through an actual case study. In conclusion, this study validates ME-XRF as a suitable alternative to ICP-MS for the measurement of trace heavy metals in biological samples. These efforts promote the development of simpler and faster techniques for heavy metal detection, thereby presenting novel avenues for the prevention and diagnosis of heavy metal poisoning.
- 15 November 2022
- Published by Elsevier in Legal Medicine
- Vol. 60, 102175
Ethyl sulfate in blood shows the potential to distinguish alcoholic death and postmortem alcohol instillation
- 15 November 2022
- Published by Elsevier in Legal Medicine
- Vol. 60, 102175
Ethyl sulfate in blood shows the potential to distinguish alcoholic death and postmortem alcohol instillation
- Open Access
- 4 July 2022
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 40 (2) , 182-189
Simultaneous determination of 36 hypotensive drugs in fingerprints by ultra performance liquid chromatography-triple quadrupole composite linear ion trap mass spectrometry
Fingerprints contain important information such as the ingredients ingested by the donor. By analyzing the characteristic components in fingerprints, the donor can be characterized, which would provide insights for investigation of a given case. This approach can also be used in the qualitative monitoring of drug intake. Therefore, the examination of hypotensive drugs in fingerprints has significant value in practical application. This study established a method based on ultra performance liquid chromatography-triple quadrupole composite linear ion trap mass spectrometry (UPLC-Q-TRAP/MS) for the simultaneous determination of 36 hypotensive drugs in fingerprints. The pre-treatment method was based on protein precipitation. A 3 x 3 cm filter paper was cut into pieces and placed in a 2 mL plastic centrifuge tube after fingerprint collection. Then, 0.50 mL methanol was added, followed by vortex mixing for 1 min and ultrasonic oscillation for 3 min. The filter paper was centrifuged at 12 000 r/min for 5 min, and the supernatant was withdrawn for sample analysis. An ACQUITY UPLC (R) BEH C18 chromatographic column (100 mmx3. 0 mm, 1. 7 mu m) was selected, with 0. 01% aqueous formic acid and methanol as mobile phases for gradient elution. MS analysis involved scheduled multiple reaction monitoring-information dependent acquisition-enhanced product ion (SMRM-IDA-EPI) scanning. This method could be used to retrieve library researching during high-sensitivity analysis, which could increase the accuracy of qualitative results. The calibration curves showed good linearity in the range of 0. 05-50. 00 ng/fingerprint, with correlation coefficients (r) greater than 0. 99 for all 36 analytes. The limits of detection and limits of quantification of the 36 hypotensive drugs were 0. 001-0. 045 ng/fingerprint and 0. 002-0. 050 ng/fingerprint, respectively. At spiked levels of 0. 25, 2. 50, 25. 00 ng/fingerprint, the matrix effects, recoveries, intra-day precisions, and inter-day precisions of the 36 hypotensive drugs were 79. 0% - 119. 2%, 79. 3% - 116. 2%, 0. 2% - 18. 3%, and 1. 6% - 19. 1%, respectively. This method was used to detect hypotensive drugs in the fingerprints of 87 hypertensive patients, and hypotensive drug intakes were accurately detected in most cases. The established method is operationally simple, with high sensitivity and good selectivity, and it is suitable for screening and testing hypotensive drugs in fingerprints.
- 4 July 2022
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 40 (2) , 182-189
Open AccessSimultaneous determination of 36 hypotensive drugs in fingerprints by ultra performance liquid chromatography-triple quadrupole composite linear ion trap mass spectrometry
Fingerprints contain important information such as the ingredients ingested by the donor. By analyzing the characteristic components in fingerprints, the donor can be characterized, which would provide insights for investigation of a given case. This approach can also be used in the qualitative monitoring of drug intake. Therefore, the examination of hypotensive drugs in fingerprints has significant value in practical application. This study established a method based on ultra performance liquid chromatography-triple quadrupole composite linear ion trap mass spectrometry (UPLC-Q-TRAP/MS) for the simultaneous determination of 36 hypotensive drugs in fingerprints. The pre-treatment method was based on protein precipitation. A 3 x 3 cm filter paper was cut into pieces and placed in a 2 mL plastic centrifuge tube after fingerprint collection. Then, 0.50 mL methanol was added, followed by vortex mixing for 1 min and ultrasonic oscillation for 3 min. The filter paper was centrifuged at 12 000 r/min for 5 min, and the supernatant was withdrawn for sample analysis. An ACQUITY UPLC (R) BEH C18 chromatographic column (100 mmx3. 0 mm, 1. 7 mu m) was selected, with 0. 01% aqueous formic acid and methanol as mobile phases for gradient elution. MS analysis involved scheduled multiple reaction monitoring-information dependent acquisition-enhanced product ion (SMRM-IDA-EPI) scanning. This method could be used to retrieve library researching during high-sensitivity analysis, which could increase the accuracy of qualitative results. The calibration curves showed good linearity in the range of 0. 05-50. 00 ng/fingerprint, with correlation coefficients (r) greater than 0. 99 for all 36 analytes. The limits of detection and limits of quantification of the 36 hypotensive drugs were 0. 001-0. 045 ng/fingerprint and 0. 002-0. 050 ng/fingerprint, respectively. At spiked levels of 0. 25, 2. 50, 25. 00 ng/fingerprint, the matrix effects, recoveries, intra-day precisions, and inter-day precisions of the 36 hypotensive drugs were 79. 0% - 119. 2%, 79. 3% - 116. 2%, 0. 2% - 18. 3%, and 1. 6% - 19. 1%, respectively. This method was used to detect hypotensive drugs in the fingerprints of 87 hypertensive patients, and hypotensive drug intakes were accurately detected in most cases. The established method is operationally simple, with high sensitivity and good selectivity, and it is suitable for screening and testing hypotensive drugs in fingerprints.
- 23 September 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (1) , e9199
Quantitative analysis of 17 hypoglycemic drugs in fingerprints using ultra‐high‐performance liquid chromatography/tandem hybrid triple quadrupole linear ion trap mass spectrometry
Rationale: The objective of this study was to develop, optimize, and validate a method for the determination and quantification of 17 hypoglycemic drugs in fingerprints using ultra‐high‐performance liquid chromatography/tandem hybrid triple quadrupole linear ion trap mass spectrometry (UHPLC/QTRAP‐MS/MS). We also aimed to apply the present method to the fingerprints collected from patients with hyperglycemia. Methods: The scheduled multiple reaction monitoring information‐dependent acquisition‐enhanced product ion (SMRM‐IDA‐EPI) scanning mode was utilized. The chromatographic system consisted of an Acquity UHPLC® BEH C18 column (3.0 × 100 mm, 1.7 μm) and a mobile phase of 0.01% (v/v) formic acid in water and methanol. Analytes were extracted via a precipitation protein procedure. The method was validated in accordance with the US Food and Drug Administration (FDA) guidance and applied to the analysis of fingerprint deposits from subjects who had taken the drugs. Results: The limits of detection (LODs) and the lower limits of quantification (LLOQs) of 17 hypoglycemic drugs were 0.001 to 0.020 and 0.002 to 0.050 ng/fingerprint, respectively. The correlation coefficients ( r ) for the calibration curves were > 0.99 in the range of 0.050–50.000 ng/fingerprint. The matrix effect and recovery of 17 hypoglycemic drugs at three concentrations ranged from 81.1 to 117.3% and 80.0 to 109.6%, respectively. The validation data (intra‐ and inter‐day combined) for accuracy ranged from 85.5 to 117.2%, the CV (%) data were ≤19.7%. All analytes were found to be stable stored in the autosampler (4°C) for 24 h. This validated method was successfully applied to detect hypoglycemic drugs in fingerprints from patients with hyperglycemia. Conclusions: A quantification method for hypoglycemic drugs in fingerprints was developed, optimized, and validated. This sensitive method could be used for drug monitoring and providing reference information in forensic investigations.
- 23 September 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 36 (1) , e9199
Quantitative analysis of 17 hypoglycemic drugs in fingerprints using ultra‐high‐performance liquid chromatography/tandem hybrid triple quadrupole linear ion trap mass spectrometry
Rationale: The objective of this study was to develop, optimize, and validate a method for the determination and quantification of 17 hypoglycemic drugs in fingerprints using ultra‐high‐performance liquid chromatography/tandem hybrid triple quadrupole linear ion trap mass spectrometry (UHPLC/QTRAP‐MS/MS). We also aimed to apply the present method to the fingerprints collected from patients with hyperglycemia. Methods: The scheduled multiple reaction monitoring information‐dependent acquisition‐enhanced product ion (SMRM‐IDA‐EPI) scanning mode was utilized. The chromatographic system consisted of an Acquity UHPLC® BEH C18 column (3.0 × 100 mm, 1.7 μm) and a mobile phase of 0.01% (v/v) formic acid in water and methanol. Analytes were extracted via a precipitation protein procedure. The method was validated in accordance with the US Food and Drug Administration (FDA) guidance and applied to the analysis of fingerprint deposits from subjects who had taken the drugs. Results: The limits of detection (LODs) and the lower limits of quantification (LLOQs) of 17 hypoglycemic drugs were 0.001 to 0.020 and 0.002 to 0.050 ng/fingerprint, respectively. The correlation coefficients ( r ) for the calibration curves were > 0.99 in the range of 0.050–50.000 ng/fingerprint. The matrix effect and recovery of 17 hypoglycemic drugs at three concentrations ranged from 81.1 to 117.3% and 80.0 to 109.6%, respectively. The validation data (intra‐ and inter‐day combined) for accuracy ranged from 85.5 to 117.2%, the CV (%) data were ≤19.7%. All analytes were found to be stable stored in the autosampler (4°C) for 24 h. This validated method was successfully applied to detect hypoglycemic drugs in fingerprints from patients with hyperglycemia. Conclusions: A quantification method for hypoglycemic drugs in fingerprints was developed, optimized, and validated. This sensitive method could be used for drug monitoring and providing reference information in forensic investigations.
- 1 June 2021
- Published by Elsevier in Journal of Chromatography B
- Vol. 1175, 122496
Simultaneous determination and quantitation of hypolipidemic drugs in fingerprints by UPLC-Q-TRAP/MS
- 1 June 2021
- Published by Elsevier in Journal of Chromatography B
- Vol. 1175, 122496
Simultaneous determination and quantitation of hypolipidemic drugs in fingerprints by UPLC-Q-TRAP/MS
- 1 January 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 193, 113714
Determination of propofol in human plasma with C18 pipette-tip based solid-phase extraction followed by liquid chromatography atmospheric-pressure chemical ionization tandem mass spectrometry analysis
- 1 January 2021
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 193, 113714
Determination of propofol in human plasma with C18 pipette-tip based solid-phase extraction followed by liquid chromatography atmospheric-pressure chemical ionization tandem mass spectrometry analysis