KSKerstin Stock

Kerstin Stock

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kerstin Stock has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Closed reduction in distal radius fractures: manual manipulation vs. finger trap traction—a prospective randomized controlled clinical trial

    by Stefan Benedikt, Lukas Horling, Simone Bode, Kerstin Stock, Gernot Schmidle, Rohit Arora

  • Open Access

    Long-term results of thumb carpometacarpal joint arthrodesis

    by Pascal Vogler, Stefan Benedikt, Simone Bode, Alexander Keiler, Kerstin Stock, Rohit Arora

    Introduction: Thumb carpometacarpal (CMC 1) arthrodesis remains an established treatment option for patients with high functional demands and strength requirements. Long-term data on mobility, complication rates and clinical outcomes remain limited. This study aimed to analyze long-term clinical and radiological results after CMC 1 arthrodesis. Materials and methods: A single-center, retrospective study included patients who underwent CMC 1 arthrodesis between 2004 and 2024. Following medical record analysis, eligible patients were invited to a standardized clinical and radiological follow-up examination. Outcomes included DASH, PRWHE and MHQ scores, pain intensity, mobility, strength and patient satisfaction. Radiological assessment covered fusion signs, implant position and adjacent joint arthrosis. The median follow-up was 9 years. Results: 34 patients were included, 16 participated in follow-up. The median DASH score was 14 points, PRWHE 4 points and MHQ 80 (operated) vs. 84 (contralateral). Grip strength reached 85% of the contralateral side, with preserved pinch strength. Compensatory adaptation of adjacent joints was observed regarding range of motion. Patients reported no relevant resting pain and only minimal load-related discomfort. 15 of 16 patients were satisfied with the outcome. Non-union occurred in 4 of 34 cases (11.8%), associated with absent cancellous bone grafting or compression screws. Revision surgery was required in 3 patients, achieving bone consolidation and pain remission in all cases. Radiological follow-up revealed STT arthrosis in 27% of cases, without clinical relevance. Conclusion: CMC 1 arthrodesis demonstrates good long-term results with significant pain relief and high patient satisfaction. Mobility compensation and near-complete strength restoration were observed. Adjacent joint arthrosis occurred but remained largely asymptomatic. The use of cancellous bone grafting and compression screws is strongly recommended to reduce non-union risk. Arthrodesis proves a reliable surgical option, particularly for patients with high strength requirements.

  • Open Access

    The ulna osteotomy locking plate II in patients with ulnocarpal impaction syndrome: a retrospective evaluation

    by Stefan Benedikt, Ulrike Seeher, Moritz Stricker, Simone Bode, Kerstin Stock, Rohit Arora

    Introduction: Ulnocarpal impaction syndrome is one general cause of ulnar-sided wrist pain. If conservative therapy fails, various surgical procedures and different instruments and implants are available. The aim of this study was to evaluate the results of the ulna osteotomy locking (UOL) plate II from the manufacturer I.T.S. Materials and methods: Thirty-five cases (34 patients) with primary or secondary ulnar impaction syndrome treated with the UOL plate II were evaluated retrospectively. Demographic, radiologic and clinical data were collected focusing on the postoperative ulnar variance and the complication rate, especially non-unions and signs of implant failure. Results: Median age was 48 years, with 20 female and 15 male cases. The measured median postoperative ulnar variance was − 0.8 mm (Q1: − 2; Q3: 0). There was no case of a non-union or a postoperative infection. Postoperative complications included one case of secondary dislocation, one case of a neuroma of the dorsal branch of the ulnar nerve and one mild CRPS. A total of six cases wished for an implant removal in the follow-up, of which five complained about local irritation caused by the plate. Conclusions: The UOL plate II has proven to be a reliable option for ulnar shortening osteotomy with a low implant associated complication rate, especially no case of non-union. The occasional need for implant removal should be considered. Due to the retrospective study design, a prospective study comparing the UOL II plate to different plating systems would be desirable.

  • Open Access

    Three-Dimensional Bone-Image Synthesis with Generative Adversarial Networks

    by Christoph Angermann, Johannes Bereiter-Payr, Kerstin Stock, Gerald Degenhart, Markus Haltmeier

    Medical image processing has been highlighted as an area where deep-learning-based models have the greatest potential. However, in the medical field, in particular, problems of data availability and privacy are hampering research progress and, thus, rapid implementation in clinical routine. The generation of synthetic data not only ensures privacy but also allows the drawing of new patients with specific characteristics, enabling the development of data-driven models on a much larger scale. This work demonstrates that three-dimensional generative adversarial networks (GANs) can be efficiently trained to generate high-resolution medical volumes with finely detailed voxel-based architectures. In addition, GAN inversion is successfully implemented for the three-dimensional setting and used for extensive research on model interpretability and applications such as image morphing, attribute editing, and style mixing. The results are comprehensively validated on a database of three-dimensional HR-pQCT instances representing the bone micro-architecture of the distal radius.


  • Open Access

    Bone remodelling after scaphoid fractures: HR-pQCT, clinical and laboratory data from a prospective 1-year follow-up study

    by Stefan Benedikt, Kerstin Stock, Lukas Horling, Gernot Schmidle, Michael Schirmer, Gerald Degenhart, Michael Blauth, Claudia Lamina, Johannes Dominikus Pallua, Rohit Arora


  • Open Access

    Deep Convolutional Neural Networks Provide Motion Grading for High-Resolution Peripheral Quantitative Computed Tomography of the Scaphoid

    by Stefan Benedikt, Philipp Zelger, Lukas Horling, Kerstin Stock, Johannes Pallua, Michael Schirmer, Gerald Degenhart, Alexander Ruzicka, Rohit Arora

    In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.


  • Open Access

    Outcomes of distal ulna locking plate in management of unstable distal ulna fractures: a prospective case series

    by K. Stock, S. Benedikt, T. Kastenberger, P. Kaiser, R. Arora, P. Zelger, J. D. Pallua, G. Schmidle

    Introduction: Given the absence of a satisfying plate system to deal with multifragmentary or subcapital distal ulnar fractures, the Distal Ulna Locking Plate (DUL, I.T.S. GmbH, Graz, Austria) could become a useful treatment option. This study aimed to evaluate the results of this anatomically pre-contoured plate regarding patients with unstable or displaced distal ulnar fractures. Methods: In a prospective clinical trial, 20 patients (18 female, two male; mean age 70 years (24–91 years)) with unstable or displaced distal ulna fractures between December 2010 and August 2015 were analyzed. All patients were treated with open reduction and internal fixation using the DUL. They were evaluated at three follow-up appointments at 3, 6 and 12 months postoperatively regarding their bone healing, ulnar variance (UV), range of motion (ROM) and grip strength. Patient related outcomes were measured using the Disability of the Arm, Shoulder and Hand (DASH), the Patient Rated Wrist Evaluation (PRWE) questionnaires, and the Visual Analogue Scale (VAS). The results after one year were compared to the outcome of the healthy contralateral side. Results: All fractures treated with open reduction and internal fixation using the Distal Ulna Locking Plate healed within 6 months and showed stable ulnar variances after surgery. ROM (rotational plane 81.1 ± 9.0°, sagittal plane 55.1 ± 14.6°, frontal plane 33.0 ± 9.4°) and grip strength (18.7 ± 7.1 N) at the follow-up after 12 month had similar values compared with the uninjured side. The mean DASH score (36.4 ± 29.0), the PRWE-score (14.5 ± 27.0), and the VAS (at rest 0.5 ± 1.1, during activity 1.2 ± 2.4) after one year had no significant difference to the uninjured side. The surgeon’s overall satisfaction rate regarding plate handling reached 81.8%. Conclusion: Stabilization of unstable distal ulna fractures using the DUL restores nearly normal anatomy and function. Its pre-countered design, volar placement, and enhanced stability present a satisfying plate system. Trial registration: The trial was retrospectively Registered at www.clinicaltrials.gov on 16 December 2021 (Trial Registration Number: NCT05329012).


  • Open Access

    Surgical treatment of the bony mallet thumb: a case series and literature review

    by Tobias Kastenberger, Peter Kaiser, Stefan Benedikt, Kerstin Stock, Magdalena Eigl, Gernot Schmidle, Rohit Arora

    Introduction: The aim of this study was to provide a more precise statement on the outcome after surgical treatment of a bony mallet thumb and possibly give a treatment recommendation regarding the surgical fixation method. Patients and methods: All patients (n = 16) who underwent a surgical treatment for an acute bony mallet thumb fracture between January 2006 and July 2019 were enrolled. The surgical method, complications, the range of motion, tip pinch, lateral key pinch, overall grip strength, visual analog score, Disability of the Arm, Shoulder and Hand Score, Mayo Wrist Score, Patient-Rated Wrist Evaluation Score, Buck-Gramcko Score and radiologic parameters were evaluated. Further, a comprehensive literature search on PubMed was conducted covering a period from 1956 to 2021 to include all possible matching articles on the treatment of the bony mallet thumb (n = 21 articles). Results: Surgical treatment was very inhomogenous including indirect and direct K-wire fixation, screw fixation, plate fixation and anchor fixation methods. The IP joint range of motion and thumb strength ranged from 66 to 94% in comparison to the contralateral side. An open reduction led to worse functional scores compared to a closed reduction. Treatment methods in the literature were also very inhomogenous with a very low patient count, often even pooling data of bony mallet thumb fractures with bony mallet finger fractures. The risk for infection was higher in K-wire fixation methods than in open reduction and internal fixation methods. Conclusion: The evidence for the best treatment of a bony mallet thumb fracture is low. On one hand the functional outcome can be inferior using an open reduction approach, but on the other hand, K-wire fixation methods with a closed reduction approach showed a higher risk for infection. Future multi-center research must be conducted to find the best treatment procedure for the best outcome of the patient.


  • Open Access

    Lessons learned with the Cobra prosthesis in elderly patients with complex distal radius fractures—a retrospective follow-up study

    by Stefan Benedikt, Peter Kaiser, Gernot Schmidle, Tobias Kastenberger, Kerstin Stock, Rohit Arora

    Introduction: Recently, the Cobra prostheses were introduced in the treatment of distal radius fractures (DRF) of elderly patients. Fracture prostheses provide an alternative treatment option for complex fractures where conservative therapy seems not acceptable and osteosynthesis seems not possible. Data reporting the feasibility of the Cobra prosthesis are sparse. Therefore, this retrospective follow-up study investigated the clinical and radiological mid-term outcome of the Cobra implant in complex DRFs of elderly patients.Materials and methods: Thirteen patients (mean age 73.5 years, range 65–87 years) were retrospectively evaluated with at least a 1-year follow-up after surgery. Objective and subjective clinical parameters as well as the radiological outcome and complications were analyzed.Results: The mean follow-up period was 31.2 months. Seven cases required a cemented prosthesis. The mean relative range-of-motion compared to the healthy side was 72.3% and 51.8% for extension and flexion, respectively, and 87.9% and 85.7% for pronation and supination, respectively. The mean grip strength was 78.3% compared to the non-operated side. Eight patients were very satisfied, five patients were partly satisfied with the result. The DASH, PRWE, MHQ and Lyon-Scores averaged 39.1, 36.2, 64.9 and 63.3 points, respectively. The mean VAS-Score for pain was 1.1 at rest and 3.2 during activities. Perioperative complications included one dissection of the extensor pollicis longus tendon, one heterotopic ossification, one radiocarpal dislocation and two cases of an ulnar impaction syndrome due to implant subsidence.Conclusion: The prosthetic treatment of complex DRFs in elderly patients with the Cobra implant led to clinically and radiologically satisfactory mid-term results. The Cobra prosthesis still does not represent a gold standard but can be regarded as a feasible salvage option for complex DRFs when osteosyntheses may not be possible and non-operative treatment will lead to further functional restrictions and wrist pain during performing activities of daily life in high functional demand patients.


  • Open Access

    Mid-term follow-up of surgically treated and healed scaphoid fractures

    by P. Kaiser, G. Brueckner, T. Kastenberger, G. Schmidle, K. Stock, R. Arora