Lei Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Zhao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Kunyu Liao
Suzhou Power Supply Company, State Grid Jiangsu Electric Power Company Ltd., Suzhou, China
2 shared publicationsShun Tao
State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publicationsYunbo Liu
State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications- Dan Hu
State Grid Anhui Electric Power Research Institute, Hefei 230022, China
1 shared publication - Haijun Liu
China Electric Power Research Institute Co., Ltd., Beijing 100053, China
1 shared publication - Shengjun Zhou
China Electric Power Research Institute Co., Ltd., Beijing 100053, China
1 shared publication
Latest Publications
- Open Access
Harmonic and Interharmonic Measurement Method Using Two-Fold Compound Convolution Windows and Zoom Fast Fourier Transform
With the rapidly increasing penetration of new energy resources, the power grid faces significant threats from harmonics. To measure and suppress these harmonics, numerous harmonic measurement methods have been proposed. However, accurately identifying the parameters of harmonics and interharmonics remains challenging. To address this issue, we propose a new method that combines two-fold convolution windows and ZoomFFT. This method leverages the advantages of low side lobe peaks and high side lobe attenuation rates of compound convolution windows to suppress spectral leakage. Additionally, a six-spectral-line interpolation method is employed to correct the calculation results. Furthermore, ZoomFFT is utilized to locally amplify the spectrum, enabling the distinction between interharmonics and harmonics with closely spaced frequencies. The simulation results demonstrate that the proposed algorithm effectively identifies interharmonics with similar frequencies, outperforming single-window functions and ZoomFFT in terms of accuracy.
Open AccessHarmonic and Interharmonic Measurement Method Using Two-Fold Compound Convolution Windows and Zoom Fast Fourier Transform
With the rapidly increasing penetration of new energy resources, the power grid faces significant threats from harmonics. To measure and suppress these harmonics, numerous harmonic measurement methods have been proposed. However, accurately identifying the parameters of harmonics and interharmonics remains challenging. To address this issue, we propose a new method that combines two-fold convolution windows and ZoomFFT. This method leverages the advantages of low side lobe peaks and high side lobe attenuation rates of compound convolution windows to suppress spectral leakage. Additionally, a six-spectral-line interpolation method is employed to correct the calculation results. Furthermore, ZoomFFT is utilized to locally amplify the spectrum, enabling the distinction between interharmonics and harmonics with closely spaced frequencies. The simulation results demonstrate that the proposed algorithm effectively identifies interharmonics with similar frequencies, outperforming single-window functions and ZoomFFT in terms of accuracy.
- Open Access
- 19 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 114784-114794
Impedance Network Model of D-PMSG Based Wind Power Generation System Considering Wind Speed Variation for Sub-Synchronous Oscillation Analysis
Recently, sub-synchronous oscillation (SSO) issues were observed in direct-drive permanent magnet synchronous generator (D-PMSG) based wind power generation systems (WPGS) comprising multiple wind farms. Impedance model (IM) analysis has become an important method to study such problems. In this paper, an IM of a D-PMSG grid-connected system (GCS) is established considering the relationship between wind speed and wind turbine output power and the effect of voltage outer loop control. An impedance network model (INM) for a multi-wind-farm grid-connected system (MWFGS) is constructed with IMs of each wind turbine/farm and transmission lines according to the interconnection topology of them. Then, based on the IM of the D-PMSG-GCS, the influence of wind speed on the SSO characteristics is quantitatively analyzed, and the accuracy of the model is verified by comparing with the eigenvalue analysis results. Finally, the influencing factors such as distributed wind speed and network topology of MWFGS on SSO characteristics are quantitatively analyzed based on the INM, and the time-domain simulation verifications are performed in PSCAD/EMTDC. The results prove the effectiveness of INM in analyzing SSO problems of a large-scale WPGS. This is of great significance for the planning of large-scale D-PMSG-based WPGSs and the suppression of SSO.
- 19 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 114784-114794
Open AccessImpedance Network Model of D-PMSG Based Wind Power Generation System Considering Wind Speed Variation for Sub-Synchronous Oscillation Analysis
Recently, sub-synchronous oscillation (SSO) issues were observed in direct-drive permanent magnet synchronous generator (D-PMSG) based wind power generation systems (WPGS) comprising multiple wind farms. Impedance model (IM) analysis has become an important method to study such problems. In this paper, an IM of a D-PMSG grid-connected system (GCS) is established considering the relationship between wind speed and wind turbine output power and the effect of voltage outer loop control. An impedance network model (INM) for a multi-wind-farm grid-connected system (MWFGS) is constructed with IMs of each wind turbine/farm and transmission lines according to the interconnection topology of them. Then, based on the IM of the D-PMSG-GCS, the influence of wind speed on the SSO characteristics is quantitatively analyzed, and the accuracy of the model is verified by comparing with the eigenvalue analysis results. Finally, the influencing factors such as distributed wind speed and network topology of MWFGS on SSO characteristics are quantitatively analyzed based on the INM, and the time-domain simulation verifications are performed in PSCAD/EMTDC. The results prove the effectiveness of INM in analyzing SSO problems of a large-scale WPGS. This is of great significance for the planning of large-scale D-PMSG-based WPGSs and the suppression of SSO.
- Open Access
- 17 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 133159-133169
Probability Assessment of Characteristics of Sub-Synchronous Oscillation in D-PMSG-Based Wind Power Generation System
In recent years, sub-synchronous oscillation (SSO) phenomena occur in direct-drive permanent magnet synchronous generator (D-PMSG) based wind power generation systems (WPGS) in many regions of China. The SSO characteristics, frequency and damping, are all time-varying mostly affected by changes of wind speed and D-PMSGs number. It is the importance for the design of SSO suppression to know the variation ranges of characteristics and the risk of unstable SSO. The small signal model of the D-PMSG-based WPGS is firstly established in this paper, considering the functional relationship between wind speed and wind turbine output power. Based on the small signal model and the probability distribution function (PDF) of wind speed, the SSO probability assessment method with the least square method (LSM) polynomial fitting is then proposed. Therefore, the probability distributions of SSO frequency and damping considering wind speed variation are obtained efficiently. By PSCAD/EMTDC simulations and comparisons, the obtained results with the eigenvalue analysis method based on the small signal model are certificated. Then the probability assessment method is applied to study the influences of different average wind speeds under different number of D-PMSGs on the probability distribution of SSO frequency and damping. The changes of SSO frequency bandwidth and the risk of unstable SSO are depicted relative completely. The variation range of SSO frequency is consistent with the actual accident scenario in Hami area of Xinjiang, China.
- 17 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 133159-133169
Open AccessProbability Assessment of Characteristics of Sub-Synchronous Oscillation in D-PMSG-Based Wind Power Generation System
In recent years, sub-synchronous oscillation (SSO) phenomena occur in direct-drive permanent magnet synchronous generator (D-PMSG) based wind power generation systems (WPGS) in many regions of China. The SSO characteristics, frequency and damping, are all time-varying mostly affected by changes of wind speed and D-PMSGs number. It is the importance for the design of SSO suppression to know the variation ranges of characteristics and the risk of unstable SSO. The small signal model of the D-PMSG-based WPGS is firstly established in this paper, considering the functional relationship between wind speed and wind turbine output power. Based on the small signal model and the probability distribution function (PDF) of wind speed, the SSO probability assessment method with the least square method (LSM) polynomial fitting is then proposed. Therefore, the probability distributions of SSO frequency and damping considering wind speed variation are obtained efficiently. By PSCAD/EMTDC simulations and comparisons, the obtained results with the eigenvalue analysis method based on the small signal model are certificated. Then the probability assessment method is applied to study the influences of different average wind speeds under different number of D-PMSGs on the probability distribution of SSO frequency and damping. The changes of SSO frequency bandwidth and the risk of unstable SSO are depicted relative completely. The variation range of SSO frequency is consistent with the actual accident scenario in Hami area of Xinjiang, China.