Faiz Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Faiz Ali has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Zeid Abdullah Alothman
King Saud University
8 shared publications Mian Muhammad
6 shared publicationsWon Jo Cheong
Department of Chemistry, Inha University, Incheon, South Korea
6 shared publications- Mian Muhammad
Department of Chemistry, University of Malakand, Khyber Pakhtunkhwa, Pakistan
4 shared publications Musa Khan
Department of Chemistry, University of Malakand, Dir Lower, Chakdara, Pakistan
4 shared publicationsZeid A. AlOthman
4 shared publications
Latest Publications
- Open Access
- 26 March 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (19) , 17574-17590
A fluorometric chemosensor for the sequential determination of Fe( iii ) and cefotaxime sodium in water samples, serum and commercial formulations: a computational and an experimental approach
An indole-based chemosensor (P1) was synthesized and characterized using FT-IR and 1 H NMR and was investigated fluorometrically for the determination of various metal ions.
- 26 March 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (19) , 17574-17590
Open AccessA fluorometric chemosensor for the sequential determination of Fe( iii ) and cefotaxime sodium in water samples, serum and commercial formulations: a computational and an experimental approach
An indole-based chemosensor (P1) was synthesized and characterized using FT-IR and 1 H NMR and was investigated fluorometrically for the determination of various metal ions.
- Open Access
- 26 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (7) , 5956-5969
Nickel-containing 4,4′-biphenol mixed-mode stationary phase for the separation of polyaromatic compounds, benzene derivatives and nucleotides
A new mixed-mode hybrid stationary phase for the separation of polyaromatic compound, benzene derivatives and nucleotides.
- 26 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (7) , 5956-5969
Open AccessNickel-containing 4,4′-biphenol mixed-mode stationary phase for the separation of polyaromatic compounds, benzene derivatives and nucleotides
A new mixed-mode hybrid stationary phase for the separation of polyaromatic compound, benzene derivatives and nucleotides.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Silica-incorporated cisplatin-MIP: synthesis, characterization, and evaluation via liquid chromatography
A cisplatin molecular imprinted polymer was synthesized using methacrylic acid, silica particles, EGDMA, and AIBN as the functional monomer, crosslinker, and initiator, respectively.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Open AccessSilica-incorporated cisplatin-MIP: synthesis, characterization, and evaluation via liquid chromatography
A cisplatin molecular imprinted polymer was synthesized using methacrylic acid, silica particles, EGDMA, and AIBN as the functional monomer, crosslinker, and initiator, respectively.
- 7 November 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (2) , 1065-1074
Spectrophotometric Determination of Fluometuron Via Complexation with Fe(III): Method Development, Validation, and Application to Environmental Samples
A simple, cost-effective, accurate, and sensitive spectrophotometric method has been developed for the determination of fluometuron in environmental samples. The method is based on the formation of a metal complex between fluometuron and Fe(III), exhibiting maximum absorbance at 347 nm. The calibration curve followed Beer’s law in the concentration range of 0.25–5.0 µg mL− 1, with a correlation coefficient (R2) of 0.997, indicating excellent linearity. The method demonstrated a limit of detection (LOD) of 0.0787 µg mL− 1 and a limit of quantification (LOQ) of 0.238 µg mL− 1. Recovery studies performed on spiked environmental matrices showed high accuracy, with percent recoveries ranging from 82.12 ± 2.95% to 97.80 ± 6.11%. The developed method was successfully applied to the analysis of fluometuron in real samples, including tap water, canal water, pond water, and soil, confirming its reliability for routine environmental monitoring.
- 7 November 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (2) , 1065-1074
Spectrophotometric Determination of Fluometuron Via Complexation with Fe(III): Method Development, Validation, and Application to Environmental Samples
A simple, cost-effective, accurate, and sensitive spectrophotometric method has been developed for the determination of fluometuron in environmental samples. The method is based on the formation of a metal complex between fluometuron and Fe(III), exhibiting maximum absorbance at 347 nm. The calibration curve followed Beer’s law in the concentration range of 0.25–5.0 µg mL− 1, with a correlation coefficient (R2) of 0.997, indicating excellent linearity. The method demonstrated a limit of detection (LOD) of 0.0787 µg mL− 1 and a limit of quantification (LOQ) of 0.238 µg mL− 1. Recovery studies performed on spiked environmental matrices showed high accuracy, with percent recoveries ranging from 82.12 ± 2.95% to 97.80 ± 6.11%. The developed method was successfully applied to the analysis of fluometuron in real samples, including tap water, canal water, pond water, and soil, confirming its reliability for routine environmental monitoring.
- Open Access
- 1 September 2025
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 54 (1)
Immobilization of divinely benzene polymer on silica anchored graphene oxide for the efficient removal of acid yellow 25 and acid black 210
- 1 September 2025
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 54 (1)
Open AccessImmobilization of divinely benzene polymer on silica anchored graphene oxide for the efficient removal of acid yellow 25 and acid black 210
- 13 August 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (8) , 1-17
Silica-incorporated molecularly imprinted polymers for removal of acid black ATT via solid-phase extraction
- 13 August 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (8) , 1-17
Silica-incorporated molecularly imprinted polymers for removal of acid black ATT via solid-phase extraction
- Open Access
- 12 June 2025
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 53 (9)
Synthesis and characterization of Pd-doped carbon dots (CDP) for the photocatalytic degradation of imidacloprid
- 12 June 2025
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 53 (9)
Open AccessSynthesis and characterization of Pd-doped carbon dots (CDP) for the photocatalytic degradation of imidacloprid
- Open Access
- 23 October 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (46) , 34486-34497
A simple and cost-effective hybrid stationary phase for the separation of peptides, proteins and benzene derivatives through liquid chromatography
A very simple and cost-effective silica-based hybrid stationary phase was synthesized for the separation of five synthetic peptides, five proteins, and benzene derivatives. Silica monolith was synthesized via sol–gel process. Particles obtained through the grinding of silica monolith were suspended in methanol and sedimented under gravity to obtain sub-2 μm particles. A hybrid LC stationary phase was obtained by coating an ethylene glycol dimethacrylate co-polymer onto the particles via RAFT polymerization. The resultant stationary phase was characterized using SEM, FTIR, BET, and EDX analysis. A stainless steel column (200 mm long × 0.2 mm ID) was packed with the resultant stationary phase via pressure tapering protocol using a slurry packing machine. The column resulted in the average number of theoretical plates/meter (287 500 for synthetic peptides, 276 800 for proteins, and 226 100 for benzene derivatives) under the elution conditions of acetonitrile/50 mM ammonium format (68/32 v/v%) with a flow rate of 0.785 μL min−1. Since the column resulted in the separation of synthetic peptides, proteins, and benzene derivatives with very good chromatographic performance, it could possibly separate any complex mixture of peptides and proteins with better chromatographic performance.
- 23 October 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (46) , 34486-34497
Open AccessA simple and cost-effective hybrid stationary phase for the separation of peptides, proteins and benzene derivatives through liquid chromatography
A very simple and cost-effective silica-based hybrid stationary phase was synthesized for the separation of five synthetic peptides, five proteins, and benzene derivatives. Silica monolith was synthesized via sol–gel process. Particles obtained through the grinding of silica monolith were suspended in methanol and sedimented under gravity to obtain sub-2 μm particles. A hybrid LC stationary phase was obtained by coating an ethylene glycol dimethacrylate co-polymer onto the particles via RAFT polymerization. The resultant stationary phase was characterized using SEM, FTIR, BET, and EDX analysis. A stainless steel column (200 mm long × 0.2 mm ID) was packed with the resultant stationary phase via pressure tapering protocol using a slurry packing machine. The column resulted in the average number of theoretical plates/meter (287 500 for synthetic peptides, 276 800 for proteins, and 226 100 for benzene derivatives) under the elution conditions of acetonitrile/50 mM ammonium format (68/32 v/v%) with a flow rate of 0.785 μL min−1. Since the column resulted in the separation of synthetic peptides, proteins, and benzene derivatives with very good chromatographic performance, it could possibly separate any complex mixture of peptides and proteins with better chromatographic performance.
- Open Access
- 13 December 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (51) , 49115-49128
Development of Fluorescent Co (II)-Integrated Carbon Dots and Their Application as a Off–On Mesotrione Detection Sensor
A very simple mesotrione-sensing medium with enhanced sensitivity detection limits has been proposed. A renovated hydrothermal method was adopted for synthesizing fluorescent carbon dots from ethylenediamine and glucose using a Teflon-lined simple autoclave in a GC oven. The resultant carbon dots were characterized via TEM, FTIR, UV-vis, particle size distribution, and EDX and evaluated in a fluorimeter as the sensing medium for mesotrione detection. The binding approach of the Co (II)-integrated glucose-bound carbon dots toward mesotrione is selective, making them an effective sensor for the real sample applications, where majority of the coexisting substances showed insignificant interference effect. Formation of the metastable state due to the molecular interaction between carbon dots and Co (II) resulted in fluorescence quenching at 456 nm. Enhancement in the fluorescence intensity occurred when mesotrione was added in the concentration range of 0.2-5.0 μg mL-1, with a limit of detection, limit of quantification, standard deviation, and relative standard deviation of 0.054, 0.164, 0.00082 μg mL-1, and 0.682%, respectively. Mesotrione determination was demonstrated in soil, water, and tomato samples with recoveries in the range of 95.38-104.7%. The selectivity of the sensor was found to be good enough when checked for the complex tomato sample spiked with different pesticides of the triketone family having structural similarities to mesotrione.
- 13 December 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (51) , 49115-49128
Open AccessDevelopment of Fluorescent Co (II)-Integrated Carbon Dots and Their Application as a Off–On Mesotrione Detection Sensor
A very simple mesotrione-sensing medium with enhanced sensitivity detection limits has been proposed. A renovated hydrothermal method was adopted for synthesizing fluorescent carbon dots from ethylenediamine and glucose using a Teflon-lined simple autoclave in a GC oven. The resultant carbon dots were characterized via TEM, FTIR, UV-vis, particle size distribution, and EDX and evaluated in a fluorimeter as the sensing medium for mesotrione detection. The binding approach of the Co (II)-integrated glucose-bound carbon dots toward mesotrione is selective, making them an effective sensor for the real sample applications, where majority of the coexisting substances showed insignificant interference effect. Formation of the metastable state due to the molecular interaction between carbon dots and Co (II) resulted in fluorescence quenching at 456 nm. Enhancement in the fluorescence intensity occurred when mesotrione was added in the concentration range of 0.2-5.0 μg mL-1, with a limit of detection, limit of quantification, standard deviation, and relative standard deviation of 0.054, 0.164, 0.00082 μg mL-1, and 0.682%, respectively. Mesotrione determination was demonstrated in soil, water, and tomato samples with recoveries in the range of 95.38-104.7%. The selectivity of the sensor was found to be good enough when checked for the complex tomato sample spiked with different pesticides of the triketone family having structural similarities to mesotrione.