JGJin Ge

Jin Ge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jin Ge has a total of 192 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Piezochromic metal-organic framework films for interfacial pressure mapping

    by Lin Zheng, Jinhui Gu, Junshuai Chen, Jun-Zhe Dong, Jia-Sen Xie, Ying Yang, Mingwei Gu, Xingyu Ma, Mengxing Huang, Jin Ge, et al.

    Piezochromic metal-organic frameworks (MOFs) hold strong promise for interfacial pressure mapping owing to their structurally tunable sensitivity and sensing range. However, their practical deployment is hindered by structural instability during coating formation and under moisture exposure, as well as by the difficulty of obtaining color-uniform thin films. Herein, we report a solvent-exchange and encapsulation strategy that stabilizes MOF structures by weakening solvent-framework interactions and blocking moisture ingress, enabling highly stable piezochromic MOF films. Concurrently, highly color-uniform MOF films are realized through interfacial wettability regulation, enabling the identification of the surface roughness of 1000-grit sandpaper via pressure mapping. Moreover, the MOF coating process is adaptable to curved surfaces, allowing the recording of collision pressure distributions that are difficult to capture using electronic devices. This work demonstrates the great potential of piezochromic MOFs in film and coating formats for high-resolution interfacial pressure mapping.

  • Open Access

    Ionic conductivity and excitation frequency effects in iontronic pressure sensing

    by Yongming Wang, Jiasen Xie, Mingwei Gu, Ying Yang, Xingyu Ma, Lin Zheng, Junshuai Chen, Yunjie Lu, Jinhui Gu, Jin Ge

    Iontronic pressure sensors, which combine high sensitivity, superior signal stability, and resistance to electromagnetic interference, are regarded as promising candidates for next-generation pressure sensing systems. However, the roles of ionic conductivity and excitation frequency in determining sensing behavior remains unknown. Here, we employ an ionic-droplet-based research model to elucidate these effects through electrochemical impedance spectroscopy (EIS). Based on the equivalent circuit, we derived equations that link apparent capacitance change to ionic conductivity and excitation frequency. The equations reveal that droplet compression leads to larger apparent capacitance variation at lower ionic conductivity and higher excitation frequency, consistent with our experimental observations. Accordingly, tuning these parameters alone enhances the sensitivity of the droplet-based pressure sensor by up to 8772% without any structural modification. Under the optimized conditions, the sensor delivers highly repeatable pressure responses. Integrated into a robotic arm, it enables real-time pressure detection and discrimination of materials with different softness levels. By substituting ionic-droplets with hydrogels, the sensing model is successfully extended to solid-state ionic materials. A hydrogel sensor array of 4 × 4 with a pixel size of 2 mm is fabricated, enabling spatial pressure mapping. These findings provide new design principles for elastic ionic materials and underscore the critical role of measurement parameters in determining the sensing behavior of ionic sensing systems.


  • Open Access

    Synthetic materials trained tactile sensing enables quantitative perception of Young’s modulus and Poisson’s ratio

    by Jiasen Xie, Xingyue Liu, Yongming Wang, Ying Yang, Mingwei Gu, Xingyu Ma, Lin Zheng, Yunjie Lu, Jin-Hui Gu, Junshuai Chen, et al.

    Accurately perceiving object softness remains challenging for tactile sensors, as current approaches estimate Young's modulus from object deformation in response to an applied pressure while overlooking the pivotal role of Poisson's ratio in shaping that deformation. Here we present a tactile sensor that quantitatively and accurately detects both Young's modulus and Poisson's ratio, achieved by constructing a broad materials library spanning diverse Young's modulus-Poisson's ratio and capturing materials' surface bulging height-pressure trajectories. Using these trajectories as machine-learning features, our sensor achieved 84.7% anti-error rate assessment (ARA) in predicting Young's modulus, markedly higher than 73.3% using pressure-bulging height pairs, and, for the first time, enabled quantitative inference of Poisson's ratio with 87.7% ARA. Kendall's Tau analysis verified a Young's modulus ranking ARA of 91.3% for our sensor, outperforming conventional approaches (66.8%). The mechanistic influence of Poisson's ratio on bulging morphology was revealed via a materials-library-enabled univariate experimental strategy combined with finite element simulations. When deployed on a robotic manipulator, the sensor generalizes to unseen samples, enabling accurate perception of Young's modulus across diverse materials and heralding a new paradigm for next-generation tactile sensing.

  • Precise perception of surface tackiness enabled by a soft single-sensing-element tactile sensor

    by Ying Yang, Mingwei Gu, Jia-Sen Xie, Xingyu Ma, Yan-Na Lu, Lin Zheng, Jinhui Gu, Junshuai Chen, Yunjie Lu, Denys Makarov, et al.


  • Open Access

    Scalable solution soaking quenching technique unlocks efficient and durable wide bandgap perovskite solar modules

    by Yuxuan Fang, Jinglin Sun, Ying Tan, Guo Yang, Huanyu Chen, Mingwei Gu, Yongbin Feng, Meifang Yang, Hong Liu, Jun Fang, et al.

    Wide-bandgap mixed-halide perovskite photovoltaic modules show strong potential for portable chargers, building-integrated photovoltaics, agrivoltaics, and tandem systems, but large-area processing exacerbates crystallization heterogeneity, surface defects, and halide phase segregation. Conventional spin-coating passivation fails to deliver uniform interfacial control at scale. Here, an industrially inspired solution-soaking quenching technique is introduced, in which hot blade-coated wide-bandgap perovskite films ( ~ 30 cm2) are immersed in cold SrI2/isopropanol. It enables rapid surface reconstruction and uniform surface passivation, enhances photoluminescence uniformity, improves crystallinity, reduces roughness, and stabilizes halides via gradient Sr2+ incorporation. These effects mitigate tensile stress, optimize energy-level alignment, and suppress light-induced phase separation. Methylammonium-free wide-bandgap small-area (0.04 cm2) devices achieve efficiencies up to 22.03%, while a 10.13 cm2 module delivers 20.32% efficiency with excellent operational stability. The method is versatile across wide-bandgap perovskite compositions and enables practical applications including portable chargers, semitransparent modules (18.41% bifacial equivalent efficiency), and >27% efficient all-perovskite tandem windows.


  • Bistricyclic aromatic enes with fast conformational transition for ultrathin piezochromic films

    by Xiang-Ru Liu, Yihao Yin, Xian-Xian Xiao, Lin Zheng, Yan-Na Lu, Jun-Shuai Chen, Jin-Hui Gu, Yunjie Lu, Jia-Sen Xie, Mingwei Gu, et al.

    New bistricyclic aromatic enes with faster conformational transition speeds were designed and synthesized for high-precision interfacial pressure sensing applications.


  • Top Cited Papers
    Open Access

    Scalable magnetoreceptive e-skin for energy-efficient high-resolution interaction towards undisturbed extended reality

    by Pavlo Makushko, Jin Ge, Gilbert Santiago Cañón Bermúdez, Oleksii Volkov, Yevhen Zabila, Stanislav Avdoshenko, Rico Illing, Leonid Ionov, Martin Kaltenbrunner, Jürgen Fassbender, et al.

    Electronic skins (e-skins) seek to go beyond the natural human perception, e.g., by creating magnetoperception to sense and interact with omnipresent magnetic fields. However, realizing magnetoreceptive e-skin with spatially continuous sensing over large areas is challenging due to increase in power consumption with increasing sensing resolution. Here, by incorporating the giant magnetoresistance effect and electrical resistance tomography, we achieve continuous sensing of magnetic fields across an area of 120 × 120 mm2 with a sensing resolution of better than 1 mm. Our approach enables magnetoreceptors with three orders of magnitude less energy consumption compared to state-of-the-art transistor-based magnetosensitive matrices. A simplified circuit configuration results in optical transparency, mechanical compliance, and vapor/liquid permeability, consequently permitting its imperceptible integration onto skins. Ultimately, these achievements pave the way for exceptional applications, including magnetoreceptive e-skin capable of undisturbed recognition of fine-grained gesture and a magnetoreceptive contact lens permitting touchless interaction.


  • High Ion-Conductive Hydrogel: Soft, Elastic, with Wide Humidity Tolerance and Long-Term Stability

    by Yan-Na Lu, Kai Mo, Xue-Hang Liang, Jia-Sen Xie, Ying Yang, Lin Zheng, Mingwei Gu, Xiang-Ru Liu, Yunjie Lu, Jin Ge

    Ion-conductive hydrogels have received great attention due to their significant potential in flexible electronics. However, achieving hydrogels that simultaneously possess high ionic conductivity and stability under varying humidity conditions remains a challenge, limiting their practical applications. Herein, we propose a thermally controlled chemical cross-linking strategy to prepare an elastic and conductive hydrogel (ECH) of poly(vinyl alcohol) (PVA) with high content of H2SO4. The covalent cross-links formed effectively tackle the instability issue in high humidity of physically cross-linked PVA/H2SO4 hydrogels with high ionic conductivity, which were previously developed via the polymer-in-salt strategy. We systematically investigated the reaction conditions and clarified the methods to optimize the hydroxyl dehydration of PVA, resulting in excellent mechanical properties and ion conductivity simultaneously. The ECH demonstrates impressive ionic conductivity (up to 392 ± 49 mS cm-1) and elasticity (over 80% resilience upon stretching and compression after being equilibrated at various humidity levels for 24 days). Thanks to the excellent water retention of the high H2SO4 content, the ECH maintains an ionic conductivity exceeding 210 mS cm-1 for over 420 days at 50% relative humidity (RH) and retains over 100 mS cm-1 even after 3 days under extremely dry conditions (7% RH). These remarkable properties make the ECH an ideal candidate for applications requiring reliable ionic conductivity in diverse environmental conditions. Additionally, we demonstrated that the ECH can function as a stretchable Joule heater with high conformability for heating up objects with curved surfaces. The heating rate could reach a fast rate of ∼12 °C s-1 even when a human-safe alternating current voltage is below 36 V, attributed to the high ionic conductivity. We believe that the high performance and ease of fabrication make our hydrogels a promising candidate for use as electrolytes in flexible energy storage devices, electrolyte gates in electrochemical transistors, and artificial skin, which often face long-term stability challenges under varying humidity conditions.


  • Outpatient mean arterial pressure: A potentially modifiable risk for acute kidney injury and death among patients with cirrhosis

    by Giuseppe Cullaro, Sy Han Chiou, Cynthia Fenton, Jin Ge, Charles E. McCulloch, Jessica Rubin, Amy M. Shui, Frederick Yao, Jennifer C. Lai

    Mean arterial blood pressure (MAP), which decreases as portal hypertension progresses, may be a modifiable risk factor among patients with cirrhosis. We included adults enrolled in the Functional Assessment in Liver Transplantation study. We completed latent class trajectory analyses to define MAP trajectories. We completed time-dependent Cox-regression analyses to test the association between outpatient MAP and 3 cirrhosis-related outcomes: (1) stage 2 acute kidney injury (AKI), defined as a ≥200% increase in serum creatinine from baseline; (2) a 5-point increase in the MELD-Na score, defined as the incidence of increase from initial MELD-Na; (3) waitlist mortality, defined as death on the waitlist. For each outcome, we defined MAP cut points by determining the maximally selected Log-rank statistic after univariable Cox-regression analyses. Among the 1786 patients included in this analysis, our latent class trajectory analyses identified 3 specific outpatient MAP trajectories: “stable-low,” “stable-high,” and “increasing-to-decreasing.” However, >80% of patients were in a “stable-low” trajectory. We found in adjusted analyses that outpatient MAP was associated with each of our outcomes: Stage 2 AKI (adjusted hazard ratio 0.88 per 10 mm Hg increase in MAP [95% CI: 0.79–0.99]); 5-point increase in MELD-Na (adjusted hazard ratio: 0.91 [95% CI: 0.86–0.96]; waitlist mortality (adjusted hazard ratio: 0.89 [95% CI: 0.81–0.96]). For each outcome, we found that an outpatient MAP of 82 mm Hg was most associated with outcomes (p<0.05 for all). Our study informs the association between outpatient MAP and cirrhosis-related outcomes. These findings, coupled with the identification of specific thresholds, lay the foundation for the trial of targeted outpatient MAP modulation in patients with cirrhosis.