Ivan Micic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ivan Micic has a total of 161 co-authors. Here are the top co-authors by number of shared publications:
- Sasa Milenkovic
Niš University Clinical Centre, Academician Prof. Dr. Milorad Mitković Clinic for Orthopaedics and Traumatology, Niš, Serbia + University of Niš, Faculty of Medicine, Niš, Serbia
22 shared publications Predrag Stojiljkovic
Clinical Center Niš, Clinic for Orthopedics and Traumatology, Niš, Serbia + University of Niš, Faculty of Medicine, Niš, Serbia
17 shared publicationsMilorad Mitkovic
University of Niš, Faculty of Medicine, Niš, Serbia
16 shared publicationsDesimir Mladenovic
Clinical Centar Niš, Clinic for Orthopaedic and Traumatology, Niš
14 shared publicationsMilorad B. Mitković
University of Nis, Medical Faculty, Nis, Serbia
8 shared publicationsD. Mladenovic
Medical faculty, Clinical Center, Orthopaedic and Traumatology Clinic, University of Nis, Nis, Serbia
6 shared publications
Latest Publications
- Open Access
- 1 January 2022
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 79 (2) , 177-182
Comparative analysis of operation time and intraoperative fluoroscopy time in intramedullary and extramedullary fixation of trochanteric fractures
Background/Aim. Cephalomedullary and extramedullary methods are used for the internal fixation of trochanteric fractures. The usage of the third generation Gamma Nail (GN) is a gold standard in this kind of treatments. Self-dynamisable Internal Fixator (SIF) is an extramedullary implant for trochanteric fractures? treatment. The aim of this study was to compare these two methods regarding operation time and intraoperative fluoroscopy time. Methods. A total of 89 patients with a surgical treatment of a trochanteric fracture were included in this study. There were two groups of patients ? GN group (43 patients) and SIF group (46 patients). Results. Average operation times were 67.5 min (GN group) and 56.0 min (SIF group). Average intraoperative fluoroscopy times were 84.8 s (GN group) and 36.7 s (SIF group). The difference between the groups was statistically significant for both of the given parameters (p < 0.05). The correlation between operation time and intraoperative fluoroscopy time was confirmed in the SIF group (p < 0.05; r = 0.405), while it was not confirmed in the GN group (p > 0.05). There was a higher variability in the GN method than in the SIF method regarding the duration and type of repeated surgical maneuvers followed by X-ray checks. Conclusion. The number of planned surgical interventions per day could depend on the type of trochanteric fracture internal fixation (intramedullary or extramedullary). Certain additional analyses including radiation dose assessment are desirable to clarify if shorter intraoperative fluoroscopy time in the SIF method can have the influence regarding intraoperative X-ray protection clothing. If there is the need to activate dynamization in long femoral axis after initial static fixation in that axis, the SIF method provides its spontaneous activation several weeks after the surgery without the need neither for additional surgery nor for additional intraoperative fluoroscopy
- 1 January 2022
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 79 (2) , 177-182
Open AccessComparative analysis of operation time and intraoperative fluoroscopy time in intramedullary and extramedullary fixation of trochanteric fractures
Background/Aim. Cephalomedullary and extramedullary methods are used for the internal fixation of trochanteric fractures. The usage of the third generation Gamma Nail (GN) is a gold standard in this kind of treatments. Self-dynamisable Internal Fixator (SIF) is an extramedullary implant for trochanteric fractures? treatment. The aim of this study was to compare these two methods regarding operation time and intraoperative fluoroscopy time. Methods. A total of 89 patients with a surgical treatment of a trochanteric fracture were included in this study. There were two groups of patients ? GN group (43 patients) and SIF group (46 patients). Results. Average operation times were 67.5 min (GN group) and 56.0 min (SIF group). Average intraoperative fluoroscopy times were 84.8 s (GN group) and 36.7 s (SIF group). The difference between the groups was statistically significant for both of the given parameters (p < 0.05). The correlation between operation time and intraoperative fluoroscopy time was confirmed in the SIF group (p < 0.05; r = 0.405), while it was not confirmed in the GN group (p > 0.05). There was a higher variability in the GN method than in the SIF method regarding the duration and type of repeated surgical maneuvers followed by X-ray checks. Conclusion. The number of planned surgical interventions per day could depend on the type of trochanteric fracture internal fixation (intramedullary or extramedullary). Certain additional analyses including radiation dose assessment are desirable to clarify if shorter intraoperative fluoroscopy time in the SIF method can have the influence regarding intraoperative X-ray protection clothing. If there is the need to activate dynamization in long femoral axis after initial static fixation in that axis, the SIF method provides its spontaneous activation several weeks after the surgery without the need neither for additional surgery nor for additional intraoperative fluoroscopy
- Open Access
- 1 January 2021
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 78 (10) , 1053-1059
Application of two types of suspensory fixation in reconstruction of anterior cruciate ligament with a semitendinosus-gracilis graft: A randomized prospective study
Background/Aim. Injury to the anterior cruciate ligament (ACL) of the knee is the most common ligament injury that requires operative treatment. So far, multiple ACL reconstruction (ACLR) techniques using a variety of graft types and implants that fixate the grafts have been described. The aim of the study was to compare two different ACLR techniques using two implant types for suspensory graft fixation in the femoral tunnel. Methods. This randomized-prospective study encompassed 60 patients/subjects who underwent ACLR in the period between January 2015 and December 2017 at the Department of Orthopaedics and Traumatology of Military Hospital ?Dr Vladan Djordjevic? Nis. The ACLR in all patients included in the study was per-formed using a quadruple semitendinosus-gracilis (STG) graft with two types of suspensory fixation on the lateral femoral cortex, whereas the graft fixation in the tibial tunnel was performed using an osteoconductive bioresorbable screw. The post-operative knee stability was assessed 24 months after surgery using the Lachman test and the lateral pivot shift test, as well as the KT-1000 arthrometer test. Results. In patients whose graft was fixated using a fixed-length loop implant, the mean post-surgery knee stability, measured with the KT-1000, was 1.167 ? 0.780; in patients whose graft was fixated using an adjustable-length loop implant, the mean value of the KT-1000 was 1.100 ? 0.894 (p = 0.605). The mean post-surgery International Knee Documentation Committee (IKDC) score for the fixed-length loop group was 84.887 ? 9.0207, while for the adjustable-length loop the score was 88.327 ? 7.302. The mean Lysholm score was 93.50 ? 6.872 for the fixed-length loop group of patients and 94.00 ? 5.527 for the adjustable-length loop group of patients. Conclusion. Both types of implants can be used with success during ACLR, because the functional results of operative treatment using both implants were identical after surgery.
- 1 January 2021
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 78 (10) , 1053-1059
Open AccessApplication of two types of suspensory fixation in reconstruction of anterior cruciate ligament with a semitendinosus-gracilis graft: A randomized prospective study
Background/Aim. Injury to the anterior cruciate ligament (ACL) of the knee is the most common ligament injury that requires operative treatment. So far, multiple ACL reconstruction (ACLR) techniques using a variety of graft types and implants that fixate the grafts have been described. The aim of the study was to compare two different ACLR techniques using two implant types for suspensory graft fixation in the femoral tunnel. Methods. This randomized-prospective study encompassed 60 patients/subjects who underwent ACLR in the period between January 2015 and December 2017 at the Department of Orthopaedics and Traumatology of Military Hospital ?Dr Vladan Djordjevic? Nis. The ACLR in all patients included in the study was per-formed using a quadruple semitendinosus-gracilis (STG) graft with two types of suspensory fixation on the lateral femoral cortex, whereas the graft fixation in the tibial tunnel was performed using an osteoconductive bioresorbable screw. The post-operative knee stability was assessed 24 months after surgery using the Lachman test and the lateral pivot shift test, as well as the KT-1000 arthrometer test. Results. In patients whose graft was fixated using a fixed-length loop implant, the mean post-surgery knee stability, measured with the KT-1000, was 1.167 ? 0.780; in patients whose graft was fixated using an adjustable-length loop implant, the mean value of the KT-1000 was 1.100 ? 0.894 (p = 0.605). The mean post-surgery International Knee Documentation Committee (IKDC) score for the fixed-length loop group was 84.887 ? 9.0207, while for the adjustable-length loop the score was 88.327 ? 7.302. The mean Lysholm score was 93.50 ? 6.872 for the fixed-length loop group of patients and 94.00 ? 5.527 for the adjustable-length loop group of patients. Conclusion. Both types of implants can be used with success during ACLR, because the functional results of operative treatment using both implants were identical after surgery.
- Open Access
- 1 January 2020
- Published by National Library of Serbia in Srpski arhiv za celokupno lekarstvo
- Vol. 148 (7-8) , 451-454
Hip function and health-related quality of life in intramedullary and extramedullary internal fixation of trochanteric fractures
Introduction/Objective. There are extramedullary and intramedullary methods of trochanteric fractures? internal fixation with implants having a lag screw. The objective of this study was to examine the difference in impact of these fixation types on final hip function and health-related quality of life. Method. There were 75 patients treated for a trochanteric fracture, using self-dynamisable internal fixator (SIF group), as an extramedullary method, or gamma nail (GN group), as an intramedullary method. These patients were called for the evaluation of Harris Hip Score (HHS) and SF-12 questionnaire at least two years after surgery. The SF-12 questionnaire has dual expression ? physical component score (PCS) and mental component score (MCS). Results. There were no significant differences between the SIF group and the GN group regarding HHS, PCS, and MCS. Positive correlation was confirmed between HHS, PCS, and MCS, with the strongest relation between HHS and PCS. Negative correlation was confirmed between age and HHS. Conclusion. There was no difference in final hip function and health-related quality of life between SIF and GN methods in trochanteric fractures treatment (p > 0.05). These parameters of outcome were confirmed to have positive interrelation (p < 0.05). Both submuscular presence of extramedullary implant with dimensions of SIF and the need for bone reaming in cephalomedullary fixation were considered not to have significant impact in HHS and SF-12 scores after trochanteric fractures treatment by internal fixation.
- 1 January 2020
- Published by National Library of Serbia in Srpski arhiv za celokupno lekarstvo
- Vol. 148 (7-8) , 451-454
Open AccessHip function and health-related quality of life in intramedullary and extramedullary internal fixation of trochanteric fractures
Introduction/Objective. There are extramedullary and intramedullary methods of trochanteric fractures? internal fixation with implants having a lag screw. The objective of this study was to examine the difference in impact of these fixation types on final hip function and health-related quality of life. Method. There were 75 patients treated for a trochanteric fracture, using self-dynamisable internal fixator (SIF group), as an extramedullary method, or gamma nail (GN group), as an intramedullary method. These patients were called for the evaluation of Harris Hip Score (HHS) and SF-12 questionnaire at least two years after surgery. The SF-12 questionnaire has dual expression ? physical component score (PCS) and mental component score (MCS). Results. There were no significant differences between the SIF group and the GN group regarding HHS, PCS, and MCS. Positive correlation was confirmed between HHS, PCS, and MCS, with the strongest relation between HHS and PCS. Negative correlation was confirmed between age and HHS. Conclusion. There was no difference in final hip function and health-related quality of life between SIF and GN methods in trochanteric fractures treatment (p > 0.05). These parameters of outcome were confirmed to have positive interrelation (p < 0.05). Both submuscular presence of extramedullary implant with dimensions of SIF and the need for bone reaming in cephalomedullary fixation were considered not to have significant impact in HHS and SF-12 scores after trochanteric fractures treatment by internal fixation.
- Open Access
- 22 July 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-5
Humeral Diaphyseal Fracture Nonunion: An Audit of the Outcome from Intramedullary Nailing and DCP Plating
Purpose. This study aims to compare the functional outcomes of nonunion humeral diaphyseal fractures following conservative treatment when managed surgically with either a plate or intramedullary (IM) nail fixation. Methods. This was a retrospective study of 56 patients with nonunion humeral fractures following conservative treatment who underwent plate or IM nail fixation between 2007 and 2014. Comparison was made for short term profile (intraoperative blood loss, duration of surgery, and length of hospitalization) and long term clinical outcome with functional score (Constant-Murley score (CMS)) and Disabilities of the Arm, Shoulder and Hand (DASH) score). The union and complication rate were also compared. Results. There were 36 and 20 patients included in plate and IM nail fixation group with the average of 36.14 ± 7.54-month follow-up time. The intraoperative blood loss, duration of surgery, and length of hospitalization were superior in IM nail group compared to plate group (p < 0.001, p < 0.001, and p < 0.001, respectively). The mean CMS and DASH score were superior in the plate group compared to the IM nail group (82.40 ± 16.84 versus 77.58 ± 12.96; 17.46 ± 11.05 versus 20.86 ± 11.63, respectively; with p = 0.246, p = 0.299, respectively). Plate fixation group showed higher union rate and complication rate compared to IM nail group (100% versus 90%, 13.8% versus 10%, respectively). Conclusions. IM nail and plate fixation demonstrated comparable clinical outcome. IM nail fixation showed superior short term result with lower complication rate which benefits the elderly group patients with significant comorbidities.
- 22 July 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-5
Open AccessHumeral Diaphyseal Fracture Nonunion: An Audit of the Outcome from Intramedullary Nailing and DCP Plating
Purpose. This study aims to compare the functional outcomes of nonunion humeral diaphyseal fractures following conservative treatment when managed surgically with either a plate or intramedullary (IM) nail fixation. Methods. This was a retrospective study of 56 patients with nonunion humeral fractures following conservative treatment who underwent plate or IM nail fixation between 2007 and 2014. Comparison was made for short term profile (intraoperative blood loss, duration of surgery, and length of hospitalization) and long term clinical outcome with functional score (Constant-Murley score (CMS)) and Disabilities of the Arm, Shoulder and Hand (DASH) score). The union and complication rate were also compared. Results. There were 36 and 20 patients included in plate and IM nail fixation group with the average of 36.14 ± 7.54-month follow-up time. The intraoperative blood loss, duration of surgery, and length of hospitalization were superior in IM nail group compared to plate group (p < 0.001, p < 0.001, and p < 0.001, respectively). The mean CMS and DASH score were superior in the plate group compared to the IM nail group (82.40 ± 16.84 versus 77.58 ± 12.96; 17.46 ± 11.05 versus 20.86 ± 11.63, respectively; with p = 0.246, p = 0.299, respectively). Plate fixation group showed higher union rate and complication rate compared to IM nail group (100% versus 90%, 13.8% versus 10%, respectively). Conclusions. IM nail and plate fixation demonstrated comparable clinical outcome. IM nail fixation showed superior short term result with lower complication rate which benefits the elderly group patients with significant comorbidities.
- Open Access
- 6 January 2019
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 53 (6) , 414-419
Osteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
Objectives The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. Methods From July 2012 to July 2014, 50 patients [28 men and 22 women; mean age, 56.4 (range: 45–56) years] underwent arthroscopic rotator cuff repair for a medium-to large-size tear with double-row suture-bridge technique. The bioabsorbable anchors used in the medial row comprised hydroxyapatite-polylactic acid enantiomer, and the nonabsorbable anchors in the lateral row were polyetheretherketone (PEEK)-type anchors. All patients underwent MRI evaluation at 3, 6, and 12 months postoperatively to determine osteolysis and identify any retear. Results The incidences of osteolysis at 3, 6, and 12 months postoperatively were 1%, 4%, and 6% with nonabsorbable anchors and 13%, 29%, and 39% with bioabsorbable anchors, respectively. The incidences of osteolysis were significantly higher with the bioabsorbable anchors than with the nonabsorbable anchors (P < 0.005 for all three follow-ups). There was no significant difference between osteolysis and non-osteolysis groups regarding the retear rate or retear size (P = 0.189 and 0.069, respectively). Conclusions Osteolysis was common around bioabsorbable anchors used for arthroscopic rotator cuff repair, and it also occurred around the PEEK-type nonabsorbable anchors. The incidence of osteolysis of nonabsorbable anchors was significantly lower than that of bioabsorbable anchors. Osteolysis did not significantly affect rotator cuff retear after arthroscopic repair with either bioabsorbable or nonabsorbable anchors. Level of evidence Level III, Therapeutic Study.
- 6 January 2019
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 53 (6) , 414-419
Open AccessOsteolysis is observed around both bioabsorbable and nonabsorbable anchors on serial magnetic resonance images of patients undergoing arthroscopic rotator cuff repair
Objectives The objective of this study was to evaluate the incidence of osteolysis around the bioabsorbable and nonabsorbable anchors using serial magnetic resonance imaging (MRI) and to determine the relationship between osteolysis and the retear rate after arthroscopic rotator cuff repair. Methods From July 2012 to July 2014, 50 patients [28 men and 22 women; mean age, 56.4 (range: 45–56) years] underwent arthroscopic rotator cuff repair for a medium-to large-size tear with double-row suture-bridge technique. The bioabsorbable anchors used in the medial row comprised hydroxyapatite-polylactic acid enantiomer, and the nonabsorbable anchors in the lateral row were polyetheretherketone (PEEK)-type anchors. All patients underwent MRI evaluation at 3, 6, and 12 months postoperatively to determine osteolysis and identify any retear. Results The incidences of osteolysis at 3, 6, and 12 months postoperatively were 1%, 4%, and 6% with nonabsorbable anchors and 13%, 29%, and 39% with bioabsorbable anchors, respectively. The incidences of osteolysis were significantly higher with the bioabsorbable anchors than with the nonabsorbable anchors (P < 0.005 for all three follow-ups). There was no significant difference between osteolysis and non-osteolysis groups regarding the retear rate or retear size (P = 0.189 and 0.069, respectively). Conclusions Osteolysis was common around bioabsorbable anchors used for arthroscopic rotator cuff repair, and it also occurred around the PEEK-type nonabsorbable anchors. The incidence of osteolysis of nonabsorbable anchors was significantly lower than that of bioabsorbable anchors. Osteolysis did not significantly affect rotator cuff retear after arthroscopic repair with either bioabsorbable or nonabsorbable anchors. Level of evidence Level III, Therapeutic Study.
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 76 (2) , 210-215
Femoroacetabular impingement after the femoral neck fracture healed in a nonanatomical position
Introduction. Femoroacetabular impingement is the result of the pathological conditions in the osseous acetabulum and/or the proximal femur. One of its causes is a non-anatomically healed femoral neck fracture. Case report. A male, aged 51, with a subcapital left femoral neck fracture was treated conservatively. The fracture healed 9 months later and although the patient was walking on crutches he suffered from pain in the left groin. The X-ray images showed the valgus and the retroposition of the left femoral head. The patient was operated on and intraoperatively the thickness and a bone prominence in the anterosuperior femoral neck area in the line of the previous fracture were found, which was pressing and spreading beneath the acetabular labrum, thus squeezing the acetabular cartilage. The labrum lesion which was found was the result of the mechanical pressure of the existing femoral neck deformity during the hip movements. Irretrievably damaged part of the labrum was resected and the anterosuperior femoral headneck osteochondroplasty was done. One year after the surgery, the patient had no pain, he walked without limping, the impingement test was negative, the radiological parameters were adjusted and there were no signs of the avascular necrosis of the femoral head. Conclusion. The femoral neck fracture should be treated adequately with the full anatomical position and the proper internal fixation. If the deformity occurs as the result of a treatment, it should be removed as soon as possible to prevent the osteoarthritis of the hip.
- 1 January 2019
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 76 (2) , 210-215
Open AccessFemoroacetabular impingement after the femoral neck fracture healed in a nonanatomical position
Introduction. Femoroacetabular impingement is the result of the pathological conditions in the osseous acetabulum and/or the proximal femur. One of its causes is a non-anatomically healed femoral neck fracture. Case report. A male, aged 51, with a subcapital left femoral neck fracture was treated conservatively. The fracture healed 9 months later and although the patient was walking on crutches he suffered from pain in the left groin. The X-ray images showed the valgus and the retroposition of the left femoral head. The patient was operated on and intraoperatively the thickness and a bone prominence in the anterosuperior femoral neck area in the line of the previous fracture were found, which was pressing and spreading beneath the acetabular labrum, thus squeezing the acetabular cartilage. The labrum lesion which was found was the result of the mechanical pressure of the existing femoral neck deformity during the hip movements. Irretrievably damaged part of the labrum was resected and the anterosuperior femoral headneck osteochondroplasty was done. One year after the surgery, the patient had no pain, he walked without limping, the impingement test was negative, the radiological parameters were adjusted and there were no signs of the avascular necrosis of the femoral head. Conclusion. The femoral neck fracture should be treated adequately with the full anatomical position and the proper internal fixation. If the deformity occurs as the result of a treatment, it should be removed as soon as possible to prevent the osteoarthritis of the hip.
- Open Access
- 1 January 2019
- Published by Wiley in Advances in Orthopedics
- Vol. 2019, 1-6
The Role of Additional K-Wires on AO Type C Distal Radius Fracture Treatment with External Fixator in Young Population
Objectives. Several methods have been proposed to treat AO type C distal radius fracture. External fixator has gained popularity for its simple procedure and rapid recovery. Some surgeons suggested that additional K-wires may play a critical role in the outcome. The purpose of study is to evaluate the role of additional K wires in treating distal radial fracture with external fixator regarding its outcome. Material and Methods. From January 2006 to January 2010, 40 patients with AO type C distal radius fracture were treated with external fixator, with (EF) or without additional K wires (EFK). Radiologic outcome parameters include radial inclination, volar tilt, radial length, and the presence of radiocarpal arthritis according to Knirk and Jupiter. Clinical outcomes include New York Orthopedic Hospital (NYOH) wrist scoring scale. Results. Radiographic outcome showed significant difference in regard of articular congruency at the final follow-up with the EFK group showing the advantage in maintaining the articular incongruity. NYOH wrist scoring scale showed no significant difference between both groups at final follow-up. The amount of articular step-off was less in EFK group with significant statistical finding on the final follow up. Conclusion. Both EF and EFK technique were able to provide satisfactory result in treating AO type C distal radius fractures. We observed that EFK is superior in reducing the number of radiocarpal arthritic changes compared to EF group due to its superiority in reducing articular step-off.
- 1 January 2019
- Published by Wiley in Advances in Orthopedics
- Vol. 2019, 1-6
Open AccessThe Role of Additional K-Wires on AO Type C Distal Radius Fracture Treatment with External Fixator in Young Population
Objectives. Several methods have been proposed to treat AO type C distal radius fracture. External fixator has gained popularity for its simple procedure and rapid recovery. Some surgeons suggested that additional K-wires may play a critical role in the outcome. The purpose of study is to evaluate the role of additional K wires in treating distal radial fracture with external fixator regarding its outcome. Material and Methods. From January 2006 to January 2010, 40 patients with AO type C distal radius fracture were treated with external fixator, with (EF) or without additional K wires (EFK). Radiologic outcome parameters include radial inclination, volar tilt, radial length, and the presence of radiocarpal arthritis according to Knirk and Jupiter. Clinical outcomes include New York Orthopedic Hospital (NYOH) wrist scoring scale. Results. Radiographic outcome showed significant difference in regard of articular congruency at the final follow-up with the EFK group showing the advantage in maintaining the articular incongruity. NYOH wrist scoring scale showed no significant difference between both groups at final follow-up. The amount of articular step-off was less in EFK group with significant statistical finding on the final follow up. Conclusion. Both EF and EFK technique were able to provide satisfactory result in treating AO type C distal radius fractures. We observed that EFK is superior in reducing the number of radiocarpal arthritic changes compared to EF group due to its superiority in reducing articular step-off.
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Srpski arhiv za celokupno lekarstvo
- Vol. 146 (9-10) , 543-548
Operation time and intraoperative fluoroscopy time in different internal fixation methods for subtrochanteric fractures treatment
Introduction/Objective. Subtrochanteric fractures are unstable, tending to a varus, antecurvatum, and shortening deformity. The aim of this paper was to compare operation time and fluoroscopy time between different internal fixation methods in the treatment of subtrochanteric fractures. Method. The prospective study of the group of 27 patients with a subtrochanteric fracture treated by the SIF (selfdynamisable internal fixator with a trochanteric unit) method had been done. Operation time and fluoroscopy time values from this group were compared to the same parameters data from the literature for intramedullary (IM) nails, proximal femur locking plates (PF-LCP), dynamic condylar screws (DCS), and the 95?-angled blade plate. Results. In the SIF group, operation time was 62.2 (25?140) minutes and fluoroscopy time was 43 (20?95) s. Average operation time from the literature data was: 102.1 (43?181) minutes for IM nail, 94.2 (75?129) minutes for PF-LCP, 105.3 (70?166) minutes for DCS and 221.5 (171?272) minutes for blade plate. Average fluoroscopy time from the literature data was: 109.6 (34?250) seconds for IM nail, 102.3 (47?180) seconds for PF-LCP, 238 seconds for DCS. Operation time and intraoperative fluoroscopy time were higher in IM nail, PF-LCP, DCS and blade plate comparing to SIF method (p < 0.05). Conclusion. The above mentioned difference could be explained by a degree of required accuracy in the initial operative technique maneuvers, by used number of screws and by the type of the fracture reduction performance in different fixation methods. Operation time during IM nailing of subtrochanteric fractures sometimes can be shorter than average operation time in SIF method, what could be explained by the skill of the surgeon to perform as fast closed reduction for insertion of guide wire.
- 1 January 2018
- Published by National Library of Serbia in Srpski arhiv za celokupno lekarstvo
- Vol. 146 (9-10) , 543-548
Open AccessOperation time and intraoperative fluoroscopy time in different internal fixation methods for subtrochanteric fractures treatment
Introduction/Objective. Subtrochanteric fractures are unstable, tending to a varus, antecurvatum, and shortening deformity. The aim of this paper was to compare operation time and fluoroscopy time between different internal fixation methods in the treatment of subtrochanteric fractures. Method. The prospective study of the group of 27 patients with a subtrochanteric fracture treated by the SIF (selfdynamisable internal fixator with a trochanteric unit) method had been done. Operation time and fluoroscopy time values from this group were compared to the same parameters data from the literature for intramedullary (IM) nails, proximal femur locking plates (PF-LCP), dynamic condylar screws (DCS), and the 95?-angled blade plate. Results. In the SIF group, operation time was 62.2 (25?140) minutes and fluoroscopy time was 43 (20?95) s. Average operation time from the literature data was: 102.1 (43?181) minutes for IM nail, 94.2 (75?129) minutes for PF-LCP, 105.3 (70?166) minutes for DCS and 221.5 (171?272) minutes for blade plate. Average fluoroscopy time from the literature data was: 109.6 (34?250) seconds for IM nail, 102.3 (47?180) seconds for PF-LCP, 238 seconds for DCS. Operation time and intraoperative fluoroscopy time were higher in IM nail, PF-LCP, DCS and blade plate comparing to SIF method (p < 0.05). Conclusion. The above mentioned difference could be explained by a degree of required accuracy in the initial operative technique maneuvers, by used number of screws and by the type of the fracture reduction performance in different fixation methods. Operation time during IM nailing of subtrochanteric fractures sometimes can be shorter than average operation time in SIF method, what could be explained by the skill of the surgeon to perform as fast closed reduction for insertion of guide wire.
- Open Access
- 1 January 2017
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 74 (3) , 261-266
Ipsilateral humeral neck and shaft fractures
Background/Aim. Fractures of the proximal humerus or shaft are common, however, ipsilateral neck and shaft humerus fracture is a rare phenomenon. This combination injury is challenging for orthopaedic surgeons because of its complex treatment options at present. The purpose of this study was to review a series of ipsilateral humeral neck and shaft fractures to study the fracture pattern, complications and treatment outcomes of each treatment options used. Methods. A total of six patients (four female and two male) with the average age of 42.8 years (range: 36–49 years) was collected and reviewed retrospectively. Two of them were treated with double plates and four with antegrade intramedullary nail. According to the Neer’s classification, all proximal fractures were two-part surgical neck fractures. All humeral shaft fractures were located at the middle of one third. Five fractures were simple transverse (A3), one fragmented wedge fracture (B3). One patient had associated radial nerve palsy. Results. All surgical neck fractures except one united uneventfully in the average time span of 8.7 weeks. Four humeral shaft fractures healed in near anatomic alignment. The remaining two patients had the nonunion with no radiological signs of fracture healing. The average University of California, Los Angeles End-Results (UCLA) score was 23.1. On the contrary, the average American Shoulder and Elbow Surgeon's (ASES) score was 73.3. The patients treated with antegrade intramedullary nails presented 70.5 points. The ASES scores were 79 in the double plates group. Conclusions. Ipsilateral humeral shaft and neck fracture is extremely rare. Both antegrade intramedullar nailing and double plates result in healing of fractures. However the risk of complication is lower in the double plating group.
- 1 January 2017
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 74 (3) , 261-266
Open AccessIpsilateral humeral neck and shaft fractures
Background/Aim. Fractures of the proximal humerus or shaft are common, however, ipsilateral neck and shaft humerus fracture is a rare phenomenon. This combination injury is challenging for orthopaedic surgeons because of its complex treatment options at present. The purpose of this study was to review a series of ipsilateral humeral neck and shaft fractures to study the fracture pattern, complications and treatment outcomes of each treatment options used. Methods. A total of six patients (four female and two male) with the average age of 42.8 years (range: 36–49 years) was collected and reviewed retrospectively. Two of them were treated with double plates and four with antegrade intramedullary nail. According to the Neer’s classification, all proximal fractures were two-part surgical neck fractures. All humeral shaft fractures were located at the middle of one third. Five fractures were simple transverse (A3), one fragmented wedge fracture (B3). One patient had associated radial nerve palsy. Results. All surgical neck fractures except one united uneventfully in the average time span of 8.7 weeks. Four humeral shaft fractures healed in near anatomic alignment. The remaining two patients had the nonunion with no radiological signs of fracture healing. The average University of California, Los Angeles End-Results (UCLA) score was 23.1. On the contrary, the average American Shoulder and Elbow Surgeon's (ASES) score was 73.3. The patients treated with antegrade intramedullary nails presented 70.5 points. The ASES scores were 79 in the double plates group. Conclusions. Ipsilateral humeral shaft and neck fracture is extremely rare. Both antegrade intramedullar nailing and double plates result in healing of fractures. However the risk of complication is lower in the double plating group.
- Open Access
- 1 January 2017
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 74 (1) , 51-53
First experiences with the Fitmore® hip stem: Early results of the 16-month monitoring
Introduction. Fitmore hip stem belongs to the group of short stem prostheses with the metaphysar stabilization, with its shape and form it protects the bone mass in the greater trochanter region and distal part of the femur. The aim of this paper is to present the early postoperative results in patients with implanted Fitmore hip stem and point out some of the advantages. Material and methods. A series of 10 patients is presented with implanted Fitmore hip stem. The average age of the patients is 54,5 (48-65) years. There are 5 women and 5 men. The total monitoring time is 16 months. To rate the condition of the hip joint we have used WOMAC score. We have also monitored the degree of hip pain, hip flexion, heterotopic ossification and indentation in the stem of the prosthesis. Results. After 12 months of monitoring 9 (90%) patients had no pain in the thigh region, and only 1 (10%) experienced mild pain. The hip flexion rose from the average 89 degrees to postoperative 114 degrees. WOMAC score rose as well, from 49 to 94 average points. Indentation in the stem was registered 3 months after the operation in 2 (20%) patients - in one of the patients the indentation was 3 mm and in the other patient it was 5 mm. After the 16-month monitoring, the results are excellent. The monitoring period is short though, it should be continued and the results should be presented after 5 and then after 10 years. Conclusion. Early results of the implantation Fitmore stem show good bone ingrowth with excellent functional result.
- 1 January 2017
- Published by National Library of Serbia in Vojnosanitetski Pregled
- Vol. 74 (1) , 51-53
Open AccessFirst experiences with the Fitmore® hip stem: Early results of the 16-month monitoring
Introduction. Fitmore hip stem belongs to the group of short stem prostheses with the metaphysar stabilization, with its shape and form it protects the bone mass in the greater trochanter region and distal part of the femur. The aim of this paper is to present the early postoperative results in patients with implanted Fitmore hip stem and point out some of the advantages. Material and methods. A series of 10 patients is presented with implanted Fitmore hip stem. The average age of the patients is 54,5 (48-65) years. There are 5 women and 5 men. The total monitoring time is 16 months. To rate the condition of the hip joint we have used WOMAC score. We have also monitored the degree of hip pain, hip flexion, heterotopic ossification and indentation in the stem of the prosthesis. Results. After 12 months of monitoring 9 (90%) patients had no pain in the thigh region, and only 1 (10%) experienced mild pain. The hip flexion rose from the average 89 degrees to postoperative 114 degrees. WOMAC score rose as well, from 49 to 94 average points. Indentation in the stem was registered 3 months after the operation in 2 (20%) patients - in one of the patients the indentation was 3 mm and in the other patient it was 5 mm. After the 16-month monitoring, the results are excellent. The monitoring period is short though, it should be continued and the results should be presented after 5 and then after 10 years. Conclusion. Early results of the implantation Fitmore stem show good bone ingrowth with excellent functional result.