Jianjie Xu
Research Subjects
Jianjie Xu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bin Du
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
2 shared publications - Xihui Mu
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
2 shared publications - Zhaoyang Tong
State Key Laboratory of Chemistry for NBC Hazards Protection, BeiJing, 102205, China
2 shared publications - Bing Liu
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Jiang Wang
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication - Shuai Liu
State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
1 shared publication
Latest Publications
- Open Access
Fe3O4@PDA@PEI Core-Shell Microspheres as a Novel Magnetic Sorbent for the Rapid and Broad-Spectrum Separation of Bacteria in Liquid Phase
Bacterial infection is a significant cause of morbidity and mortality to humans worldwide. Thus, a method for nonspecific, sensitive, and rapid enrichment of such bacteria is essential for bacteria detection and treatment. This study demonstrates a self-made core-shell Fe3O4@Polydopamine@Polyethyleneimine magnetic beads (Fe3O4@PDA@PEI MBs) with a high density positive charge-based magnetic separation scheme for the broad-spectrum rapid enrichment of microorganisms in the liquid phase. MBs with a high-density positive charge have a strong electrostatic attraction to most microorganisms in nature. Our scheme is as follows: (1) wrapping dopamine (DA) on the iron oxide through self-polymerization and wrapping PEI on the outermost shell layer in a mode of crosslinking with the PDA; (2) subsequently, the Fe3O4@PDA@PEI MBs were used to concentrate microorganisms from the sample solution; (3) performing magnetic separation and calculating the adsorption efficiency. The as-prepared Fe3O4@PDA@PEI MBs composite was carefully characterized by zeta potential analysis, Value stream-mapping (VSM), transmission electron microscopy (TEM), and Fourier transforms infrared spectrometry (FT-IR). In this study, both gram-positive and gram-negative bacteria could be captured in three minutes through electrostatic interaction. Furthermore, the adsorption efficiency on gram-negative (>98%) is higher than that on gram-positive (>95%), allowing for a simple, rapid assay to enrich organisms in resource-limited settings.
Open AccessFe3O4@PDA@PEI Core-Shell Microspheres as a Novel Magnetic Sorbent for the Rapid and Broad-Spectrum Separation of Bacteria in Liquid Phase
Bacterial infection is a significant cause of morbidity and mortality to humans worldwide. Thus, a method for nonspecific, sensitive, and rapid enrichment of such bacteria is essential for bacteria detection and treatment. This study demonstrates a self-made core-shell Fe3O4@Polydopamine@Polyethyleneimine magnetic beads (Fe3O4@PDA@PEI MBs) with a high density positive charge-based magnetic separation scheme for the broad-spectrum rapid enrichment of microorganisms in the liquid phase. MBs with a high-density positive charge have a strong electrostatic attraction to most microorganisms in nature. Our scheme is as follows: (1) wrapping dopamine (DA) on the iron oxide through self-polymerization and wrapping PEI on the outermost shell layer in a mode of crosslinking with the PDA; (2) subsequently, the Fe3O4@PDA@PEI MBs were used to concentrate microorganisms from the sample solution; (3) performing magnetic separation and calculating the adsorption efficiency. The as-prepared Fe3O4@PDA@PEI MBs composite was carefully characterized by zeta potential analysis, Value stream-mapping (VSM), transmission electron microscopy (TEM), and Fourier transforms infrared spectrometry (FT-IR). In this study, both gram-positive and gram-negative bacteria could be captured in three minutes through electrostatic interaction. Furthermore, the adsorption efficiency on gram-negative (>98%) is higher than that on gram-positive (>95%), allowing for a simple, rapid assay to enrich organisms in resource-limited settings.
- Open Access
A Potassium Ion-Exchanged Glass Optical Waveguide Sensor Locally Coated with a Crystal Violet-SiO2 Gel Film for Real-Time Detection of Organophosphorus Pesticides Simulant
An optical waveguide (OWG) sensor was developed for real-time detection of diethyl chlorophosphate (DCP) vapor, which is a typical simulant for organophosphorus pesticides and chemical weapon agents. Silica gel, crystal violet (CV), and potassium ion-exchange (PIE) OWG were used to fabricate the sensor’s device. In the real-time detection of the DCP vapor, the volume fraction of DCP vapor was recorded to be as low as 1.68 × 10−9. Moreover, the detection mechanism of CV-SiO2 gel film coated the PIE OWG sensor for DCP, which was evaluated by absorption spectra. These results demonstrated that the change of output light intensity of the OWG sensor significantly increased with the augment of the DCP concentration. Repeatability as well as selectivity of the sensors were tested using 0.042 × 10−6 and 26.32 × 10−6 volume fraction of the DCP vapor. No clear interference with the DCP detection was observed in the presence of other common solvents (e.g., acetone, methanol, dichloromethane, dimethylsulfoxide, and tetrahydrofuran), benzene series (e.g., benzene, toluene, chlorobenzene, and aniline), phosphorus-containing reagents (e.g., dimethyl methylphosphonate and trimethyl phosphate), acid, and basic gas (e.g., acetic acid and 25% ammonium hydroxide), which demonstrates that the OWG sensor could provide real-time, fast, and accurate measurement results for the detection of DCP.
Open AccessA Potassium Ion-Exchanged Glass Optical Waveguide Sensor Locally Coated with a Crystal Violet-SiO2 Gel Film for Real-Time Detection of Organophosphorus Pesticides Simulant
An optical waveguide (OWG) sensor was developed for real-time detection of diethyl chlorophosphate (DCP) vapor, which is a typical simulant for organophosphorus pesticides and chemical weapon agents. Silica gel, crystal violet (CV), and potassium ion-exchange (PIE) OWG were used to fabricate the sensor’s device. In the real-time detection of the DCP vapor, the volume fraction of DCP vapor was recorded to be as low as 1.68 × 10−9. Moreover, the detection mechanism of CV-SiO2 gel film coated the PIE OWG sensor for DCP, which was evaluated by absorption spectra. These results demonstrated that the change of output light intensity of the OWG sensor significantly increased with the augment of the DCP concentration. Repeatability as well as selectivity of the sensors were tested using 0.042 × 10−6 and 26.32 × 10−6 volume fraction of the DCP vapor. No clear interference with the DCP detection was observed in the presence of other common solvents (e.g., acetone, methanol, dichloromethane, dimethylsulfoxide, and tetrahydrofuran), benzene series (e.g., benzene, toluene, chlorobenzene, and aniline), phosphorus-containing reagents (e.g., dimethyl methylphosphonate and trimethyl phosphate), acid, and basic gas (e.g., acetic acid and 25% ammonium hydroxide), which demonstrates that the OWG sensor could provide real-time, fast, and accurate measurement results for the detection of DCP.