GDGerald A. Denys

Gerald A. Denys

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gerald A. Denys has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multicenter Evaluation of the BD Phoenix CPO Detect Test for Detection and Classification of Carbapenemase-Producing Organisms in Clinical Isolates

    by Vicki Whitley, Susan Kircher, Tracey Gill, Janet A. Hindler, Susan O’rOurke, Charles Cooper, Anagha Tulpule, Gerald A. Denys

    Limited treatment options contribute to high morbidity/mortality rates with carbapenem-resistant, Gram-negative bacterial infections. New approaches for carbapenemase-producing organism (CPO) detection may help inform clinician decision-making on patient treatment and infection control. BD Phoenix CPO detect (CPO detect) detects and classifies carbapenemases in Enterobacterales , Acinetobacter baumannii , and Pseudomonas aeruginosa during susceptibility testing.


  • Validation of the Bio-Response Solutions Human-28 Low-Temperature Alkaline Hydrolysis System

    by Gerald A. Denys

    High temperature alkaline hydrolysis (AH) is recognized as an alternative method for sterilization and disposition of animal carcasses and human remains. The aim of this study is to validate the low temperature (LT) AH process specific to its use in the Bio-Response Solutions, Inc. Human-28 LT System. A 313-lb pig was process using the manufacturers recommended cycle parameters. Stainless steel sample vials containing spore suspensions of Geobacillus stearothermophilus were implanted into the pig’s deep tissue to validate the efficacy of the process conditions. Spore suspensions of Bacillus thuringiensis was suspended in the vessel headspace to validate sterilization. The spore challenge was greater than the recommended 106 log used to determine sterilization. MALDI-TOF mass spectrometry analysis was used to validate the destruction of prion-sized particles in processed effluent. Complete inactivation of spores and digestion of animal tissue were achieved after processing in the Bio-Response Solutions Human-28 LT Alkaline Hydrolysis System. Complete inactivation of spores was achieved when exposed to heat in the animal carcass and headspace. No peptide fragments larger than 2500 Da were observed in the treatment effluent. The Bio-Response Solutions, Inc. Human-28 LT Alkaline Hydrolysis System was as effective as high-temperature alkaline hydrolysis for use on animal and human tissue. LT AH for tissue and bodies exceeded the sterility assurance level III of the US State and Territorial Association on Alternative Treatment Technologies and sterility requirements for animal biosafety level–3 and –4 facilities. LT AH process validated destruction of prion-sized particles.


  • A dual‐center evaluation of platelet culture vials to detect the presence of microorganisms in platelets

    by Gerald Denys, Anagha Tulpule, Jessica Roth, Patty Warns, Tiffany Collins, Susan Mindel

    BACKGROUND: Microorganism contamination of platelets results in a high risk of transfusion‐related sepsis. Here, the ability of culture vials (BD BACTEC Platelet Aerobic/F and Platelet Anaerobic/F vials, Becton, Dickinson and Company) to detect microorganisms in leukoreduced apheresis platelets (LRAPs) and leukoreduced whole blood platelet concentrates (LRWBPCs) was assessed.METHODS: LRAPs or LRWBPCs were inoculated into Aerobic/F and Anaerobic/F vials and placed in a blood culturing system (BD BACTEC FX System, Becton, Dickinson and Company) for growth/monitoring over 7 days to detect preexisting contamination during false‐positive testing. Subsequently, platelets were seeded with microorganisms at approximately 10 CFU/mL or approximately 1 CFU/mL to simulate contamination. Aerobic/F and Anaerobic/F vials were inoculated with platelets (sets of 12). Microorganism growth was detected in the BACTEC FX instrument over 7 days. Overall, 2925 vials were tested.RESULTS: Of the 1905 vials included in the microorganism detection phase, 63 (3.3%) Aerobic/F and 16 (0.8%) Anaerobic/F vials were both BACTEC FX and subculture negative. From the remaining 1827 vials, two (0.1%) Anaerobic/F vials were false positive; no false positives were observed in Aerobic/F vials, and no false negatives occurred in either vial type. Of the remaining 1825 vials (99.9%), 955 Aerobic/F and 870 Anaerobic/F vials were true positives. The mean‐time‐to‐detection range was 8.5 to 77 hours. All true‐positive Aerobic/F and Anaerobic/F vials showed 100% agreement with subculture for positive identification of seeded microorganisms.CONCLUSION: Aerobic/F and Anaerobic/F vials facilitate contamination detection in LRAPs and LRWBPCs down to approximately 1 CFU/mL. These results support the use of Aerobic/F and Anaerobic/F vials for quality control testing of platelets before transfusion.


  • Open Access

    Mechanism of Microbicidal Action of E-101 Solution, a Myeloperoxidase-Mediated Antimicrobial, and Its Oxidative Products

    by Gerald A. Denys, Neil C. Devoe, Polyxeni Gudis, Meghan May, Robert C. Allen, Jackson T. Stephens

    E-101 solution is a first-in-class myeloperoxidase-mediated antimicrobial developed for topical application. It is composed of porcine myeloperoxidase (pMPO), glucose oxidase (GO), glucose, sodium chloride, and specific amino acids in an aqueous solution. Once activated, the reactive species hydrogen peroxide (H2O2), hypochlorous acid, and singlet oxygen are generated. We evaluated the treatment effects of E-101 solution and its oxidative products on ultrastructure changes and microbicidal activity against methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli. Time-kill and transmission electron microscopy studies were also performed using formulations with pMPO or GO omitted. The glutathione membrane protection assay was used to study the neutralization of reactive oxygen species. The potency of E-101 solution was also measured in the presence of serum and whole blood by MIC and minimal bactericidal concentration (MBC) determinations. E-101 solution demonstrated rapid bactericidal activity and ultracellular changes in MRSA and E. coli cells. When pMPO was omitted, high levels of H2O2 generated from GO and glucose demonstrated slow microbicidal activity with minimal cellular damage. When GO was omitted from the formulation, no antimicrobial activity or cellular damage was observed. Protection from exposure to E-101 solution reactive oxygen species in the glutathione protection assay was competitive and temporary. E-101 solution maintained its antimicrobial activity in the presence of inhibitory substances, such as serum and whole blood. E-101 solution is a potent myeloperoxidase enzyme system with multiple oxidative mechanisms of action. Our findings suggest that the primary site where E-101 solution exerts microbicidal action is the cell membrane, by inactivation of essential cell membrane components.


  • Open Access

    Parallel Evaluation of the MALDI Sepsityper and Verigene BC-GN Assays for Rapid Identification of Gram-Negative Bacilli from Positive Blood Cultures

    by Miguel A. Arroyo, Gerald A. Denys

    Rapid identification of microorganisms from positive blood cultures has improved clinical management and antimicrobial stewardship. The advent of matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has reduced the time to identification of cultured isolates and is now often the definitive method used in the clinical microbiology laboratory. The commercial in vitro diagnostic MALDI Sepsityper (Sepsityper) kit has the potential for standardization and clinical routine use for the rapid identification of a broad range of bacteria from positive blood cultures. In this study, we performed a parallel evaluation of the Sepsityper (Bruker Daltonics, Billerica, MA) and the Verigene BC-GN (BC-GN) assays (Nanosphere, Inc., Northfield, IL) for the identification of Gram-negative bacilli. A total of 210 Bactec bottles demonstrating Gram-negative bacilli were prospectively enrolled for this study. Among these, 200 monomicrobial cultures were included in the comparative analysis. For monomicrobial cultures, the BC-GN detected 85% (170/200) compared to that detected by routine culture while the Sepsityper detected 94% (188/200) and 91% (181/200) to the genus and species levels, respectively. Comparable positive percentage agreement and negative percentage agreement were observed between the Sepsityper (96.5% and 98.8%, respectively) and the BC-GN (99.4% and 99.8%, respectively) when only ( n = 170, 85%) organisms targeted by the latter test were included in the analysis. In conclusion, the two methods evaluated in this study showed excellent performance characteristics for the identification of Gram-negative bacilli commonly isolated from blood cultures. The Sepsityper showed a broader identification range capability that may further improve clinical management and antimicrobial stewardship in patients with less frequent Gram-negative bacilli bloodstream infections.


  • Multicenter Evaluation of the Portrait Staph ID/R Blood Culture Panel for Rapid Identification of Staphylococci and Detection of the mecA Gene

    by Gerald A. Denys, Vanessa Collazo-Velez, Stephen Young, Judy A. Daly, Marc Roger Couturier, Matthew L. Faron, Blake W. Buchan, Nathan Ledeboer

    Bloodstream infections are a leading cause of morbidity and mortality in the United States and are associated with increased health care costs. We evaluated the Portrait Staph ID/R blood culture panel (BCP) multiplex PCR assay (Great Basin Scientific, Salt Lake City, UT) for the rapid and simultaneous identification (ID) of Staphylococcus aureus , Staphylococcus lugdunensis , and Staphylococcus species to the genus level and the detection of the mecA gene directly from a positive blood culture bottle. A total of 765 Bactec bottles demonstrating Gram-positive cocci in singles or clusters were tested during the prospective trial at 3 clinical sites. The Portrait Staph ID/R BCP results were compared with results from conventional biochemical and cefoxitin disk methods performed at an independent laboratory. Discordant ID and mecA results were resolved by rpoB gene sequencing and mecA gene sequencing, respectively. A total of 658 Staphylococcus species isolates ( S. aureus , 211 isolates; S. lugdunensis , 3 isolates; and Staphylococcus spp., 444 isolates) were recovered from monomicrobial and 33 polymicrobial blood cultures. After discrepant analysis, the overall ratios of Portrait Staph ID/R BCP positive percent agreement and negative percent agreement were 99.4%/99.9% for Staphylococcus ID and 99.7%/99.2% for mecA detection.


  • Open Access

    Five-Year Longitudinal Assessment (2008 to 2012) of E-101 Solution Activity against Clinical Target and Antimicrobial-Resistant Pathogens

    by Gerald A. Denys, Chris M. Pillar, Daniel F. Sahm, Peter O'HAnley, Jackson T. Stephens

    This study summarizes the topical E-101 solution susceptibility testing results for 760 Gram-positive and Gram-negative target pathogens collected from 75 U.S. sites between 2008 and 2012 and 103 ESKAPE pathogens. E-101 solution maintained potent activity against all bacterial species studied for each year tested, with MICs ranging from <0.008 to 0.25 μg porcine myeloperoxidase (pMPO)/ml. These results confirm that E-101 solution retains its potent broad-spectrum activity against U.S. clinical isolates and organisms with challenging resistance phenotypes.