Seung-Man Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Seung-Man Park has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christoph H. Grein
Department of Physics, University of Illinois, Chicago, Illinois 60607
2 shared publications Christoph H. Grein
University of Illinois at Chicago
1 shared publicationHee Chul Lee
Korea Advanced Institute of Science and Technology, Department of Electrical Engineering, 335 Gwahangno, Yuseong-gu, Daejeon 305-701, Republic of Korea
1 shared publicationSang-Wook Kim
Hoseo Univ, Dept Nanobiotron, 20,Hoseo Ro 79Beon Gil, Asan 31499, Choongnam, South Korea
1 shared publicationSeungoh Han
Hoseo University, Department of Robotics Engineering, 79-20 Hoseoro Babang-eup, Asan, Choongnam 336-795, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Independently Accessible Dual-Band Barrier Infrared Detector Using Type-II Superlattices
We report a novel dual-band barrier infrared detector (DBIRD) design using InAs/GaSb type-II superlattices (T2SLs). The DBIRD structure consists of back-to-back barrier diodes: a “blue channel” (BC) diode which has an nBp architecture, an n-type layer of a larger bandgap for absorbing the blue band infrared/barrier/p-type layer, and a “red channel” (RC) diode which has a pBn architecture, a p-type layer of a smaller bandgap for absorbing the red band infrared/barrier/n-type layer. Each has a unipolar barrier using a T2SL lattice matched to a GaSb substrate to impede the flow of majority carriers from the absorbing layer. Each channel in the DBIRD can be independently accessed with a low bias voltage as is preferable for high-speed thermal imaging. The device modeling of DBIRDs and simulation results of the current–voltage characteristics under dark and illuminated conditions are also presented. They predict that the dual-band operation of the DBIRD will produce low dark currents and 45–56% quantum efficiencies for the in-band photons in the BC with = 5.58 μm, and a nearly constant 32% in the RC with = 8.05 μm. The spectral quantum efficiency of the BC for 500 K blackbody radiation is approximately 50% over the range of = 3–4.7 μm, while that of the RC has a peak of 42% at 5.9 μm. The DBIRD may provide improved high-speed dual-band imaging in comparison with NBn dual-band detectors.Open AccessIndependently Accessible Dual-Band Barrier Infrared Detector Using Type-II Superlattices
We report a novel dual-band barrier infrared detector (DBIRD) design using InAs/GaSb type-II superlattices (T2SLs). The DBIRD structure consists of back-to-back barrier diodes: a “blue channel” (BC) diode which has an nBp architecture, an n-type layer of a larger bandgap for absorbing the blue band infrared/barrier/p-type layer, and a “red channel” (RC) diode which has a pBn architecture, a p-type layer of a smaller bandgap for absorbing the red band infrared/barrier/n-type layer. Each has a unipolar barrier using a T2SL lattice matched to a GaSb substrate to impede the flow of majority carriers from the absorbing layer. Each channel in the DBIRD can be independently accessed with a low bias voltage as is preferable for high-speed thermal imaging. The device modeling of DBIRDs and simulation results of the current–voltage characteristics under dark and illuminated conditions are also presented. They predict that the dual-band operation of the DBIRD will produce low dark currents and 45–56% quantum efficiencies for the in-band photons in the BC with = 5.58 μm, and a nearly constant 32% in the RC with = 8.05 μm. The spectral quantum efficiency of the BC for 500 K blackbody radiation is approximately 50% over the range of = 3–4.7 μm, while that of the RC has a peak of 42% at 5.9 μm. The DBIRD may provide improved high-speed dual-band imaging in comparison with NBn dual-band detectors. - Open Access
- 5 April 2024
- Published by MDPI AG in Preprints.org
Independently Accessible Dual-band Barrier Infrared Detector using Type-II Superlattices
We report a novel dual-band barrier infrared detector (DBIRD) design using type-II superlattices (T2SLs). The DBIRD structure consists of back-to-back barrier diodes: a "blue channel" (BC) diode which has an nBp architecture, an n-type layer of larger bandgap for absorbing blue band infrared/barrier/p-type layer, and a "red channel" (RC) diode which has an pBn architecture, a p-type layer of smaller bandgap for absorbing red band infrared/barrier/n-type layer. Each has a unipolar barrier using a T2SL lattice matched to a GaSb substrate to impede the flow of majority carriers from the absorbing layer. Each channel in the DBIRD can be independently accessed with a low bias voltage, as is preferable for high-speed thermal imaging. Device modeling of DBIRDs and simulation results of the current-voltage characteristics under dark and illuminated conditions are also presented. They predict that dual-band operation of the DBIRD will produce low dark currents and 27-33% quantum efficiencies for the in-band photons in the BC with λc=5.58 μm, and a nearly-constant 33% in the RC with λc=8.05 μm. The spectral quantum efficiency of the BC for 500 K blackbody radiation is approximately 20% over the range of λ=3 − 4.2 μm, while that of the RC has a peak of 42% at 5.7 μm. The DBIRD may provide improved high-speed dual-band imaging in comparison with NBn dual-band detectors.
- 5 April 2024
- Published by MDPI AG in Preprints.org
Open AccessIndependently Accessible Dual-band Barrier Infrared Detector using Type-II Superlattices
We report a novel dual-band barrier infrared detector (DBIRD) design using type-II superlattices (T2SLs). The DBIRD structure consists of back-to-back barrier diodes: a "blue channel" (BC) diode which has an nBp architecture, an n-type layer of larger bandgap for absorbing blue band infrared/barrier/p-type layer, and a "red channel" (RC) diode which has an pBn architecture, a p-type layer of smaller bandgap for absorbing red band infrared/barrier/n-type layer. Each has a unipolar barrier using a T2SL lattice matched to a GaSb substrate to impede the flow of majority carriers from the absorbing layer. Each channel in the DBIRD can be independently accessed with a low bias voltage, as is preferable for high-speed thermal imaging. Device modeling of DBIRDs and simulation results of the current-voltage characteristics under dark and illuminated conditions are also presented. They predict that dual-band operation of the DBIRD will produce low dark currents and 27-33% quantum efficiencies for the in-band photons in the BC with λc=5.58 μm, and a nearly-constant 33% in the RC with λc=8.05 μm. The spectral quantum efficiency of the BC for 500 K blackbody radiation is approximately 20% over the range of λ=3 − 4.2 μm, while that of the RC has a peak of 42% at 5.7 μm. The DBIRD may provide improved high-speed dual-band imaging in comparison with NBn dual-band detectors.
- 13 March 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (3) , 1255-1260
A Comprehensive Study on Safety-Indicating Parameters of High Flash Light Sources
- 13 March 2020
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 15 (3) , 1255-1260
A Comprehensive Study on Safety-Indicating Parameters of High Flash Light Sources
- 30 September 2019
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 48 (12) , 8163-8171
A Plausible SAM IR APD with HgCdTe Heterojunctions
- 30 September 2019
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 48 (12) , 8163-8171
A Plausible SAM IR APD with HgCdTe Heterojunctions
- 25 February 2017
- Published by Korean Journal of Optics and Photonics in Korean Journal of Optics and Photonics
- Vol. 28 (1) , 16-21
Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source
Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source Radiometry;Exposure limit Radiance;Exposure limit distance;High intensity light source;Eye protection; A systematic understanding of the effects of high-intensity flash sources on the human eye is strongly needed, not only for proper use of the sources, but for human eye health. In this study, the exposure-limit distance (ELD), indicating the minimal safe distance in case of seeing by chance a high-intensity flash, is proposed. The optical procedures to determine the ELD of a high-intensity flash are clarified, and the dependence of ELD on its parameters such as luminous intensity, duration, and radius of a flash are thoroughly investigated. From this investigation it is obvious that, while being weakly dependent on duration, the ELD is nearly proportional to the luminous intensity and the radius of a flash. The proposed ELD as an intuitive safety-indicating parameter is more useful and intuitive than the other characteristic parameters of a high-intensity flash. The ELD is expected to be an essential parameter as a safety indicator, to characterize the performance of a high-intensity flash and to promote the safety of the human eye.
- 25 February 2017
- Published by Korean Journal of Optics and Photonics in Korean Journal of Optics and Photonics
- Vol. 28 (1) , 16-21
Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source
Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source Radiometry;Exposure limit Radiance;Exposure limit distance;High intensity light source;Eye protection; A systematic understanding of the effects of high-intensity flash sources on the human eye is strongly needed, not only for proper use of the sources, but for human eye health. In this study, the exposure-limit distance (ELD), indicating the minimal safe distance in case of seeing by chance a high-intensity flash, is proposed. The optical procedures to determine the ELD of a high-intensity flash are clarified, and the dependence of ELD on its parameters such as luminous intensity, duration, and radius of a flash are thoroughly investigated. From this investigation it is obvious that, while being weakly dependent on duration, the ELD is nearly proportional to the luminous intensity and the radius of a flash. The proposed ELD as an intuitive safety-indicating parameter is more useful and intuitive than the other characteristic parameters of a high-intensity flash. The ELD is expected to be an essential parameter as a safety indicator, to characterize the performance of a high-intensity flash and to promote the safety of the human eye.
- Open Access
- 1 April 2014
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 53 (4) , 043104
Analytical model for the electro-thermal feedback effect in a microbolometer infrared focal plane array
An analytical model for the electro-thermal feedback effect in a microbolometer infrared focal plane array is presented. The presented model is the integrated optical-electro-thermal model, in which the electro-thermal feedback effect incorporated with the response of incident IR can be described. In addition, since the model is based on physics, the model parameters also have their own physical meaning. This analytical model can be easily utilized to describe the temperature increase caused by the applied heat sources and has a unique feature describing capability of optical-electro-thermal analysis in a quasi-steady-state, which can hardly be performed with thermal analysis tools based on the finite element method. The model shows that the temperature of the microbolometer in this study can be increased 7.1% to 18.6% more by the electro-thermal feedback effect.
- 1 April 2014
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 53 (4) , 043104
Open AccessAnalytical model for the electro-thermal feedback effect in a microbolometer infrared focal plane array
An analytical model for the electro-thermal feedback effect in a microbolometer infrared focal plane array is presented. The presented model is the integrated optical-electro-thermal model, in which the electro-thermal feedback effect incorporated with the response of incident IR can be described. In addition, since the model is based on physics, the model parameters also have their own physical meaning. This analytical model can be easily utilized to describe the temperature increase caused by the applied heat sources and has a unique feature describing capability of optical-electro-thermal analysis in a quasi-steady-state, which can hardly be performed with thermal analysis tools based on the finite element method. The model shows that the temperature of the microbolometer in this study can be increased 7.1% to 18.6% more by the electro-thermal feedback effect.