EREric Rompen

Eric Rompen

*This is an algorithmically generated author record based on publicly available information.

Eric Rompen has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Minocycline Hydrochloride as an Adjuvant Therapy for a Guided Bone Augmentation Procedure in The Rat Calvarium

    by Bob Biewer, Eric Rompen, Michel Mittelbronn, Gaël P. Hammer, Pascale Quatresooz, Felix Kleine Borgmann

    This in vivo study reports the influence of minocycline-HCl administration on extra-skeletal bone generation in a Guided Bone Augmentation model, utilizing titanium caps placed on the intact as well as perforated calvaria of rats. The test group was administered 0.5 mg/mL minocycline-HCl with the drinking water, and the amount of bone tissue in the caps was quantified at three time points (4, 8 and 16 weeks). A continuously increased tissue fill was observed in all groups over time. The administration of minocycline-HCl as well as perforation of the calvaria increased this effect, especially with regard to mineralization. The strongest tissue augmentation, with 1.8 times that of the untreated control group, and, at the same time, the most mineralized tissue (2.3× over untreated control), was produced in the combination of both treatments, indicating that systemic administration of minocycline-HCl has an accelerating and enhancing effect on vertical bone augmentation.


  • Open Access

    Effects of Low Intensity Pulsed Ultrasound Stimulation on the Temporal Dynamics of Irradiated Bone Tissue Healing: A Histomorphometric Study in Rabbits

    by Bob Biewer, Felix Kleine-Borgmann, Gaël P. Hammer, Eric H. Rompen, Michel Mittelbronn, Pascale Quatresooz

    The present study evaluated the influence of Low-Intensity Pulsed Ultrasound (LIPUS) on the regeneration processes of non-critical-size bone defects in irradiated and non-irradiated rabbit tibias. Bone defects were surgically created on both tibiae of six rabbits. The control group had no additional treatment. In one intervention group, one tibia was irradiated with 15 Gy in a single dose. A second group was treated with LIPUS, and a third with a combination of both treatments. The control samples showed 83.10% ± 17.79% of bone repair after 9 weeks, while the irradiated bone had regenerated significantly less during the same period (66.42% ± 29.36%). The LIPUS treatment on irradiated bones performed a 79.21% ± 21.07% bone fill and could not significantly improve the response compared to the non-treated irradiated specimens. However, LIPUS treatment on non-irradiated bone showed bone formations beyond the size defect (115.91% ± 33.69%), which was a highly significant increase when compared to the control group or any irradiated group. The application of ultrasound to healthy bone produced highly significant and enhanced bone formations with 36.70% more regenerated bone when compared to the same application on irradiated bone. LIPUS vibration stimuli may be considered as a promising complementary treatment approach in non-irradiated bone regeneration procedures to shorten the treatment and enhance bone healing. In irradiated bones, the effect of ultrasound application is less clear, and further studies are needed to refine the dynamics of the present results.


  • Open Access

    Clinical Performance of a Novel Two-Piece Abutment Concept: Results from a Prospective Study with a 1-Year Follow-Up

    by Giacomo Fabbri, Tristan Staas, Tomas Linkevicius, Valda Valantiejiene, Oscar González-Martin, Eric Rompen

    Development of a stable and healthy soft-tissue barrier around dental implants is key to long-term success of implant-supported prostheses. The novel two-piece abutment concept shifts the prosthetic interface to the soft-tissue level to protect bone interface/connective tissue during the healing phase and restorative procedures. This prospective study included 72 patients treated with 106 implants to support a single-tooth or a three-unit bridge restored with two-piece abutments. The evaluation included marginal bone level change (MBLC), implant and prosthetic survival, soft-tissue health including keratinized mucosa height and mucosal margin position, patient quality of life (QoL) and satisfaction, and clinician satisfaction and ease-of-use rating of the concept. Mean MBLC from implant placement to 1 year was −0.36 ± 1.26 mm (n = 89), the 1-year implant and prosthetic survival rates were 97.1 and 96.7%, respectively, while keratinized mucosa height increased from 2.9 ± 1.2 mm at prosthetic delivery to 3.2 ± 1.3 mm, and mucosal margin migrated coronally by 0.49 ± 0.61 mm by 1 year. Patient satisfaction and QoL were high. Clinicians were satisfied with the esthetic and functional results and rated the concept as easy to use. In conclusion, the novel two-piece abutment concept promotes good peri-implant tissue health, while providing an easy-to-use workflow and high treatment satisfaction to both patients and clinicians.


  • Open Access

    Minocycline Hydrochloride as a Potential Adjuvant to Improve Osteoconductive and Osteoinductive Properties of Bone Substitutes in an Extra-Skeletal Bone Augmentation Model: Preliminary Observations in Rats

    by Bob Biewer, Dorien Van Hede, Eric Rompen, Michel Mittelbronn, Pascale Quatresooz, Felix B. Kleine Borgmann

    Objectives The present study was performed to determine if minocycline HCl could influence the behavior of deproteinized bovine bone mineral (DBBM) and bioactive glass (BG) particles when used as filler material for new bone generation in a guided bone augmentation model. Materials and Methods Two occlusive titanium caps were placed on the rat calvaria. One filled with BG particles, the second with DBBM particles, both previously mixed with blood (control). In minocycline HCl loaded groups (experimental), grafts were additionally placed into a minocycline solution. Samples were harvested after 4, 8, and 16 weeks. Half of the samples were embedded in methylmethacrylate for undecalcified histology and the other half was fixed, decalcified, and embedded in paraffin for classical histologic analysis. Results The control groups highlighted osteoconductive and osteoinductive responses associated to BG particles, as well as an osteoconductive reaction, in DBBM sections. The addition of minocycline HCl to BG particles had no measurable influence on the result. In minocycline HCl loaded DBBM sections; however, areas of spontaneous ossification could be observed after 8 and 16 weeks. Conclusion Our observations suggest that minocycline HCl may add some osteoinductive properties to DBBM within the limitations of this study design. Further investigations are needed to refine the present results.

  • Open Access

    Tunnel/Pouch versus Coronally Advanced Flap Combined with a Connective Tissue Graft for the Treatment of Maxillary Gingival Recessions: Four-Year Follow-Up of a Randomized Controlled Trial

    by Souheil Salem, Leila Salhi, Laurence Seidel, Geoffrey Lecloux, Eric Rompen, France Lambert

    Background: The long-term stability after soft tissue graft for covering gingival recession remains a pivotal goal for both patient and periodontist. Therefore, the aim of this study was to compare the four-year outcomes of the coronally advanced flap (CAF) versus the pouch/tunnel (POT) technique, both combined with connective tissue graft (CTG), for gingival recession treatment. Methods: Forty patients were initially randomly assigned to the control group (CAF + CTG; N = 20) and the test group (POT + CTG; N = 20). Clinical outcomes included mean root coverage (MRC) and complete root coverage (CRC), gingival thickness (GT), and keratinized tissue (KT) gain. Esthetic outcomes were also analyzed using the pink esthetic score (PES) and patient-reported outcome measures (PROMs). All outcomes initially assessed at six months were extended to four years post-surgery. Results: No significant differences were observed between the two patient groups in terms of MRC and CRC. At four years, significantly greater GT and KT gain were noted in the POT + CTG group, and tissue texture enhancement was also more prominent in the test group. Conclusions: The POT + CTG technique allows for long-term clinical coverage of gingival recessions comparable to that of the CAF + CTG technique, but it potentially improves gingival thickness, keratinized tissue and esthetic results.


  • Open Access

    Q-Switch Nd:YAG Laser-Assisted Elimination of Multi-Species Biofilm on Titanium Surfaces

    by Melanie Namour, Tim Verspecht, Marwan El Mobadder, Wim Teughels, Andre Peremans, Samir Nammour, Eric Rompen

    (1) Background: The relatively high prevalence of peri-implantitis (PI) and the lack of a standard method for decontamination of the dental implant surface have pushed us to conduct further research in the field. Bacterial biofilms were found to play a primordial role in the etiology of PI. Therefore, the aim is to evaluate the efficacy of a laser-assisted elimination of biofilm protocol in the removal of a multi-species biofilm on titanium surfaces. (2) Methods: In total, 52 titanium discs (grade 4) were used. The study group consisted of 13 titanium disks contaminated with multi-species biofilms and subsequently irradiated with the laser (T + BF + L). The control groups consisted of the following types of titanium disks: 13 contaminated with multi-species biofilms (T + BF), 13 sterile and irradiated (T + L), 13 sterile and untreated (T). Q-Switch Nd:YAG laser Irradiation parameters were the following: energy density equal to 0.597 J/cm2 per pulse, power equal to 270 milliwatt per pulse, 2.4 mm of spot diameter, and 10 Hz repetition rate for pulse duration of six nanoseconds (ns). The laser irradiation was made during 2 s of total time in non-contact and at 0.5 mm away from the titanium disc surface. After treatment, presence of biofilms on the disks was evaluated by staining with crystal violet (CV), which was measured as optical density at six hundred thirty nm, and statistical analyses were done. (3) Results: the optical density values were 0.004 ± 0.004 for the study group T + BF + L, 0.120 ± 0.039 for group T + BF, 0.006 ± 0.003 for group T + L, and 0.007 ± 0.007 for group T. For the study group, laser treatment resulted in a total elimination of the biofilm, with mean values statistically significantly lower than those of contaminated titanium surfaces and similar to those of sterile titanium surfaces. (4) Conclusions: Our irradiation protocol provided a significant elimination of the multi-species biofilm on titanium surfaces. Laser treated titanium surfaces were biofilm-free, similar to the sterile ones.


  • Open Access

    Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface

    by Melanie Namour, Marwan El Mobadder, Delphine Magnin, André Peremans, Tim Verspecht, Wim Teughels, Laurent Lamard, Samir Nammour, Eric Rompen

    Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.