HRHuub H. van Rossum

Huub H. van Rossum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Huub H. van Rossum has a total of 172 co-authors. Here are the top co-authors by number of shared publications:

  • Daan van Den Broek

    4 shared publications
  • Ruben Moritz

    Department of Laboratory Medicine , Netherlands Cancer Institute , Amsterdam , The Netherlands

    4 shared publications
  • Catharina M. Korse

    Department of Laboratory Medicine, Netherlands Cancer Institute, Amsterdam, The Netherlands

    3 shared publications
  • Hans Kemperman

    Department of Clinical Chemistry and Haematology University Medical Center Utrecht Utrecht, The Netherlands

    3 shared publications
  • Henk G. van der Poel

    Netherlands Canc Inst, Dept Urol, Amsterdam, Netherlands

    3 shared publications
  • Lennart J. van Winden

    Netherlands Canc Inst, Dept Lab Med, Amsterdam, Netherlands

    3 shared publications

Latest Publications

  • Open Access

    Verification of a previously obtained EQA based MUC1/CA15-3 harmonisation procedure

    by Huub H. van Rossum, Theodora C. Linders, Henk Huijgen, Ruben E. A. Musson, Ayşe Y. Demir, Michael J. Duffy, Melanie Moore

    Objectives: MUC1/CA 15-3 is the most widely used circulating marker for monitoring treatment in patients with advanced breast cancer. Previous studies demonstrated that MUC1/CA 15-3 tests are insufficiently harmonised and an EQA-based harmonisation procedure has been developed. This study aims to validate the obtained MUC1/CA 15-3 harmonisation procedure and to explore the suitability of MUC1/CA 15-3 materials as a base for developing future MUC1/CA 15-3 reference materials. Methods: Sera from 45 patients were obtained and five additional samples were prepared from commercial MUC1/CA 15-3 materials. All samples were analyzed by measurement procedures of Abbott Alinity, Beckman DxI, Roche Cobas and Siemens Atellica. Data analysis included application of the previously obtained MUC1/CA 15-3 harmonisation procedure that required recalibration of Beckman DxI only, pre-and post-harmonisation Passing-Bablok regression, Spearman correlation coefficient and Bland-Altman difference analyses. Suitability of the MUC1/CA 15-3 materials as basis of future standards was also investigated. Results: The slopes obtained from the regression analysis of individual MUC1/CA15-3 assays ranged from 0.598 to 1.96 pre-harmonisation and 0.8448 to 1.150 post-harmonisation. The mean difference of individual measurement procedures with the consensus mean improved from −26.65% to 22.83% before harmonisation to −12.78% to 10.95% after harmonisation. The difference between the MUC1/CA 15-3 spiked materials and the patient sample mean differences were ≤10,1% and fell within the 95% limits of agreement. Conclusions: The EQA-based mathematical harmonisation procedure for MUC1/CA 15-3 resulted in improved MUC1/CA 15-3 harmonisation with real-world clinical samples. The MUC1/CA 15-3 materials provided a suitable base for further exploration as reference materials.

  • Open Access

    Beyond proficiency testing: Leveraging commutable External Quality Assessment data to harmonize tumor markers and refine medical decision points

    by Jong Do Seo, Huub H. Van Rossum, Yeo-Min Yun

    Background: Serum tumor markers such as carcinoembryonic antigen (CEA), alpha-fetoprotein (AFP), and prostate-specific antigen (PSA) are crucial to clinical decision-making based on defined medical thresholds. However, significant inter-method variability and lack of harmonization limit result comparability and hinder consistent application of international guidelines. Objective: This letter proposes an expanded role for External Quality Assessment (EQA) programs as active drivers of assay harmonization beyond conventional proficiency testing. Methods: This proposal draws on recent studies evaluating the commutability of frozen human serum pools (FSPs) from the Korean Association of External Quality Assessment Service (KEQAS) and findings from EQA-based harmonization simulations. It demonstrated that harmonization of tumor markers such as CA 15-3 and CEA, is achievable. Results: KEQAS FSPs demonstrated commutability for AFP, CEA, and total PSA across major diagnostic platforms. Simulation results indicated that “in silico” recalibration substantially reduced inter-method variability; for example, the bias range for CA 15-3 was reduced from [−29.28%, 9.86%] to [−0.09%, 0.12%], and recalibrating outlier methods for CEA improved the alignment also. Conclusions: EQA programs can serve as practical harmonization hubs by leveraging commutable materials and implementing EQA-driven recalibration. Such approaches can help that medical decision points, retain consistent clinical significance across diverse analytical systems.


  • Open Access

    Clinical validation and implementation of mSTOP, a machine learning-based, longitudinal prediction model for the early identification of non-small cell lung cancer patients who not benefit from immune checkpoint inhibitor treatment

    by Huub H. van Rossum, Marije van der Schaar, Alessandra I. G. Buma, Ruben Moritz, Dorieke E. M. van Balen, Antonius E. van Herwaarden, Ruben L. Smeets, Jacobus A. Burgers, Michel M. van Den Heuvel, Jasper Smit, et al.

    Objectives: There has been a lot of interest in the field of laboratory medicine regarding the use of machine learning (ML)-based prediction models. The longitudinal ML-based Serum Tumor marker-based Outcome Prediction (STOP) model was previously developed to identify non-small cell lung cancer (NSCLC) patients who do not respond to immune checkpoint inhibitor treatment. Due to significant preanalytical challenges with the NSE tumor marker, the best-performing alternative model, mSTOP model based on CEA and Cyfra 21-1, was selected for validation of its diagnostic accuracy, clinical- and financial impact. Methods: Diagnostic accuracy was based on a dual-center validation cohort of 242 metastatic NSCLC patients. The clinical and financial impact of mSTOP was investigated using a previously described Discrete Event Simulation (DES) model with under-treatment, overtreatment, and financial impact as output parameters. Finally, an ICT system and a multi-parametric QC strategy were designed to enable real-time operation and quality control of mSTOP. Results: mSTOP identified 35.1 % of nonresponding patients, with a positive predictive value (PPV) of 84.8 %, which was comparable to CT-imaging. In combination with CT- imaging, the PPV increased to 95.7 %, identifying 19.8 % of non-responding patients. Estimated avoided overtreatment ranged from 6.7 % to 17.4 %, reflecting a financial savings of €569 to €5306 per patient, depending on the clinical mSTOP scenario used. The developed ICT system incorporated the mSTOP algorithm within the laboratory and healthcare information system. It allowed for continuous real-time mSTOP calculations. Conclusions: The obtained diagnostic mSTOP characteristics and their corresponding clinical and financial characteristics prompted the development of an ICT system that supports automated, real-time, clinical application.


  • Open Access

    Serological Response Patterns to Assess Treatment Outcomes in Advanced Non-Small Cell Lung Cancer: A Real-World Exploratory Multi-Center Observational Cohort Study

    by Alessandra I. G. Buma, Femke Laarakker, Frederik A. van Delft, Milou M. F. Schuurbiers, Jasper Smit, Antonius E. van Herwaarden, Huub H. van Rossum, Michel M. van Den Heuvel

    Background: Previous studies mainly investigated singular serum tumor marker (STM) measurements for the management of advanced cancer patients, resulting in differences between recommended cut-off points and associated accuracies in evaluating treatment outcomes. We aimed to determine which STM dynamics recur during treatment in advanced non-small cell lung cancer (NSCLC) patients with disease control three months after starting with immune checkpoint inhibitor (ICI)-containing treatment and explore whether these dynamics retain information on treatment outcomes. Methods: This real-world exploratory multi-center observational cohort study included advanced NSCLC patients with clinical and radiological disease control three months after starting with ICI-containing treatment and at least three STM measurements for at least one STM during treatment. STM dynamics visualized for all patients were subclassified into three serological response patterns by two investigators who were blinded for treatment outcomes. Results: Between March 2013 and January 2023, 256 patients were included at two thoracic oncology outpatient clinics in The Netherlands. Kaplan–Meier survival analyses showed a significant association between the serological response patterns and both progression-free survival (PFS) and overall survival (OS). Additionally, the serological response patterns could be used to distinguish a durable response versus secondary treatment resistance, and oligoprogression versus systemic progression. Conclusions: Our findings underscore the value of monitoring STM dynamics in advanced NSCLC patients during ICI-containing treatment to improve response classification and decision-making in clinical practice. Future studies should explore the value of the identified dynamics in other tumor- and systemic treatment-types and tumor cell analytes for assessing treatment outcomes across multiple indications.

  • Validation of (self-collected) capillary blood using a topper collection system as alternative for venous sampling for 15 common clinical chemistry analytes

    by Rümeysa Geujar, Dilana Treffers, Maaike Roelofs, Anna van Dongen, Kalpana Ramkisoensing, Rixt Even, Huub H. van Rossum

    Objectives: Home blood sampling for clinical purposes has gained much interest. This study validates the recently developed Topper-based capillary blood collection procedure for 15 commonly used chemistry analytes. Methods: A total of 120 study participants (21 healthy volunteers and 99 patients) were enrolled. A venous sample was obtained and then participants were asked to self-collect blood by the Topper system (SelfSafeSure Blood Collection Devices). Collected sera were analyzed for 15 common clinical chemistry analytes and the serum indices on a Cobas Pro (Roche) system. Spearman correlations, Passing-Bablok regression analysis, and Bland-Altman difference analysis were performed. Comparability was determined using allowable bias criteria based on biological variation (EFLM database). Results: In 113 out of 120 (94 %) self-collections a sample was obtained that allowed for the analysis of at least one analyte. Bland-Altman difference analysis showed that glucose and uncorrected AST did not meet the minimum bias criterion, creatinine and albumin were within the minimum bias criterion and urea and calcium were within the desirable bias criterion. ALP, corrected AST, ALT, total- HDL- and LDL-cholesterol, CRP, GGT, total protein and triglycerides were all within the optimal bias criterion. Conclusions: Our study demonstrates that self-collected capillary blood can be used as a reliable alternative to venous sampling for most, if not all, analytes studied. Based on the analyte stability prior to sample processing, home sampling appears to be a reliable sampling option for a selection of these analytes.


  • Open Access

    Psychiatric and cognitive function in patients with serotonin producing neuroendocrine tumors

    by Maryse J. Luijendijk, Margot E. T. Tesselaar, Huub H. van Rossum, Martijn van Faassen, Catharina M. Korse, Wieke H. M. Verbeek, Jocelyn R. Spruit, Pernilla C. Scheelings, Eva H. Hooghiemstra, Ido P. Kema, et al.

    Cognitive and psychiatric problems are common in cancer patients, but literature on patients with neuroendocrine tumors (NET) is scarce. In a subset of these patients, the tumor produces serotonin, causing physical symptoms known as carcinoid syndrome. This peripheral overproduction of serotonin may cause central depletion of its precursor tryptophan, potentially resulting in cognitive and psychiatric problems. Therefore, we investigated cognitive and psychiatric function in patients with a serotonin overproduction and the association with this serotonin overproduction. Eighty-one patients with a serotonin-producing metastatic ileal NET underwent standardized neuropsychological and psychiatric assessment. Blood and urine samples were collected to determine concentrations of serotonin, its precursor tryptophan, and metabolite (5-HIAA). Multivariate normative comparison was applied to determine the prevalence of cognitive impairment. Separate linear regressions of serotonin, tryptophan, and 5-HIAA concentrations on cognitive function, depressive symptoms, and anxiety symptoms were performed, corrected for age, sex, education, and/or duration of illness. We found an 11% prevalence of cognitive impairment and a 20% prevalence of psychiatric disorders. Cognitive function was not related to measures of peripheral serotonin production. Unexpectedly, depressive symptoms were significantly associated with lower serum serotonin concentrations and elevated serum tryptophan concentrations. Cognitive symptoms of anxiety were also associated with elevated tryptophan concentrations. Concluding, cognitive or psychiatric problems occur in a minority of patients with NET and cannot be explained by tryptophan depletion following tumor-related serotonin production.

  • Open Access

    The oestrous cycle stage affects mammary tumour sensitivity to chemotherapy

    by Laura Bornes, Lennart J. van Winden, Veerle C. M. Geurts, Beaunelle de Bruijn, Leyla Azarang, Mirthe Lanfermeijer, Marika Caruso, Natalie Proost, Manon Boeije, Jeroen O. Lohuis, et al.

    The response of breast cancer to neoadjuvant chemotherapy (NAC) varies substantially, even when tumours belong to the same molecular or histological subtype1. Here we identify the oestrous cycle as an important contributor to this heterogeneity. In three mouse models of breast cancer, we show reduced responses to NAC when treatment is initiated during the dioestrus stage, when compared with initiation during the oestrus stage. Similar findings were observed in retrospective premenopausal cohorts of human patients. Mechanistically, the dioestrus stage exhibits systemic and localized changes, including (1) an increased number of cells undergoing epithelial-to-mesenchymal transition linked to chemoresistance2,3,4 and (2) decreased tumour vessel diameter, suggesting potential constraints to drug sensitivity and delivery. In addition, an elevated presence of macrophages, previously associated with chemoresistance induction5, characterizes the dioestrus phase. Whereas NAC disrupts the oestrous cycle, this elevated macrophage prevalence persists and depletion of macrophages mitigates the reduced therapy response observed when initiating treatment during dioestrus. Our data collectively demonstrate the oestrous cycle as a crucial infradian rhythm determining chemosensitivity, warranting future clinical studies to exploit optimal treatment initiation timing for enhanced chemotherapy outcomes.