GGGuang-Yang Gou

Guang-Yang Gou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guang-Yang Gou has a total of 123 co-authors. Here are the top co-authors by number of shared publications:

  • He Tian

    School of Integrated Circuits, Tsinghua University, Beijing, China

    6 shared publications
  • Tian-Ling Ren

    School of Integrated Circuits & Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China

    5 shared publications
  • Yi Yang

    School of Integrated Circuits & Beijing National Research on Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China

    5 shared publications
  • Jianhai Sun

    State Key Laboratory of Transducer Technology, Aerospace Information Research Institute (AIR), Chinese Academy of Sciences, Beijing, China

    4 shared publications
  • Jianqun Cheng

    School of Electronics and Communication Engineering, Quanzhou University of Information Engineering, Quanzhou 362000, China

    4 shared publications
  • Tianjun Ma

    School of Integrated Circuit, Quanzhou University of Information Engineering, Quanzhou, China

    4 shared publications

Latest Publications

  • A Dual-Modal Silent Speech Interface via Surface Electromyography (sEMG) and Vibration Sensing

    by Guang-Yang Gou, Yu-Sen Guo, Zi-Xuan Song, Pengyu Huo, Yulan Lu, Nan Li, Xiao-Ye Huo, Zhen Fang, Deyong Chen, Chunxiu Liu, et al.

    Human voices serve as a primary channel for rich information exchange; however, conventional acoustic speech recognition is susceptible to degradation under adverse environmental conditions or in cases of vocal impairment. Herin, we present a dual-modal silent speech recognition system that integrates hydrogel-based surface electromyography (sEMG) electrodes with a polyvinylidene fluoride (PVDF) vibration sensor to enable robust acquisition of nonacoustic throat signals. The sEMG electrodes, fabricated via a facile one-pot synthesis of poly(vinyl alcohol) (PVA)/poly(acrylic acid) (PAA) hydrogels, exhibit low interfacial impedance (270 Ω at 1 kHz), ensuring high-fidelity biopotential recording. In parallel, a 28-μm-thick PVDF piezoelectric unit demonstrates a sensitivity of 365 mV/Pa at 300 Hz and maintains a signal-to-noise ratio exceeding 48 dB across a wide frequency range (50 Hz-1 kHz), facilitating precise mechanical vibration detection. Both modalities are co-integrated onto a conformal polyimide (PI) substrate, enabling simultaneous and colocalized sensing of neuromuscular and vibrational signatures. To decode these complex spatiotemporal signals, we developed a dual-branch silent interaction network (DSI-Net), which fuses multimodal inputs to significantly improve the recognition accuracy. This system provides a scalable framework for silent, privacy-preserving human-machine communication, with potential applications in assistive technology and resilient voice interfaces.


  • Low-Frequency High-Directional Second-Order Electrochemical Vector Hydrophones

    by Qinghua Liu, Lintao Hu, Honghao Zhang, Guangyang Gou, Yulan Lu, Deyong Chen, Junbo Wang

    This paper presents two low-frequency high-directional electrochemical second-order hydrophones based on the velocity gradient pure partial derivative (VGP) and the velocity gradient mixed partial derivative (VGM) principles. Both consist of two independently vibrating first-order hydrophones, which are characterized by sensitivity of -180.12 dB (ref. 1 V/ μPa) within the 20- 400 Hz frequency range. The device is capable of simultaneously measuring first-order and second-order quantities through different signal processing methods. The first-order in-band sensitivity is -175.46 dB (ref. 1 V/ μPa), which is 4.66 dB higher than the sensitivity of a single first-order hydrophone. The sensitivity of the VGP hydrophone is -196.41 dB@400 Hz (ref. 1 V/ μPa), while the sensitivity of the VGM hydrophone is -201.83 dB@400 Hz (ref. 1 V/ μPa). The sensitivity of the second-order hydrophone shows an overall increasing trend of 6 dB per octave, with the VGP being 5.42 dB higher than the VGM. Compared to first-order hydrophones with 90° beamwidths and “8”-shaped directivities, the VGP hydrophone demonstrates a narrower “8”-shaped directivity with a beamwidth of 60°, while the VGM hydrophone features a “four-leaf” directivity with a beamwidth of 40°/30°. The results demonstrate that the directivity performances of second-order hydrophones are significantly superior to that of first-order hydrophones, implying higher positioning accuracy and greater significance for underwater target detection.


  • Multi‐Receptor Skin with Highly Sensitive Tele‐Perception Somatosensory Flexible Electronics in Healthcare: Multimodal Sensing and AI‐Powered Diagnostics

    by Yusen Guo, Pengyu Huo, Sisi Huang, Guangyang Gou, Qiliang Li

    The rapid advancement of intelligent healthcare and personalized medicine has catalyzed the development of flexible electronics, positioning them as disruptive for next‐generation medical monitoring systems. In contrast to conventional rigid devices, flexible sensors offer mechanical compliance with human tissue, enabling non‐invasive, continuous, and comfortable long‐term physiological monitoring. This review systematically examines recent progress in the field of flexible electronics, with a particular emphasis on the integration of multimodal sensing platforms and artificial intelligence (AI) algorithms. This work highlights innovations in flexible substrates, stretchable interconnects, and sensor architectures that facilitate the concurrent acquisition of electrophysiological, biophysical, and biochemical signals. The incorporation of AI, especially deep learning and edge computing, has significantly enhanced signal processing capabilities, feature extraction, and predictive analytics for early disease detection and individualized treatment planning. This work also discusses the current technical challenges including heterogeneous sensor integration, long‐term functional stability, and in vivo biocompatibility. Furthermore, this work explores emerging solutions involving novel nanomaterials, self‐powered systems via energy harvesting, and wireless communication protocols, paving the way for clinical translation. This review provides a comprehensive overview of the flexible electronics landscape, identifies critical bottlenecks, and outlines strategic directions for future research to accelerate their deployment in precision healthcare.


  • Open Access

    A 16-channel Si probe monolithically integrated with CMOS chips for neural recording

    by Guang-Yang Gou, Changhua You, Pan Yao, Yu-Sen Guo, Tie-Zhu Liu, Zi-Xuan Song, Ben-Yuan He, MingHui Yin, Xuan Zhang, Chunxiu Liu, et al.


  • Open Access

    FPGA-based Lightweight QDS-CNN System for sEMG Gesture and Force Level Recognition

    by Yusen Guo, Guangyang Gou, Pan Yao, Fupeng Gao, Tianjun Ma, Jianhai Sun, Mengdi Han, Jianqun Cheng, Chunxiu Liu, Ming Zhao, et al.

    Deep learning (DL) has been used for electromyographic (EMG) signal recognition and achieved high accuracy for multiple classification tasks. However, implementation in resource-constrained prostheses and human-computer interaction devices remains challenging. To overcome these problems, this paper implemented a low-power system for EMG gesture and force level recognition using Zynq architecture. Firstly, a lightweight network model structure was proposed by Ultra-lightweight depth separable convolution (UL-DSC) and channel attention-global average pooling (CA-GAP) to reduce the computational complexity while maintaining accuracy. A wearable EMG acquisition device for real-time data acquisition was subsequently developed with size of 36mm×28mm×4mm. Finally, a highly parallelized dedicated hardware accelerator architecture was designed for inference computation. 18 gestures were tested, including force levels from 22 healthy subjects. The results indicate that the average accuracy rate was 94.92% for a model with 5.0k parameters and a size of 0.026MB. Specifically, the average recognition accuracy for static and force-level gestures was 98.47% and 89.92%, respectively. The proposed hardware accelerator architecture was deployed with 8-bit precision, a single-frame signal inference time of 41.9μs, a power consumption of 0.317W, and a data throughput of 78.6 GOP/s.


  • Graphene-based Two-Stage Enhancement Pressure Sensor for Subtle Mechanical Force Monitoring

    by He Tian, Xiaoshi Li, Guang-Yang Gou, Jin-Ming Jian, Boyi Zhu, Shourui Ji, Hengbin Ding, Zhanfeng Guo, Yi Yang, Tian-Ling Ren

    The development of pressure sensors with high sensitivity and a low detection limit for subtle mechanical force monitoring and the understanding of the sensing mechanism behind subtle mechanical force monitoring are of great significance for intelligent technology. Here, we proposed a graphene-based two-stage enhancement pressure sensor (GTEPS), and we analyzed the difference between subtle mechanical force monitoring and conventional mechanical force monitoring. The GTEPS exhibited a high sensitivity of 62.2 kPa-1 and a low detection limit of 0.1 Pa. Leveraging its excellent performance, the GTEPS was successfully applied in various subtle mechanical force monitoring applications, including acoustic wave detection, voice-print recognition, and pulse wave monitoring. In acoustic wave detection, the GTEPS achieved a 100% recognition accuracy for six words. In voiceprint recognition, the sensor exhibited accurate identification of distinct voiceprints among individuals. Furthermore, in pulse wave monitoring, GTEPS demonstrated effective detection of pulse waves. By combination of the pulse wave signals with electrocardiogram (ECG) signals, it enabled the assessment of blood pressure. These results demonstrate the excellent performance of GTEPS and highlight its great potential for subtle mechanical force monitoring and its various applications. The current results indicate that GTEPS shows great potential for applications in subtle mechanical force monitoring.


  • Recent Advancements in Physiological, Biochemical, and Multimodal Sensors Based on Flexible Substrates: Strategies, Technologies, and Integrations

    by Tiezhu Liu, Lidan Liu, Guang-Yang Gou, Zhen Fang, Jianhai Sun, Jiamin Chen, Jianqun Cheng, Mengdi Han, Tianjun Ma, Chunxiu Liu, et al.

    Flexible wearable devices have been widely used in biomedical applications, the Internet of Things, and other fields, attracting the attention of many researchers. The physiological and biochemical information on the human body reflects various health states, providing essential data for human health examination and personalized medical treatment. Meanwhile, physiological and biochemical information reveals the moving state and position of the human body, and it is the data basis for realizing human-computer interactions. Flexible wearable physiological and biochemical sensors provide real-time, human-friendly monitoring because of their light weight, wearability, and high flexibility. This paper reviews the latest advancements, strategies, and technologies of flexibly wearable physiological and biochemical sensors (pressure, strain, humidity, saliva, sweat, and tears). Next, we systematically summarize the integration principles of flexible physiological and biochemical sensors with the current research progress. Finally, important directions and challenges of physiological, biochemical, and multimodal sensors are proposed to realize their potential applications for human movement, health monitoring, and personalized medicine.


  • Development of the Force Detecting Liner for Total Knee Arthroplasty

    by Minghui Yin, Tiezhu Liu, Tong Li, Zhenpeng Guan, Keshi Zhang, Siyuan Yin, Guangyang Gou, Jianhai Sun, Tianjun Ma, Jianqun Cheng, et al.

    With the increase in the prevalence of knee arthritis, the market for liners with force detection devices has expanded. The force detection device assists the doctor to adjust the installation position angle of the prosthesis liner during the operation. Pressure sensors made of flexible materials which are attractive for use in force detection due to their high sensitivity, fast response time, and low cost. Here, the pressure-sensing device with bendable and disposable flexible sensor arrays for force detection is fabricated. The spatial resolution of force detection is greatly improved by designing the sensor array layout through finite element simulation. The device also achieves synchronous dynamic monitoring of axial stress and tangential stress inside the knee joint, filling in the research gap of tangential stress inside the knee joint. The pressure sensors offer a dynamically stable, wide range, high sensitivity, and great consistency avenue for knee arthroplasty.


  • Open Access

    Multichannel Flexible Pulse Perception Array for Intelligent Disease Diagnosis System

    by Tiezhu Liu, Guang-Yang Gou, Fupeng Gao, Pan Yao, Haoyu Wu, Yusen Guo, Minghui Yin, Jie Yang, Tiancai Wen, Ming Zhao, et al.

    Pressure sensors with high sensitivity, a wide linear range, and a quick response time are critical for building an intelligent disease diagnosis system that directly detects and recognizes pulse signals for medical and health applications. However, conventional pressure sensors have limited sensitivity and nonideal response ranges. We proposed a multichannel flexible pulse perception array based on polyimide/multiwalled carbon nanotube-polydimethylsiloxane nanocomposite/polyimide (PI/MPN/PI) sandwich-structure pressure sensor that can be applied for remote disease diagnosis. Furthermore, we established a mechanical model at the molecular level and guided the preparation of MPN. At the structural level, we achieved high sensitivity (35.02 kPa-1) and a broad response range (0-18 kPa) based on a pyramid-like bilayer microstructure with different upper and lower surfaces. A 27-channel (3 × 9) high-density sensor array was integrated at the device level, which can extract the spatial and temporal distribution information on a pulse. Furthermore, two intelligent algorithms were developed for extracting six-dimensional pulse information and automatic pulse recognition (the recognition rate reaches 97.8%). The results indicate that intelligent disease diagnosis systems have great potential applications in wearable healthcare devices.


  • Wafer-Scale Photolithography-Pixeled Pb-Free Perovskite X-ray Detectors

    by Guan-Hua Dun, Hainan Zhang, Ken Qin, Xichao Tan, Rui Zhao, Min Chen, Yao Huang, Xiang-Shun Geng, Yuan-Yuan Li, Yuhua Li, et al.

    Pb-free perovskite material is considered to be a promising material utilized in next-generation X-ray detectors due to its high X-ray absorption coefficient, decent carrier transport properties, and relatively low toxicity. However, the pixelation of the perovskite material with an industry-level photolithography processing method remains challenging due to its poor structural stability. Herein, we use Cs2AgBiBr6 perovskite material as the prototype and investigate its interaction with photolithographic polar solvents. Inspired by that, we propose a wafer-scale photolithography patterning method, where the pixeled perovskite array devices for X-ray detection are successfully prepared. The devices based on pixeled Pb-free perovskite material show a high detection sensitivity up to 19118 ± 763 μC Gyair-1 cm-2, which is comparable to devices with Pb-based perovskite materials and superior to the detection sensitivity (∼20 μC Gyair-1 cm-2) of the commercial a-Se detector. After pixelation, the devices achieve an improved spatial resolution capacity with the spatial frequency from 2.7 to 7.8 lp mm-1 at modulation-transfer-function (MTF) = 0.2. Thus, this work may contribute to the development of high-performance array X-ray detectors based on Cs2AgBiBr6 perovskite material.