CMCurtis W. Meuse

Curtis W. Meuse

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Curtis W. Meuse has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Two-Dimensional Correlation of Quantum-Mechanical Infrared Spectra Reveals Order of Vibrational-Mode Positions and Predicts Classical RMSD Structural Descriptor

    by Robert J. Allsopp, Curtis W. Meuse

    Quantum mechanics (QM) provides the fundamental basis for an in silico (computational) analogue to infrared (IR) spectroscopy. Quantum-chemical vibrational analysis, as used here with the normal-mode approximation, provides an approximate description of molecular vibrations and yields calculated vibrational transition wavenumbers and infrared intensities for the normal modes of a given molecular conformation. One challenge in quantum normal-mode analysis is identifying structural or functional group relationships between modes of two different molecular conformations. Phospholipids, which are of supreme biomedical importance because they form cell membranes, are ideal-sized targets for density functional theory (DFT) scaling in quantum vibrational analysis. Hundreds of QM spectra can be readily simulated by using DFT, enabling comparisons of modes across many lipid conformations. In addition, lipids are long enough in the Z-dimension (perpendicular to the membrane) that the ordering of molecular functional groups based on Z-coordinate centers can help describe the lipid conformation. Snapshots from triplicate bilayer systems in a vacuum were collected in a library of phospholipid quantum-mechanical models. The library illustrates how two-dimensional correlation spectroscopy (2D-COS) can be applied to assign normal modes to local regions and develop a particular order of functional group positions (order-of-positions) of a phospholipid structure. A k-nearest-neighbor (KNN) approach is applied to relate normal-mode wavenumbers and normal-mode Z-dimension positions to find the modes that are most similar in different lipid conformations. This mode-to-mode mapping enables predictions of the atomic position RMSD for pairs of lipids. A separate application of KNN allows for comparisons of many lipids against a fixed reference point. This enables fine-tuning of the reference-point wavenumber and Z-count values to correlate to a given functional group. The reference-point-based KNN reveals a second spectrum-to-structure relationship that shows that quantum normal modes correlate with the actual positions of the functional groups.

  • Open Access

    Role of Domain–Domain Interactions on the Self-Association and Physical Stability of Monoclonal Antibodies: Effect of pH and Salt

    by Amy Y. Xu, Marco A. Blanco, Maria Monica Castellanos, Curtis W. Meuse, Kevin Mattison, Ioannis Karageorgos, Harold W. Hatch, Vincent K. Shen, Joseph E. Curtis

    Monoclonal antibodies (mAbs) make up a major class of biotherapeutics with a wide range of clinical applications. Their physical stability can be affected by various environmental factors. For instance, an acidic pH can be encountered during different stages of the mAb manufacturing process, including purification and storage. Therefore, understanding the behavior of flexible mAb molecules in acidic solution environments will benefit the development of stable mAb products. This study used small-angle X-ray scattering (SAXS) and complementary biophysical characterization techniques to investigate the conformational flexibility and protein-protein interactions (PPI) of a model mAb molecule under near-neutral and acidic conditions. The study also characterized the interactions between Fab and Fc fragments under the same buffer conditions to identify domain-domain interactions. The results suggest that solution pH significantly influences mAb flexibility and thus could help mAbs remain physically stable by maximizing local electrostatic repulsions when mAbs become crowded in solution. Under acidic buffer conditions, both Fab and Fc contribute to the repulsive PPI observed among the full mAb at a low ionic strength. However, as ionic strength increases, hydrophobic interactions lead to the self-association of Fc fragments and, subsequently, could affect the aggregation state of the mAb.


  • Spectral Similarity: Full-Wavelength Range Calibration of Circular Dichroism Spectroscopy

    by Curtis W. Meuse, Kenneth A. Rubinson

    Circular dichroism (CD) measurements help characterize optically active molecules and higher-order biomolecular structures. The harmonization of interlaboratory CD measurements requires minimizing measurement uncertainties and determinate errors. Most CD measurements utilize a single-wavelength intensity measurement at a spectral peak to calibrate the intensities of the ultraviolet wavelength range. However, such a single-wavelength calibration is inherently less precise than using the CD instrument's spectrum over the entire measured spectral range. A more thorough and informative calibration can be achieved by remapping the spectrum into what we call a spectral similarity plot. This process allows a straightforward, quantitative evaluation of the shape congruence between two spectra over the full spectral range. While preliminary analyses suggest spectral similarity plots can be utilized with a variety of different spectrometry methods, here we illustrate the process applied to circular dichroism. Spectral similarity plots are highly sensitive to deviations due to differences in concentration, pathlength, source and detector properties, circular polarization balance, as well as wavelength nonlinearities and shifts. Deviations in these properties can be quantitated by a linear least squares fit of the remapped data. The remapping enables protocols to correct spectra toward congruence between two spectra. The spectra similarity comparison provides an objective, unambiguous test of the CD instrument quality when, for example, compared to a carefully calibrated system as shown in the examples described in the text.


  • Circular Dichroism Spectral Similarity Plots to Extend Validation and Correction to All Measured Wavelengths

    by Curtis W. Meuse

    Interlaboratory comparisons of circular dichroism (CD) spectra are useful for developing confidence in the measurements associated with optically active molecules. These measurements also help define the higher-order (secondary and tertiary) structure of biopolymers. Unfortunately, the extent of the validity of these measurements has been unclear. In this work, a method is described to extend CD validation over the entire observed wavelength range using what will be called spectral similarity plots. The method involves plotting, wavelength by wavelength, all measured spectral intensities of a sample at one concentration against the intensity values of the same material at a different concentration or pathlength. These spectral similarity plots validate the instrument in terms of spectral shape and whether the shape is shifted in intensity and/or in wavelength. This comparison tests the linearity of instrument’s signal, the balance of its left and right polarizations, its wavelengths, and its spectral intensity scales. When the process is applied to materials with accepted and archived intensity values, the method can be linked to older single-wavelength and double-wavelength calibration techniques. Further, spectral similarity testing of CD spectra from samples with different concentrations run in different labs suggests that improved interlaboratory validation of CD data is possible. Since a database of archival CD measurements is available online, spectral similarity comparisons could possibly provide the ability to compare linearity, polarization balance, wavelength, and spectral intensity between all current CD instruments. If the preliminary results published here prove robust and transferable, then comparisons of full-wavelength range spectra to archived data using spectral similarity plots should become part of the standard process to validate and calibrate the performance of CD instruments.


  • Submultiple Data Collection to Explore Spectroscopic Instrument Instabilities Shows that Much of the “Noise” is not Stochastic

    by Curtis W. Meuse, James J. Filliben, Kenneth A. Rubinson

    As has long been understood, the noise on a spectrometric signal can be reduced by averaging over time, and the averaged noise is expected to decrease as t1/2, the square root of the data collection time. However, with contemporary capability for fast data collection and storage, we can retain and access a great deal more information about a signal train than just its average over time. During the same collection time, we can record the signal averaged over much shorter, equal, fixed periods. This is, then, the set of signals over submultiples of the total collection time. With a sufficiently large set of submultiples, the distribution of the signal’s fluctuations over the submultiple periods of the data stream can be acquired at each wavelength (or frequency). From the autocorrelations of submultiple sets, we find only some fraction of these fluctuations consist of stochastic noise. Part of the fluctuations are what we call “fast drift”, which is defined as drift over a time shorter than the complete measurement period of the average spectrum. In effect, what is usually assumed to be stochastic noise has a significant component of fast drift due to changes of conditions in the spectroscopic system. In addition, we show that the extreme values of the fluctuation of the signals are usually not balanced (equal magnitudes, equal probabilities) on either side of the mean or median without an inconveniently long measurement time; the data is almost inevitably biased. In other words, the unbalanced data is collected in an unbalanced manner around the mean, and so the median provides a better measure of the true spectrum. As is shown here, by using the medians of these distributions, the signal-to-noise of the spectrum can be increased and sampling bias reduced. The effect of this submultiple median data treatment is demonstrated for infrared, circular dichroism, and Raman spectrometry.


  • Quantitative Infrared Spectroscopy of Formalin-fixed, Paraffin-embedded Tissue Specimens

    by Curtis W. Meuse, Peter E. Barker

    Formalin-fixed, paraffin-embedded tissue specimens form the basis for diagnostic histopathology. Although adequate for morphologic visualization, clinical variability in preparation of formalin-fixed, paraffin-embedded clinical specimens represents an obstacle to quantitative molecular genetic analysis in areas such as genomics and proteomics. A quantitative reexamination of classical histopathology tissue preparation methods was initiated to determine which protocol steps might improve molecular analysis, beginning with deparaffinization. Infrared spectroscopy in the spectral region above 2000/cm of fixed sectioned model cell cultures through glass microscope slides showed all solvents remove over 97% of paraffin. To further compare extractions among solvents xylene, hexane and limonene, the correlation coefficients between the spectrum of paraffin and the spectra of the mounted extracted model tissue sections across the spectral interval containing the prominent CH stretching bands of paraffin were calculated. The correlation coefficients allow different extraction methods to be ranked in terms of how much paraffin remains. The results indicate that among 3 model tissue sample types, xylene extraction removes more paraffin than hexane or limonene. More importantly, these results establish a starting point from which further analysis of preanalytical processing methods can proceed.


  • Measuring hydrogen–deuterium exchange in protein monolayers

    by Jack R. Smith, Marcus T. Cicerone, Curtis W. Meuse

    A Fourier transform infrared (FTIR) spectroscopy assay to measure hydrogen–deuterium exchange (HDX) in surface‐adsorbed protein monolayers is developed to provide information on protein tertiary structure, because the typical secondary structural analysis of our surface and solution protein samples proved to be very similar. Adsorbed protein HDX is quantified by exposing the protein to a 50% deuterated NaPO 4 buffer solution and then measuring the normalized intensity change of the amide II band in the FTIR reflection spectrum. When collected as a function of exchange time, this intensity follows the kinetics of the exposure of the protein amides to solvent. HDX kinetics have been obtained for bovine serum albumin (BSA) in solution and adsorbed to gold surfaces. Using experiments designed to allow comparisons between protein in solution and on surfaces, the extent of HDX was found to increase over that observed for BSA in solution, consistent with an increase in the exposure of albumin amide groups and protein unfolding upon adsorption. We also show that BSA adsorbs to the surface of gold in multilayers and that the increase in amide exposure is present only in the first adsorbed monolayer. Published in 2009 by John Wiley & Sons, Ltd.