Felix Heilmeyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felix Heilmeyer has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Böhringer
Eye Center, University Hospital Freiburg, Freiburg, Germany
5 shared publications - Sebastian Arens
University of Freiburg
3 shared publications - Thomas Reinhard
Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
3 shared publications - Angelika Eisele-Metzger
Institute for Evidence in Medicine, Medical Center – University of Freiburg, Faculty of Medicine, University of Freiburg
2 shared publications - Anna Richling
Eye Center, University Medical Center Freiburg, Freiburg im Breisgau, Baden Wuerttemberg, Germany
2 shared publications Christian Haverkamp
Affiliation Institute for Digitalization in Medicine, University Medical Center Freiburg, Freiburg, Germany
2 shared publications
Latest Publications
- Open Access
- 23 July 2026
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 5 (7) , e0001461
Implementation outcomes of AI documentation support in routine clinical practice: A non-randomized controlled trial
While large language models (LLMs) show promise for reducing clinical documentation burden, existing studies rely on simulated environments or require supplemental audio inputs. This study evaluates an AI documentation copilot integrated into real-world electronic health record (EHR) workflows, measuring its impact on physician efficiency and documentation review burden. We conducted a non-randomized controlled trial with 27 ophthalmology clinicians over 12 months (January 2024-February 2025). Participants self-selected into intervention (n = 11) or control (n = 17) groups after a 4-month baseline. The AI system generated inline suggestions for discharge letter conclusions using only the patient’s EHR record as input. The system was based on a Quantized Low-Rank Adaptation (QLoRA) tuned LLM trained on 80,000 institutional records. Primary outcomes included words-per-minute (WPM) rates and the count of required document revisions after checks by the supervising senior physician across 15,615 documents. Intervention group clinicians achieved greater WPM improvements than controls ( Δ + 7.2 vs. Δ + 2.6 ), while revision frequency decreased within the intervention group (from 1.36 ± 0.14 to 1.26 ± 0.08 per document), with no significant change observed in the control group. Linear mixed-effects modeling confirmed a significant group × exposure interaction for documentation efficiency (p = 0.045), whereas no statistically significant interaction was observed for revision count. This real-world evaluation suggests that AI documentation assistance is associated with improved documentation efficiency under routine clinical conditions, while maintaining documentation standards under established supervision processes. These findings support the cooperative “copilot” design as a viable approach to enhance documentation efficiency without compromising patient safety protocols and indicate its potential to help reduce documentation burden in clinical practice.
- 23 July 2026
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 5 (7) , e0001461
Open AccessImplementation outcomes of AI documentation support in routine clinical practice: A non-randomized controlled trial
While large language models (LLMs) show promise for reducing clinical documentation burden, existing studies rely on simulated environments or require supplemental audio inputs. This study evaluates an AI documentation copilot integrated into real-world electronic health record (EHR) workflows, measuring its impact on physician efficiency and documentation review burden. We conducted a non-randomized controlled trial with 27 ophthalmology clinicians over 12 months (January 2024-February 2025). Participants self-selected into intervention (n = 11) or control (n = 17) groups after a 4-month baseline. The AI system generated inline suggestions for discharge letter conclusions using only the patient’s EHR record as input. The system was based on a Quantized Low-Rank Adaptation (QLoRA) tuned LLM trained on 80,000 institutional records. Primary outcomes included words-per-minute (WPM) rates and the count of required document revisions after checks by the supervising senior physician across 15,615 documents. Intervention group clinicians achieved greater WPM improvements than controls ( Δ + 7.2 vs. Δ + 2.6 ), while revision frequency decreased within the intervention group (from 1.36 ± 0.14 to 1.26 ± 0.08 per document), with no significant change observed in the control group. Linear mixed-effects modeling confirmed a significant group × exposure interaction for documentation efficiency (p = 0.045), whereas no statistically significant interaction was observed for revision count. This real-world evaluation suggests that AI documentation assistance is associated with improved documentation efficiency under routine clinical conditions, while maintaining documentation standards under established supervision processes. These findings support the cooperative “copilot” design as a viable approach to enhance documentation efficiency without compromising patient safety protocols and indicate its potential to help reduce documentation burden in clinical practice.
- Open Access
- 26 November 2025
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 14, e72894
Streamlining Ophthalmic Documentation With Anonymized, Fine-Tuned Language Models: Feasibility Study
Background: The growing administrative burden on clinicians, particularly in medical documentation, contributes to burnout and may compromise patient safety. Recent advancements in generative artificial intelligence (AI) offer a promising solution to improve documentation processes and address these challenges. Objective: This study aims to evaluate the feasibility of using a fine-tuned OpenAI Curie model to automate the generation of medical report summaries (epicrises) in ophthalmology. By assessing the model’s performance through human and automated evaluations, this study seeks to determine its potential for reducing clinician workload while ensuring accuracy, usefulness, and compliance with regulatory requirements. Methods: A data set of around 60,000 anonymized medical letters was created using a custom algorithm to comply with General Data Protection Regulation guidelines. The Curie model was fine-tuned on this data set to generate epicrises from medical histories, diagnoses, and findings. The performance evaluation involved various human assessments and automated evaluations from 2 large language models (LLMs). Results: In the clinical context, 49.9% (384/769) of epicrises were evaluated as helpful or excellent, whereas only 25% (194/769) were considered disturbing. In a human (manual) evaluation, formal correctness was rated significantly higher than the neutral midpoint of 2.5 on the 4-point rating scale, as determined by a 1-sample Wilcoxon signed-rank test (mean 3.59, SD 0.85; W=1686; P<.001). Using paired t tests, we found a significant reduction in time, as correcting an AI epicrisis was faster than manually writing one (mean 109.52, SD 53.30 vs mean 54.25, SD 63.34 s; t68=3.39; P<.01). While medical accuracy and usefulness showed positive trends, these did not reach statistical significance when compared to the neutral midpoint (for medical accuracy, W= 7456; P=.08), for usefulness, W=7652.5; P=.18). Epicrises generated or corrected with AI were significantly shorter than manually written ones (mean 330.43, SD 115.42 vs mean 501.07, SD 243.50 characters; t68=–6.10; P<.001). Automated LLM assessments showed alignment with human ratings, with over 52% (356/679) and 66% (489/743) of responses in the top agreement categories, respectively. This supports overall consistency, though the comparison remains a proof of concept given methodological limitations. Conclusions: Our study demonstrates the technical and practical feasibility of introducing fine-tuned commercial LLMs into clinical practice. The AI-generated epicrises were formally and clinically correct in many cases and showed time-saving potential. While medical accuracy and usefulness varied across cases and should be focused on in further developments, a significant workload reduction is likely. Our anonymization process showed that regulatory challenges in the context of AI with patient data can effectively be dealt with. In summary, this study highlights the promise of transformer-based LLMs in reducing administrative tasks in health care. It outlines a pipeline for integrating LLMs into European Union clinical practice, emphasizing the need for careful implementation to ensure efficiency and patient safety.
- 26 November 2025
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 14, e72894
Open AccessStreamlining Ophthalmic Documentation With Anonymized, Fine-Tuned Language Models: Feasibility Study
Background: The growing administrative burden on clinicians, particularly in medical documentation, contributes to burnout and may compromise patient safety. Recent advancements in generative artificial intelligence (AI) offer a promising solution to improve documentation processes and address these challenges. Objective: This study aims to evaluate the feasibility of using a fine-tuned OpenAI Curie model to automate the generation of medical report summaries (epicrises) in ophthalmology. By assessing the model’s performance through human and automated evaluations, this study seeks to determine its potential for reducing clinician workload while ensuring accuracy, usefulness, and compliance with regulatory requirements. Methods: A data set of around 60,000 anonymized medical letters was created using a custom algorithm to comply with General Data Protection Regulation guidelines. The Curie model was fine-tuned on this data set to generate epicrises from medical histories, diagnoses, and findings. The performance evaluation involved various human assessments and automated evaluations from 2 large language models (LLMs). Results: In the clinical context, 49.9% (384/769) of epicrises were evaluated as helpful or excellent, whereas only 25% (194/769) were considered disturbing. In a human (manual) evaluation, formal correctness was rated significantly higher than the neutral midpoint of 2.5 on the 4-point rating scale, as determined by a 1-sample Wilcoxon signed-rank test (mean 3.59, SD 0.85; W=1686; P<.001). Using paired t tests, we found a significant reduction in time, as correcting an AI epicrisis was faster than manually writing one (mean 109.52, SD 53.30 vs mean 54.25, SD 63.34 s; t68=3.39; P<.01). While medical accuracy and usefulness showed positive trends, these did not reach statistical significance when compared to the neutral midpoint (for medical accuracy, W= 7456; P=.08), for usefulness, W=7652.5; P=.18). Epicrises generated or corrected with AI were significantly shorter than manually written ones (mean 330.43, SD 115.42 vs mean 501.07, SD 243.50 characters; t68=–6.10; P<.001). Automated LLM assessments showed alignment with human ratings, with over 52% (356/679) and 66% (489/743) of responses in the top agreement categories, respectively. This supports overall consistency, though the comparison remains a proof of concept given methodological limitations. Conclusions: Our study demonstrates the technical and practical feasibility of introducing fine-tuned commercial LLMs into clinical practice. The AI-generated epicrises were formally and clinically correct in many cases and showed time-saving potential. While medical accuracy and usefulness varied across cases and should be focused on in further developments, a significant workload reduction is likely. Our anonymization process showed that regulatory challenges in the context of AI with patient data can effectively be dealt with. In summary, this study highlights the promise of transformer-based LLMs in reducing administrative tasks in health care. It outlines a pipeline for integrating LLMs into European Union clinical practice, emphasizing the need for careful implementation to ensure efficiency and patient safety.
- Open Access
- 21 February 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Streamlining Ophthalmic Documentation With Anonymized, Fine-Tuned Language Models: Feasibility Study (Preprint)
BACKGROUND The growing administrative burden on clinicians, particularly in medical documentation, contributes to burnout and may compromise patient safety. Recent advancements in generative artificial intelligence (AI) offer a promising solution to improve documentation processes and address these challenges. OBJECTIVE This study aims to evaluate the feasibility of using a fine-tuned OpenAI Curie model to automate the generation of medical report summaries (epicrises) in ophthalmology. By assessing the model’s performance through human and automated evaluations, this study seeks to determine its potential for reducing clinician workload while ensuring accuracy, usefulness, and compliance with regulatory requirements. METHODS A data set of around 60,000 anonymized medical letters was created using a custom algorithm to comply with General Data Protection Regulation guidelines. The Curie model was fine-tuned on this data set to generate epicrises from medical histories, diagnoses, and findings. The performance evaluation involved various human assessments and automated evaluations from 2 large language models (LLMs). RESULTS In the clinical context, 49.9% (384/769) of epicrises were evaluated as helpful or excellent, whereas only 25% (194/769) were considered disturbing. In a human (manual) evaluation, formal correctness was rated significantly higher than the neutral midpoint of 2.5 on the 4-point rating scale, as determined by a 1-sample Wilcoxon signed-rank test (mean 3.59, SD 0.85; W=1686; P<.001). Using paired t tests, we found a significant reduction in time, as correcting an AI epicrisis was faster than manually writing one (mean 109.52, SD 53.30 vs mean 54.25, SD 63.34 s; t68=3.39; P<.01). While medical accuracy and usefulness showed positive trends, these did not reach statistical significance when compared to the neutral midpoint (for medical accuracy, W= 7456; P=.08), for usefulness, W=7652.5; P=.18). Epicrises generated or corrected with AI were significantly shorter than manually written ones (mean 330.43, SD 115.42 vs mean 501.07, SD 243.50 characters; t68=–6.10; P<.001). Automated LLM assessments showed alignment with human ratings, with over 52% (356/679) and 66% (489/743) of responses in the top agreement categories, respectively. This supports overall consistency, though the comparison remains a proof of concept given methodological limitations. CONCLUSIONS Our study demonstrates the technical and practical feasibility of introducing fine-tuned commercial LLMs into clinical practice. The AI-generated epicrises were formally and clinically correct in many cases and showed time-saving potential. While medical accuracy and usefulness varied across cases and should be focused on in further developments, a significant workload reduction is likely. Our anonymization process showed that regulatory challenges in the context of AI with patient data can effectively be dealt with. In summary, this study highlights the promise of transformer-based LLMs in reducing administrative tasks in health care. It outlines a pipeline for integrating LLMs into European Union clinical practice, emphasizing the need for careful implementation to ensure efficiency and patient safety.
- 21 February 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessStreamlining Ophthalmic Documentation With Anonymized, Fine-Tuned Language Models: Feasibility Study (Preprint)
BACKGROUND The growing administrative burden on clinicians, particularly in medical documentation, contributes to burnout and may compromise patient safety. Recent advancements in generative artificial intelligence (AI) offer a promising solution to improve documentation processes and address these challenges. OBJECTIVE This study aims to evaluate the feasibility of using a fine-tuned OpenAI Curie model to automate the generation of medical report summaries (epicrises) in ophthalmology. By assessing the model’s performance through human and automated evaluations, this study seeks to determine its potential for reducing clinician workload while ensuring accuracy, usefulness, and compliance with regulatory requirements. METHODS A data set of around 60,000 anonymized medical letters was created using a custom algorithm to comply with General Data Protection Regulation guidelines. The Curie model was fine-tuned on this data set to generate epicrises from medical histories, diagnoses, and findings. The performance evaluation involved various human assessments and automated evaluations from 2 large language models (LLMs). RESULTS In the clinical context, 49.9% (384/769) of epicrises were evaluated as helpful or excellent, whereas only 25% (194/769) were considered disturbing. In a human (manual) evaluation, formal correctness was rated significantly higher than the neutral midpoint of 2.5 on the 4-point rating scale, as determined by a 1-sample Wilcoxon signed-rank test (mean 3.59, SD 0.85; W=1686; P<.001). Using paired t tests, we found a significant reduction in time, as correcting an AI epicrisis was faster than manually writing one (mean 109.52, SD 53.30 vs mean 54.25, SD 63.34 s; t68=3.39; P<.01). While medical accuracy and usefulness showed positive trends, these did not reach statistical significance when compared to the neutral midpoint (for medical accuracy, W= 7456; P=.08), for usefulness, W=7652.5; P=.18). Epicrises generated or corrected with AI were significantly shorter than manually written ones (mean 330.43, SD 115.42 vs mean 501.07, SD 243.50 characters; t68=–6.10; P<.001). Automated LLM assessments showed alignment with human ratings, with over 52% (356/679) and 66% (489/743) of responses in the top agreement categories, respectively. This supports overall consistency, though the comparison remains a proof of concept given methodological limitations. CONCLUSIONS Our study demonstrates the technical and practical feasibility of introducing fine-tuned commercial LLMs into clinical practice. The AI-generated epicrises were formally and clinically correct in many cases and showed time-saving potential. While medical accuracy and usefulness varied across cases and should be focused on in further developments, a significant workload reduction is likely. Our anonymization process showed that regulatory challenges in the context of AI with patient data can effectively be dealt with. In summary, this study highlights the promise of transformer-based LLMs in reducing administrative tasks in health care. It outlines a pipeline for integrating LLMs into European Union clinical practice, emphasizing the need for careful implementation to ensure efficiency and patient safety.
- Open Access
Large language models for conducting systematic reviews: on the rise, but not yet ready for use – a scoping review
Background Machine learning (ML) promises versatile help in the creation of systematic reviews (SRs). Recently, further developments in the form of large language models (LLMs) and their application in SR conduct attracted attention. Objective To provide an overview of ML and specifically LLM applications in SR conduct in health research. Study design We systematically searched MEDLINE, Web of Science, IEEEXplore, ACM Digital Library, Europe PMC (preprints), Google Scholar, and conducted an additional hand search (last search: 26 February 2024). We included scientific articles in English or German, published from April 2021 onwards, building upon the results of a mapping review with a related research question. Two reviewers independently screened studies for eligibility; after piloting, one reviewer extracted data, checked by another. Results Our database search yielded 8054 hits, and we identified 33 articles from our hand search. Of the 196 included reports, 159 described more traditional ML techniques, 37 focused on LLMs. LLM approaches covered 10 of 13 defined SR steps, most frequently literature search (n=15, 41%), study selection (n=14, 38%), and data extraction (n=11, 30%). The mostly recurring LLM was GPT (n=33, 89%). Validation studies were predominant (n=21, 57%). In half of the studies, authors evaluated LLM use as promising (n=20, 54%), one quarter as neutral (n=9, 24%) and one fifth as non-promising (n=8, 22%). Conclusions Although LLMs show promise in supporting SR creation, fully established or validated applications are often lacking. The rapid increase in research on LLMs for evidence synthesis production highlights their growing relevance. HIGHLIGHTS Machine learning (ML) offers promising support for systematic review (SR) creation. GPT was the most commonly used large language model (LLM) to support SR production. LLM application included 10 of 13 defined SR steps, most often literature search. Validation studies predominated, but fully established LLM applications are rare. LLM research for SR conduct is surging, highlighting the increasing relevance.
Open AccessLarge language models for conducting systematic reviews: on the rise, but not yet ready for use – a scoping review
Background Machine learning (ML) promises versatile help in the creation of systematic reviews (SRs). Recently, further developments in the form of large language models (LLMs) and their application in SR conduct attracted attention. Objective To provide an overview of ML and specifically LLM applications in SR conduct in health research. Study design We systematically searched MEDLINE, Web of Science, IEEEXplore, ACM Digital Library, Europe PMC (preprints), Google Scholar, and conducted an additional hand search (last search: 26 February 2024). We included scientific articles in English or German, published from April 2021 onwards, building upon the results of a mapping review with a related research question. Two reviewers independently screened studies for eligibility; after piloting, one reviewer extracted data, checked by another. Results Our database search yielded 8054 hits, and we identified 33 articles from our hand search. Of the 196 included reports, 159 described more traditional ML techniques, 37 focused on LLMs. LLM approaches covered 10 of 13 defined SR steps, most frequently literature search (n=15, 41%), study selection (n=14, 38%), and data extraction (n=11, 30%). The mostly recurring LLM was GPT (n=33, 89%). Validation studies were predominant (n=21, 57%). In half of the studies, authors evaluated LLM use as promising (n=20, 54%), one quarter as neutral (n=9, 24%) and one fifth as non-promising (n=8, 22%). Conclusions Although LLMs show promise in supporting SR creation, fully established or validated applications are often lacking. The rapid increase in research on LLMs for evidence synthesis production highlights their growing relevance. HIGHLIGHTS Machine learning (ML) offers promising support for systematic review (SR) creation. GPT was the most commonly used large language model (LLM) to support SR production. LLM application included 10 of 13 defined SR steps, most often literature search. Validation studies predominated, but fully established LLM applications are rare. LLM research for SR conduct is surging, highlighting the increasing relevance.
- Top Cited PapersOpen Access
- 28 August 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 12, e59617
Viability of Open Large Language Models for Clinical Documentation in German Health Care: Real-World Model Evaluation Study
Background: The use of large language models (LLMs) as writing assistance for medical professionals is a promising approach to reduce the time required for documentation, but there may be practical, ethical, and legal challenges in many jurisdictions complicating the use of the most powerful commercial LLM solutions. Objective: In this study, we assessed the feasibility of using nonproprietary LLMs of the GPT variety as writing assistance for medical professionals in an on-premise setting with restricted compute resources, generating German medical text. Methods: We trained four 7-billion–parameter models with 3 different architectures for our task and evaluated their performance using a powerful commercial LLM, namely Anthropic’s Claude-v2, as a rater. Based on this, we selected the best-performing model and evaluated its practical usability with 2 independent human raters on real-world data. Results: In the automated evaluation with Claude-v2, BLOOM-CLP-German, a model trained from scratch on the German text, achieved the best results. In the manual evaluation by human experts, 95 (93.1%) of the 102 reports generated by that model were evaluated as usable as is or with only minor changes by both human raters. Conclusions: The results show that even with restricted compute resources, it is possible to generate medical texts that are suitable for documentation in routine clinical practice. However, the target language should be considered in the model selection when processing non-English text.
- 28 August 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 12, e59617
Top Cited PapersOpen AccessViability of Open Large Language Models for Clinical Documentation in German Health Care: Real-World Model Evaluation Study
Background: The use of large language models (LLMs) as writing assistance for medical professionals is a promising approach to reduce the time required for documentation, but there may be practical, ethical, and legal challenges in many jurisdictions complicating the use of the most powerful commercial LLM solutions. Objective: In this study, we assessed the feasibility of using nonproprietary LLMs of the GPT variety as writing assistance for medical professionals in an on-premise setting with restricted compute resources, generating German medical text. Methods: We trained four 7-billion–parameter models with 3 different architectures for our task and evaluated their performance using a powerful commercial LLM, namely Anthropic’s Claude-v2, as a rater. Based on this, we selected the best-performing model and evaluated its practical usability with 2 independent human raters on real-world data. Results: In the automated evaluation with Claude-v2, BLOOM-CLP-German, a model trained from scratch on the German text, achieved the best results. In the manual evaluation by human experts, 95 (93.1%) of the 102 reports generated by that model were evaluated as usable as is or with only minor changes by both human raters. Conclusions: The results show that even with restricted compute resources, it is possible to generate medical texts that are suitable for documentation in routine clinical practice. However, the target language should be considered in the model selection when processing non-English text.
- Open Access
Exploring the potential of Claude 2 for risk of bias assessment: Using a large language model to assess randomized controlled trials with RoB 2
Systematic reviews are essential for evidence based healthcare, but conducting them is time and resource consuming. To date, efforts have been made to accelerate and (semi-) automate various steps of systematic reviews through the use of artificial intelligence and the emergence of large language models (LLMs) promises further opportunities. One crucial but complex task within systematic review conduct is assessing the risk of bias of included studies. Therefore, the aim of this study was to test the LLM Claude 2 for risk of bias assessment of 100 randomized controlled trials using the revised Cochrane risk of bias tool (“RoB 2”; involving judgements for five specific domains and an overall judgement). We assessed the agreement of risk of bias judgements by Claude with human judgements published in Cochrane Reviews. The observed agreement between Claude and Cochrane authors ranged from 41% for the overall judgement to 71% for domain 4 (“outcome measurement”). Cohen’s κ was lowest for domain 5 (“selective reporting”; 0.10 (95% confidence interval (CI): −0.10-0.31)) and highest for domain 3 (“missing data”; 0.31 (95% CI: 0.10-0.52)), indicating slight to fair agreement. Fair agreement was found for the overall judgement (Cohen’s κ: 0.22 (95% CI: 0.06-0.38)). Sensitivity analyses using alternative prompting techniques or the more recent version Claude 3 did not result in substantial changes. Currently, Claude’s RoB 2 judgements cannot replace human risk of bias assessment. However, the potential of LLMs to support risk of bias assessment should be further explored.
Open AccessExploring the potential of Claude 2 for risk of bias assessment: Using a large language model to assess randomized controlled trials with RoB 2
Systematic reviews are essential for evidence based healthcare, but conducting them is time and resource consuming. To date, efforts have been made to accelerate and (semi-) automate various steps of systematic reviews through the use of artificial intelligence and the emergence of large language models (LLMs) promises further opportunities. One crucial but complex task within systematic review conduct is assessing the risk of bias of included studies. Therefore, the aim of this study was to test the LLM Claude 2 for risk of bias assessment of 100 randomized controlled trials using the revised Cochrane risk of bias tool (“RoB 2”; involving judgements for five specific domains and an overall judgement). We assessed the agreement of risk of bias judgements by Claude with human judgements published in Cochrane Reviews. The observed agreement between Claude and Cochrane authors ranged from 41% for the overall judgement to 71% for domain 4 (“outcome measurement”). Cohen’s κ was lowest for domain 5 (“selective reporting”; 0.10 (95% confidence interval (CI): −0.10-0.31)) and highest for domain 3 (“missing data”; 0.31 (95% CI: 0.10-0.52)), indicating slight to fair agreement. Fair agreement was found for the overall judgement (Cohen’s κ: 0.22 (95% CI: 0.06-0.38)). Sensitivity analyses using alternative prompting techniques or the more recent version Claude 3 did not result in substantial changes. Currently, Claude’s RoB 2 judgements cannot replace human risk of bias assessment. However, the potential of LLMs to support risk of bias assessment should be further explored.
- Open Access
- 1 October 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (42) , 1626
neurone_loader: A Python module for loading EEG data recorded with Bittium NeurOne
- 1 October 2019
- Published by The Open Journal in Journal of Open Source Software
- Vol. 4 (42) , 1626
Open Accessneurone_loader: A Python module for loading EEG data recorded with Bittium NeurOne