HNHiroyuki Nakajima

Hiroyuki Nakajima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroyuki Nakajima has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Junjiro Kobayashi

    Department of Cardiovascular Surgery , National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565 , Japan

    13 shared publications
  • Soichiro Kitamura

    Department of Cardiovascular Surgery , National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565 , Japan

    10 shared publications
  • Kazuo Niwaya

    Department of Cardiovascular Surgery, National Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565, Japan

    6 shared publications
  • Osamu Tagusari

    Department of Cardiovascular Surgery, National Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565, Japan

    6 shared publications
  • Ko Bando

    4 shared publications
  • Toshikatsu Yagihara

    4 shared publications

Latest Publications

  • Open Access

    Determinants for successful sequential radial artery grafting to the left circumflex and right coronary arteries

    by Hiroyuki Nakajima, Junjiro Kobayashi, Koichi Toda, Tomoyuki Fujita, Yusuke Shimahara, Yoichiro Kasahara, Soichiro Kitamura

    The aim of this retrospective observational study was to delineate determinants for antegrade flow and entire patency of the sequential radial artery


  • A 10-year angiographic follow-up of competitive flow in sequential and composite arterial grafts☆

    by Hiroyuki Nakajima, Junjiro Kobayashi, Koji Toda, Tomoyuki Fujita, Yusuke Shimahara, Yoichiro Kasahara, Soichiro Kitamura

    Physiological reaction to competitive flow is considered as the primary mechanism of arterial graft occlusion. Reopening of graft lumen had been also reported, but details remain unknown. We sought to delineate the effect of management of the moderately stenotic targets on the occurrence of competitive flow and clinical results. Clinical records and angiograms of 3263 bypass grafts in 852 patients, who underwent off-pump coronary revascularization using the internal thoracic artery (ITA) and radial artery without aortic manipulation since 2000, were examined. Dominant flow direction was graded as antegrade, competitive, and no flow (occlusion). Late angiography was performed in 157 patients with 561 bypass grafts for clinical reasons. The follow-up period was 55.5 ± 31.1 months. The early graft patency rate was 98.0% (3197/3263). The rate of antegrade flow was 91.5% (2986/3263), while competitive flow was detected in 6.5% (211/3263). The actuarial patency rates of bypass grafts with antegrade flow were significantly higher than those with competitive flow (87.9% at 5 years and 71.3% at 8 years, vs 25.8% at 5 years and 9.2% at 8 years, p<0.0001). In the univariate and multivariate analyses for 852 patients, territory of right coronary artery (odds ratio (OR)=2.20, p=0.0002), composite radial artery (OR=1.90, p=0.03), and the distal end of the graft (OR=2.90, p=0.0003), were identified as the significant predictors of competitive flow from the target with 51-75% stenosis. Individual grafting inversely correlated with occurrence of competitive flow (OR=0.48, p=0.04). Reopening of the graft lumen associated with progression of native stenosis was not observed in these patients. Competitive flow can be efficiently avoided by appropriate graft arrangement and patients' selection. Selection of the target of the graft end would be crucial to achieve antegrade bypass flow and long-term patency of entire sequential bypass grafts. For the composite graft, functional recovery of the occluded graft would be extremely rare.


  • Safety and efficacy of sequential and composite arterial grafting to more than five coronary branches in off-pump coronary revascularisation: assessment of intra-operative and angiographic bypass flow

    by Hiroyuki Nakajima, Junjiro Kobayashi, Koichi Toda, Tomoyuki Fujita, Yutaka Iba, Yusuke Shimahara, Shunsuke Sato, Soichiro Kitamura

    We sought to delineate the safety and efficacy of sequential and composite coronary artery bypass grafting (CABG) with exclusively arterial grafts to more than five coronary branches including small coronary vessels. We reviewed the clinical records of 633 consecutive patients with 2617 bypass grafts who underwent total arterial off-pump complete revascularisation for three-vessel coronary regions without aortic manipulation. Group I consisted of 263 patients with a single in situ internal thoracic artery (ITA), while group II consisted of 370 patients with bilateral in situ ITA. Subgroups I-A and I-B consisted of 242 patients with three or four distal anastomoses and 21 patients with more than five distal anastomoses, respectively. Subgroups II-A and II-B consisted of 199 patients with three or four anastomoses and 171 patients with more than five anastomoses, respectively. The early mortality and morbidity rate and the angiographic graft patency in the groups I and II were similar, while the rate of antegrade flow in group II (92.4%, 1349/1460) was significantly higher than that in group I (89.4%, 638/714, p=0.02). Intra-operative graft flow measured at the proximal portion of the in situ ITA in group II (79+/-35 ml min(-1)) was significantly larger that that in group I (53+/-31 ml min(-1), p<0.0001). The patency rate of bypass grafts to small coronary vessels (1.25 mm or less in diameter) was 97.4% (626/643). The early mortality rates in subgroups I-A and I-B were 1.2% (3/242) and 0% (0/21), respectively (p=0.61). The graft flow and incidence of competitive flow was comparable in subgroups I-A and I-B. The early mortality rates in subgroups II-A and II-B were 0.5% (1/199) and 0.6% (1/177), respectively (p=0.91). The graft flow to five or more coronary branches (81+/-35 ml min(-1)) was significantly greater than that to three branches (67+/-30 ml min(-1), p=0.01). For more than five target branches, sequential and composite arterial grafting with the ITA and a radial artery was safe and reliable, even when the target vessels were small. Bilateral in situ ITA would be feasible for the patients with multiple stenotic lesions, because of abundant bypass flow and less incidence of competitive flow. Durable completeness of revascularisation can be expected.


  • Open Access

    Reply to Maros

    by Masashi Kawamura, Hiroyuki Nakajima, Junjiro Kobayashi

    Most of previous studies about FFR focused on management of the intermediate stenosis, not on predicting shortage of flow capacity of the ITA graft, nor necessi

  • Predictive factors for the intermediate-term patency of arterial grafts in aorta no-touch off-pump coronary revascularization

    by Hiroyuki Nakajima, Junjiro Kobayashi, Toshihiro Funatsu, Yusuke Shimahara, Masashi Kawamura, Atsushi Kawamura, Toshikatsu Yagihara, Soichiro Kitamura

    Graft flow is one of the important determinants of the arterial graft patency. To establish the optimal graft design, we examined detailed characteristics of the arterial composite and sequential grafts, and sought to delineate the risk factors of graft occlusion due to insufficient bypass flow. Angiograms of 2547 bypass grafts in 677 consecutive patients who underwent total arterial off-pump CABG without aortic manipulation followed by early postoperative angiography since December 2000 were reviewed. The angiographic flow was graded as A (antegrade), B (competitive), C (reversal), and O (occlusion). The overall early graft patency rate was 98.2% (2502/2547). The rate of grade A was 91.3% (2325/2547), while the rates of grades B and C were 2.9% (73/2547) and 4.1% (104/2547), respectively. For the main trunk of the anterior descending branch (LAD), the graft patency rate was 99.3% (674/679). The grade A rate of the internal thoracic artery (ITA) grafts to LAD in an individual fashion was 99.5% (203/204), being comparable with that in the sequential or composite grafting which had two distal anastomoses (98.1%, 159/162; p=0.33). The actuarial patency rates at 3 years were 84.7% for the bypass grafts with grade A flow and 33.9% for those with grade B/C flow, respectively (p<0.0001). The multivariate Cox-regression analysis demonstrated that grade B/C (p<0.0001, HR=4.19) and 51-75% stenosis of the native coronary artery (p=0.02, HR=2.86) were significant predictors of graft occlusion. For the LAD, the results of graft flow in sequential ITA grafting or composite grafting with two distal anastomoses were comparable with that in individual ITA grafting. Prediction and prevention of competitive and reverse flow are mandatory for achieving the advantages of the arterial materials.


  • Open Access

    A primary angiosarcoma in the aorta

    by Hiroyuki Nakajima, Junjiro Kobayashi, Hitoshi Matsuda, Hatsue Ishibashi-Ueda

    A 60-year-old woman after aortic valve replacement had an acute abdominal pain. Computed tomography demonstrated a tumor in the aorta, which originated from the distal portion of the thoracic aorta and extended to the aortic bifurcation. At autopsy, the orifices of celiac, superior and inferior mesenteric, right and left renal arteries were consistently occluded by incursion of the tumor. We present herein a huge primary sarcoma in the abdominal aorta, which has been reported as extremely rare.


  • Open Access

    Graft design strategies with optimum antegrade bypass flow in total arterial off-pump coronary artery bypass

    by Hiroyuki Nakajima, Junjiro Kobayashi, Osamu Tagusari, Kazuo Niwaya, Toshihiro Funatsu, Alaa Brik, Toshikatsu Yagihara, Soichiro Kitamura

    Objective: In arterial conduits, graft flow is one of the major determinants of long-term patency. We sought to delineate the effect of strategy for graft arrangement and design to three-vessel disease by evaluation of the dominant flow direction in each segment of a bypass graft. Materials and methods: We reviewed coronary angiograms of 1571 bypass grafts in 395 patients who underwent total arterial off-pump coronary revascularization without aortic manipulation for three-vessel disease since December 2000. The graft flow graded as A (antegrade), B (competitive), C (reverse), and O (no flow = occlusion). The current arrangement and design has been introduced since March 2003, and consists of the in-situ left internal thoracic artery (ITA) to the anterior descending artery and the composite I-graft of the right ITA and radial artery to the left circumflex (LCX) and right coronary artery (RCA) territories. Either clockwise or counterclockwise orientation, the I-graft was chosen to achieve a sufficient antegrade flow. Group I consisted of 181 patients with a single in-situ ITA as a composite Y-graft. Group II consisted of 214 patients with bilateral in-situ ITAs, which subdivided into Subgroup II-A consisted of 80 patients with bilateral in-situ ITAs until February 2003, and Subgroup II-B consisted of 134 patients with bilateral in-situ ITAs since March 2003. Results: The number of distal anastomoses was 3.52 ± 0.63 in Group I, and 4.36 ± 0.83 in Group II, respectively (p ≪ 0.0001). The overall graft patency rate was 98.6% (1549/1571), and there was no significance different between the groups. The rate of grade A in Group II was 863/933 (92.5%) and was significantly higher (p = 0.049) than that of Group I 572/638 (89.7%). The rate of functioning bypass in Subgroup II-B was (95.8%) 568/593, and was significantly higher (p = 0.03) than that in Subgroup II-A (92.4%) 314/340. In Subgroup II-B, 233/268 (86.9%) of the conduits had completely grade A bypass flow, and this ratio was significantly higher (p = 0.04) than that in Subgroup II-A (79.4%) 127/160. Conclusion: Usage of bilateral ITAs and selecting the orientation of the I-graft to LCX and RCA branches provide maximal distal anastomotic sites with satisfactory graft patency rate, and simultaneously minimized the incidence of reverse and competitive flow.


  • Angiographic flow grading and graft arrangement of arterial conduits

    by Hiroyuki Nakajima, Junjiro Kobayashi, Osamu Tagusari, Kazuo Niwaya, Toshihiro Funatsu, Atsushi Kawamura, Toshikatsu Yagihara, Soichiro Kitamura


  • Functional Angiographic Evaluation of Individual, Sequential, and Composite Arterial Grafts

    by Hiroyuki Nakajima, Junjiro Kobayashi, Osamu Tagusari, Ko Bando, Kazuo Niwaya, Soichiro Kitamura


  • Coronary Embolism and Subsequent Myocardial Abscess Complicating Ventricular Aneurysm and Tachycardia

    by Iki Adachi, Junjiro Kobayashi, Hiroyuki Nakajima, Kazuo Niwaya, Hatsue Ishibashi-Ueda, Ko Bando, Osamu Tagusari