Amer Aziz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amer Aziz has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
- Uruj Zehra
Department of Anatomy University of Health Sciences Lahore Pakistan
4 shared publications Muhammad Saad Ilyas
Department of Orthopedics and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan
2 shared publications- Shanmuganathan Rajasekaran
Department of Spine Surgery, Ganga Medical Centre and Hospitals Pvt. Ltd, Coimbatore, India
2 shared publications Abdul Sattar
Department of Orthopedics and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan
1 shared publication- Abdullah Al Mamun Choudhury
National Institute of Traumatology and Orthopaedic Rehabilitation, Dhaka, Bangladesh
1 shared publication - Abdullah Shah
Department of Orthopedics and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Punjab, Pakistan
1 shared publication
Latest Publications
- Open Access
- 31 August 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (4) , 522-531
Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Study Design: A 2-year follow-up study.Purpose: To evaluate the effectiveness of modified halo-pelvic Ilizarov distraction assembly in the management of patients with severe kyphoscoliosis.Overview of Literature: Severe and rigid scoliosis curves are always a challenge for operating surgeons. Preoperative correction through halo-pelvic devices successfully minimizes the severity of the curve; however, cumbersome complications are also reported with its use. Modified assembly could be safe for these cases.Methods: Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.Results: Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).Conclusions: Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
- 31 August 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (4) , 522-531
Open AccessEffectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis
Study Design: A 2-year follow-up study.Purpose: To evaluate the effectiveness of modified halo-pelvic Ilizarov distraction assembly in the management of patients with severe kyphoscoliosis.Overview of Literature: Severe and rigid scoliosis curves are always a challenge for operating surgeons. Preoperative correction through halo-pelvic devices successfully minimizes the severity of the curve; however, cumbersome complications are also reported with its use. Modified assembly could be safe for these cases.Methods: Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2–3 mm/day for 6–12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.Results: Thirty-four patients (age, 9–27 years; male/female ratio of 18:16) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).Conclusions: Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.
- 18 January 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (1) , e245824
Management of femoral shaft infected nonunion through customised Ilizarov external fixator assembly in a morbidly obese patient
A 19-year-old morbidly obese man presented with infected nonunion of femoral shaft fracture. Patient had history of 13 failed fixation surgeries, assessment revealed 3-centimetre limb-length discrepancy with 3-centimetre gap nonunion. Wound debridement, primary compression and external fixation using a customised Ilizarov external fixation assembly were planned. A four-ring customised assembly was applied. Partial weight bearing was allowed from first postoperative day on walker. Patient was kept on a monthly follow-up. After complete union at 10 months after surgery, frame was dynamised. After 6 months of dynamisation, frame was removed, at that time patient was full weight bearing. Knee was still stiff with a range of motion of 0°–20°, and there was 6 cm of limb length discrepancy, which was managed with a shoe raise. At 9 months after frame removal, patient is mobile with fully united bone. Ilizarov external fixator can be a good managing option in such difficult and complicated cases.
- 18 January 2022
- Published by BMJ in BMJ Case Reports
- Vol. 15 (1) , e245824
Management of femoral shaft infected nonunion through customised Ilizarov external fixator assembly in a morbidly obese patient
A 19-year-old morbidly obese man presented with infected nonunion of femoral shaft fracture. Patient had history of 13 failed fixation surgeries, assessment revealed 3-centimetre limb-length discrepancy with 3-centimetre gap nonunion. Wound debridement, primary compression and external fixation using a customised Ilizarov external fixation assembly were planned. A four-ring customised assembly was applied. Partial weight bearing was allowed from first postoperative day on walker. Patient was kept on a monthly follow-up. After complete union at 10 months after surgery, frame was dynamised. After 6 months of dynamisation, frame was removed, at that time patient was full weight bearing. Knee was still stiff with a range of motion of 0°–20°, and there was 6 cm of limb length discrepancy, which was managed with a shoe raise. At 9 months after frame removal, patient is mobile with fully united bone. Ilizarov external fixator can be a good managing option in such difficult and complicated cases.
- Open Access
- 14 June 2021
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 12, 290
Preoperative management through modified halo-pelvic distraction assembly in a case of severe thoracic spine kyphosis
Background: Halo-traction device has been seen with favorable outcome in managing the patients with severe kyphotic deformities preoperatively, however, associated complications are inevitable. Slight modifications can improve the outcome and clinical efficacy. Case Description: A 14-year-old boy was presented with severe kyphotic deformity of 141° from T1 to T10 thoracic vertebrae with diffuse paraspinal calcification in thoracic spine and complete loss of power of both lower limbs. A modified halo-pelvic distraction device was applied before the definitive surgery. The device comprised halo and pelvic assembly, the halo ring was connected to the head with 06 pins, while pelvic assembly had Ilizarov half pins connected to the arches. The assembly construct had four threaded rods, two of them were placed anterolateral and the other two were posterolateral. Distraction at the rate of 3 mm/day was started from 1st postoperative day for 35 days. The neurology improved in both lower limbs and kyphotic angle reduced to 56° from 141°. Surgery at this stage was done and a standalone solid titanium cage was placed from T1 to T10 vertebral body after debridement. No peri- or post-operative complications were observed. Conclusion: The application of halo-pelvic distraction before corrective surgeries can not only reduce the severity of the kyphotic deformity making the definitive surgery easy but neurology can also be improved. The high-risk complications associated with acute correction of deformities can be minimized using our modified halo-pelvic distraction device.
- 14 June 2021
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 12, 290
Open AccessPreoperative management through modified halo-pelvic distraction assembly in a case of severe thoracic spine kyphosis
Background: Halo-traction device has been seen with favorable outcome in managing the patients with severe kyphotic deformities preoperatively, however, associated complications are inevitable. Slight modifications can improve the outcome and clinical efficacy. Case Description: A 14-year-old boy was presented with severe kyphotic deformity of 141° from T1 to T10 thoracic vertebrae with diffuse paraspinal calcification in thoracic spine and complete loss of power of both lower limbs. A modified halo-pelvic distraction device was applied before the definitive surgery. The device comprised halo and pelvic assembly, the halo ring was connected to the head with 06 pins, while pelvic assembly had Ilizarov half pins connected to the arches. The assembly construct had four threaded rods, two of them were placed anterolateral and the other two were posterolateral. Distraction at the rate of 3 mm/day was started from 1st postoperative day for 35 days. The neurology improved in both lower limbs and kyphotic angle reduced to 56° from 141°. Surgery at this stage was done and a standalone solid titanium cage was placed from T1 to T10 vertebral body after debridement. No peri- or post-operative complications were observed. Conclusion: The application of halo-pelvic distraction before corrective surgeries can not only reduce the severity of the kyphotic deformity making the definitive surgery easy but neurology can also be improved. The high-risk complications associated with acute correction of deformities can be minimized using our modified halo-pelvic distraction device.
- 9 June 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (6) , e240195
Malunited and malrotated Salter-Harris type I fracture of distal femur managed with circular ring external Ilizarov fixator
A 9-year-old girl presented with malunited Salter-Harris type I fracture of distal femur treated by bone-setter (unreliable-practitioner). Assessment revealed 3 cm limb-length-discrepancy and affected leg was unable to bear weight, knee was stiff with no active-range of motion; radiographs showed displaced sagittally malunited femoral condyle with 163° posterior distal femoral angle (PDFA). Correction planned with circular-ring-external Ilizarov fixator using distraction-osteogenesis through supracondylar osteotomy and gradual anterior opening. Partial weight bearing allowed from first postoperative day on walker. Eight weeks follow-up showed restored anatomical position of femoral condyle and PDFA. During anterior-distraction and angulation correction, tibia subluxated posteriorly, for that assembly extended to tibia which gradually translated tibia anteriorly and reduced knee. Twenty weeks after removal of assembly patient was advised knee-ankle-foot-orthosis. At 40 weeks of frame removal, patient was walking without support and pain. Managing such rare injuries with distraction-osteogenesis technique allows gradual correction and monitoring, till desirable degree of correction is achieved.
- 9 June 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (6) , e240195
Malunited and malrotated Salter-Harris type I fracture of distal femur managed with circular ring external Ilizarov fixator
A 9-year-old girl presented with malunited Salter-Harris type I fracture of distal femur treated by bone-setter (unreliable-practitioner). Assessment revealed 3 cm limb-length-discrepancy and affected leg was unable to bear weight, knee was stiff with no active-range of motion; radiographs showed displaced sagittally malunited femoral condyle with 163° posterior distal femoral angle (PDFA). Correction planned with circular-ring-external Ilizarov fixator using distraction-osteogenesis through supracondylar osteotomy and gradual anterior opening. Partial weight bearing allowed from first postoperative day on walker. Eight weeks follow-up showed restored anatomical position of femoral condyle and PDFA. During anterior-distraction and angulation correction, tibia subluxated posteriorly, for that assembly extended to tibia which gradually translated tibia anteriorly and reduced knee. Twenty weeks after removal of assembly patient was advised knee-ankle-foot-orthosis. At 40 weeks of frame removal, patient was walking without support and pain. Managing such rare injuries with distraction-osteogenesis technique allows gradual correction and monitoring, till desirable degree of correction is achieved.
- Open Access
- 4 October 2019
- Published by Faculty of Medicine, Universitas Indonesia in Medical Journal of Indonesia
- Vol. 28 (3) , 252-7
Prevalence of methicillin-resistant Staphylococcus aureus and other pathogens in pus samples of orthopedic department at a tertiary care hospital in Pakistan
BACKGROUND Orthopedic infections are difficult to manage. Methicillin-resistant Staphylococcus aureus (MRSA) is one of the most dangerous and harmful bacteria and is difficult to eradicate because of its changing strains as well as sensitivity to different antibiotics. The main aim of this study was to determine the prevalence of pathogens, especially MRSA, associated with orthopedic wounds and their sensitivity to different antibiotics. METHODS A prospective study was conducted from September 2015 to August 2016. Pus samples of 1,350 patients who presented at the out-patient department or admitted with a wound infection after an orthopedic intervention were taken with the help of culture swab and were sent for culture and sensitivity according to hospital protocol. Data analyses were made using the SPSS software, version 17 (IBM). RESULTS Adults aged between 15 and 30 years were most affected, with 444 (32.9%) cases. Of the patients, 268 (19.9%) had negative cultures. Among the patients with positive cultures, the gram-positive cocci and gram-negative rods were 497 (36.8%) and 377 (27.9%), respectively. The most common pathogen was MRSA (240; 17.8%), followed by Escherichia coli and methicillin-sensitive S. aureus. CONCLUSIONS Multiple pathogens are involved in patients having an orthopedic surgical intervention. The high occurrence of MRSA and E. coli has an increasing economic burden on patients because of these pathogens high resistance to antibiotics. Thus, proper preventive measures should be done to decrease the occurrence of such infections as well as their associated morbidity.
- 4 October 2019
- Published by Faculty of Medicine, Universitas Indonesia in Medical Journal of Indonesia
- Vol. 28 (3) , 252-7
Open AccessPrevalence of methicillin-resistant Staphylococcus aureus and other pathogens in pus samples of orthopedic department at a tertiary care hospital in Pakistan
BACKGROUND Orthopedic infections are difficult to manage. Methicillin-resistant Staphylococcus aureus (MRSA) is one of the most dangerous and harmful bacteria and is difficult to eradicate because of its changing strains as well as sensitivity to different antibiotics. The main aim of this study was to determine the prevalence of pathogens, especially MRSA, associated with orthopedic wounds and their sensitivity to different antibiotics. METHODS A prospective study was conducted from September 2015 to August 2016. Pus samples of 1,350 patients who presented at the out-patient department or admitted with a wound infection after an orthopedic intervention were taken with the help of culture swab and were sent for culture and sensitivity according to hospital protocol. Data analyses were made using the SPSS software, version 17 (IBM). RESULTS Adults aged between 15 and 30 years were most affected, with 444 (32.9%) cases. Of the patients, 268 (19.9%) had negative cultures. Among the patients with positive cultures, the gram-positive cocci and gram-negative rods were 497 (36.8%) and 377 (27.9%), respectively. The most common pathogen was MRSA (240; 17.8%), followed by Escherichia coli and methicillin-sensitive S. aureus. CONCLUSIONS Multiple pathogens are involved in patients having an orthopedic surgical intervention. The high occurrence of MRSA and E. coli has an increasing economic burden on patients because of these pathogens high resistance to antibiotics. Thus, proper preventive measures should be done to decrease the occurrence of such infections as well as their associated morbidity.
- Open Access
- 27 August 2018
- Published by Springer Nature in European Spine Journal
- Vol. 27 (S6) , 786-795
The Global Spine Care Initiative: methodology, contributors, and disclosures
The purpose of this report is to describe the Global Spine Care Initiative (GSCI) contributors, disclosures, and methods for reporting transparency on the development of the recommendations.
- 27 August 2018
- Published by Springer Nature in European Spine Journal
- Vol. 27 (S6) , 786-795
Open AccessThe Global Spine Care Initiative: methodology, contributors, and disclosures
The purpose of this report is to describe the Global Spine Care Initiative (GSCI) contributors, disclosures, and methods for reporting transparency on the development of the recommendations.