YSYosra Saad

Yosra Saad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yosra Saad has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Marwa Selmi

    Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Monastir, Tunisia

    4 shared publications
  • Mohamed Hichem Gazzah

    Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Monastir, Tunisia

    4 shared publications
  • Hafedh Belmabrouk

    Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir, University of Monastir, Monastir, Tunisia

    3 shared publications
  • Hafedh Belmabrouk

    Department of Physics, College of Science Majmaah University Al Majma'ah Saudi Arabia

    2 shared publications
  • Karine Mougin

    University of Haute-Alsace, Institute of Materials Science of Mulhouse, IS2M-CNRS-UMR 7361, Mulhouse, France

    2 shared publications
  • Mohamed Hichem Gazzah

    Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir, University of Monastir, Monastir, Tunisia

    2 shared publications

Latest Publications

  • Sensitive Detection of SARS-CoV-2 Using a Novel Plasmonic Fiber Optic Biosensor Design

    by Yosra Saad, Mohamed Hichem Gazzah, Karine Mougin, Marwa Selmi, Hafedh Belmabrouk

    The coronavirus (COVID-19) pandemic has put the entire world at risk and caused an economic downturn in most countries. This work provided theoretical insight into a novel fiber optic-based plasmonic biosensor that can be used for sensitive detection of SARS-CoV-2. The aim was always to achieve reliable, sensitive, and reproducible detection. The proposed configuration is based on Ag-Au alloy nanoparticle films covered with a layer of graphene which promotes the molecular adsorption and a thiol-tethered DNA layer as a ligand. Here, the combination of two recent approaches in a single configuration is very promising and can only lead to considerable improvement. We have theoretically analyzed the sensor performance in terms of sensitivity and resolution. To highlight the importance of the new configuration, a comparison was made with two other sensors. One is based on gold nanoparticles incorporated into a host medium; the other is composed of a bimetallic Ag-Au layer in the massive state. The numerical results obtained have been validated and show that the proposed configuration offers better sensitivity (7100 nm\RIU) and good resolution (figure of merit; FOM = 38.88 \({RIU}^{-1}\) and signal-to-noise ratio; SNR = 0.388). In addition, a parametric study was performed such as the graphene layers’ number and the size of the nanoparticles.


  • Open Access

    Sensitive Detection of SARS-CoV-2 Using a Novel Plasmonic Fiber Optic Biosensor Design

    by Yosra Saad, Mohamed Hichem Gazzah, Karine Mougin, Marwa Selmi, Hafedh Belmabrouk

    The coronavirus (COVID-19) pandemic has put the entire world at risk and caused an economic downturn in most countries. This work provided theoretical insight into a novel fiber optic based plasmonic biosensor that can be used for sensitive detection of SARS-CoV-2. The aim was always to achieve reliable, sensitive and reproducible detection. The proposed configuration is based on Ag–Au alloy nanoparticles films covered with a layer of graphene which promotes the molecular adsorption and a thiol-tethered DNA layer as a ligand. Here the combination of two recent approaches in a single configuration is very promising and can only lead to considerable improvement. We have theoretically analyzed the sensor performance in terms of sensitivity and resolution. To highlight the importance of the new configuration, a comparison was made with two other sensors. One is based on gold nanoparticles incorporated into a host medium, the other is composed of a bimetallic Ag-Au layer in the massive state. The numerical results obtained has been validated and show that the proposed configuration offers better sensitivity (7100 nm\RIU) and good resolution (figure of merit; FOM=38.88Tand signal-to-noise ratio; SNR=0.388). In addition, a parametric study was performed such as the graphene layers number and the size of the nanoparticles.


  • Improvement of Mass Transport at the Surface of an SPR Biosensor Applied in Microfluidics

    by Yosra Saad, Marwa Selmi, Mohamed Hichem Gazzah, Hafedh Belmabrouk


  • Theoretical evaluation of a fiber-optic SPR biosensor based on a gold layer treated with thiol acid

    by Yosra Saad, Marwa Selmi, Mohamed Hichem Gazzah, Hafedh Belmabrouk

    In the present work, we have investigated the surface plasmons resonance (SPR) biosensor based on optical fiber applied for the detection of pathogenic bacteria (Escherichia coli), in order to overcome the stresses caused by the massive prism and to obtain a reliable and efficient miniature device. The modeling procedure is based on a matrix formalism developed for the optical studies of multilayer media. We have tested the response of the fiber optic biosensor based on a golden substrate functionalized with thiol acid. The results show that the SPR biosensor sensitivity is improved by treating the gold electrode with thiol. An improved SPR biosensor with a high resolution is obtained.


  • Graphene Effect on the Improvement of the Response of Optical Fiber SPR Sensor

    by Yosra Saad, Marwa Selmi, Mohamed Hichem Gazzah, Hafedh Belmabrouk

    In this study, we present a contribution to the development of a fiber-optic Surface Plasmon Resonance (SPR) sensor coated with a silver film that is suitable for chemical and biological applications. Indeed, the importance of the choice of the metal deposited on the sensitive zone of the sensor was verified. It has been found that silver-based sensors have better sensitivity. But on the other hand, it suffers from its poor chemical stability. In order to improve sensor stability, a protective layer of graphene was added, and an optimization of the geometrical and physical properties characteristic of the new configuration was presented by using a numerical study. The results obtained show that the sensitivity of the sensor depends on a set of parameters such as the diameter of the core (D), the sensitive length (L), the thickness of the metal layer (d) and its nature. The optimal choice of these parameters was fixed for the following values: D=400 μm, L=15 mm and d=50 nm.