Anastasia Dushina
Research Subjects
Research Interests
Anastasia Dushina has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Peter Wagner
Institute of Engineering Thermodynamics German Aerospace Center (DLR) Carl-von-Ossietzky-Str. 15 26129 Oldenburg Germany
10 shared publications - Alexander Dyck
DLR Institute of Networked Energy Systems
6 shared publications - Fabio La Mantia
Energiespeicher‐ und Energiewandlersysteme Universität Bremen Bibliothekstraße 1 28359 Bremen Germany
4 shared publications Alexander Dyck
3 shared publications- Dana Schonvogel
Institute of Engineering Thermodynamics German Aerospace Center (DLR) Carl-von-Ossietzky-Str. 15 26129 Oldenburg Germany
3 shared publications - Rafael Trócoli
Departamento de Química Inorgánica e Ingeniería Química Instituto Químico para la Energía y el Medio Ambiente (IQUEMA) Facultad de Ciencias Universidad de Córdoba Campus de Rabanales Córdoba 14071 Spain
3 shared publications
Latest Publications
- Open Access
- 14 November 2026
- Published by Springer Nature in Energy Informatics
- Vol. 9 (1) , 82
Pareto optimization of BEMU traction battery capacity and recharging infrastructure
The increasing integration of the energy and transport sectors requires efficient solutions for electrifying rail networks. Battery-powered trains (battery electric multiple units - BEMUs) offer a promising alternative to full electrification, but their range is limited by the current state of battery technology and recharging infrastructure. This study presents an optimization model that simultaneously optimizes the recharging infrastructure and traction batteries of the trains, enabling a system design based on BEMU power demand and timetable data. The model considers various factors, including route topology, timetable, charging infrastructure, and battery aging. A case study of a non-electrified mountain line considering two combinations of optimization targets and a case study for a long-distance line with partial electrification demonstrate the flexibility of the model and its applicability for different optimization tasks. The optimization results provide insights into the optimal dimensioning of charging infrastructure and batteries, considering factors such as heating ventilation and air conditioning (HVAC) demand, end-of-life capacity, discrete power of charging infrastructure, and battery replacement. Pareto-optimal system configurations are determined on the basis of stakeholder annuities (BEMU vs. electrification) and annuities versus minimal capacity buffer of the traction battery. Results indicate that Pareto-optimal BEMU annuities for the mountain line range from 1.27 to 1.31 mil€/a, whereas electrification annuities range from 0.50 to 1.36 mil€/a. This emphasizes designing systems for low electrification costs rather than low BEMU costs. The energy buffer of the traction batteries were increased by 37.2% by increasing the total annuity by 1.5%. A sensitivity analysis regarding parameters that define the Pareto front is conducted, which shows a shift in the Pareto fronts as a function of the sensitive parameters.
- 14 November 2026
- Published by Springer Nature in Energy Informatics
- Vol. 9 (1) , 82
Open AccessPareto optimization of BEMU traction battery capacity and recharging infrastructure
The increasing integration of the energy and transport sectors requires efficient solutions for electrifying rail networks. Battery-powered trains (battery electric multiple units - BEMUs) offer a promising alternative to full electrification, but their range is limited by the current state of battery technology and recharging infrastructure. This study presents an optimization model that simultaneously optimizes the recharging infrastructure and traction batteries of the trains, enabling a system design based on BEMU power demand and timetable data. The model considers various factors, including route topology, timetable, charging infrastructure, and battery aging. A case study of a non-electrified mountain line considering two combinations of optimization targets and a case study for a long-distance line with partial electrification demonstrate the flexibility of the model and its applicability for different optimization tasks. The optimization results provide insights into the optimal dimensioning of charging infrastructure and batteries, considering factors such as heating ventilation and air conditioning (HVAC) demand, end-of-life capacity, discrete power of charging infrastructure, and battery replacement. Pareto-optimal system configurations are determined on the basis of stakeholder annuities (BEMU vs. electrification) and annuities versus minimal capacity buffer of the traction battery. Results indicate that Pareto-optimal BEMU annuities for the mountain line range from 1.27 to 1.31 mil€/a, whereas electrification annuities range from 0.50 to 1.36 mil€/a. This emphasizes designing systems for low electrification costs rather than low BEMU costs. The energy buffer of the traction batteries were increased by 37.2% by increasing the total annuity by 1.5%. A sensitivity analysis regarding parameters that define the Pareto front is conducted, which shows a shift in the Pareto fronts as a function of the sensitive parameters.
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (39) , 1154
Electrochemical Investigation of Pt/Fe-N-C Catalysts as a Promising Low Pt-Loading Catalyst for Polymer Electrolyte Membrane Fuel Cells
Nowadays polymer electrolyte membrane fuel cells (PEMFC) become commercially established systems used in automobile, stationary and portable power generation industry which provide an improved kinetic, high efficiency, zero emission and high tolerance to the impurities. A standard catalyst used in PEMFC is based on Pt nanoparticles on carbon support materials. However, high cost of this critical raw material stimulates interest in the development of platinum group metals-free electrocatalysts (1). Fe-N-C materials are one of the promising non-precious metal electrocatalysts for these fuel cells which have recently reached outstanding performance in terms of oxygen reduction reaction (ORR) activity (2). However, the volumetric activity and durability of Fe-N-C catalyst is still significantly lower compared to Pt/C in PEMFC mainly due to their lower turnover frequency and active sites density (3). Therefore, in this work, a Black Pearl (BP) based Fe-N-C catalyst is used as ORR active support material for Pt-nanoparticles to investigate synergetic effects of active Pt and Fe-N sites towards stability and volumetric activity. We present a comparative electrochemical characterization of Pt/Fe-N-C and Pt/BP electrocatalysts with loadings of 0.01, 0.1 and 1 wt.% Pt. The measurements were done in terms of rotating ring-disk electrode experiments in 0.1 M HClO4 electrolyte under accelerated stress test (AST) during 5000 cycles in potential range 0.6 – 1.5 V vs RHE in N2-saturated electrolyte, in order to provoke Pt as well as carbon support degradation. The electrochemical surface area (ECSA) of the Pt was determined by hydrogen underpotential deposition (HUPD) and CO stripping methods before and after AST for Pt/BP catalysts. However, for Pt/Fe-N-C the ECSA determination was impossible because for metal-oxide supported Pt catalysts, a straightforward analysis of HUPD and CO methods fails to give meaningful values. The RRDE experiments revealed that ORR mass and specific activities were significantly decreased after AST especially for Pt/BP (Fig. 1) which was attributed to the platinum dissolution as well as carbon support degradation during cycling. 1. E. Eren, N. Özkan, Y. Devrim, Int J Hydrogen 2020, 45 (58), 33957-33967. 2. Y. He, S. Liu, C. Priest, Q.Shi , G. Wu, Chem. Soc. Rev., 2020, 11, 3484–3524. 3. T. Reshetenko, A. Serov, M. Odgaard, G. Randolf, L. Osmieri, A. Kulikovsky, Electrochem Commun 2020, 118, 106795. Figure 1. Cathodic scan of ORR curves of 0.1 wt.% Pt/BP catalyst with 40 µg cm-2 Pt loading in O2-saturated 0.1 M HClO4 at scan rate 5 mV s-1 by 1600 rpm before and after AST. Figure 1
- 19 October 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-02 (39) , 1154
Electrochemical Investigation of Pt/Fe-N-C Catalysts as a Promising Low Pt-Loading Catalyst for Polymer Electrolyte Membrane Fuel Cells
Nowadays polymer electrolyte membrane fuel cells (PEMFC) become commercially established systems used in automobile, stationary and portable power generation industry which provide an improved kinetic, high efficiency, zero emission and high tolerance to the impurities. A standard catalyst used in PEMFC is based on Pt nanoparticles on carbon support materials. However, high cost of this critical raw material stimulates interest in the development of platinum group metals-free electrocatalysts (1). Fe-N-C materials are one of the promising non-precious metal electrocatalysts for these fuel cells which have recently reached outstanding performance in terms of oxygen reduction reaction (ORR) activity (2). However, the volumetric activity and durability of Fe-N-C catalyst is still significantly lower compared to Pt/C in PEMFC mainly due to their lower turnover frequency and active sites density (3). Therefore, in this work, a Black Pearl (BP) based Fe-N-C catalyst is used as ORR active support material for Pt-nanoparticles to investigate synergetic effects of active Pt and Fe-N sites towards stability and volumetric activity. We present a comparative electrochemical characterization of Pt/Fe-N-C and Pt/BP electrocatalysts with loadings of 0.01, 0.1 and 1 wt.% Pt. The measurements were done in terms of rotating ring-disk electrode experiments in 0.1 M HClO4 electrolyte under accelerated stress test (AST) during 5000 cycles in potential range 0.6 – 1.5 V vs RHE in N2-saturated electrolyte, in order to provoke Pt as well as carbon support degradation. The electrochemical surface area (ECSA) of the Pt was determined by hydrogen underpotential deposition (HUPD) and CO stripping methods before and after AST for Pt/BP catalysts. However, for Pt/Fe-N-C the ECSA determination was impossible because for metal-oxide supported Pt catalysts, a straightforward analysis of HUPD and CO methods fails to give meaningful values. The RRDE experiments revealed that ORR mass and specific activities were significantly decreased after AST especially for Pt/BP (Fig. 1) which was attributed to the platinum dissolution as well as carbon support degradation during cycling. 1. E. Eren, N. Özkan, Y. Devrim, Int J Hydrogen 2020, 45 (58), 33957-33967. 2. Y. He, S. Liu, C. Priest, Q.Shi , G. Wu, Chem. Soc. Rev., 2020, 11, 3484–3524. 3. T. Reshetenko, A. Serov, M. Odgaard, G. Randolf, L. Osmieri, A. Kulikovsky, Electrochem Commun 2020, 118, 106795. Figure 1. Cathodic scan of ORR curves of 0.1 wt.% Pt/BP catalyst with 40 µg cm-2 Pt loading in O2-saturated 0.1 M HClO4 at scan rate 5 mV s-1 by 1600 rpm before and after AST. Figure 1
- 1 December 2020
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 45 (60) , 35073-35084
The influence of hydrogen sulphide contamination on platinum catalyst used in polymer electrolyte membrane fuel cells during potential cycling at 0.05–1.05 V vs RHE: An RRDE study
- 1 December 2020
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 45 (60) , 35073-35084
The influence of hydrogen sulphide contamination on platinum catalyst used in polymer electrolyte membrane fuel cells during potential cycling at 0.05–1.05 V vs RHE: An RRDE study
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (36) , 2339
Influence of Ammonia Contamination on HT-PEM Fuel Cell Platinum Catalyst
High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs) are considered as one of the promising types of power sources for automobile and stationary application. They have several advantageous characteristics, including high power density and efficiency, high tolerance against CO poisoning as well as zero-emission when using hydrogen and air as fuel and oxidant, respectively[1]. In the last decades HT-PEM fuel cells have been investigated extensively with the aim to introduce them into the market for commercial use. Gas impurities are one of the factors which can limit their durability and life time. Among them ammonia is a feed stream gas impurity which may contaminate the cathode as well as the anode of fuel cells. The main sources of ammonia traces come from hydrogen fuel produced from ammonia and from reforming of fossil fuel that contain species of nitrogen compounds[2]. Moreover, traces of ammonia in ambient air can occur in agricultural areas. The presence of ammonia traces was shown to decrease the performance of low temperature PEM fuel cells [3]. The ammonia species can effect on hydrogen oxidation reaction as well as oxygen reduction reaction affecting the catalyst and leading to reduced efficiency of fuel cells.[3] To the best of our knowledge, the effect of ammonia contamination on HT-PEM fuel cells and in particular on the carbon-supported platinum catalyst has not been fully explored yet. Therefore, the first aim of the present work is to investigate the effect of NH4 + poisoning on carbon-supported platinum in 0.5 mol L-1 H3PO4 in order to simulate the environment of HT-PEMFCs. The oxygen reduction reaction was studied in the presence of 10 ppm NH4 + ions using the rotating ring disk electrode (RRDE). In particular, activity of the Pt/C catalyst was determined before and after poisoning to evaluate the degradation. The effect of contamination on the performance loss, reduction of electrochemical active area and increase of H2O2 formation has been defined by RRDE measurements. In the second part, a commercially available membrane electrode assembly (MEA) was exposed to 10 ppm NH3 inside the air stream using a HT-PEM single cell test bench and applying a constant load of 0.3 A cm-2. Polarization curves and electrochemical impedance spectroscopy were used to investigate changes of the MEA performance. The RRDE study in H3PO4 electrolyte of the catalyst provides in combination with HT-PEM fuel cell testing an increased understanding of the NH3 impact on HT-PEMFC systems. Figure: CVs of Pt/C catalyst in 0.5 M H3PO4 at 50 mV/s in the potential range 0.05 – 1.5 V vs RHE in the absence and in the presence of 10 and 100 ppm NH4 +, respectively. [1] X. Cheng, Z. Shi, N. Glass, L. Zhang, J. Zhang, D. Song, Z.-S. Liu, H. Wang, J. Shen, J. Power Sources 2007, 165, 739-756. [2] X. Zhang, U. Pasaogullari, T. Molter, Int. J. Hydrogen Energy 2009, 34, 9188-9194. [3] F. A. Uribe, S. Gottesfeld, T. A. Zawodzinski, J. Electrochem. Soc. 2002, 149, A293-A296; R. Halseid, P. J. S. Vie, R. Tunold, J. Power Sources 2006, 154, 343-350. Figure 1
- 23 November 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-02 (36) , 2339
Influence of Ammonia Contamination on HT-PEM Fuel Cell Platinum Catalyst
High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs) are considered as one of the promising types of power sources for automobile and stationary application. They have several advantageous characteristics, including high power density and efficiency, high tolerance against CO poisoning as well as zero-emission when using hydrogen and air as fuel and oxidant, respectively[1]. In the last decades HT-PEM fuel cells have been investigated extensively with the aim to introduce them into the market for commercial use. Gas impurities are one of the factors which can limit their durability and life time. Among them ammonia is a feed stream gas impurity which may contaminate the cathode as well as the anode of fuel cells. The main sources of ammonia traces come from hydrogen fuel produced from ammonia and from reforming of fossil fuel that contain species of nitrogen compounds[2]. Moreover, traces of ammonia in ambient air can occur in agricultural areas. The presence of ammonia traces was shown to decrease the performance of low temperature PEM fuel cells [3]. The ammonia species can effect on hydrogen oxidation reaction as well as oxygen reduction reaction affecting the catalyst and leading to reduced efficiency of fuel cells.[3] To the best of our knowledge, the effect of ammonia contamination on HT-PEM fuel cells and in particular on the carbon-supported platinum catalyst has not been fully explored yet. Therefore, the first aim of the present work is to investigate the effect of NH4 + poisoning on carbon-supported platinum in 0.5 mol L-1 H3PO4 in order to simulate the environment of HT-PEMFCs. The oxygen reduction reaction was studied in the presence of 10 ppm NH4 + ions using the rotating ring disk electrode (RRDE). In particular, activity of the Pt/C catalyst was determined before and after poisoning to evaluate the degradation. The effect of contamination on the performance loss, reduction of electrochemical active area and increase of H2O2 formation has been defined by RRDE measurements. In the second part, a commercially available membrane electrode assembly (MEA) was exposed to 10 ppm NH3 inside the air stream using a HT-PEM single cell test bench and applying a constant load of 0.3 A cm-2. Polarization curves and electrochemical impedance spectroscopy were used to investigate changes of the MEA performance. The RRDE study in H3PO4 electrolyte of the catalyst provides in combination with HT-PEM fuel cell testing an increased understanding of the NH3 impact on HT-PEMFC systems. Figure: CVs of Pt/C catalyst in 0.5 M H3PO4 at 50 mV/s in the potential range 0.05 – 1.5 V vs RHE in the absence and in the presence of 10 and 100 ppm NH4 +, respectively. [1] X. Cheng, Z. Shi, N. Glass, L. Zhang, J. Zhang, D. Song, Z.-S. Liu, H. Wang, J. Shen, J. Power Sources 2007, 165, 739-756. [2] X. Zhang, U. Pasaogullari, T. Molter, Int. J. Hydrogen Energy 2009, 34, 9188-9194. [3] F. A. Uribe, S. Gottesfeld, T. A. Zawodzinski, J. Electrochem. Soc. 2002, 149, A293-A296; R. Halseid, P. J. S. Vie, R. Tunold, J. Power Sources 2006, 154, 343-350. Figure 1
- 8 September 2020
- Published by The Electrochemical Society in ECS Transactions
- Vol. 98 (9) , 537-552
Influence of Ammonia Contamination on HT-PEM Fuel Cell Platinum Catalyst
In this work the effect of NH3 contamination on platinum catalyst has been investigated in the frame of a high temperature polymer electrolyte membrane single fuel cell as well as rotating ring disk electrode measurements (RRDE) using phosphoric acid electrolyte. In the first part single cell operation in presence of 10 ppm NH3 in the cathode gas combined with electrochemical impedance spectroscopy was performed with a fuel cell test bench. In the second part of work RRDE experiments were accomplished in the presence of 10 and 100 ppm of NH4H2PO4 contamination in 0.5 mol L-1 H3PO4. It was revealed that platinum catalyst is strongly affected by ammonia contamination while the increasing ammonium concentrations reduce the electrochemical surface area (ECSA) of the Pt catalyst. These observed losses of ECSA were associated to adsorbed nitrogen compounds on the catalyst surface.
- 8 September 2020
- Published by The Electrochemical Society in ECS Transactions
- Vol. 98 (9) , 537-552
Influence of Ammonia Contamination on HT-PEM Fuel Cell Platinum Catalyst
In this work the effect of NH3 contamination on platinum catalyst has been investigated in the frame of a high temperature polymer electrolyte membrane single fuel cell as well as rotating ring disk electrode measurements (RRDE) using phosphoric acid electrolyte. In the first part single cell operation in presence of 10 ppm NH3 in the cathode gas combined with electrochemical impedance spectroscopy was performed with a fuel cell test bench. In the second part of work RRDE experiments were accomplished in the presence of 10 and 100 ppm of NH4H2PO4 contamination in 0.5 mol L-1 H3PO4. It was revealed that platinum catalyst is strongly affected by ammonia contamination while the increasing ammonium concentrations reduce the electrochemical surface area (ECSA) of the Pt catalyst. These observed losses of ECSA were associated to adsorbed nitrogen compounds on the catalyst surface.
- 1 February 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 449
Analysis of the regeneration behavior of high temperature polymer electrolyte membrane fuel cells after hydrogen starvation
- 1 February 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 449
Analysis of the regeneration behavior of high temperature polymer electrolyte membrane fuel cells after hydrogen starvation
- Open Access
Investigation of Corrosion Methods for Bipolar Plates for High Temperature Polymer Electrolyte Membrane Fuel Cell Application
In this work, different methods and electrochemical set-ups were investigated in order to study the corrosion behaviour of bipolar plates (BPP) for high temperature (HT) polymer electrolyte membrane fuel cell application. Using confocal and scanning electron microscopy, it was shown that chemical and electrochemical aging significantly increases surface roughness as well as morphology changes, confirming material degradation. Identical electrochemical corrosion behaviour was observed for both set-ups with typical quinone/hydroquinone peaks in the potential range ~0.6–0.7 V versus reversible hydrogen electrode (RHE). The appearance of the peaks and an increase of double layer capacitance can be related to the oxidation of carbon surface and, consequently, material corrosion. Simultaneously, an optimised corrosion set-up was introduced and verified regarding suitability. Both investigated set-ups and methods are useful to analyse the oxidation behaviour and corrosion resistance.
Open AccessInvestigation of Corrosion Methods for Bipolar Plates for High Temperature Polymer Electrolyte Membrane Fuel Cell Application
In this work, different methods and electrochemical set-ups were investigated in order to study the corrosion behaviour of bipolar plates (BPP) for high temperature (HT) polymer electrolyte membrane fuel cell application. Using confocal and scanning electron microscopy, it was shown that chemical and electrochemical aging significantly increases surface roughness as well as morphology changes, confirming material degradation. Identical electrochemical corrosion behaviour was observed for both set-ups with typical quinone/hydroquinone peaks in the potential range ~0.6–0.7 V versus reversible hydrogen electrode (RHE). The appearance of the peaks and an increase of double layer capacitance can be related to the oxidation of carbon surface and, consequently, material corrosion. Simultaneously, an optimised corrosion set-up was introduced and verified regarding suitability. Both investigated set-ups and methods are useful to analyse the oxidation behaviour and corrosion resistance.
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (35) , 1631
Effect of Hydrogen Sulphide Contamination on Platinum Catalyst Degradation in Polymer Electrolyte Membrane Fuel Cells
Platinum catalysts are widely used as electrocatalysts in polymer electrolyte membrane fuel cells (PEMFC). However, there are many factors that may lead to their degradation in PEMFC and one of them are impurities, which can penetrate the cell together with the feeding gases and then poison the catalyst [1]. Sulfur contaminants are strong undesirable poisons for the fuel cell even though they are usually present at very low levels (up to 5 ppm) in both fuel and air streams [2]. Hydrogen sulfide can adsorb onto platinum and affect the catalyst performance causing the loss of mass activity [3]. In this work the influence of H2S contamination on commercially available Pt catalyst with carbon support was studied by means of rotating ring-disk electrode experiments in perchloric acid. Accelerated stress testing (AST) was performed in terms of potential cycling up to 10.000 cycles in the absence of contaminants and in the presence of H2S for comparison. Cyclic voltammetry technique in terms of hydrogen under potential deposition (HUPD) and CO stripping was employed in order to determine the electrochemical surface area (ECSA). Oxygen reduction reaction (ORR) was used to identify kinetic parameters including kinetic limited current, Tafel slopes, mass and specific activity of the catalyst before and after degradation. After AST the platinum degradation was observed in the presence of the contaminant as well as in the absence of H2S. Highly reproducible measurements showed that derived from HUPD and CO methods ECSA in the presence of poisoning species was slightly higher in comparison to the ECSA obtained in the absence of contamination. In contrast, the calculated catalyst activity after stress test in the presence of contaminations dropped more significantly compared to the test without poisoning species. This fact may be attributed to the sulfur adsorption on the catalyst layer leading to morphology changes [3]. Moreover, the increased Tafel slopes after AST may be an indication of the changes of the ORR mechanism from a four electron reaction to a two electron process reaction. [1] R. Borup, Chemical Reviews 107 (2007) 3904–3951. [2] Fuel Cell Handbook, US Department of Energy (2008). [3] R. Mohtadi et al., Electrochemical and Solid-State Letters 6 (2003) A272–A274. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (35) , 1631
Effect of Hydrogen Sulphide Contamination on Platinum Catalyst Degradation in Polymer Electrolyte Membrane Fuel Cells
Platinum catalysts are widely used as electrocatalysts in polymer electrolyte membrane fuel cells (PEMFC). However, there are many factors that may lead to their degradation in PEMFC and one of them are impurities, which can penetrate the cell together with the feeding gases and then poison the catalyst [1]. Sulfur contaminants are strong undesirable poisons for the fuel cell even though they are usually present at very low levels (up to 5 ppm) in both fuel and air streams [2]. Hydrogen sulfide can adsorb onto platinum and affect the catalyst performance causing the loss of mass activity [3]. In this work the influence of H2S contamination on commercially available Pt catalyst with carbon support was studied by means of rotating ring-disk electrode experiments in perchloric acid. Accelerated stress testing (AST) was performed in terms of potential cycling up to 10.000 cycles in the absence of contaminants and in the presence of H2S for comparison. Cyclic voltammetry technique in terms of hydrogen under potential deposition (HUPD) and CO stripping was employed in order to determine the electrochemical surface area (ECSA). Oxygen reduction reaction (ORR) was used to identify kinetic parameters including kinetic limited current, Tafel slopes, mass and specific activity of the catalyst before and after degradation. After AST the platinum degradation was observed in the presence of the contaminant as well as in the absence of H2S. Highly reproducible measurements showed that derived from HUPD and CO methods ECSA in the presence of poisoning species was slightly higher in comparison to the ECSA obtained in the absence of contamination. In contrast, the calculated catalyst activity after stress test in the presence of contaminations dropped more significantly compared to the test without poisoning species. This fact may be attributed to the sulfur adsorption on the catalyst layer leading to morphology changes [3]. Moreover, the increased Tafel slopes after AST may be an indication of the changes of the ORR mechanism from a four electron reaction to a two electron process reaction. [1] R. Borup, Chemical Reviews 107 (2007) 3904–3951. [2] Fuel Cell Handbook, US Department of Energy (2008). [3] R. Mohtadi et al., Electrochemical and Solid-State Letters 6 (2003) A272–A274. Figure 1
- Open Access
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1477
Comparative Investigation of Polyphenylene Sulfide Polymer-Graphite Bipolar Plates for Fuel Cell Application
Bipolar plates (BPPs) are one of the key components of the polymer electrolyte membrane fuel cell (PEM FC) which play an important role in the development of fuel cell application. They should fulfil many functions in a fuel cell stack such as feeding H2 and O2 gases through the flow field upon operation, heat transfer, physical separation of individual fuel cells in series, collection and transport of electrons from anode to cathode of adjacent cells [1]. Among the BPPs used in PEM FC the polyphenylene sulfide (PPS) polymer-graphite BPP has a good electrical conductivity, lower cost, higher flexibility and chemical stability, in comparison to metallic and graphite plates. However, some challenges such as higher thickness and weight in comparison to metallic bipolar plates are limiting their use in automotive application [1]. In addition, it was reported that corrosion of carbon is taking place under operation conditions of fuel cells [2]. Therefore, in this work two compression molded commercial polyphenylene sulfide (PPS) polymer-graphite composite bipolar plates BPP-20 and BPP-15 from two different manufacturers with amount of PPS binder equal to 20 and 15 %, respectively, were employed for an analytical comparative investigation using physical and electrochemical analysis. Chemical stability of BPPs was investigated after storage in phosphoric acid. Corrosion resistance and electrochemical aging of the BPPs were studied by using linear sweep voltammetry, cyclic voltammetry and electrochemical impedance spectroscopy in phosphoric acid. In order to characterize the difference in physical properties water contact angle measurement and through-plane electrical conductivity experiments were performed. The morphology of the BPPs surfaces was determined by scanning electron and confocal microscopy. The chemical composition was investigated by X-ray diffraction and energy dispersive X-ray spectroscopy, respectively. Comparison of BPPs revealed that the surface roughness and electrical conductivity is lower while acid uptake and hydrophilicity is higher for BPP with higher amount of PPS. Moreover, there was a trend of reduced corrosion rate for BPP with increased PPS content. These properties could be explained based on structure and electrical characteristics of the materials. [1] S. S. Araya, F. Zhou, V. Liso, S. L. Sahlin, J. R. Vang, S. Thomas, X. Gao, C. Jeppesen, S. K. Kær, International Journal of Hydrogen Energy 2016, 41, 21310-21344. [2] T. Engl, L. Gubler, T. J. Schmidt, Journal of the Electrochemical Society 2015, 162, F291-F297. Figure 1
- 1 September 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-02 (33) , 1477
Open AccessComparative Investigation of Polyphenylene Sulfide Polymer-Graphite Bipolar Plates for Fuel Cell Application
Bipolar plates (BPPs) are one of the key components of the polymer electrolyte membrane fuel cell (PEM FC) which play an important role in the development of fuel cell application. They should fulfil many functions in a fuel cell stack such as feeding H2 and O2 gases through the flow field upon operation, heat transfer, physical separation of individual fuel cells in series, collection and transport of electrons from anode to cathode of adjacent cells [1]. Among the BPPs used in PEM FC the polyphenylene sulfide (PPS) polymer-graphite BPP has a good electrical conductivity, lower cost, higher flexibility and chemical stability, in comparison to metallic and graphite plates. However, some challenges such as higher thickness and weight in comparison to metallic bipolar plates are limiting their use in automotive application [1]. In addition, it was reported that corrosion of carbon is taking place under operation conditions of fuel cells [2]. Therefore, in this work two compression molded commercial polyphenylene sulfide (PPS) polymer-graphite composite bipolar plates BPP-20 and BPP-15 from two different manufacturers with amount of PPS binder equal to 20 and 15 %, respectively, were employed for an analytical comparative investigation using physical and electrochemical analysis. Chemical stability of BPPs was investigated after storage in phosphoric acid. Corrosion resistance and electrochemical aging of the BPPs were studied by using linear sweep voltammetry, cyclic voltammetry and electrochemical impedance spectroscopy in phosphoric acid. In order to characterize the difference in physical properties water contact angle measurement and through-plane electrical conductivity experiments were performed. The morphology of the BPPs surfaces was determined by scanning electron and confocal microscopy. The chemical composition was investigated by X-ray diffraction and energy dispersive X-ray spectroscopy, respectively. Comparison of BPPs revealed that the surface roughness and electrical conductivity is lower while acid uptake and hydrophilicity is higher for BPP with higher amount of PPS. Moreover, there was a trend of reduced corrosion rate for BPP with increased PPS content. These properties could be explained based on structure and electrical characteristics of the materials. [1] S. S. Araya, F. Zhou, V. Liso, S. L. Sahlin, J. R. Vang, S. Thomas, X. Gao, C. Jeppesen, S. K. Kær, International Journal of Hydrogen Energy 2016, 41, 21310-21344. [2] T. Engl, L. Gubler, T. J. Schmidt, Journal of the Electrochemical Society 2015, 162, F291-F297. Figure 1
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 635-645
Effect of Hydrogen Sulphide Contamination on Platinum Catalyst Degradation in Polymer Electrolyte Membrane Fuel Cells
The effect of H2S contamination on platinum catalyst in PEMFC has been investigated in terms of rotation disk electrode measurements in 0.1 M HClO4. The electrochemical surface area was determined by hydrogen underpotential deposition and CO stripping method before and after accelerated stress tests (AST). The observed losses of ECSA of the catalyst in the presence of H2S were associated to the adsorbed sulphur on the catalyst surface which changed cyclic voltammetric characteristics of the material.The RDE experiments revealed that ORR mass and specific activities were essentially decreased after AST with H2S contamination attributed to the interstitial defect on platinum atom sites due to the adsorbed sulphur. The HR-TEM has not revealed any significant differences between the catalyst surface morphology before and after test while EDX mapping indicated higher amount of the sulphur after AST confirming the presence of adsorbed sulphur species on the platinum catalyst surface.
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 635-645
Effect of Hydrogen Sulphide Contamination on Platinum Catalyst Degradation in Polymer Electrolyte Membrane Fuel Cells
The effect of H2S contamination on platinum catalyst in PEMFC has been investigated in terms of rotation disk electrode measurements in 0.1 M HClO4. The electrochemical surface area was determined by hydrogen underpotential deposition and CO stripping method before and after accelerated stress tests (AST). The observed losses of ECSA of the catalyst in the presence of H2S were associated to the adsorbed sulphur on the catalyst surface which changed cyclic voltammetric characteristics of the material.The RDE experiments revealed that ORR mass and specific activities were essentially decreased after AST with H2S contamination attributed to the interstitial defect on platinum atom sites due to the adsorbed sulphur. The HR-TEM has not revealed any significant differences between the catalyst surface morphology before and after test while EDX mapping indicated higher amount of the sulphur after AST confirming the presence of adsorbed sulphur species on the platinum catalyst surface.