Zhi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhi Zhang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Lie Lin
Tianjin Key Laboratory of Micro-Scale Optical Information Science and Technology
7 shared publications- Weiwei Liu
Nankai University
7 shared publications - Nan Zhang
Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Institute of Modern Optics, Nankai University, Tianjin, China
6 shared publications Lanjun Guo
Tianjin Key Laboratory of Optoelectronic Sensor and Sensing Network Technology
5 shared publicationsJiayun Xue
Tianjin Key Laboratory of Micro-Scale Optical Information Science and Technology
4 shared publications- Pengfei Qi
Institute of Modern Optics National Key Laboratory of Semiconductor Laser Nankai University Tianjin China
4 shared publications
Latest Publications
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (13) , 19645-19651
High-Sensitivity PDMS Film-Based Fabry–Pérot Interferometer for Magnetic Field Sensing via Magnetic Fluid Volume Effect
reflective fiber-optic magnetic field sensor based on the magnetic fluid (MF) magnetic volume effect is proposed. The sensor incorporates a Fabry-Pérot (F-P) interference structure formed by a single-mode fiber (SMF) and a polydimethylsiloxane (PDMS) film. By detecting the volume changes of MF under varying magnetic field strengths, the sensor achieves highly sensitive magnetic field measurement. When exposed to an external magnetic field, the nanoparticles in the MF undergo oriented alignment, resulting in anisotropic volume changes. These changes are transmitted to the F-P air cavity via the PDMS film, enabling precise measurement of magnetic field intensity. Experimental results demonstrate that with a 48.4 μm-thick PDMS film, the sensor achieves axial and radial magnetic field sensitivities of -2.3 nm/mT and -2.73 nm/mT, respectively, within the 0-12 mT range. Furthermore, we observed that reducing the PDMS film thickness significantly enhances magnetic field sensitivity. After optimization to 46.92 μm, the sensor achieved a radial sensitivity of -9.40 nm/mT, a detection limit of 0.0021 mT, and excellent linearity (R2 = 0.9988). The sensor combines the advantages of simple structure, high sensitivity and low fabrication cost, which provides a new solution for magnetic field measurement in the fields of power equipment monitoring and aerospace.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (13) , 19645-19651
High-Sensitivity PDMS Film-Based Fabry–Pérot Interferometer for Magnetic Field Sensing via Magnetic Fluid Volume Effect
reflective fiber-optic magnetic field sensor based on the magnetic fluid (MF) magnetic volume effect is proposed. The sensor incorporates a Fabry-Pérot (F-P) interference structure formed by a single-mode fiber (SMF) and a polydimethylsiloxane (PDMS) film. By detecting the volume changes of MF under varying magnetic field strengths, the sensor achieves highly sensitive magnetic field measurement. When exposed to an external magnetic field, the nanoparticles in the MF undergo oriented alignment, resulting in anisotropic volume changes. These changes are transmitted to the F-P air cavity via the PDMS film, enabling precise measurement of magnetic field intensity. Experimental results demonstrate that with a 48.4 μm-thick PDMS film, the sensor achieves axial and radial magnetic field sensitivities of -2.3 nm/mT and -2.73 nm/mT, respectively, within the 0-12 mT range. Furthermore, we observed that reducing the PDMS film thickness significantly enhances magnetic field sensitivity. After optimization to 46.92 μm, the sensor achieved a radial sensitivity of -9.40 nm/mT, a detection limit of 0.0021 mT, and excellent linearity (R2 = 0.9988). The sensor combines the advantages of simple structure, high sensitivity and low fabrication cost, which provides a new solution for magnetic field measurement in the fields of power equipment monitoring and aerospace.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6785-6791
Polymer-Integrated Fiber Parallel Fabry–Perot Cavity Sensor Based on Ti 3 C 2 T x MXene-Enhanced Photothermal Effect for Myoglobin Detection
Acute myocardial infarction (AMI) is one of the leading causes of death in most developing and developed countries worldwide. As an important biomarker for the early diagnosis of AMI, myoglobin (Mb) renders the development of rapid and accurate detection technologies for it of great research signifi-cance. This paper proposes a parallel optical fiber Fabry-Perot (FP) cavity biosensor using polydimethylsiloxane (PDMS) as the functional cavity and Ti3C2Tx MXene as the sensitizing material. PDMS has an extremely high thermal expansion coefficient, enabling it to convert the thermal signal generated by Mb under 405 nm laser irradiation into a change in cavity length. Ti3C2Tx MXene can enhance the adsorption capacity of the sensing tip for Mb molecules. Paralleling two FP cavities with similar structures but different cavity lengths creates a Vernier effect, which can amplify spectral drift. Experimental results show that the sensor achieves a sensitivity of 4.515 nm/(mg/L) in the concentration range of 0.0001–10 mg/L, with a limit of detection (LOD) of 4.429 ng/ml. The proposed sensor features high sensitivity, a wide detection range, and strong robustness, with a detection time as short as 15 seconds. It holds potential application value in the field of early and rapid diagnosis of acute myocardial infarction.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6785-6791
Polymer-Integrated Fiber Parallel Fabry–Perot Cavity Sensor Based on Ti 3 C 2 T x MXene-Enhanced Photothermal Effect for Myoglobin Detection
Acute myocardial infarction (AMI) is one of the leading causes of death in most developing and developed countries worldwide. As an important biomarker for the early diagnosis of AMI, myoglobin (Mb) renders the development of rapid and accurate detection technologies for it of great research signifi-cance. This paper proposes a parallel optical fiber Fabry-Perot (FP) cavity biosensor using polydimethylsiloxane (PDMS) as the functional cavity and Ti3C2Tx MXene as the sensitizing material. PDMS has an extremely high thermal expansion coefficient, enabling it to convert the thermal signal generated by Mb under 405 nm laser irradiation into a change in cavity length. Ti3C2Tx MXene can enhance the adsorption capacity of the sensing tip for Mb molecules. Paralleling two FP cavities with similar structures but different cavity lengths creates a Vernier effect, which can amplify spectral drift. Experimental results show that the sensor achieves a sensitivity of 4.515 nm/(mg/L) in the concentration range of 0.0001–10 mg/L, with a limit of detection (LOD) of 4.429 ng/ml. The proposed sensor features high sensitivity, a wide detection range, and strong robustness, with a detection time as short as 15 seconds. It holds potential application value in the field of early and rapid diagnosis of acute myocardial infarction.
- 30 May 2025
- Published by Optica Publishing Group in Photonics Research
- Vol. 13 (6) , 1691
Polarization-dependent neutral nitrogen fluorescence induced by long-distance laser filamentation
Femtosecond laser filamentation has attracted significant attention due to its applications in remote sensing of atmospheric pollutants and artificial weather intervention. Nitrogen is the most abundant gas in the atmosphere, and its stimulated ultraviolet emission is remarkably clean, distinctly different from the fluorescence obtained through electron impact or laser breakdown. While numerous experiments and mechanism analyses have been conducted on its characteristic fluorescence excited by laser filamentation, they predominantly focused on short-distance filamentation (less than 1 m). Contrary to previous reports, we find that at long distances (30 m), the fluorescence intensity of neutral nitrogen molecules excited by linearly polarized laser pulses is approximately 7 times that excited by circularly polarized pulses with the same energy. This enhancement is caused by the enhanced tunneling ionization rate, 3.7 times that under circular polarization, and the elongated filament length, 1.85 times that under circular polarization, when using linear polarization. Additionally, after comparing existing theories for N2(C3Πu)) excitation, the dissociation-recombination model is found to be more appropriate for explaining the formation of N2(C3Πu)) excited states during long-distance filamentation.
- 30 May 2025
- Published by Optica Publishing Group in Photonics Research
- Vol. 13 (6) , 1691
Polarization-dependent neutral nitrogen fluorescence induced by long-distance laser filamentation
Femtosecond laser filamentation has attracted significant attention due to its applications in remote sensing of atmospheric pollutants and artificial weather intervention. Nitrogen is the most abundant gas in the atmosphere, and its stimulated ultraviolet emission is remarkably clean, distinctly different from the fluorescence obtained through electron impact or laser breakdown. While numerous experiments and mechanism analyses have been conducted on its characteristic fluorescence excited by laser filamentation, they predominantly focused on short-distance filamentation (less than 1 m). Contrary to previous reports, we find that at long distances (30 m), the fluorescence intensity of neutral nitrogen molecules excited by linearly polarized laser pulses is approximately 7 times that excited by circularly polarized pulses with the same energy. This enhancement is caused by the enhanced tunneling ionization rate, 3.7 times that under circular polarization, and the elongated filament length, 1.85 times that under circular polarization, when using linear polarization. Additionally, after comparing existing theories for N2(C3Πu)) excitation, the dissociation-recombination model is found to be more appropriate for explaining the formation of N2(C3Πu)) excited states during long-distance filamentation.
- 22 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (3) , 550-553
Coupled air lasing gain and Mie scattering loss: an aerosol effect in filament-induced plasma spectroscopy
Femtosecond laser filament-induced plasma spectroscopy (FIPS) demonstrates great potential in remote sensing for identifying atmospheric pollutant molecules. Due to the widespread aerosols in the atmosphere, remote detection based on FIPS would be affected by both the excitation and the propagation of fingerprint fluorescence, which still remain elusive. Here the physical model of filament-induced aerosol fluorescence is established to reveal the combined effect of Mie scattering and amplification spontaneous emission, which is subsequently proven by experimental results, the dependence of the backward fluorescence on the interaction length between filaments and aerosols. These findings provide an insight into the complicated aerosol effect in the overall physical process of FIPS including propagation, excitation, and emission, paving the way to its practical application in atmospheric remote sensing.
- 22 January 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (3) , 550-553
Coupled air lasing gain and Mie scattering loss: an aerosol effect in filament-induced plasma spectroscopy
Femtosecond laser filament-induced plasma spectroscopy (FIPS) demonstrates great potential in remote sensing for identifying atmospheric pollutant molecules. Due to the widespread aerosols in the atmosphere, remote detection based on FIPS would be affected by both the excitation and the propagation of fingerprint fluorescence, which still remain elusive. Here the physical model of filament-induced aerosol fluorescence is established to reveal the combined effect of Mie scattering and amplification spontaneous emission, which is subsequently proven by experimental results, the dependence of the backward fluorescence on the interaction length between filaments and aerosols. These findings provide an insight into the complicated aerosol effect in the overall physical process of FIPS including propagation, excitation, and emission, paving the way to its practical application in atmospheric remote sensing.
- 10 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 28586-28595
Sub-ppb NaCl aerosol detection at a distance of 30 meters by femtosecond laser induced plasma spectroscopy
In this work, sub-ppb aerosol detection is achieved by femtosecond laser filament with a single pulse energy of 4 mJ at a distance of 30 m. A concave mirror with an open aperture of 41.4 cm is employed in an off-axis optical system to focus the femtosecond laser beam and collect the fluorescence of NaCl aerosol. The simulation and experimental results show that the astigmatism can be greatly reduced when femtosecond laser beam is incident non-symmetrically on the concave mirror. Compared with the case that femtosecond laser strikes at the center of the concave mirror, the intensity of acoustic signal emitted from the optical filament is increased by 69.5 times, and the detection of limit of sodium element in aerosol is reduced by 86%, which is down to 0.32 ppb. The improved excitation scheme in this work utilizes the nonsymmetrical beam spot on the concave mirror to compensate the non-symmetry induced by the off-axis setup, reducing the astigmatism of the focusing laser beam and decreasing the sodium chloride aerosol’s detection of limit.
- 10 August 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 28586-28595
Sub-ppb NaCl aerosol detection at a distance of 30 meters by femtosecond laser induced plasma spectroscopy
In this work, sub-ppb aerosol detection is achieved by femtosecond laser filament with a single pulse energy of 4 mJ at a distance of 30 m. A concave mirror with an open aperture of 41.4 cm is employed in an off-axis optical system to focus the femtosecond laser beam and collect the fluorescence of NaCl aerosol. The simulation and experimental results show that the astigmatism can be greatly reduced when femtosecond laser beam is incident non-symmetrically on the concave mirror. Compared with the case that femtosecond laser strikes at the center of the concave mirror, the intensity of acoustic signal emitted from the optical filament is increased by 69.5 times, and the detection of limit of sodium element in aerosol is reduced by 86%, which is down to 0.32 ppb. The improved excitation scheme in this work utilizes the nonsymmetrical beam spot on the concave mirror to compensate the non-symmetry induced by the off-axis setup, reducing the astigmatism of the focusing laser beam and decreasing the sodium chloride aerosol’s detection of limit.
- 8 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (4) , 6464-6474
Detection of 1.4 μg/m3 Na+ in aerosol at a 30 m distance using 1 kHz femtosecond laser filamentation in air
An optimized remote material detection scheme based on the laser filament-induced plasma spectroscopy and light detection and ranging (FIPS-LIDAR) is proposed in this work. The elemental composition and concentration of aerosol are measured by FIPS-LIDAR. By focusing the femtosecond laser with a large aperture (Φ41 cm) concave mirror and coaxial fluorescence collection scheme, the remote detection of aerosol in air at μg/m3 level has been realized at a distance of 30 m. The limit of detection for Na+ in aerosol droplets is 8 ppm (3 μg/m3 in air), which is the lowest detection limit that has been reported using millijoule femtosecond laser pulse (4.4 mJ). Furthermore, using spectral preprocessing and optimization of the proposed significance of peak (SOP) algorithm, feature peak signals are extracted from weak signals and the limit of detection can be further decreased to 1.4 μg/m3.
- 8 February 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (4) , 6464-6474
Detection of 1.4 μg/m3 Na+ in aerosol at a 30 m distance using 1 kHz femtosecond laser filamentation in air
An optimized remote material detection scheme based on the laser filament-induced plasma spectroscopy and light detection and ranging (FIPS-LIDAR) is proposed in this work. The elemental composition and concentration of aerosol are measured by FIPS-LIDAR. By focusing the femtosecond laser with a large aperture (Φ41 cm) concave mirror and coaxial fluorescence collection scheme, the remote detection of aerosol in air at μg/m3 level has been realized at a distance of 30 m. The limit of detection for Na+ in aerosol droplets is 8 ppm (3 μg/m3 in air), which is the lowest detection limit that has been reported using millijoule femtosecond laser pulse (4.4 mJ). Furthermore, using spectral preprocessing and optimization of the proposed significance of peak (SOP) algorithm, feature peak signals are extracted from weak signals and the limit of detection can be further decreased to 1.4 μg/m3.
- 26 October 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (21) , 5676-5679
Effect of laser repetition rate on the fluorescence characteristic of a long-distance femtosecond laser filament
In this paper, the effect of the laser repetition rate on the long-distance femtosecond laser filament in air is investigated by measuring the fluorescence characteristic of the filament. A femtosecond laser filament emits fluorescence due to the thermodynamical relaxation of the plasma channel. Experimental results show that as the repetition rate of femtosecond laser increases, the fluorescence of the filament induced by a single laser pulse weakens, and the position of the filament moves away from the focusing lens. These phenomena may be attributed to the slow hydrodynamical recovery process of air after being excited by a femtosecond laser filament, whose characteristic time is on the millisecond time scale and comparable to the inter-pulse duration of the femtosecond laser pulse train. This finding suggests that at a high laser repetition rate, to generate an intense laser filament, the femtosecond laser beam should scan across the air to eliminate the adverse effect of slow air relaxation, which is beneficial to laser filament remote sensing.
- 26 October 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (21) , 5676-5679
Effect of laser repetition rate on the fluorescence characteristic of a long-distance femtosecond laser filament
In this paper, the effect of the laser repetition rate on the long-distance femtosecond laser filament in air is investigated by measuring the fluorescence characteristic of the filament. A femtosecond laser filament emits fluorescence due to the thermodynamical relaxation of the plasma channel. Experimental results show that as the repetition rate of femtosecond laser increases, the fluorescence of the filament induced by a single laser pulse weakens, and the position of the filament moves away from the focusing lens. These phenomena may be attributed to the slow hydrodynamical recovery process of air after being excited by a femtosecond laser filament, whose characteristic time is on the millisecond time scale and comparable to the inter-pulse duration of the femtosecond laser pulse train. This finding suggests that at a high laser repetition rate, to generate an intense laser filament, the femtosecond laser beam should scan across the air to eliminate the adverse effect of slow air relaxation, which is beneficial to laser filament remote sensing.
- 4 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (21) , 38745-38752
Giant enhancement of acoustic and fluorescence emission from an off-axis reflective femtosecond laser filamentation system
Femtosecond laser filamentation propagating tens of meters to several kilometers with high intensity in the atmosphere has been demonstrated as a powerful tool for remote sensing. In contrast to the refractive systems, the reflective optical systems possess a variety of advantages including broad bandwidth, large aperture, light weight and low energy loss. However, astigmatic aberration is inevitably introduced by off-axis reflective mirrors. It can greatly affect the filament quality, which is critical for exciting and detecting the fluorescence of target molecules. Here we elaborately design a free-form phase plate to correct the astigmatism in off-axis reflective optical systems. It is demonstrated that the free-form surface exhibits excellent performance, significantly reducing the astigmatic difference from 44 cm to 4 cm and increasing the maximum acoustic intensity by a factor of 53. In addition, extremely strong nitrogen fluorescence spectra have been detected. These results indicate that the free-form phase plate can effectively compensate for astigmatic aberration in off-axis reflective system, providing a guiding significance for the optimal control of filamentation and remote sensing.
- 4 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (21) , 38745-38752
Giant enhancement of acoustic and fluorescence emission from an off-axis reflective femtosecond laser filamentation system
Femtosecond laser filamentation propagating tens of meters to several kilometers with high intensity in the atmosphere has been demonstrated as a powerful tool for remote sensing. In contrast to the refractive systems, the reflective optical systems possess a variety of advantages including broad bandwidth, large aperture, light weight and low energy loss. However, astigmatic aberration is inevitably introduced by off-axis reflective mirrors. It can greatly affect the filament quality, which is critical for exciting and detecting the fluorescence of target molecules. Here we elaborately design a free-form phase plate to correct the astigmatism in off-axis reflective optical systems. It is demonstrated that the free-form surface exhibits excellent performance, significantly reducing the astigmatic difference from 44 cm to 4 cm and increasing the maximum acoustic intensity by a factor of 53. In addition, extremely strong nitrogen fluorescence spectra have been detected. These results indicate that the free-form phase plate can effectively compensate for astigmatic aberration in off-axis reflective system, providing a guiding significance for the optimal control of filamentation and remote sensing.
- 3 January 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 11 (3) , 730-734
Effect of Molecular Orbital Angular Momentum on the Spatial Distribution of Fluorescence during Femtosecond Laser Filamentation in Air
Non-uniform azimuthal distribution of N2+ fluorescence emitted from the femtosecond laser filament in air was discovered. The fluorescence is stronger when the detector is placed perpendicular or parallel to the laser polarization. The experimental results have been confirmed by the theoretical calculation that the azimuthal distribution of fluorescence is reproduced by the convolution of the transition of dipole and the molecular alignment in the strong laser field. The results would provide new insight into laser-molecule interactions during filamentation, which are important in practice for remote-sensing using filamentation.
- 3 January 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 11 (3) , 730-734
Effect of Molecular Orbital Angular Momentum on the Spatial Distribution of Fluorescence during Femtosecond Laser Filamentation in Air
Non-uniform azimuthal distribution of N2+ fluorescence emitted from the femtosecond laser filament in air was discovered. The fluorescence is stronger when the detector is placed perpendicular or parallel to the laser polarization. The experimental results have been confirmed by the theoretical calculation that the azimuthal distribution of fluorescence is reproduced by the convolution of the transition of dipole and the molecular alignment in the strong laser field. The results would provide new insight into laser-molecule interactions during filamentation, which are important in practice for remote-sensing using filamentation.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental Results of Spectral and Imaging from Tunable Coherent Terahertz Radiation
In this paper, we demonstrate the generation and observation of watt-level, coherent tunable terahertz radiation from relativistic femtosecond electron beam. Spectral content of the coherent terahertz emission from the undulator and dipole magnet is measured, and high quality terahertz imaging experimental is carried utilizing methodology of super-resolution reconstruction.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental Results of Spectral and Imaging from Tunable Coherent Terahertz Radiation
In this paper, we demonstrate the generation and observation of watt-level, coherent tunable terahertz radiation from relativistic femtosecond electron beam. Spectral content of the coherent terahertz emission from the undulator and dipole magnet is measured, and high quality terahertz imaging experimental is carried utilizing methodology of super-resolution reconstruction.