MAMohamed El Atrash

Mohamed El Atrash

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohamed El Atrash has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Low-Profile Fully Fabric High Isolation Dual-Port MIMO Antenna for UWB Wearable Applications

    by Mohamed El Atrash, Mennaalla S. Khalil, Waad A. Mahmoud, Mahmoud A. Abdalla

    compact, 2-port Multiple-Input-Multiple-Output (MIMO) antenna that is entirely made of textile is proposed for Ultra-Wide-Band (UWB) wearable applications. The conductive parts of the MIMO antenna are made of ShieldIt with a conductivity of 1.8 × 105 S/m and thickness of 0.17 mm. The MIMO antenna is mounted on a 1.5 mm thick Felt substrate. The designed MIMO antenna has a compact size of 30 mm  45 mm and operates over the UWB frequency band ranging from 3.1 GHz to 10.6 GHz. It displayed an average radiation efficiency of 85.5% and a peak gain of 5 dBi within the UWB spectrum. To reduce the mutual coupling between the antenna elements, two approaches are applied. Orienting one radiator by 180° with respect to the other and adding a parasitic structure in-between the 2 radiators led to achieving a high isolation amongst the antennas. This is inspected through analyzing the achieved outcomes of S21 < −25 dB, very low Envelope Correlation Coefficient (ECC) < 0.001, high Diversity Gain (DG) > 9.995 dB, and low Channel Capacity Loss (CCL) < 0.2bits/s/Hz throughout the UWB spectrum. Furthermore, the Specific Absorption Rate (SAR) is lower than 1.6 W/kg, averaged over 1g of tissue, at various frequencies. Finally, the MIMO antenna was manually fabricated, where the tested outcomes matched with the simulated ones. Compared to the published work, the proposed antenna has a compact size, high radiation efficiency, has a bendable platform and achieves very competitive MIMO parameter. Therefore, the proposed MIMO antenna can be highly suggested for UWB wearable applications.


  • A Compact Dual-Band ACS-Fed Frequency Independent Hook Loop Antenna for WLAN Applications

    by Arvind Kumar, Praveen V. Naidu, Mohamed El Atrash, Vinay Kumar, Mahmoud A. Abdalla

  • A quad-band miniaturised compact Π-shaped CSRR-based metamaterial-inspired DG resonator antenna

    by Mahmoud A. Abdalla, Walaa W. Wahba, Mohamed El Atrash

    Proposed in this paper is a new configuration for a quad-band antenna based on using a metamaterial-inspired defected ground structure. The presented structure is introduced as a new modified metamaterial Complementary Split Ring Resonator (CSRR) with a compact electrical size. The new modified CSRR has been employed in Composite Right/Left-Handed (CRLH) transmission line configuration for ultra-size reduction. Validation for the particle small size is introduced and the detailed analysis for the NRI characteristics has been discussed by extracting the cell constitutive parameters. Hence, a multi-band antenna is designed based on using only one cell of the proposed NRI-TL. Subsequently, a small multi-band antenna is presented for different multi-band functionalities and different radiation properties. The antenna displays quad-resonances at 1.78 GHz, with the typical omnidirectional radiation pattern, 3.28 GHz, 4 GHz, and 4.3 GHz, with the directive broadside radiation properties. The proposed antenna footprint is 10 × 10 cm2, which exhibits a size reduction of up to 80% in comparison with a rectangular patch antenna operating at the lowest frequency band.


  • Dual-band all textile antenna with AMC for heartbeat monitor and pacemaker control applications

    by Farah R. Kareem, Mohamed El Atrash, Ahmed A. Ibrahim, Mahmoud A. Abdalla

    All textile integrated dual-band monopole antenna with an artificial magnetic conductor (AMC) is proposed. The proposed design operates at 2.4 and 5.8 GHz for wearable medical applications to monitor the heartbeat. A flexible and low-profile E- shaped CPW dual-band textile antenna is integrated with a 4 × 4 dual-band textile AMC reflector to enhance the gain and specific absorption rate (SAR). The SAR is reduced by nearly 95% at both 1 and 10 g. The design was measured on the body with a 2 mm separation. The simulated and measured results appear in high agreement in the case of with and without AMC array integration. The measurement was performed in the indoor environment and in an anechoic chamber to validate the design based on reflection coefficient and radiation pattern measurements.


  • A compact dual-band D-CRLH-based antenna with self-isolation functionality

    by Mahmoud A. Abdalla, Mohamed El Atrash, Ahmed A. Abdel Aziz, Mohamed I. Abdelnaser

    This paper presents a compact dual-band filtering antenna without extra employing of filter structures. The antenna is designed using a planar dual-composite right/left-handed (D-CRLH) transmission line unit cell, where the filtering function is achieved through current cancellation between the D-CRLH resonators. The antenna is designed to function at 3.0 and 5.1 GHz, which can serve different WLAN applications. The antenna is a co-planar waveguide fed with a very compact size of only 30 × 16 mm2. Compared to the conventional patch antenna, the antenna size is only 17% at 3.0 GHz and 31% at 5.1 GHz. Despite the small size, the antenna preserves a good omni-directional radiation pattern at the two resonant frequencies with a measured realized gain of 2 and 2.7 dB, respectively. At the stopband in-between the two resonant bands, the reflection coefficient is almost 0 dB at 4.25 GHz and complete non-radiation is proved with a −11 dB measured realized gain. The different antenna filtering functions are verified by full-wave simulation and measurements.


  • Concept and analysis of a coupled split-ring resonator for wide-/dual bands, self-filtering, high out-of-band suppression and highly efficient antennas

    by Mahmoud A. Abdalla, Mohamed El Atrash, Nour A. El-Sobky, Sherif R. Zahran

    An inspired metamaterial-based highly efficient monopole antenna displaying wide-/dual-band resonances along with self-filtering properties is presented. The monopole has high out-of-band suppression characteristics that lead to very close to 0 dB band-stop between the antenna dual resonant bands. The antenna operates at the two WLAN services of 2.65-3.25 and 5-7 GHz with stopband with total reflection at 4.5 GHz. The designed filtering characteristics are based on current coupling for the dual-band functions and current neutralization for the stopband function. Moreover, the proposed antenna has a very high radiation efficiency of 97 and 99% at 3 and 6 GHz, respectively. Furthermore, the proposed antenna exhibits an omni-directional radiation pattern with coplanar waveguide feed for simple integration with passive/active devices. Moreover, the antenna properties are achieved with a compact antenna size (30 x 30 mm(2)). With all presented results, the proposed antenna is very competitive over recent relevant antennas. In addition, a very good agreement between theoretical, full-wave simulations and measurements is achieved.


  • Open Access

    Fully Fabric High Impedance Surface-Enabled Antenna for Wearable Medical Applications

    by Adel Y. I. Ashyap, Samsul Haimi Bin Dahlan, Zuhairiah Zainal Abidin, Sharul Kamal Abdul Rahim, Huda A. Majid, Abdulrahman S. M. Alqadami, Mohamed El Atrash

    The compact and robust high-impedance surface (HIS) integrated with the antenna is designed to operate at a frequency of 2.45 GHz for wearable applications. They are made of highly flexible fabric material. The overall size is $45\times \,\,45\times 2.4$ mm 3 which equivalent to $0.37\lambda \text{o}\times 0.37\lambda \text{o}\times 0.02$ mm 3 . The value of using HIS lies in protecting the human body from harmful radiation and maintaining the performance of the antenna, which may be affected by the high conductivity of the human body. Besides, setting the antenna on the human body by itself detunes the frequency, but by adding HIS, it becomes robust and efficient for body loading and deformation. Integrated antenna with HIS demonstrates excellent performance, such as a gain of 7.47 dBi, efficiency of 71.8% and FBR of 10.8 dB. It also reduces the SAR below safety limits. The reduction is more than 95%. Therefore, the presented design was considered suitable for wearable applications. Further study was also performed to show the useful of placing antenna over HIS compared to the use of perfect electric conductor (PEC). The integrated design was also investigated with the worst case of varying the permittivity of body equivalent model which shows excellent performance in term of reflection coefficient and SAR levels. Hence, the integrated antenna with HIS is mechanically robust to human body tissue loading, and it is highly appropriate for body-worn applications.


  • A fully-textile wideband AMC-backed antenna for wristband WiMAX and medical applications

    by Mohamed El Atrash, Mahmoud A. Abdalla, Hadia M. Elhennawy

    Proposed is a wideband, low profile, fully flexible, and all-textile-based slotted triangular antenna loaded with a 2 × 2 textile-inspired artificial magnetic conductor to be worn on the wrist. The integrated antenna design is designed to cover the frequency band from 3.1 to 6.5 GHz. The integrated design has two main resonances, where the first one is at 3.5 GHz, which can serve the WiMAX communication standard, while the second is at 5.8 GHz, which can serve the Industrial, Scientific and Medical (ISM)-band. The incorporated textile materials are composed of the conductive and dielectric fabrics that are realized by ShieldIt and Felt, respectively. When simulated against the human model wrist, the integrated antenna design displayed a realized gain of 6.71 dBi and radiation efficiency of 79.1%, at 3.5 GHz. Furthermore, at 5.8 GHz, it displayed a realized gain of 7.82 dBi and total efficiency performances of 66.1%. Moreover, it accomplished very low SAR levels within the antenna frequency band. Averaged over 1 g of tissue, it exhibited maximum SAR levels of 3.28 × 10−6 and 9.37 × 10−7 W/kg at 3.5 and 5.8 GHz, respectively. For the bent scenarios, the integrated antenna design displayed robustness when bent at an angle of 20 and 40°. Finally, measurement results are illustrated and analyzed. Based on the presented results, the suggested all-textile integrated antenna design might be designated for integration with the wristband to monitor the user health conditions through many possible frequency channels.


  • A Compact Highly Efficient Π-Section CRLH Antenna Loaded With Textile AMC for Wireless Body Area Network Applications

    by Mohamed El Atrash, Mahmoud A. Abdalla, Hadia M. Elhennawy

    An ultra-thin, compact, and highly efficient antenna based on the Π-section Composite Right/Left-Handed (CRLH) methodology is presented. It operates at 2.45 GHz of the ISM Band with a physical size of 25 mm × 25 mm, realized gain of 2.34 dBi and total efficiency of 87% in free space. Nevertheless, to maintain resonance at 2.45 GHz with body-loading scenarios, a high separation was required, leading to an overall large size. To circumvent that, an all-textile 2×2 Artificial Magnetic Conductor (AMC) array was placed in-between the antenna and human body. In free space, the low profile integrated design exhibited a gain of 7.63 dBi (enhancement of 5.29 dBi) and total efficiency of 96.4%. The integrated design achieved a gain and total efficiency enhancements by 14.88 dBi and 72.4%, respectively, as well as, lower Specific Absorption Rate (SAR) levels, in comparison to the CRLH antenna alone, for human loading cases. Results are achieved through circuit model and full wave electromagnetic simulations. In addition, the CRLH antenna and AMC array structure were fabricated and measurements were undertaken, which agreed well with the simulated ones. Therefore, the integrated design is highly suggested to be recognized in Wireless Body Area Network (WBAN) and medical applications.


  • A compact flexible textile artificial magnetic conductor-based wearable monopole antenna for low specific absorption rate wrist applications

    by Mohamed El Atrash, Mahmoud A. Abdalla, Hadia M. Elhennawy

    A compact monopole antenna backed with a 1 × 2 textile-based artificial magnetic conductor (AMC) array is proposed. Textile was mainly selected for the AMC materials according to an investigation that took place between different AMC substrate materials, where it was settled that the textile one displayed the highest antenna gain and efficiency. The monopole antenna and the AMC, distanced apart by 5 mm, combined form the integrated design. It operates at 2.4 GHz, which was particularly selected as the resonant frequency for wirelessly sending the subject's symptoms data via Wi-Fi, with realized gain and total efficiency of 6.76 dBi and 88.4%, respectively, in free space. Separated by 3 mm from the specific anthropomorphic mannequin human hand model, it displays a realized gain and total efficiency of 4.06 dBi and 44.39%, respectively, in a flat condition. Furthermore, it exhibits a specific absorption rate (SAR) of 1.8 W/kg averaged over 10 g of tissue. When bent over the human hand model, it performs well and exhibits a maximum SAR of 0.521 and 0.406 W/kg, averaged over 1 and 10 g of tissues, respectively. As a result of such outcomes, the proposed integrated design can be nominated for wearable hand/wrist and Wi-Fi applications.