XCXiao Cheng

Xiao Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao Cheng has a total of 1 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental Comparison of Flow Boiling Heat Transfer in High Aspect Ratio Microchannels With Plain and Grooved Walls

    by Xiao Cheng, Huiying Wu

    The dry-out easily occurs on high-aspect ratio microchannel sidewalls due to the decreasing of liquid film thickness. In this paper, the triangular microgrooves possessing the characteristic of evaporating meniscus were designed on the microchannel sidewalls. The heat sink consisted of 33 parallel microchannels, having a hydraulic diameter of 100 μm and an aspect ratio of 4. A platinum film heater and platinum resistance temperature detectors (RTDs) were integrated on the backside of the heat sink to realize uniform heating and precise temperature measurement, respectively. Flow boiling visualization experiments were carried out by high-speed camera in triangular groove-wall and plain-wall microchannels at mass fluxes of 148–490 kg/m2·s and inlet temperatures of 42 °C and 60 °C. The boiling curve, heat transfer coefficient (HTC), pressure drop, and two-phase flow boiling instability were systematically investigated to assess the flow boiling performances. Thin liquid film was observed in the triangular grooves during the dry-out process, compared to the dry-out in plain-wall microchannels. The oscillations of wall temperature, inlet temperature, and pressure drop were significantly suppressed in triangular groove-wall microchannels. Moreover, the earlier onset of nucleate boiling, improved heat flux, and HTC were realized in triangular groove-wall microchannels compared to plain-wall microchannels. Therefore, triangular groove design on the sidewalls is a promising solution to enhance boiling heat transfer and suppress flow boiling instabilities for high-aspect ratio microchannels.


  • Heat Transfer and Entropy Generation Analysis of Slit Pillar Array in Microchannels

    by Xiao Cheng, Huiying Wu

    The slit pillar allows a small fraction of the mainstream flow through pillar to disturb the pillar wake zone fluid and eventually enhance the local and global heat transfer performances in microchannels. In this study, three-dimensional full-domain numerical simulations on the hydrodynamic and thermal characteristics of slit pillar array in microchannels are performed. Effects of slit angle and height over diameter (H/D) ratio on the fluid flow and heat transfer are studied. Comparisons with the nonslit pillar array are conducted on pressure drop, surface temperature, Nusselt number, and thermal performance index (TPI). Furthermore, the results are analyzed by using the entropy generation. As a result of secondary flows and enhanced convective heat transfer area, all cases at H/D ratio of 0.3 demonstrate enhanced heat transfer performance at an increase of 18.0–34.7% on Nusselt number, while a reduction of 3.4–12.9% on pressure drop in comparison to the criterion case at the same conditions. Among them, slit 15–15 deg shows the best comprehensive heat transfer performance. Due to the improved uniformities of velocity and temperature distributions, all slit pillar array microchannels show decreased entropy generation. The maximum entropy generation reduction can reach up to 15.8%, as compared with the criterion case at the same conditions. The above results fully demonstrate that the novel slit pillar array microchannel heat sink can be used as an effective approach for heat transfer enhancement.


  • Heat Transfer Enhancement for Wake Zone Using Slit Pillar in Microchannel Heat Sinks

    by Xiao Cheng, Huiying Wu

    Pillar microchannel heat sinks have been widely used for chip cooling, while their overall heat transfer performance is restricted by the stagnation flow in pillar wake zone. In this work, a simple but effective method using slit microstructure modified on pillar was proposed to enhance wake zone heat transfer. It enables a special flow path for the incoming fluid that intensively disturbs the wake fluid. To validate the proposed method, a three-dimensional simulation was employed to study the laminar flow and heat transfer characteristics in the slit pillar microchannel. The pillar without slit design was also investigated for comparative analysis. Effects of slit angle (θ), height over diameter ratio (H/D), and blocking ratio (D/W) of a single pillar were systematically studied at the Reynolds numbers of 26–260. Results showed the case with θ = 0 deg always demonstrated lower surface temperature, higher Nusselt number and higher thermal performance index (TPI) compared to other cases with different slit angles at the same conditions. Furthermore, it was interesting to find that the slit configuration was not suitable for long pillar microchannel, but preferred for high blocking ratio pillar microchannel at present ranges (H/D ≤ 1, D/W ≤ 0.5). The slit pillar array microchannel was also explored and observed with improved overall heat transfer performance. The proposed slit microstructure well prevents the heat transfer deterioration in pillar wake zone, which is promisingly to be used for cooling performance improvement of electronic device.