Francesca Romana Parente
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francesca Romana Parente has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Ferri
Department of Industrial and Information Engineering and Economics, University of L’Aquila, 67100 L’Aquila, Italy
7 shared publications - Marco Santonico
Università Campus Bio-Medico di Roma, Rome, Italy
7 shared publications - Vincenzo Stornelli
Department of Industrial and Information Engineering and Economics, University of L’Aquila, 67100 L’Aquila, Italy
7 shared publications - Giorgio Pennazza
Department of Engineering, Unit of Electronics for Sensor Systems, Universit Campus Bio-Medico di Roma, Rome, Italy
6 shared publications - Alessandro Zompanti
Department of Engineering, Unit of Electronics for Sensor Systems, Universit Campus Bio-Medico di Roma, Rome, Italy
4 shared publications - Simone Grasso
Unit of Electronic for Sensor Systems, Department of Sciences and Technologies for Sustainable Development and One Health, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy
3 shared publications
Latest Publications
- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (1) , 31-36
Design and Development of an Electronic Interface for Gas Detection and Exhaled Breath Analysis in Liquids
Among gas sensors, the ones measuring carbon dioxide and oxygen are crucial for many application fields: the monitoring of air quality, the control of food packaging processes, the study of biochemical mechanisms, and specific reactions related to many different studies in the biomedical context. Many of the sensors used for the measure of carbon dioxide (CO2) and oxygen (O2) are based on electrochemical, optical, and conductometric working principles, which allow to cover the very different ranges of concentration which represent the target of each different field or specific application with good reproducibility and sensitivity. This paper presents a voltammetric sensor showing an innovative approach for the measure of gas and vapors by the interaction of a screen-printed electrode system with the liquid solution, where the gases are conveyed. The design and realization of this sensor system are reported. Calibration tests with CO2 and O2 have given acceptable reproducibility and sensitivity. Besides, this paper shows that new results have been obtained by analyzing exhaled breath collected by control individuals.
- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (1) , 31-36
Design and Development of an Electronic Interface for Gas Detection and Exhaled Breath Analysis in Liquids
Among gas sensors, the ones measuring carbon dioxide and oxygen are crucial for many application fields: the monitoring of air quality, the control of food packaging processes, the study of biochemical mechanisms, and specific reactions related to many different studies in the biomedical context. Many of the sensors used for the measure of carbon dioxide (CO2) and oxygen (O2) are based on electrochemical, optical, and conductometric working principles, which allow to cover the very different ranges of concentration which represent the target of each different field or specific application with good reproducibility and sensitivity. This paper presents a voltammetric sensor showing an innovative approach for the measure of gas and vapors by the interaction of a screen-printed electrode system with the liquid solution, where the gases are conveyed. The design and realization of this sensor system are reported. Calibration tests with CO2 and O2 have given acceptable reproducibility and sensitivity. Besides, this paper shows that new results have been obtained by analyzing exhaled breath collected by control individuals.
- Open Access
An Electronic System for the Contactless Reading of ECG Signals
The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.
Open AccessAn Electronic System for the Contactless Reading of ECG Signals
The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.
- 27 October 2017
- Published by Springer Nature
- p. 289-294
An Electrode Impedance Balanced Interface for Biomedical Application
- 27 October 2017
- Published by Springer Nature
- p. 289-294
An Electrode Impedance Balanced Interface for Biomedical Application
- 27 October 2017
- Published by Springer Nature
- p. 179-183
Breath-Printing of Heart Failure in Elderly
- Open Access
- 29 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 592
Linear Integrated Interface for Automatic Differential Capacitive Sensing
In this work, the authors introduce a new full-analog front-end for differential capacitance sensors which provides a DC output voltage, directly proportional to the measurand variations. The readout circuit architecture is based on a De Sauty bridge as core of the capacitive sensing whereas the feedback circuitry performs the bridge autobalancing operation by means of changes in a multiplier output. The circuit is designed in a standard CMOS technology (AMS 0.35 µm) so is suitable for portable systems. Simulated results have shown a good agreement with the theoretical model being the percentage relative error less than 2.5%. Interface sensitivity is constant and values around 0.055 V/mm for the considered application.
- 29 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 592
Open AccessLinear Integrated Interface for Automatic Differential Capacitive Sensing
In this work, the authors introduce a new full-analog front-end for differential capacitance sensors which provides a DC output voltage, directly proportional to the measurand variations. The readout circuit architecture is based on a De Sauty bridge as core of the capacitive sensing whereas the feedback circuitry performs the bridge autobalancing operation by means of changes in a multiplier output. The circuit is designed in a standard CMOS technology (AMS 0.35 µm) so is suitable for portable systems. Simulated results have shown a good agreement with the theoretical model being the percentage relative error less than 2.5%. Interface sensitivity is constant and values around 0.055 V/mm for the considered application.
- Open Access
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 447
A Gas Sensor Device for Oxygen and Carbon Dioxide Detection
Sensors for monitoring oxygen and carbon dioxide are crucial as investigational devices in many different research fields, including environmental, biomedical and industrial. They must be easily configurable, fast responding, and with good reproducibility and sensitivity. The state of art reports different sensing and transducing strategies: electrochemical, optical, conductometric etc., based on specific chemically interactive materials. In this work, a multisensor system based on electrochemical sensors acting via a liquid medium and controlled by a dedicated low-noise electronic interface is equipped with an elaboration unit able in extracting/storing a committed model for oxygen and carbon dioxide detection.
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 447
Open AccessA Gas Sensor Device for Oxygen and Carbon Dioxide Detection
Sensors for monitoring oxygen and carbon dioxide are crucial as investigational devices in many different research fields, including environmental, biomedical and industrial. They must be easily configurable, fast responding, and with good reproducibility and sensitivity. The state of art reports different sensing and transducing strategies: electrochemical, optical, conductometric etc., based on specific chemically interactive materials. In this work, a multisensor system based on electrochemical sensors acting via a liquid medium and controlled by a dedicated low-noise electronic interface is equipped with an elaboration unit able in extracting/storing a committed model for oxygen and carbon dioxide detection.
- 20 June 2017
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 37 (3) , 1315-1326
CCII-Based Voltage Amplifier Optimization for Reduced Relative Gain Error
- 20 June 2017
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 37 (3) , 1315-1326
CCII-Based Voltage Amplifier Optimization for Reduced Relative Gain Error
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 281-284
A standard CMOS bridge-based analog interface for differential capacitive sensors
This work describes an analog electronic interface, based on a modified De Sauty AC bridge, performing a differential capacitive sensor estimation. A suitable feedback loop tunes a Voltage Controlled Resistor to balance the bridge. The electronic circuit has been designed in a standard integrated CMOS technology (AMS 0.35μm) with a low supply voltage (±1.5 V) and a reduced power consumption (lower than 4mW). PSpice simulation results show a very good agreement with theoretical expectations. The output voltage accuracy shows a 0.03V maximum absolute error for a range of ±50% of sensor variations from its baseline value. Very small baseline values are allowed (tens of μF).
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 281-284
A standard CMOS bridge-based analog interface for differential capacitive sensors
This work describes an analog electronic interface, based on a modified De Sauty AC bridge, performing a differential capacitive sensor estimation. A suitable feedback loop tunes a Voltage Controlled Resistor to balance the bridge. The electronic circuit has been designed in a standard integrated CMOS technology (AMS 0.35μm) with a low supply voltage (±1.5 V) and a reduced power consumption (lower than 4mW). PSpice simulation results show a very good agreement with theoretical expectations. The output voltage accuracy shows a 0.03V maximum absolute error for a range of ±50% of sensor variations from its baseline value. Very small baseline values are allowed (tens of μF).
- Open Access
Unmasking of Olive Oil Adulteration Via a Multi-Sensor Platform
Methods for the chemical and sensorial evaluation of olive oil are frequently changed and tuned to oppose the increasingly sophisticated frauds. Although a plethora of promising alternatives has been developed, chromatographic techniques remain the more reliable yet, even at the expense of their related execution time and costs. In perspective of a continuous increment in the number of the analyses as a result of the global market, more rapid and effective methods to guarantee the safety of the olive oil trade are required. In this study, a novel artificial sensorial system, based on gas and liquid analysis, has been employed to deal with olive oil genuineness and authenticity issues. Despite these sensors having been widely used in the field of food science, the innovative electronic interface of the device is able to provide a higher reproducibility and sensitivity of the analysis. The multi-parametric platform demonstrated the capability to evaluate the organoleptic properties of extra-virgin olive oils as well as to highlight the presence of adulterants at blending concentrations usually not detectable through other methods.
Open AccessUnmasking of Olive Oil Adulteration Via a Multi-Sensor Platform
Methods for the chemical and sensorial evaluation of olive oil are frequently changed and tuned to oppose the increasingly sophisticated frauds. Although a plethora of promising alternatives has been developed, chromatographic techniques remain the more reliable yet, even at the expense of their related execution time and costs. In perspective of a continuous increment in the number of the analyses as a result of the global market, more rapid and effective methods to guarantee the safety of the olive oil trade are required. In this study, a novel artificial sensorial system, based on gas and liquid analysis, has been employed to deal with olive oil genuineness and authenticity issues. Despite these sensors having been widely used in the field of food science, the innovative electronic interface of the device is able to provide a higher reproducibility and sensitivity of the analysis. The multi-parametric platform demonstrated the capability to evaluate the organoleptic properties of extra-virgin olive oils as well as to highlight the presence of adulterants at blending concentrations usually not detectable through other methods.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
A simplified architecture for differential capacitance sensors
This paper describes a simple approach to perform differential capacitance measurements by the design and characterization of a dedicated electronic circuit. Capacitance transducers provide information about changes in capacitance in response to a physical variation. They are used in many types of applications such as linear displacement sensors, pressure transducers and accelerometers. The operating principle of the interface circuit is discussed. The proposed electronic circuit is designed and simulated by PSPICE software. Theoretical analysis and simulated results are analyzed.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
A simplified architecture for differential capacitance sensors
This paper describes a simple approach to perform differential capacitance measurements by the design and characterization of a dedicated electronic circuit. Capacitance transducers provide information about changes in capacitance in response to a physical variation. They are used in many types of applications such as linear displacement sensors, pressure transducers and accelerometers. The operating principle of the interface circuit is discussed. The proposed electronic circuit is designed and simulated by PSPICE software. Theoretical analysis and simulated results are analyzed.