Ágnes Orbán
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ágnes Orbán has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Adam Butykai
Department of Physics, Budapest University of Technology and Economics, Budapest, Hungary
2 shared publications- Adam Butykai
Department of Physics, Budapest University of Technology and Economics, Budapest, Hungary
2 shared publications István Kézsmárki
Department of Physics, Budapest University of Technology and Economics, Budapest, Hungary
2 shared publicationsIvo Mueller
Population Health and Immunity Division, Walter and Eliza Hall Institute of Medical Research, Melbourne, Australia
2 shared publicationsJetsumon Sattabongkot
Mahidol Vivax Research Unit, Mahidol University, Bangkok, Thailand
2 shared publicationsNongnuj Maneechai
Mahidol Vivax Research Unit, Mahidol University, Bangkok, Thailand
2 shared publications
Latest Publications
- Open Access
- 17 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Sensitive detection of Plasmodium vivax malaria by the rotating-crystal magneto-optical method in Thailand
The rotating-crystal magneto-optical detection (RMOD) method has been developed for the rapid and quantitative diagnosis of malaria and tested systematically on various malaria infection models. Very recently, an extended field trial in a high-transmission region of Papua New Guinea demonstrated its great potential for detecting malaria infections, in particular Plasmodium vivax. In the present small-scale field test, carried out in a low-transmission area of Thailand, RMOD confirmed malaria in all samples found to be infected with Plasmodium vivax by microscopy, our reference method. Moreover, the magneto-optical signal for this sample set was typically 1–3 orders of magnitude higher than the cut-off value of RMOD determined on uninfected samples. Based on the serial dilution of the original patient samples, we expect that the method can detect Plasmodium vivax malaria in blood samples with parasite densities as low as $$\sim$$ 5–10 parasites per microliter, a limit around the pyrogenic threshold of the infection. In addition, by investigating the correlation between the magnitude of the magneto-optical signal, the parasite density and the erythrocytic stage distribution, we estimate the relative hemozoin production rates of the ring and the trophozoite stages of in vivo Plasmodium vivax infections.- 17 September 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-8
Open AccessSensitive detection of Plasmodium vivax malaria by the rotating-crystal magneto-optical method in Thailand
The rotating-crystal magneto-optical detection (RMOD) method has been developed for the rapid and quantitative diagnosis of malaria and tested systematically on various malaria infection models. Very recently, an extended field trial in a high-transmission region of Papua New Guinea demonstrated its great potential for detecting malaria infections, in particular Plasmodium vivax. In the present small-scale field test, carried out in a low-transmission area of Thailand, RMOD confirmed malaria in all samples found to be infected with Plasmodium vivax by microscopy, our reference method. Moreover, the magneto-optical signal for this sample set was typically 1–3 orders of magnitude higher than the cut-off value of RMOD determined on uninfected samples. Based on the serial dilution of the original patient samples, we expect that the method can detect Plasmodium vivax malaria in blood samples with parasite densities as low as $$\sim$$ 5–10 parasites per microliter, a limit around the pyrogenic threshold of the infection. In addition, by investigating the correlation between the magnitude of the magneto-optical signal, the parasite density and the erythrocytic stage distribution, we estimate the relative hemozoin production rates of the ring and the trophozoite stages of in vivo Plasmodium vivax infections. - Open Access
Sensitive detection of Plasmodium vivax malaria by the rotating-crystal magneto-optical method in Thailand
The rotating-crystal magneto-optical detection (RMOD) method has been developed for the rapid and quantitative diagnosis of malaria and tested systematically on various malaria infection models. Very recently, an extended field trial in a high-transmission region of Papua New Guinea demonstrated its great potential for detecting malaria infections, in particular Plasmodium vivax . In the present small-scale field test, carried out in a low-transmission area of Thailand, RMOD confirmed malaria in all samples found to be infected with Plasmodium vivax by microscopy, our reference method. Moreover, the magneto-optical signal for this sample set was typically 1–3 orders of magnitude higher than the cut-off value of RMOD determined on uninfected samples. Based on the serial dilution of the original patient samples, we expect that the method can detect Plasmodium vivax malaria in blood samples with parasite densities as low as ∼ 5 − 10 parasites per microliter, a limit around the pyrogenic threshold of the infection. In addition, by investigating the correlation between the magnitude of the magneto-optical signal, the parasite density and the erythrocytic stage distribution, we estimate the relative hemozoin production rates of the ring and the trophozoite stages of in vivo Plasmodium vivax infections.
Open AccessSensitive detection of Plasmodium vivax malaria by the rotating-crystal magneto-optical method in Thailand
The rotating-crystal magneto-optical detection (RMOD) method has been developed for the rapid and quantitative diagnosis of malaria and tested systematically on various malaria infection models. Very recently, an extended field trial in a high-transmission region of Papua New Guinea demonstrated its great potential for detecting malaria infections, in particular Plasmodium vivax . In the present small-scale field test, carried out in a low-transmission area of Thailand, RMOD confirmed malaria in all samples found to be infected with Plasmodium vivax by microscopy, our reference method. Moreover, the magneto-optical signal for this sample set was typically 1–3 orders of magnitude higher than the cut-off value of RMOD determined on uninfected samples. Based on the serial dilution of the original patient samples, we expect that the method can detect Plasmodium vivax malaria in blood samples with parasite densities as low as ∼ 5 − 10 parasites per microliter, a limit around the pyrogenic threshold of the infection. In addition, by investigating the correlation between the magnitude of the magneto-optical signal, the parasite density and the erythrocytic stage distribution, we estimate the relative hemozoin production rates of the ring and the trophozoite stages of in vivo Plasmodium vivax infections.
- Open Access
Magneto-optical diagnosis of symptomatic malaria in Papua New Guinea
Improved methods for malaria diagnosis are urgently needed. Here, we tested a novel rotating-crystal magneto-optical diagnostic (RMOD) test in 964 suspected malaria patients in Papua New Guinea. RMOD tests can be obtained within minutes and at low cost. Capillary blood samples were also subjected to rapid diagnostic tests, expert light microscopy and polymerase chain reaction to systematically evaluate the capability of RMOD to detect infections. Compared to light microscopy, as the gold standard, RMOD exhibited 82% sensitivity and 84% specificity to detect any malaria infection. This increased to 87% sensitivity and 88% specificity for Plasmodium vivax , indicating that RMOD could be useful in P. vivax dominated elimination settings. Parasite density correlated well with the quantitative magneto-optical signal. Importantly, residual hemozoin present in malaria negative patients was also detectable by RMOD, indicating its ability to detect previous infections, which can be exploited to reveal transmission hotspots in low-transmission settings.
Open AccessMagneto-optical diagnosis of symptomatic malaria in Papua New Guinea
Improved methods for malaria diagnosis are urgently needed. Here, we tested a novel rotating-crystal magneto-optical diagnostic (RMOD) test in 964 suspected malaria patients in Papua New Guinea. RMOD tests can be obtained within minutes and at low cost. Capillary blood samples were also subjected to rapid diagnostic tests, expert light microscopy and polymerase chain reaction to systematically evaluate the capability of RMOD to detect infections. Compared to light microscopy, as the gold standard, RMOD exhibited 82% sensitivity and 84% specificity to detect any malaria infection. This increased to 87% sensitivity and 88% specificity for Plasmodium vivax , indicating that RMOD could be useful in P. vivax dominated elimination settings. Parasite density correlated well with the quantitative magneto-optical signal. Importantly, residual hemozoin present in malaria negative patients was also detectable by RMOD, indicating its ability to detect previous infections, which can be exploited to reveal transmission hotspots in low-transmission settings.
- Open Access
- 7 October 2019
- Published by MDPI AG in Biomolecules
- Vol. 9 (10) , 579
Highly Sensitive and Rapid Characterization of the Development of Synchronized Blood Stage Malaria Parasites Via Magneto-Optical Hemozoin Quantification
The rotating-crystal magneto-optical diagnostic (RMOD) technique was developed as a sensitive and rapid platform for malaria diagnosis. Herein, we report a detailed in vivo assessment of the synchronized Plasmodium vinckei lentum strain blood-stage infections by the RMOD method and comparing the results to the unsynchronized Plasmodium yoelii 17X-NL (non-lethal) infections. Furthermore, we assess the hemozoin production and clearance dynamics in chloroquine-treated compared to untreated self-resolving infections by RMOD. The findings of the study suggest that the RMOD signal is directly proportional to the hemozoin content and closely follows the actual parasitemia level. The lack of long-term accumulation of hemozoin in peripheral blood implies a dynamic equilibrium between the hemozoin production rate of the parasites and the immune system’s clearing mechanism. Using parasites with synchronous blood stage cycle, which resemble human malaria parasite infections with Plasmodium falciparum and Plasmodium vivax, we are demonstrating that the RMOD detects both hemozoin production and clearance rates with high sensitivity and temporal resolution. Thus, RMOD technique offers a quantitative tool to follow the maturation of the malaria parasites even on sub-cycle timescales.
- 7 October 2019
- Published by MDPI AG in Biomolecules
- Vol. 9 (10) , 579
Open AccessHighly Sensitive and Rapid Characterization of the Development of Synchronized Blood Stage Malaria Parasites Via Magneto-Optical Hemozoin Quantification
The rotating-crystal magneto-optical diagnostic (RMOD) technique was developed as a sensitive and rapid platform for malaria diagnosis. Herein, we report a detailed in vivo assessment of the synchronized Plasmodium vinckei lentum strain blood-stage infections by the RMOD method and comparing the results to the unsynchronized Plasmodium yoelii 17X-NL (non-lethal) infections. Furthermore, we assess the hemozoin production and clearance dynamics in chloroquine-treated compared to untreated self-resolving infections by RMOD. The findings of the study suggest that the RMOD signal is directly proportional to the hemozoin content and closely follows the actual parasitemia level. The lack of long-term accumulation of hemozoin in peripheral blood implies a dynamic equilibrium between the hemozoin production rate of the parasites and the immune system’s clearing mechanism. Using parasites with synchronous blood stage cycle, which resemble human malaria parasite infections with Plasmodium falciparum and Plasmodium vivax, we are demonstrating that the RMOD detects both hemozoin production and clearance rates with high sensitivity and temporal resolution. Thus, RMOD technique offers a quantitative tool to follow the maturation of the malaria parasites even on sub-cycle timescales.
- Open Access
Efficient monitoring of blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method
Global research efforts have been focused on the simultaneous improvement of the efficiency and sensitivity of malaria diagnosis in resource-limited settings and for the active case detection of asymptomatic infections. A recently developed magneto-optical (MO) method allows the high-sensitivity detection of malaria pigment (hemozoin) crystals in blood via their magnetically induced rotational motion. The evaluation of the method using synthetic $\beta$-hematin crystals and P. falciparum in vitro cultures implies its potential for in-field diagnosis. Here, we study the performance of the method in monitoring the in vivo onset and progression of the blood stage infection using a malaria mouse model. We found that the MO method can detect the first generation of intraerythrocytic parasites at the ring stage 61-66 hours after sporozoite injection demonstrating better sensitivity than light microscopy and flow cytometry. MO measurements performed after treatment of severe P. berghei infections show that the clearance period of hemozoin in mice is approx. 5 days which indicates the feasibility of the detection of later reinfections as well. Being label and reagent-free, cost-effective and rapid, together with the demonstrated sensitivity, we believe that the MO method is a suitable candidate for in-depth clinical evaluation in endemic settings.
Open AccessEfficient monitoring of blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method
Global research efforts have been focused on the simultaneous improvement of the efficiency and sensitivity of malaria diagnosis in resource-limited settings and for the active case detection of asymptomatic infections. A recently developed magneto-optical (MO) method allows the high-sensitivity detection of malaria pigment (hemozoin) crystals in blood via their magnetically induced rotational motion. The evaluation of the method using synthetic $\beta$-hematin crystals and P. falciparum in vitro cultures implies its potential for in-field diagnosis. Here, we study the performance of the method in monitoring the in vivo onset and progression of the blood stage infection using a malaria mouse model. We found that the MO method can detect the first generation of intraerythrocytic parasites at the ring stage 61-66 hours after sporozoite injection demonstrating better sensitivity than light microscopy and flow cytometry. MO measurements performed after treatment of severe P. berghei infections show that the clearance period of hemozoin in mice is approx. 5 days which indicates the feasibility of the detection of later reinfections as well. Being label and reagent-free, cost-effective and rapid, together with the demonstrated sensitivity, we believe that the MO method is a suitable candidate for in-depth clinical evaluation in endemic settings.