QWQin Wang

Qin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qin Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multicontrol: Advanced Control-Logic Synthesis for Flow-Based Microfluidic Biochips

    by Ying Zhu, Xing Huang, Bing Li, Tsung-Yi Ho, Qin Wang, Hailong Yao, Robert Wille, Ulf Schlichtmann

    Flow-based microfluidic biochips are one of the most promising platforms used in biochemical and pharmaceutical laboratories due to their high efficiency and low costs. Inside such a chip, fluids of nanoliter volumes are transported between devices for various operations such as mixing and detection. The transportation channels and corresponding operation devices are controlled by microvalves driven by external pressure sources. Since assigning an independent pressure source to every microvalve would be impractical due to high costs and limited system dimensions, states of microvalves are switched by a control logic using time multiplexing. Existing control logic designs, however, still switch only a single control channel per operation, leading to a low efficiency. In this paper, we present the first automatic synthesis approach for a control logic that is able to switch multiple control channels simultaneously. Moreover, we propose the first fault-aware design in control logic by introducing backup control paths to maintain the correct function even when manufacturing defects occur. The construction of control logic is achieved by a highly efficient framework based on Particle Swarm Optimization, Boolean logic simplification, grid routing, together with mixing multiplexing. Simulation results demonstrate that the proposed multi-channel switching mechanism leads to fewer valve-switching times and lower total logic cost, while realizing fault tolerance for all control channels.


  • Integrated Control-Fluidic Codesign Methodology for Paper-Based Digital Microfluidic Biochips

    by Qin Wang, Weiqing Ji, Zeyan Li, Haena Cheong, Oh-Sun Kwon, Hailong Yao, Tsung-Yi Ho, Kwanwoo Shin, Bing Li, Ulf Schlichtmann, et al.

    Paper-based digital microfluidic biochips (P-DMFBs) have recently emerged as a promising low-cost and fast-responsive platform for biochemical assays. In P-DMFBs, electrodes and control lines are printed on a piece of photo paper using an inkjet printer and carbon nanotubes (CNTs) conductive ink. Compared with traditional digital microfluidic biochips (DMFBs), P-DMFBs enjoy significant advantages, such as faster in-place fabrication with printer and ink, lower costs, and better disposability. Since electrodes and CNT control lines are printed on the same side of the paper, a critical design challenge for P-DMFB is to prevent control interference between moving droplets and the voltages on CNT control lines. Control interference may result in unexpected droplet movements and thus incorrect assay outputs. To address this design challenge, a control-fluidic codesign methodology is proposed in this paper, along with two demonstrative design flows integrating both fluidic design and control design, i.e., the droplet-oriented codesign flow and the electrode-oriented codesign flow. The droplet-oriented flow is suitable for designing biochips with sparse electrodes and relatively larger number of droplets, whereas the electrode-oriented flow is suitable for biochips with dense electrodes and smaller number of droplets. The computational simulation results of real-life bioassays demonstrate the effectiveness of the proposed codesign flows.


  • Pressure-Aware Control Layer Optimization for Flow-Based Microfluidic Biochips

    by Qin Wang, Yue Xu, Shiliang Zuo, Hailong Yao, Tsung-Yi Ho, Bing Li, Ulf Schlichtmann, Yici Cai

    Flow-based microfluidic biochips are attracting increasing attention with successful biomedical applications. One critical issue with flow-based microfluidic biochips is the large number of microvalves that require peripheral control pins. Even using the broadcasting addressing scheme, i.e., one control pin controls multiple microvalves simultaneously, thousands of microvalves would still require hundreds of control prins, which is unrealistic. To address this critical challenge in control scalability, the control-layer multiplexer is introduced to effectively reduce the number of control pins into log scale of the number of microvalves. There are two practical design issues with the control-layer multiplexer: (1) the reliability issue caused by the frequent control-valve switching, and (2) the pressure degradation problem caused by the control-valve switching without pressure refreshing from the pressure source. This paper addresses these two design issues by the proposed Hamming-distance-based switching sequence optimization method and the XOR-based pressure refreshing method. Simulation results demonstrate the effectiveness and efficiency of the proposed methods with an average 77.2% (maximum 89.6%) improvement in total pressure refreshing cost, and an average 88.5% (maximum 90.0%) improvement in pressure deviation.


  • Physical Co-Design of Flow and Control Layers for Flow-Based Microfluidic Biochips

    by Qin Wang, Hao Zou, Hailong Yao, Tsung-Yi Ho, Robert Wille, Yici Cai

    Flow-based microfluidic biochips are attracting increasing attention with successful applications in biochemical experiments, point-of-care diagnosis, etc. Existing works in design automation consider the flow-layer design and control-layer design separately, lacking a global optimization and hence resulting in degraded routability and reliability. This paper presents a novel integrated physical co-design methodology, which seamlessly integrates the flow-layer and control-layer design stages. In the flow-layer design stage, a sequence-pair-based placement method is presented, which allows for an iterative placement refinement based on routing feedbacks. In the control-layer design stage, the minimum cost flow formulation is adopted to further improve the routability. Besides that, effective placement adjustment strategies are proposed to iteratively enhance the solution quality of the overall control-layer design. Experimental results show that compared with the existing work, the proposed design flow obtains an average reduction of 40.44% in flow-channel crossings, 31.95% in total chip area, and 22.02% in total flow-channel length. Moreover, all the valves are successfully routed in the control-layer design stage.