Li Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Li Qiu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Zhenhua Li
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China
3 shared publications - Changzheng Deng
College of Electrical Engineering and New Energy, China Three Gorges University, 26476 Yichang, Hubei China
2 shared publications - Qi Xiong
College of Electrical Engineering & New Energy, China Three Gorges University, Yichang 443002, China
2 shared publications - Ahmed Abu-Siada
School of Electrical Engineering, Computing and Mathematical Sciences, Curtin University, Perth, WA 6102, Australia
1 shared publication - Hongbin Li
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Jie Yu
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang China
1 shared publication
Latest Publications
- 25 October 2024
- Published by Springer Nature in Archives of Civil and Mechanical Engineering
- Vol. 25 (1) , 1-16
Electromagnetic driven forming utilizing a metal ring for controlling shapes of sheet metals
- 25 October 2024
- Published by Springer Nature in Archives of Civil and Mechanical Engineering
- Vol. 25 (1) , 1-16
Electromagnetic driven forming utilizing a metal ring for controlling shapes of sheet metals
- Open Access
- 19 June 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (6) , 269
A Predictive Model for Voltage Transformer Ratio Error Considering Load Variations
The accuracy of voltage transformer (VT) measurements is imperative for the security and reliability of power systems and the equitability of energy transactions. The integration of a substantial number of electric vehicles (EVs) and their charging infrastructures into the grid poses new challenges for VT measurement fidelity, including voltage instabilities and harmonic disruptions. This paper introduces an innovative transformer measurement error prediction model that synthesizes Multivariate Variational Mode Decomposition (MVMD) with a deep learning framework integrating Bidirectional Temporal Convolutional Network and Multi-Head Attention mechanism (BiTCN-MHA). The paper is aimed at enhancing VT measurement accuracy under fluctuating load conditions. Initially, the optimization of parameter selection within the MVMD algorithm enhances the accuracy and interpretability of bi-channel signal decomposition. Subsequently, the model applies the Spearman rank correlation coefficient to extract dominant modal components from both the decomposed load and original ratio error sequences to form the basis for input signal channels in the BiTCN-MHA model. By superimposing predictive components, an effective prediction of future VT measurement error trends can be achieved. This comprehensive approach, accounting for input load correlations and temporal dynamics, facilitates robust predictions of future VT measurement error trends. Computational example analysis of empirical operational VT data shows that, compared to before decomposition, the proposed method reduces the Root-Mean-Square Error (RMSE) by 17.9% and the Mean Absolute Error (MAE) by 23.2%, confirming the method’s robustness and superiority in accurately forecasting VT measurement error trends.
- 19 June 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (6) , 269
Open AccessA Predictive Model for Voltage Transformer Ratio Error Considering Load Variations
The accuracy of voltage transformer (VT) measurements is imperative for the security and reliability of power systems and the equitability of energy transactions. The integration of a substantial number of electric vehicles (EVs) and their charging infrastructures into the grid poses new challenges for VT measurement fidelity, including voltage instabilities and harmonic disruptions. This paper introduces an innovative transformer measurement error prediction model that synthesizes Multivariate Variational Mode Decomposition (MVMD) with a deep learning framework integrating Bidirectional Temporal Convolutional Network and Multi-Head Attention mechanism (BiTCN-MHA). The paper is aimed at enhancing VT measurement accuracy under fluctuating load conditions. Initially, the optimization of parameter selection within the MVMD algorithm enhances the accuracy and interpretability of bi-channel signal decomposition. Subsequently, the model applies the Spearman rank correlation coefficient to extract dominant modal components from both the decomposed load and original ratio error sequences to form the basis for input signal channels in the BiTCN-MHA model. By superimposing predictive components, an effective prediction of future VT measurement error trends can be achieved. This comprehensive approach, accounting for input load correlations and temporal dynamics, facilitates robust predictions of future VT measurement error trends. Computational example analysis of empirical operational VT data shows that, compared to before decomposition, the proposed method reduces the Root-Mean-Square Error (RMSE) by 17.9% and the Mean Absolute Error (MAE) by 23.2%, confirming the method’s robustness and superiority in accurately forecasting VT measurement error trends.
- 4 November 2020
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 13 (6) , 823-832
Research Situation Analysis of On-line Detection Technology for Power Transformer Winding Deformation
Background: Winding deformation is one of the most common faults in power transformers, which seriously threatens the safe operation of transformers. In order to discover the hidden trouble of transformer in time, it is of great significance to actively carry out the research of transformer winding deformation detection technology. Methods: In this paper, several methods of winding deformation detection with on-line detection prospects are summarized. The principles and characteristics of each method are analyzed, and the advantages and disadvantages of each method as well as the future research directions are expounded. Finally, aiming at the existing problems, the development direction of detection method for winding deformation in the future is prospected. Results: The on-line frequency response analysis method is still immature, and the vibration detection method is still in the theoretical research stage. Conclusion: The ΔV − I1 locus method provides a new direction for on-line detection of transformer winding deformation faults, which has certain application prospects and practical engineering value.
- 4 November 2020
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 13 (6) , 823-832
Research Situation Analysis of On-line Detection Technology for Power Transformer Winding Deformation
Background: Winding deformation is one of the most common faults in power transformers, which seriously threatens the safe operation of transformers. In order to discover the hidden trouble of transformer in time, it is of great significance to actively carry out the research of transformer winding deformation detection technology. Methods: In this paper, several methods of winding deformation detection with on-line detection prospects are summarized. The principles and characteristics of each method are analyzed, and the advantages and disadvantages of each method as well as the future research directions are expounded. Finally, aiming at the existing problems, the development direction of detection method for winding deformation in the future is prospected. Results: The on-line frequency response analysis method is still immature, and the vibration detection method is still in the theoretical research stage. Conclusion: The ΔV − I1 locus method provides a new direction for on-line detection of transformer winding deformation faults, which has certain application prospects and practical engineering value.
- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Research on Magnetic Field Measurement System Based on Distributed Magnetic Field Sensing and Numerical Integration Method
Magnetic field measurement is one of the key contents in the field of electromagnetic protection. In this paper, a magnetic field measurement system based on distributed magnetic sensing and high accuracy numerical integration method is proposed. And a magnetic field sensor with simple structure, small size and wide measurement band is designed, which includes three magnetic field measurement coils that can realize the accurate measurement of 3D magnetic field. The output of the magnetic field measurement coil is a differential signal that needs to be reduced by the integrator. To solve the problems of traditional analog integrator and common digital integrator, this paper proposes a high-precision digital integral algorithm based on gauss algorithm, which can effectively improve the accuracy of the integrator. Test results indicate that the error of the magnetic field measurement system is less than 5% in the range of 0.05T~5T.
- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Research on Magnetic Field Measurement System Based on Distributed Magnetic Field Sensing and Numerical Integration Method
Magnetic field measurement is one of the key contents in the field of electromagnetic protection. In this paper, a magnetic field measurement system based on distributed magnetic sensing and high accuracy numerical integration method is proposed. And a magnetic field sensor with simple structure, small size and wide measurement band is designed, which includes three magnetic field measurement coils that can realize the accurate measurement of 3D magnetic field. The output of the magnetic field measurement coil is a differential signal that needs to be reduced by the integrator. To solve the problems of traditional analog integrator and common digital integrator, this paper proposes a high-precision digital integral algorithm based on gauss algorithm, which can effectively improve the accuracy of the integrator. Test results indicate that the error of the magnetic field measurement system is less than 5% in the range of 0.05T~5T.
- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Analysis of Electromagnetic Force and Deformation Behavior in Electromagnetic Tube Expansion With Concave Coil Based on Finite Element Method
At present, the cylindrical coil is used to generate the electromagnetic force in electromagnetic tube expansion process. The obtained radial electromagnetic force in the end of the tube is less than the one in the middle of the tube for the end effects. Hence, the tube deformation is inhomogeneous in the axial direction. This paper presents a method named electromagnetic tube expansion with a concave coil to obtain more homogeneous deformation. By using COMSOL software, it gives the simulations for the effect of the geometry parameters of the concave coil on the distribution of the radial electromagnetic force and deformation behavior for the given AA6063-T6 tube. Simulations show that the concave coil with suitable parameters can obtain the homogeneous deformation. Furthermore, the homogeneous deformation range obtained by the concave coil is 36 mm which is better than the obtained range by the cylindrical coil.
- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Analysis of Electromagnetic Force and Deformation Behavior in Electromagnetic Tube Expansion With Concave Coil Based on Finite Element Method
At present, the cylindrical coil is used to generate the electromagnetic force in electromagnetic tube expansion process. The obtained radial electromagnetic force in the end of the tube is less than the one in the middle of the tube for the end effects. Hence, the tube deformation is inhomogeneous in the axial direction. This paper presents a method named electromagnetic tube expansion with a concave coil to obtain more homogeneous deformation. By using COMSOL software, it gives the simulations for the effect of the geometry parameters of the concave coil on the distribution of the radial electromagnetic force and deformation behavior for the given AA6063-T6 tube. Simulations show that the concave coil with suitable parameters can obtain the homogeneous deformation. Furthermore, the homogeneous deformation range obtained by the concave coil is 36 mm which is better than the obtained range by the cylindrical coil.