CFCéline Falentin-Daudré

Céline Falentin-Daudré

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Céline Falentin-Daudré has a total of 93 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fibronectin-Assisted Coating of Low-Molecular-Weight Fucoidan Creates a Biomimetic Interface for Endothelialization of Cobalt-Chromium Stents

    by Mehdi Saadi, Raymond Haddad, Nour Zeaiter, Oualid Haddad, Divya Prabhakar Reddy, Jean Sébastien Baumann, Fahima Irki, Jessica Bamba-Funck, Angela Sutton, Céline Falentin-Daudré, et al.

    Incomplete or delayed endothelialization after stent implantation compromises vascular healing and increases the risk of restenosis and late thrombosis. To address this limitation, Cobalt-Chromium (Co-Cr) stents were modified with a biomimetic coating combining Low-Molecular-Weight Fucoidan (LMWF), a sulfated polysaccharide with glycocalyx-mimetic properties, and fibronectin, to promote endothelial repair while preserving vascular homeostasis. The morphology, chemical composition, wettability and stability of the coating were characterized using complementary physicochemical approaches. The behavior of human endothelial cells cultured on this dual fibronectin-LMWF-coated stent was then assessed. Our results showed that fibronectin-LMWF-based coating achieved a ten-fold higher surface density on the stent than LMWF alone (0.29 ± 0.04 vs 0.03 ± 0.01 µg/mm 2 ) and retained 0.27 ± 0.03 µg/mm 2 of the coating after 168 h, compared with 0.01 ± 0.01 µg/mm 2 for LMWF alone. Although wettability remained similar to that of uncoated stents, the combined coating markedly enhanced endothelial cell adhesion, spreading, lamellipodia formation, proliferation, and MMP-2 secretion. These effects were accompanied by enhanced F-actin organization and redistribution of membrane-associated VE-cadherin, integrins β1 and α6, and syndecans-1 and-4, without major changes in their total expression. Importantly, the coating induced these responses without detectable cytotoxicity or significant inflammatory activation. Overall, the fibronectin-LMWF-based coating provides a stable biomimetic interface that enhances endothelialization through coordinated remodeling of adhesion, cytoskeletal, and glycocalyx-associated structures, while maintaining endothelial homeostasis on Co-Cr stent. This strategy offers a promising platform for next-generation glycocalyx-like stent coatings designed to improve vascular healing and limit restenosis. Graphical Fibronectin-assisted immobilization of low-molecular-weight fucoidan enhances endothelialization of Cobalt-Chromium stents. Schematic illustration of the sequential dip-coating modification of Cobalt-Chromium (Co-Cr) stents with fibronectin and low-molecular-weight fucoidan (LMWF), followed by HUVECs seeding and endothelial colonization. Fibronectin-assisted LMWF immobilization enhances coating retention and supports HUVECs adhesion, spreading, and proliferation. Representative microscopy images illustrate coating retention, endothelial morphology, surface colonization, and VE-cadherin distribution. The proposed coating architecture involves fibronectin adsorption onto the Co-Cr surface, followed by the formation of electrostatic interactions between fibronectin and LMWF as well as between LMWF and endothelial cell-surface components (selectins). Overall, these findings highlight the potential of fibronectin-LMWF coatings as a biomimetic strategy to promote Co-Cr stent endothelialization. Created in BioRender. Saadi, M. (2027) https://BioRender.com/6xb50t5 .

  • Design and Scalable Fabrication of Bioactive Ti/Polymer/Ti Sandwich Composites with Controlled Mechanics for Cranioplasty

    by Gargi Shankar Nayak, Pierre Mattei, Flavien Mouillard, Caroline Pereira, Heinz Palkowski, Celine Falentin-Daudre, Agnès Dupret-Bories, Patrick Masson, Adele Carrado

    The study presents the design and development of bioactive hybrid sandwich materials (SMs) for cranioplasty based on a Ti/polymer/Ti architecture engineered to optimize mechanical compatibility, formability, and biointegration. In this second-generation design, we replace the previously used PMMA core with a tunable P(MMA-ran-BMA) copolymer, enabling improved formability at near-room temperature and better matching of cranial bone mechanics. The polymer exhibits a tunable glass transition temperature, allowing for shaping at near-room temperature and enhancing delamination resistance. The Ti-polymer interfaces show strong adhesion (>10 MPa), achieved through surface-initiated polymerization. The sandwich structure provides lower thermal diffusivity and enhanced damping properties compared to monolithic Ti. Furthermore, the external Ti skins were postfunctionalized with poly sodium 4-styrenesulfonate (PNaSS) to introduce bioactivity, addressing the biological inertness of both Ti and methacrylate polymers. This functionalization improves cytocompatibility and promotes biomineralization. In a rat cranioplasty model, follow-up showed less early weight loss and a greater peak weight increase (35% compared to 24% for Ti), supporting improved early postoperative tolerance, although additional in vivo validation remains necessary.

  • Open Access

    Orthopedic implant surface modification with nanoengineered [YSZ/HAp-Ag]n multilayer coatings to promote osteoblast adhesion and early differentiation

    by E Lorena Medina, J.J. Vaca-González, Diego Quexada-Rodríguez, Salah Ramtani, Celine Falentin- Daudre, Diego Garzón-Alvarado

  • Antibacterial and antifungal effects of silver-doped multilayered yttria-stabilized zirconia and hydroxyapatite Coatings: Potential application in biomedical implants and orthopaedics

    by E Lorena Medina, J.J. Vaca-González, L.E. Sánchez-Rey, Nubia Moreno-Sarmiento, Salah Ramtani, Celine Falentin- Daudre, Diego Garzón-Alvarado


  • Retraction

    Retraction of “Thiol-Poly(Sodium Styrene Sulfonate) (PolyNaSS-SH) Gold Complexes: From a Chemical Design to a One-Step Synthesis of Hybrid Gold Nanoparticles and Their Interaction with Human Proteins”

    by Céline Falentin-Daudré, Mounia Aitouakli, Jean Sébastien Baumann, Nadia Bouchemal, Vincent Humblot, Véronique Migonney, Jolanda Spadavecchia

    [This retracts the article DOI: 10.1021/acsomega.0c00376.].

  • Open Access

    Enhancing Osseointegration Properties Through Bioactivation of a PCL Porous Scaffold Fabricated via Fused Deposition Modeling Process

    by Gabriel Roulhac De Rochebrune, Jean-Sébastien Baumann, Marc Lecouvey, Thibaut Legigan, Julia Deschamp, Céline Falentin-Daudré


  • Biodegradation study in FBS media of polycaprolactone patch as a potential prenatal treatment for myelomeningocele

    by K Benabdderrahmane, J Stirnemann, S Ramtani, C Falentin-Daudré

    Myelomeningocele (MMC) is a congenital defect of the spine characterized by meningeal and spinal cord protrusion through open vertebral archs, and its exposure to the amniotic fluid. Given that the progression of neuronal loss begins early in fetal life, an early coverage of the defect is required to improve the neurological outcomes. Several studies have proposed patches as an alternative to full surgical repair, to achieve an early protection of the spine and possibly reduce the rate of complications of current prenatal surgical procedures. In our previous work, we developed a biocompatible, watertight and biodegradable patch to improve in utero MMC repair. This patch offers an anti-adhesive internal surface to prevent adhesion to spinal cord tissue, and a bioactive external surface to promote tissue coverage. The aim of this study is to assess the patch’s in vitro degradation in an amniotic-fluid-like medium and investigate the surface functionalization effect, to understand its mechanism and predict the patch’s behavior over time. The study was carried out for 24 weeks in FBS medium and after each period the samples were characterized by differential scanning calorimetry, scanning electron microscopy, steric exclusion chromatography, toluidine blue assay and contact angle measurement. The results revealed a progression of PCL hydrolysis over time, characterized by a decrease in molar mass and evidence of erosion as observed by SEM. Furthermore, this process appears to be accelerated by ozonation, compared to surface functionalization without ozonation. The latter can be considered as the most suitable technique to preserve the patch structure over time, while benefiting from the grafting polymers properties during the first weeks of implantation.


  • Open Access

    Simple UV-Grafting of PolyAcrylic and PolyMethacrylic Acid on Silicone Breast Implant Surfaces: Chemical and Mechanical Characterizations

    by Anna Wozniak, Vincent Humblot, Romain Vayron, Rémi Delille, Céline Falentin-Daudré

    Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.


  • Open Access

    Influence of Surface Roughness on Nanocrystalline Diamond Films Deposited by Distributed Antenna Array Microwave System on TA6V Substrates

    by Azadeh Valinattaj Omran, Chaimaa Mahi, Romain Vayron, Céline Falentin-Daudré, Fabien Bénédic

    In this study, the characteristics of nanocrystalline diamond films synthesized at low surface temperature on Ti-6Al-4V (TA6V) substrates using a distributed antenna array microwave reactor aiming at biomedical applications were investigated. The surface roughness of the TA6V substrates is varied by scratching with emery paper of 1200, 2400, 4000 polishing grit. Nanocrystalline diamond (NCD) coatings with morphology, purity, and microstructure comparable to those obtained on silicon substrates usually employed in the same reactor and growth conditions are successfully achieved whatever the polishing protocol. However, the latter has a significant effect on the roughness parameters and hardness of the NCD films. The use of the finest polishing grit thus permits us to enhance the hardness value, which can be related to the work-hardening phenomenon arising from the polishing process.