Omar Nassar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Omar Nassar has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Jan Gerrit Korvink
Institute of Microstructure Technology Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany
10 shared publications - Dario Mager
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
8 shared publications - Sagar Wadhwa
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
5 shared publications - Mazin Jouda
Institute of Microstructure Technology, Karlsruhe Institute of Technology
4 shared publications - Neil MacKinnon
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
3 shared publications Yongbo Deng
State Key Laboratory of Applied Optics (SKLAO), Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Dongnanhu Road 3888, Changchun 130033, China
3 shared publications
Latest Publications
- Open Access
- 16 March 2023
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 14
Dynamic dielectrophoretic cell manipulation is enabled by an innovative electronics platform
- 16 March 2023
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 14
Open AccessDynamic dielectrophoretic cell manipulation is enabled by an innovative electronics platform
- Open Access
Highly Fluorinated Peptide Probes with Enhanced In Vivo Stability for 19F‐MRI
A labeling strategy for in vivo 19F‐MRI (magnetic resonance imaging) based on highly fluorinated, short hydrophilic peptide probes, is developed. As dual‐purpose probes, they are functionalized further by a fluorophore and an alkyne moiety for bioconjugation. High fluorination is achieved by three perfluoro‐tert‐butyl groups, introduced into asparagine analogues by chemically stable amide bond linkages. d‐amino acids and β‐alanine in the sequences endow the peptide probes with low cytotoxicity and high serum stability. This design also yielded unstructured peptides, rendering all 27 19F substitutions chemically equivalent, giving rise to a single 19F‐NMR resonance with 19F‐MRI is demonstrated for six different peptide probes. Using fluorescence microscopy, these probes are found to exhibit high stability and long circulation times in living zebrafish embryos. Furthermore, the probes can be conjugated to bovine serum albumin with only amoderate increase in 19F‐NMR linewidth to ≈30 Hz. Overall, these peptide probes are hence suitable for in vivo 19F‐MRI applications.
Open AccessHighly Fluorinated Peptide Probes with Enhanced In Vivo Stability for 19F‐MRI
A labeling strategy for in vivo 19F‐MRI (magnetic resonance imaging) based on highly fluorinated, short hydrophilic peptide probes, is developed. As dual‐purpose probes, they are functionalized further by a fluorophore and an alkyne moiety for bioconjugation. High fluorination is achieved by three perfluoro‐tert‐butyl groups, introduced into asparagine analogues by chemically stable amide bond linkages. d‐amino acids and β‐alanine in the sequences endow the peptide probes with low cytotoxicity and high serum stability. This design also yielded unstructured peptides, rendering all 27 19F substitutions chemically equivalent, giving rise to a single 19F‐NMR resonance with 19F‐MRI is demonstrated for six different peptide probes. Using fluorescence microscopy, these probes are found to exhibit high stability and long circulation times in living zebrafish embryos. Furthermore, the probes can be conjugated to bovine serum albumin with only amoderate increase in 19F‐NMR linewidth to ≈30 Hz. Overall, these peptide probes are hence suitable for in vivo 19F‐MRI applications.
- Open Access
- 14 April 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-17
Integrated impedance sensing of liquid sample plug flow enables automated high throughput NMR spectroscopy
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: (i) a micro saddle coil for NMR spectroscopy and (ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 nmol s1/2 with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 μL samples could be done within 3.6 min or effectively 15.3 s per sample.
- 14 April 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-17
Open AccessIntegrated impedance sensing of liquid sample plug flow enables automated high throughput NMR spectroscopy
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: (i) a micro saddle coil for NMR spectroscopy and (ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 nmol s1/2 with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 μL samples could be done within 3.6 min or effectively 15.3 s per sample.
- Open Access
Integrated impedance sensing of liquid sample plug flow enables automated high throughput NMR spectroscopy
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: i) a micro saddle coil for NMR spectroscopy and ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 $nmol \ s^{1/2}$ with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 $\mu$L samples could be done within 3.6 min or effectively 15.3 s per sample.Open AccessIntegrated impedance sensing of liquid sample plug flow enables automated high throughput NMR spectroscopy
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: i) a micro saddle coil for NMR spectroscopy and ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 $nmol \ s^{1/2}$ with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 $\mu$L samples could be done within 3.6 min or effectively 15.3 s per sample. - Open Access
- 13 November 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (47) , 53193-53205
Polyaramid-Based Flexible Antibacterial Coatings Fabricated Using Laser-Induced Carbonization and Copper Electroplating
A method for the fabrication of flexible electrical circuits on polyaramid substrates is presented based on laser-induced carbonization followed by copper electroplating. Locally carbonized flexible sheets of polyaramid (Nomex), by laser radiation, create rough and highly porous microstructures that show a higher degree of graphitization than thermally carbonized Nomex sheets. The found recipe for laser-induced carbonization creates conductivities of up to ∼45 S cm–1, thereby exceeding that observed for thermally pyrolyzed materials (∼38 S cm–1) and laser carbon derived from Kapton using the same laser wavelength (∼35 S cm–1). The electrical conductivity of the carbonized tracks was further improved by electroplating with copper. To demonstrate the electrical performance, fabricated circuits were tested and improvement of the sheet resistance was determined. Copper films exhibit antimicrobial activity and were used to fabricate customized flexible antibacterial coatings. The integration of laser carbonization and electroplating technologies in a polyaramid substrate points to the development of customized circuit designs for smart textiles operating in high-temperature environments.
- 13 November 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (47) , 53193-53205
Open AccessPolyaramid-Based Flexible Antibacterial Coatings Fabricated Using Laser-Induced Carbonization and Copper Electroplating
A method for the fabrication of flexible electrical circuits on polyaramid substrates is presented based on laser-induced carbonization followed by copper electroplating. Locally carbonized flexible sheets of polyaramid (Nomex), by laser radiation, create rough and highly porous microstructures that show a higher degree of graphitization than thermally carbonized Nomex sheets. The found recipe for laser-induced carbonization creates conductivities of up to ∼45 S cm–1, thereby exceeding that observed for thermally pyrolyzed materials (∼38 S cm–1) and laser carbon derived from Kapton using the same laser wavelength (∼35 S cm–1). The electrical conductivity of the carbonized tracks was further improved by electroplating with copper. To demonstrate the electrical performance, fabricated circuits were tested and improvement of the sheet resistance was determined. Copper films exhibit antimicrobial activity and were used to fabricate customized flexible antibacterial coatings. The integration of laser carbonization and electroplating technologies in a polyaramid substrate points to the development of customized circuit designs for smart textiles operating in high-temperature environments.
- Open Access
- 12 October 2020
- Published by Copernicus GmbH in Magnetic Resonance
- Vol. 1 (2) , 225-236
Topologically optimized magnetic lens for magnetic resonance applications
Improvements to the signal-to-noise ratio of magnetic resonance detection lead to a strong reduction in measurement time, yet as a sole optimization goal for resonator design, it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity and sample shape, suggest the use of numerical optimization to obtain resonator designs that deliver the intended improvement. Here we consider the 2D Lenz lens to be a sufficiently broadband flux transforming interposer between the sample and a radiofrequency (RF) circuit and to be a flexible and easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens and demonstrate realizations for both low- (45 MHz) and high-frequency (500 MHz) nuclear magnetic resonance.
- 12 October 2020
- Published by Copernicus GmbH in Magnetic Resonance
- Vol. 1 (2) , 225-236
Open AccessTopologically optimized magnetic lens for magnetic resonance applications
Improvements to the signal-to-noise ratio of magnetic resonance detection lead to a strong reduction in measurement time, yet as a sole optimization goal for resonator design, it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity and sample shape, suggest the use of numerical optimization to obtain resonator designs that deliver the intended improvement. Here we consider the 2D Lenz lens to be a sufficiently broadband flux transforming interposer between the sample and a radiofrequency (RF) circuit and to be a flexible and easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens and demonstrate realizations for both low- (45 MHz) and high-frequency (500 MHz) nuclear magnetic resonance.
- Open Access
- 22 July 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-19
Topologically Optimized Magnetic Lens for MR Applications
Improvements to the signal-to-noise ratio of magnetic resonance detection leads to a strong reduction in measurement time, yet as a sole optimization goal for resonator design it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity, and sample shape, suggests the use of numerical optimization to obtain resonator designs that delivers the intended improvement. Here we consider the 2D Lenz lens as a sufficiently broad-band flux transforming interposer between the sample and an RF circuit, as a flexible and an easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens, and demonstrate realisations for both low (45 MHz), and high frequency (500 MHz) NMR.
- 22 July 2020
- Published by Copernicus GmbH in EGUsphere
- Vol. 2020, 1-19
Open AccessTopologically Optimized Magnetic Lens for MR Applications
Improvements to the signal-to-noise ratio of magnetic resonance detection leads to a strong reduction in measurement time, yet as a sole optimization goal for resonator design it would be an oversimplification of the problem at hand. Multiple constraints, for example for field homogeneity, and sample shape, suggests the use of numerical optimization to obtain resonator designs that delivers the intended improvement. Here we consider the 2D Lenz lens as a sufficiently broad-band flux transforming interposer between the sample and an RF circuit, as a flexible and an easily manufacturable device family with which to mediate different design requirements. We report on a method to apply topology optimization to determine the optimal layout of a Lenz lens, and demonstrate realisations for both low (45 MHz), and high frequency (500 MHz) NMR.
- Open Access
- 22 July 2020
- Published by Copernicus GmbH
Supplementary material to "Topologically Optimized Magnetic Lens for MR Applications"
- 22 July 2020
- Published by Copernicus GmbH
Open AccessSupplementary material to "Topologically Optimized Magnetic Lens for MR Applications"
- Open Access
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (1) , 78-83
Wireless Double Micro-Resonator for Orientation Free Tracking of MR-Catheter During Interventional MRI
Interventional magnetic resonance imaging (iMRI) using MR-catheters has been explored during the past decade because of its potential impact on the field of minimally invasive medical procedures, especially applied to vascular diseases. Tracking the catheter's tip during an iMRI procedure using active electronic components has mayor benefits but still faces challenges regarding safety and the quality of visualization, which has prevented its clinical use up to now. Here we propose a novel micro detector with a total length of 8 mm built upon a flexible substrate with a total thickness of less than 60 um. The design of the detector is based on two perpendicularly oriented saddle coils that together create a homogeneous magnetic field when wrapped onto the catheter tube, thus maintaining constant visibility of the catheter under rotation, with practically no dead angle. Being self-resonant, the proposed detector allows wireless tracking of the catheter position, whilst preventing any heating hazard due to the absence of radiofrequency cables. The micro-resonator was fabricated using a multilayer flexible electronics fabrication process.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (1) , 78-83
Open AccessWireless Double Micro-Resonator for Orientation Free Tracking of MR-Catheter During Interventional MRI
Interventional magnetic resonance imaging (iMRI) using MR-catheters has been explored during the past decade because of its potential impact on the field of minimally invasive medical procedures, especially applied to vascular diseases. Tracking the catheter's tip during an iMRI procedure using active electronic components has mayor benefits but still faces challenges regarding safety and the quality of visualization, which has prevented its clinical use up to now. Here we propose a novel micro detector with a total length of 8 mm built upon a flexible substrate with a total thickness of less than 60 um. The design of the detector is based on two perpendicularly oriented saddle coils that together create a homogeneous magnetic field when wrapped onto the catheter tube, thus maintaining constant visibility of the catheter under rotation, with practically no dead angle. Being self-resonant, the proposed detector allows wireless tracking of the catheter position, whilst preventing any heating hazard due to the absence of radiofrequency cables. The micro-resonator was fabricated using a multilayer flexible electronics fabrication process.
- 1 February 2020
- Published by Elsevier in Biophysical Journal
- Vol. 118 (3) , 613a
Correlative in vivo Fluorescence Imaging and 19F-MRI of Zebrafish Embryos
- 1 February 2020
- Published by Elsevier in Biophysical Journal
- Vol. 118 (3) , 613a
Correlative in vivo Fluorescence Imaging and 19F-MRI of Zebrafish Embryos