Jun-Hee Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun-Hee Park has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Chul Pyun
Department of Materials Science and Engineering, Yonsei University, Seoul, South Korea
12 shared publications Min-Jung Kang
Korea Institute of Science and Technology (KIST), Seoul 02792, South Korea
10 shared publicationsZhiquan Song
Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, 03722, Seoul, South Korea
8 shared publicationsMoon-Ju Kim
Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, 03722, Seoul, South Korea
4 shared publicationsHong-Rae Kim
Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
3 shared publicationsHye Soo Kim
Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Yonsei University College of Medicine, Seoul 03722, South Korea
3 shared publications
Latest Publications
- Open Access
- 1 April 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (15) , 6176-6183
Polarized Superradiance from CsPbBr3 Quantum Dot Superlattice with Controlled Interdot Electronic Coupling
Cooperative emission of photons from an ensemble of quantum dots (QDs) as superradiance can arise from the electronically coupled QDs with a coherent emitting excited state. This contrasts with superfluorescence (Dicke superradiance), where the cooperative photon emission requires a buildup of coherence in an ensemble of incoherently excited QDs via their coupling to a common radiation mode. In perovskite QDs, superradiance has been rarely observed, unlike superfluorescence, due to the challenge in QD electronic coupling. Here, we report superradiance with a very narrow linewidth (3 QD superlattice achieved through the combination of quantum confinement and ligand engineering. The superradiance is polarized in contrast to the uncoupled exciton emission from the same superlattice, indicating anisotropic electronic coupling in superlattices. This finding suggests the potential of a perovskite QD superlattice with structurally controllable interdot coupling as the polarized cooperative photon emitters.
- 1 April 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (15) , 6176-6183
Open AccessPolarized Superradiance from CsPbBr3 Quantum Dot Superlattice with Controlled Interdot Electronic Coupling
Cooperative emission of photons from an ensemble of quantum dots (QDs) as superradiance can arise from the electronically coupled QDs with a coherent emitting excited state. This contrasts with superfluorescence (Dicke superradiance), where the cooperative photon emission requires a buildup of coherence in an ensemble of incoherently excited QDs via their coupling to a common radiation mode. In perovskite QDs, superradiance has been rarely observed, unlike superfluorescence, due to the challenge in QD electronic coupling. Here, we report superradiance with a very narrow linewidth (3 QD superlattice achieved through the combination of quantum confinement and ligand engineering. The superradiance is polarized in contrast to the uncoupled exciton emission from the same superlattice, indicating anisotropic electronic coupling in superlattices. This finding suggests the potential of a perovskite QD superlattice with structurally controllable interdot coupling as the polarized cooperative photon emitters.
- 20 February 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 277, 117274
Dual-mode capacitive and localized surface plasmon resonance biosensor based on high-density Au nanoislands
- 20 February 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 277, 117274
Dual-mode capacitive and localized surface plasmon resonance biosensor based on high-density Au nanoislands
- 2 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 609-616
Sepsis Diagnosis Based on a Parylene Matrix Chip Using LPC16:0 as a Biomarker in Comparison with Colorimetry of Total Phospholipid
For the medical diagnosis of sepsis, it is crucial to differentiate infectious inflammation from noninfectious symptoms to prevent acute aggravation. Herein, a diagnosis for early stage sepsis was performed using LPC 16:0 and total phospholipids as small molecular biomarkers. The measurement of LPC 16:0 was conducted using a parylene matrix chip, which was developed to effectively detect small molecules in laser desorption/ionization mass spectrometry (LDI-MS). Meanwhile, the total phospholipid level was measured using colorimetry, following an enzymatic assay. Next, the two biomarkers were analyzed in serum samples from healthy volunteers, systemic inflammatory response syndrome (SIRS) patients, and sepsis patients. Diagnostic criteria were established based on the biomarker intensities observed in each patient group. After the measurements were conducted, the interference in phospholipid analysis due to hemoglobin contamination was considered. Additionally, the analytical parameters from biomarker detection were statistically interpreted and compared with those of conventional diagnostic standards. Finally, the diagnostic performance of each biomarker was evaluated by analyzing the biomarker levels between patient groups and examining their overlapping extents in box plots to distinguish sepsis from noninfectious inflammatory symptoms.
- 2 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 609-616
Sepsis Diagnosis Based on a Parylene Matrix Chip Using LPC16:0 as a Biomarker in Comparison with Colorimetry of Total Phospholipid
For the medical diagnosis of sepsis, it is crucial to differentiate infectious inflammation from noninfectious symptoms to prevent acute aggravation. Herein, a diagnosis for early stage sepsis was performed using LPC 16:0 and total phospholipids as small molecular biomarkers. The measurement of LPC 16:0 was conducted using a parylene matrix chip, which was developed to effectively detect small molecules in laser desorption/ionization mass spectrometry (LDI-MS). Meanwhile, the total phospholipid level was measured using colorimetry, following an enzymatic assay. Next, the two biomarkers were analyzed in serum samples from healthy volunteers, systemic inflammatory response syndrome (SIRS) patients, and sepsis patients. Diagnostic criteria were established based on the biomarker intensities observed in each patient group. After the measurements were conducted, the interference in phospholipid analysis due to hemoglobin contamination was considered. Additionally, the analytical parameters from biomarker detection were statistically interpreted and compared with those of conventional diagnostic standards. Finally, the diagnostic performance of each biomarker was evaluated by analyzing the biomarker levels between patient groups and examining their overlapping extents in box plots to distinguish sepsis from noninfectious inflammatory symptoms.
- 6 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (46) , 63255-63267
Plasma Deposition of Parylene-like Films with Chemical Functional Groups for Immunoassays
Parylene-like films obtained via the plasma decomposition of parylene precursors with functional groups (amino and formyl) are proposed as an alternative to those obtained via the thermal method. To analyze the chemical functional groups after plasma deposition, a surface analysis of the parylene films using the two different deposition methods was performed via Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopy (XPS). The FT-IR analysis revealed that the featured peaks of the chemical functional groups were maintained in the parylene-like films obtained via the plasma deposition method. The XPS analysis revealed that the featured chemical functional groups of parylene-AM and parylene-H were maintained after plasma deposition. The surface energy of the parylene films was estimated by using contact angle measurements. The plasma-deposited parylene films were then employed for protein immobilization via the functional groups using horseradish peroxidase (44 kDa) and green fluorescent protein (25 kDa) as model proteins. The parylene-AM and parylene-H films obtained via plasma deposition exhibited higher immobilization efficiencies than did the same parylene films obtained via thermal deposition. Finally, a competitive immunoassay was obtained by immobilizing the Fv-antibodies on plasma-deposited parylene-AM and parylene-H films via covalent bonding. Using heat-deactivated SARS-CoV-2 as a real sample, the limit of detection at the feasible level for the medical diagnosis of COVID-19 was achieved using a competitive immunoassay based on immobilized Fv-antibodies on plasma-deposited parylene films.
- 6 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (46) , 63255-63267
Plasma Deposition of Parylene-like Films with Chemical Functional Groups for Immunoassays
Parylene-like films obtained via the plasma decomposition of parylene precursors with functional groups (amino and formyl) are proposed as an alternative to those obtained via the thermal method. To analyze the chemical functional groups after plasma deposition, a surface analysis of the parylene films using the two different deposition methods was performed via Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopy (XPS). The FT-IR analysis revealed that the featured peaks of the chemical functional groups were maintained in the parylene-like films obtained via the plasma deposition method. The XPS analysis revealed that the featured chemical functional groups of parylene-AM and parylene-H were maintained after plasma deposition. The surface energy of the parylene films was estimated by using contact angle measurements. The plasma-deposited parylene films were then employed for protein immobilization via the functional groups using horseradish peroxidase (44 kDa) and green fluorescent protein (25 kDa) as model proteins. The parylene-AM and parylene-H films obtained via plasma deposition exhibited higher immobilization efficiencies than did the same parylene films obtained via thermal deposition. Finally, a competitive immunoassay was obtained by immobilizing the Fv-antibodies on plasma-deposited parylene-AM and parylene-H films via covalent bonding. Using heat-deactivated SARS-CoV-2 as a real sample, the limit of detection at the feasible level for the medical diagnosis of COVID-19 was achieved using a competitive immunoassay based on immobilized Fv-antibodies on plasma-deposited parylene films.
- 5 June 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (11) , 13194-13205
Combi-Matrix Based on TiO2 Aerogel for Diagnosis of Sepsis Using Laser Desorption and Ionization Mass Spectrometry
- 5 June 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (11) , 13194-13205
Combi-Matrix Based on TiO2 Aerogel for Diagnosis of Sepsis Using Laser Desorption and Ionization Mass Spectrometry
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56702-56716
Defect-Passivated Photosensor Based on Cesium Lead Bromide (CsPbBr3) Perovskite Quantum Dots for Microbial Detection
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56702-56716
Defect-Passivated Photosensor Based on Cesium Lead Bromide (CsPbBr3) Perovskite Quantum Dots for Microbial Detection
- 18 July 2023
- Published by Elsevier in Materials Today Communications
- Vol. 36
Parylene-coated SiO2 aerogel with controlled thermal conductivity
- 18 July 2023
- Published by Elsevier in Materials Today Communications
- Vol. 36
Parylene-coated SiO2 aerogel with controlled thermal conductivity
- 5 January 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (1) , 215-224
Electrochemical One-Step Immunoassay Based on Switching Peptides and Pyrolyzed Carbon Electrodes
Switching peptides were designed to bind reversibly to the binding pocket of antibodies (IgG) by interacting with frame regions (FRs). These peptides can be quantitatively released when antigens bind to IgG. As FRs have conserved amino acid sequences, switching peptides can be used as antibodies for different antigens and different source animals. In this study, an electrochemical one-step immunoassay was conducted using switching peptides labeled with ferrocene for the quantitative measurement of analytes. For the effective amperometry of the switching peptides labeled with ferrocene, a pyrolyzed carbon electrode was prepared by pyrolysis of the parylene-C film. The feasibility of the pyrolyzed carbon electrode for the electrochemical one-step immunoassay was determined by analyzing its electrochemical properties, such as its low double-layer capacitance (Cdl), high electron transfer rate (kapp), and wide electrochemical window. In addition, the factors influencing the amperometry of switching peptides labeled with ferrocene were analyzed according to the hydrodynamic radius, the number of intrahydrogen bonds, dipole moments, and diffusion coefficients. Finally, the applicability of the electrochemical one-step immunoassay for the medical diagnosis of the human hepatitis B surface antigen (hHBsAg) was assessed.
- 5 January 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (1) , 215-224
Electrochemical One-Step Immunoassay Based on Switching Peptides and Pyrolyzed Carbon Electrodes
Switching peptides were designed to bind reversibly to the binding pocket of antibodies (IgG) by interacting with frame regions (FRs). These peptides can be quantitatively released when antigens bind to IgG. As FRs have conserved amino acid sequences, switching peptides can be used as antibodies for different antigens and different source animals. In this study, an electrochemical one-step immunoassay was conducted using switching peptides labeled with ferrocene for the quantitative measurement of analytes. For the effective amperometry of the switching peptides labeled with ferrocene, a pyrolyzed carbon electrode was prepared by pyrolysis of the parylene-C film. The feasibility of the pyrolyzed carbon electrode for the electrochemical one-step immunoassay was determined by analyzing its electrochemical properties, such as its low double-layer capacitance (Cdl), high electron transfer rate (kapp), and wide electrochemical window. In addition, the factors influencing the amperometry of switching peptides labeled with ferrocene were analyzed according to the hydrodynamic radius, the number of intrahydrogen bonds, dipole moments, and diffusion coefficients. Finally, the applicability of the electrochemical one-step immunoassay for the medical diagnosis of the human hepatitis B surface antigen (hHBsAg) was assessed.
- 26 October 2021
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 4 (11) , 7779-7789
Rapid Analysis of Bacterial Contamination in Platelets without Pre-Enrichment Using Pig Serum-Derived Antibodies
As the shelf life of platelets collected from donated blood is very short, approximately 5 days, the determination of bacterial contamination in platelets has become necessary. In this study, rapid analysis of Gram-positive and Gram-negative bacterial contamination in platelet samples was presented without pre-enrichment using pig serum-derived antibodies against the outer membrane proteins (OMP) of Gram-negative bacteria and antibodies against lipoteichoic acid (LTA) on the surface of Gram-positive bacteria. The anti-OMP antibodies against Gram-negative bacteria were isolated using sequential incubation with (1) the modified Gram-negative bacteria ClearColi, which lacks lipopolysaccharide (LPS) on the outer membrane, and (2) the Gram-positive bacteriaBacillus subtilis to filter away nonspecifically bound proteins from ClearColi. The anti-lipoteichoic acid (LTA) antibodies against Gram-positive bacteria were isolated using sequential incubation with (1) the Gram-positive bacteriaB. subtilis and (2) the Gram-negative bacteria Escherichia coli BL21 to filter away nonspecifically bound proteins fromB. subtilis. The feasibility of using the antibodies isolated from pig serum against Gram-negative and Gram-positive bacteria was demonstrated using flow cytometry. Finally, detection of the contamination of platelets with Gram-negative and Gram-positive bacteria using the impedance immunosensor based on these isolated antibodies was successfully demonstrated.
- 26 October 2021
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 4 (11) , 7779-7789
Rapid Analysis of Bacterial Contamination in Platelets without Pre-Enrichment Using Pig Serum-Derived Antibodies
As the shelf life of platelets collected from donated blood is very short, approximately 5 days, the determination of bacterial contamination in platelets has become necessary. In this study, rapid analysis of Gram-positive and Gram-negative bacterial contamination in platelet samples was presented without pre-enrichment using pig serum-derived antibodies against the outer membrane proteins (OMP) of Gram-negative bacteria and antibodies against lipoteichoic acid (LTA) on the surface of Gram-positive bacteria. The anti-OMP antibodies against Gram-negative bacteria were isolated using sequential incubation with (1) the modified Gram-negative bacteria ClearColi, which lacks lipopolysaccharide (LPS) on the outer membrane, and (2) the Gram-positive bacteriaBacillus subtilis to filter away nonspecifically bound proteins from ClearColi. The anti-lipoteichoic acid (LTA) antibodies against Gram-positive bacteria were isolated using sequential incubation with (1) the Gram-positive bacteriaB. subtilis and (2) the Gram-negative bacteria Escherichia coli BL21 to filter away nonspecifically bound proteins fromB. subtilis. The feasibility of using the antibodies isolated from pig serum against Gram-negative and Gram-positive bacteria was demonstrated using flow cytometry. Finally, detection of the contamination of platelets with Gram-negative and Gram-positive bacteria using the impedance immunosensor based on these isolated antibodies was successfully demonstrated.