Chengning Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chengning Zhang has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Shuo Zhang
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
26 shared publications - Xueping Li
Beijing Institute of Technology
9 shared publications - Xin Yuan
Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, U.K.
8 shared publications - Yuelin Dong
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
7 shared publications - Shulin Wang
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
6 shared publications - Ying Zhou
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
4 shared publications
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP, 1
Current Predictive Control-Based Open-Phase Fault-Tolerant Operation Scheme for Open-Winding SPMSMs
Open-winding permanent magnet synchronous mo-tors (OW-PMSMs) have attracted increasing attention in trans-portation applications due to their inherent fault-tolerant (FT) ca-pability. However, existing FT control strategies typically face a trade-off between control performance and implementation effi-ciency. This paper proposes a predictive-control-based post-fault management scheme in the stator phase domain for surface-mounted OW-PMSMs under single-phase open-circuit faults. A normalized phase-current-residual-based diagnostic method is first developed to enable reliable fault localization and fast transi-tion to FT operation, with a detection time of approximately 10% of an electrical cycle. A mutual-inductance-aware FT predictive control (MIFTPC) strategy is then established to improve post-fault current and voltage prediction accuracy, thereby enhancing torque control quality under FT operation. In addition, a unified phase-domain framework directly maps predicted phase voltages to sector selection and dual-inverter switching states, avoiding co-ordinate transformations and complex coordinated modulation while simplifying implementation. Experimental results on a 0.4-kW OW-PMSM drive (rated speed 1000 r/min, rated torque 4 N·m) demonstrate the effectiveness of the proposed method under vari-ous conditions. Relative to a mutual-inductance-neglecting method, the proposed approach reduces current deviation and torque rip-ple RMS by approximately 21.8% and 34.6%, respectively.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP, 1
Current Predictive Control-Based Open-Phase Fault-Tolerant Operation Scheme for Open-Winding SPMSMs
Open-winding permanent magnet synchronous mo-tors (OW-PMSMs) have attracted increasing attention in trans-portation applications due to their inherent fault-tolerant (FT) ca-pability. However, existing FT control strategies typically face a trade-off between control performance and implementation effi-ciency. This paper proposes a predictive-control-based post-fault management scheme in the stator phase domain for surface-mounted OW-PMSMs under single-phase open-circuit faults. A normalized phase-current-residual-based diagnostic method is first developed to enable reliable fault localization and fast transi-tion to FT operation, with a detection time of approximately 10% of an electrical cycle. A mutual-inductance-aware FT predictive control (MIFTPC) strategy is then established to improve post-fault current and voltage prediction accuracy, thereby enhancing torque control quality under FT operation. In addition, a unified phase-domain framework directly maps predicted phase voltages to sector selection and dual-inverter switching states, avoiding co-ordinate transformations and complex coordinated modulation while simplifying implementation. Experimental results on a 0.4-kW OW-PMSM drive (rated speed 1000 r/min, rated torque 4 N·m) demonstrate the effectiveness of the proposed method under vari-ous conditions. Relative to a mutual-inductance-neglecting method, the proposed approach reduces current deviation and torque rip-ple RMS by approximately 21.8% and 34.6%, respectively.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61  (3) , 3821-3832
An Efficient Method to Evaluate the Effect of Additional Air Gaps on the Cogging Torque for the PM Machines With Modular Stator
Due to the uncertainties in the manufacturing process, the additional air gaps (AAG) between adjacent stator segments in the modular stator machines are inevitable, which might deteriorate the cogging torque performance. To evaluate the influences of the uncertainties, a large number of finite element analysis (FEA) calculations on designs featuring different uncertain combinations are always required. The correspondingly high computational cost is the biggest obstacle to uncertainties analysis and robust design. To solve this problem, an approach based on the worst–uncertain–combination–analysis (WUCA) method is proposed to theoretically find the possible worst-case under uncertainties. With the help of the WUCA approach, the influence of AAG uncertainties on the cogging torque could be estimated by calculating at most two specific combinations. The efficacy of the proposed method is verified by FEA results for different pole/slot configurations. Then, the influence of the connecting tongue shape on cogging torque robustness is comparatively analyzed based on WUCA. It is found that the relatively complex T-shape is preferable from the robustness point. Finally, four prototypes are developed and tested to prove the proposed conclusion, and the experimental results are presented.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61  (3) , 3821-3832
An Efficient Method to Evaluate the Effect of Additional Air Gaps on the Cogging Torque for the PM Machines With Modular Stator
Due to the uncertainties in the manufacturing process, the additional air gaps (AAG) between adjacent stator segments in the modular stator machines are inevitable, which might deteriorate the cogging torque performance. To evaluate the influences of the uncertainties, a large number of finite element analysis (FEA) calculations on designs featuring different uncertain combinations are always required. The correspondingly high computational cost is the biggest obstacle to uncertainties analysis and robust design. To solve this problem, an approach based on the worst–uncertain–combination–analysis (WUCA) method is proposed to theoretically find the possible worst-case under uncertainties. With the help of the WUCA approach, the influence of AAG uncertainties on the cogging torque could be estimated by calculating at most two specific combinations. The efficacy of the proposed method is verified by FEA results for different pole/slot configurations. Then, the influence of the connecting tongue shape on cogging torque robustness is comparatively analyzed based on WUCA. It is found that the relatively complex T-shape is preferable from the robustness point. Finally, four prototypes are developed and tested to prove the proposed conclusion, and the experimental results are presented.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (2) , 2285-2295
Improved DC-Link Voltage Sliding Mode Control for Permanent Magnet Synchronous Generator Systems With Three-Phase AC-DC Converters
Conventional proportional-integral (PI) controller is commonly utilized in the DC-link voltage control outer loop of permanent magnet synchronous generator (PMSG) systems. However, it cannot achieve consistent DC-link voltage control performance across the entire operating range, resulting in poor dynamic response. In contrast, DC-link voltage sliding mode control (SMC) offers faster dynamic performance compared to conventional PI control. Nevertheless, stability analysis indicates that SMC may result in voltage tracking errors when the disturbance power is significant. To address this issue, a disturbance power observer based on recursive least squares (RLS) with a forgetting factor is proposed. The RLS-based observer can achieve minimum variance estimation of the total disturbance power, and its convergence speed can be adjusted by tuning the forgetting factor. By feeding forward the RLS-observed power into the SMC (referred to as SMC+RLS method), the DC-link voltage control performance is significantly improved. Experimental results demonstrate that the proposed SMC+RLS method exhibits a faster dynamic response than both conventional PI control and state-of-the-art nonlinear controllers when the operating point changes. Moreover, the disturbance power can be quickly observed by the RLS-based observer, providing the SMC+RLS method with excellent anti-disturbance performance.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13  (2) , 2285-2295
Improved DC-Link Voltage Sliding Mode Control for Permanent Magnet Synchronous Generator Systems With Three-Phase AC-DC Converters
Conventional proportional-integral (PI) controller is commonly utilized in the DC-link voltage control outer loop of permanent magnet synchronous generator (PMSG) systems. However, it cannot achieve consistent DC-link voltage control performance across the entire operating range, resulting in poor dynamic response. In contrast, DC-link voltage sliding mode control (SMC) offers faster dynamic performance compared to conventional PI control. Nevertheless, stability analysis indicates that SMC may result in voltage tracking errors when the disturbance power is significant. To address this issue, a disturbance power observer based on recursive least squares (RLS) with a forgetting factor is proposed. The RLS-based observer can achieve minimum variance estimation of the total disturbance power, and its convergence speed can be adjusted by tuning the forgetting factor. By feeding forward the RLS-observed power into the SMC (referred to as SMC+RLS method), the DC-link voltage control performance is significantly improved. Experimental results demonstrate that the proposed SMC+RLS method exhibits a faster dynamic response than both conventional PI control and state-of-the-art nonlinear controllers when the operating point changes. Moreover, the disturbance power can be quickly observed by the RLS-based observer, providing the SMC+RLS method with excellent anti-disturbance performance.
- Open Access
Oil Cooling Method for Internal Heat Sources in the Outer Rotor Hub Motor of ElectricVehicle and Thermal Characteristics Research
The heat dissipation of wheel hub motors is difficult due to the limited installation space and harsh working environment, which will lead to an increase in the operating temperature of the motor. Excessive motor temperature will limit the further increase in the power density and torque density of the motor. Taking the outer rotor hub motor as the research object, a heat dissipation structure is designed by passing oil through the stator core, slot wedge, and the motor end, mainly the cooling stator core, slot winding, and the end winding from inside of the motor. The internal heat is mainly carried away through lubricating oil by convective heat transfer and heat conduction. The heat distribution model of the motor based on the new cooling structure is established using the centralized parameter heat network method. The Motor-CAD software is used to build the motor 3d model and simulate the motor temperature field, and the temperature distribution in the motor under the rated working condition is analyzed. The temperature rising test of the motor prototype are performed on a bench built in the laboratory. The experimental results are consistent with the simulation results of the temperature field, which verify the rationality of the model.
Open AccessOil Cooling Method for Internal Heat Sources in the Outer Rotor Hub Motor of ElectricVehicle and Thermal Characteristics Research
The heat dissipation of wheel hub motors is difficult due to the limited installation space and harsh working environment, which will lead to an increase in the operating temperature of the motor. Excessive motor temperature will limit the further increase in the power density and torque density of the motor. Taking the outer rotor hub motor as the research object, a heat dissipation structure is designed by passing oil through the stator core, slot wedge, and the motor end, mainly the cooling stator core, slot winding, and the end winding from inside of the motor. The internal heat is mainly carried away through lubricating oil by convective heat transfer and heat conduction. The heat distribution model of the motor based on the new cooling structure is established using the centralized parameter heat network method. The Motor-CAD software is used to build the motor 3d model and simulate the motor temperature field, and the temperature distribution in the motor under the rated working condition is analyzed. The temperature rising test of the motor prototype are performed on a bench built in the laboratory. The experimental results are consistent with the simulation results of the temperature field, which verify the rationality of the model.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6  (2) , 612-623
Robust Fault-Tolerant Control Scheme for Open-Winding Permanent Magnet Synchronous Motors Based on Improved Predictive Control
Fault-tolerant control is crucial for ensuring reliable operation in the field of motor drives. The common-bus open-winding permanent magnet synchronous motor (OW-PMSM) topology, by involving the important role of zero-sequence loop (ZSL), provides a new technical approach for fault-tolerant operation under single-phase open-circuit faults. In this paper, a robust fault-tolerant control strategy based on improved predictive control for the open-phase fault of OW-PMSM is proposed, enhancing post-fault torque control performance. Firstly, the new characteristics of the post-fault currents are derived, and the dq0 -axis reference currents are redesigned accordingly, retaining the fundamental frequency component of the zero-sequence current (ZSC) to maintain constant torque output capability. The q -axis reference current is modified to mitigate high-frequency torque ripples caused by the ZSC. Then, the parameter term deviations are calculated using the error between the predicted and measured currents, and the parameter terms in the predictive model are updated to improve the accuracy of the target voltages. Experimental results validate the comprehensive performance of the innovative method for fault-tolerant control and robust torque control, both in dynamic and steady states.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6  (2) , 612-623
Robust Fault-Tolerant Control Scheme for Open-Winding Permanent Magnet Synchronous Motors Based on Improved Predictive Control
Fault-tolerant control is crucial for ensuring reliable operation in the field of motor drives. The common-bus open-winding permanent magnet synchronous motor (OW-PMSM) topology, by involving the important role of zero-sequence loop (ZSL), provides a new technical approach for fault-tolerant operation under single-phase open-circuit faults. In this paper, a robust fault-tolerant control strategy based on improved predictive control for the open-phase fault of OW-PMSM is proposed, enhancing post-fault torque control performance. Firstly, the new characteristics of the post-fault currents are derived, and the dq0 -axis reference currents are redesigned accordingly, retaining the fundamental frequency component of the zero-sequence current (ZSC) to maintain constant torque output capability. The q -axis reference current is modified to mitigate high-frequency torque ripples caused by the ZSC. Then, the parameter term deviations are calculated using the error between the predicted and measured currents, and the parameter terms in the predictive model are updated to improve the accuracy of the target voltages. Experimental results validate the comprehensive performance of the innovative method for fault-tolerant control and robust torque control, both in dynamic and steady states.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72  (6) , 5591-5601
An Improved Model-Free Adaptive Current Control for PMSM Based on Prior-Optimization
Current predictive control methods are sensitive to motor parameters, while model-free control methods often require extensive offline data or involve complex parameter coupling, making tuning challenging. To address these limitations, this article proposes a prior-optimized model-free adaptive current control (POMFACC) method. By using current and voltage signals to create a multiple-input multiple-output system, this method eliminates the need for specific motor knowledge. It also constructs a multiobjective optimization function for current control and uses the nondominated sorting genetic algorithm II to automatically optimize interdependent parameters, addressing the challenges of repeated trial-and-error adjustments and inaccurate settings. Results demonstrate that the POMFACC method is widely applicable, does not depend on offline data, maintains a moderate computational burden, and effectively enhances motor control accuracy and robustness.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72  (6) , 5591-5601
An Improved Model-Free Adaptive Current Control for PMSM Based on Prior-Optimization
Current predictive control methods are sensitive to motor parameters, while model-free control methods often require extensive offline data or involve complex parameter coupling, making tuning challenging. To address these limitations, this article proposes a prior-optimized model-free adaptive current control (POMFACC) method. By using current and voltage signals to create a multiple-input multiple-output system, this method eliminates the need for specific motor knowledge. It also constructs a multiobjective optimization function for current control and uses the nondominated sorting genetic algorithm II to automatically optimize interdependent parameters, addressing the challenges of repeated trial-and-error adjustments and inaccurate settings. Results demonstrate that the POMFACC method is widely applicable, does not depend on offline data, maintains a moderate computational burden, and effectively enhances motor control accuracy and robustness.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 74  (3) , 4076-4086
Optimal Structure Selection and Integrated Optimization of Parameters of a Dual-Motor-Driven System in Battery Electric Bus
In this paper, in order to promote the efficiency and control the production cost of a dual-motor-driven system (DMDS), the topology is selected and the parameters of DMDS are optimized based on a bi-level integrated optimization method. In this method, five topologies are considered, including three kinds of speed coupling topologies, one kind of torque coupling topology, and one kind of topology with variable coupling. The dynamic model and efficiency model of each topology are established. The proposed integration optimization method includes a dynamic programming (DP) algorithm and a particle swarm optimization (PSO) algorithm. DP takes energy loss as the objective function to optimize the control strategy of the operation process. PSO takes the linear superposition value of energy loss and motor power level as the objective function to optimize design parameters. The optimization results of five topologies are compared to get the optimal topology. The results of integrated optimization experiments show that the speed coupling - double brake topology is the optimal topology. Compared with the prototype, the energy loss is reduced by 10.37% and the system production cost has been well controlled. The comparison experiments further validate the superiority of utilizing PSO as the upper layer algorithm compared to other comparative algorithms.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 74  (3) , 4076-4086
Optimal Structure Selection and Integrated Optimization of Parameters of a Dual-Motor-Driven System in Battery Electric Bus
In this paper, in order to promote the efficiency and control the production cost of a dual-motor-driven system (DMDS), the topology is selected and the parameters of DMDS are optimized based on a bi-level integrated optimization method. In this method, five topologies are considered, including three kinds of speed coupling topologies, one kind of torque coupling topology, and one kind of topology with variable coupling. The dynamic model and efficiency model of each topology are established. The proposed integration optimization method includes a dynamic programming (DP) algorithm and a particle swarm optimization (PSO) algorithm. DP takes energy loss as the objective function to optimize the control strategy of the operation process. PSO takes the linear superposition value of energy loss and motor power level as the objective function to optimize design parameters. The optimization results of five topologies are compared to get the optimal topology. The results of integrated optimization experiments show that the speed coupling - double brake topology is the optimal topology. Compared with the prototype, the energy loss is reduced by 10.37% and the system production cost has been well controlled. The comparison experiments further validate the superiority of utilizing PSO as the upper layer algorithm compared to other comparative algorithms.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34  (8) , 1-4
Enhanced Maximum Torque per Ampere Control With Predictable Core Loss for the Interior Permanent Magnet Synchronous Motor
Due to the availability of extended applications for the reluctance torque, increasing incorporation of interior permanent magnet synchronous motors (IPMSMs) has been observed in the electric drive system, and to save energy and improve operation efficiency, the maximum torque per ampere (MTPA) control has attracted a lot of academic attention. However, in the traditional MTPA, the optimization objective of tracking the minimum armature current only applies to the situation where the energy consumption in the winding resistance is imposed as the sole constraint. The energy consumption in the core material, i.e., core loss, will grow as motor load and frequency increase, and hence the efficiency optimization control of the IPMSM should also consider the core loss. Firstly, this article proposes a novel mathematical model of the IPMSM which enables the establishment of control algorithms with predictable core loss. Then, a novel MTPA is proposed which can simultaneously optimize the copper loss and core loss to maximize the utilization of phase currents and minimize the electromagnetic losses of the IPMSM. To verify the superiority of the proposed MTPA, the analytical results are compared with the conventional MTPA and Id = 0 control methods.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34  (8) , 1-4
Enhanced Maximum Torque per Ampere Control With Predictable Core Loss for the Interior Permanent Magnet Synchronous Motor
Due to the availability of extended applications for the reluctance torque, increasing incorporation of interior permanent magnet synchronous motors (IPMSMs) has been observed in the electric drive system, and to save energy and improve operation efficiency, the maximum torque per ampere (MTPA) control has attracted a lot of academic attention. However, in the traditional MTPA, the optimization objective of tracking the minimum armature current only applies to the situation where the energy consumption in the winding resistance is imposed as the sole constraint. The energy consumption in the core material, i.e., core loss, will grow as motor load and frequency increase, and hence the efficiency optimization control of the IPMSM should also consider the core loss. Firstly, this article proposes a novel mathematical model of the IPMSM which enables the establishment of control algorithms with predictable core loss. Then, a novel MTPA is proposed which can simultaneously optimize the copper loss and core loss to maximize the utilization of phase currents and minimize the electromagnetic losses of the IPMSM. To verify the superiority of the proposed MTPA, the analytical results are compared with the conventional MTPA and Id = 0 control methods.
- 15 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73  (12) , 18391-18401
A 3D Lidar Odometry and Mapping Method Based on Clustering-Directed Feature Point
Lidar odometry (LO) aims to provide robot attitude estimation, which is crucial for robot motion decision-making. In this paper, a new method of lidar odometry and mapping based on clustering-directed feature points (CDP-LOAM) is proposed. The proposed approach introduces a seven-dimensional clustering-directed point (CDP) that encompasses three-dimensional coordinate information, three-dimensional feature vector information, and one-dimensional point cloud category information of LiDAR points. Among them, the point cloud categories are obtained through ground point segmentation and point cloud clustering, and the feature vectors are obtained by processing the classified point clouds with principal component analysis (PCA). The paper proposes a two-step point cloud matching approach and establishes an adaptable weighted comprehensive residual that includes distance and direction residuals of the associated point cloud. The attitude estimation results are obtained by optimizing the residual error. The experimental results demonstrate that this method achieves more accurate positioning results than the traditional lidar method in a wider range of application scenarios.
- 15 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73  (12) , 18391-18401
A 3D Lidar Odometry and Mapping Method Based on Clustering-Directed Feature Point
Lidar odometry (LO) aims to provide robot attitude estimation, which is crucial for robot motion decision-making. In this paper, a new method of lidar odometry and mapping based on clustering-directed feature points (CDP-LOAM) is proposed. The proposed approach introduces a seven-dimensional clustering-directed point (CDP) that encompasses three-dimensional coordinate information, three-dimensional feature vector information, and one-dimensional point cloud category information of LiDAR points. Among them, the point cloud categories are obtained through ground point segmentation and point cloud clustering, and the feature vectors are obtained by processing the classified point clouds with principal component analysis (PCA). The paper proposes a two-step point cloud matching approach and establishes an adaptable weighted comprehensive residual that includes distance and direction residuals of the associated point cloud. The attitude estimation results are obtained by optimizing the residual error. The experimental results demonstrate that this method achieves more accurate positioning results than the traditional lidar method in a wider range of application scenarios.
- 2 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11  (1) , 3298-3310
Improved Parameter Robust Feedforward Formula-Based Flux-Weakening Method for Surface-Mounted Permanent Magnet Synchronous Motor
To improve the parameter robustness of the feedforward formula-based flux-weakening method (FBFW), a parameter robust formula-based flux-weakening method based on current prediction error (FBFW-CPE) is proposed in this paper. The current prediction error is employed to extract the accurate value of the intermediate variable required by the FBFW, and an improved flux-weakening formula which is not affected by the parameter mismatch is proposed, so as to enhance the parameter robustness and environmental adaptability. The proposed method can also solve the parameter mismatch problem of deadbeat predictive current control (DPCC) with the intermediate variables. The recursive least squares (RLS) method is introduced to the proposed method to improve the stability of the method and reduce harmonics. To demonstrate the effectiveness of the proposed method, sufficient simulations and experiments are carried out on the conventional FBFW method and the proposed FBFW-CPE method. According to the comparison of the results of simulations and experiments, it is learned that the proposed method has better performance under various parameter mismatch conditions and various working conditions.
- 2 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11  (1) , 3298-3310
Improved Parameter Robust Feedforward Formula-Based Flux-Weakening Method for Surface-Mounted Permanent Magnet Synchronous Motor
To improve the parameter robustness of the feedforward formula-based flux-weakening method (FBFW), a parameter robust formula-based flux-weakening method based on current prediction error (FBFW-CPE) is proposed in this paper. The current prediction error is employed to extract the accurate value of the intermediate variable required by the FBFW, and an improved flux-weakening formula which is not affected by the parameter mismatch is proposed, so as to enhance the parameter robustness and environmental adaptability. The proposed method can also solve the parameter mismatch problem of deadbeat predictive current control (DPCC) with the intermediate variables. The recursive least squares (RLS) method is introduced to the proposed method to improve the stability of the method and reduce harmonics. To demonstrate the effectiveness of the proposed method, sufficient simulations and experiments are carried out on the conventional FBFW method and the proposed FBFW-CPE method. According to the comparison of the results of simulations and experiments, it is learned that the proposed method has better performance under various parameter mismatch conditions and various working conditions.