Thuany Garcia Maraschin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thuany Garcia Maraschin has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Nara Regina de Souza Basso
Pontifícia Universidade Católica do Rio Grande do Sul, Brazil
7 shared publications - Griselda Barrera Galland
Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
6 shared publications Eduardo Cassel
3 shared publicationsGiovani Pavoski
3 shared publications- Cássio Stein Moura
Geofísica Stein, Porto Alegre, Brazil
2 shared publications Griselda B. Galland
2 shared publications
Latest Publications
- Open Access
Electrochemical Detection of SMN Protein by Immunosensors: The Role of Surface Modifications in Screen-Printed Carbon Electrodes
Point-of-care (POC) technologies are promising tools to decentralize and accelerate the diagnosis of rare diseases. Among them, electrochemical immunosensors offer advantages such as high sensitivity, low cost, portability, low sample consumption, and suitability for use in resource-limited settings. However, the performance of these devices is dependent on electrode surface properties, which influence electron transfer, biomolecule immobilization, and analytical sensitivity. In this work, screen-printed carbon electrodes (SPCEs) were modified through two strategies: (i) gold electrodeposition and (ii) cold plasma treatment. The modified electrodes were functionalized with EDC/NHS, followed by the immobilization of anti-SMN antibodies and electrochemical characterization using cyclic voltammetry and differential pulse voltammetry. The impact of each modification approach on the electrochemical response and reproducibility of the sensor was evaluated. Gold electrodeposition resulted in higher and more reproducible electrochemical responses, demonstrating improved electron transfer properties and surface homogeneity. The primary objective of this study was to investigate how different surface modification strategies affect the electrochemical performance of SPCE-based immunosensors, employing the detection of Survival Motor Neuron (SMN) protein, a biomarker associated with Spinal Muscular Atrophy (SMA), as a proof-of-concept application. The resulting platform successfully differentiated specific and non-specific protein recognition events through distinct electrochemical patterns, demonstrating the suitability of gold-modified SPCEs for immunosensing applications. These findings provide insights into the influence of surface engineering strategies on sensor performance and support the future development of optimized electrochemical platforms for biomarker detection.
Open AccessElectrochemical Detection of SMN Protein by Immunosensors: The Role of Surface Modifications in Screen-Printed Carbon Electrodes
Point-of-care (POC) technologies are promising tools to decentralize and accelerate the diagnosis of rare diseases. Among them, electrochemical immunosensors offer advantages such as high sensitivity, low cost, portability, low sample consumption, and suitability for use in resource-limited settings. However, the performance of these devices is dependent on electrode surface properties, which influence electron transfer, biomolecule immobilization, and analytical sensitivity. In this work, screen-printed carbon electrodes (SPCEs) were modified through two strategies: (i) gold electrodeposition and (ii) cold plasma treatment. The modified electrodes were functionalized with EDC/NHS, followed by the immobilization of anti-SMN antibodies and electrochemical characterization using cyclic voltammetry and differential pulse voltammetry. The impact of each modification approach on the electrochemical response and reproducibility of the sensor was evaluated. Gold electrodeposition resulted in higher and more reproducible electrochemical responses, demonstrating improved electron transfer properties and surface homogeneity. The primary objective of this study was to investigate how different surface modification strategies affect the electrochemical performance of SPCE-based immunosensors, employing the detection of Survival Motor Neuron (SMN) protein, a biomarker associated with Spinal Muscular Atrophy (SMA), as a proof-of-concept application. The resulting platform successfully differentiated specific and non-specific protein recognition events through distinct electrochemical patterns, demonstrating the suitability of gold-modified SPCEs for immunosensing applications. These findings provide insights into the influence of surface engineering strategies on sensor performance and support the future development of optimized electrochemical platforms for biomarker detection.
- Open Access
- 16 February 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (8) , 4254-4268
Effect of Beta Nucleating Agent Supported on Zeolite or Graphene Oxide on Polypropylene Membranes for Battery Separator Production
- 16 February 2026
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 65 (8) , 4254-4268
Open AccessEffect of Beta Nucleating Agent Supported on Zeolite or Graphene Oxide on Polypropylene Membranes for Battery Separator Production
- Open Access
- 5 January 2026
- Published by Brazilian Journals in Revista Contemporânea
- Vol. 6 (1) , e10100
SENSORS PRODUCTION: PROCESS STATISTICAL ANALYSIS AND ARTIFICIAL INTELLIGENCE FOR QUALITY CONTROL
Screen printing is an economical, practical, and sustainable alternative for sensor production. Screen-printed carbon electrodes (SPCEs) are a fundamental component of biosensors, which act as diagnostic devices, and therefore need to meet high quality and performance standards. This work aimed to study a company production process of SPCEs through statistical analyses of the process’ failures and the final product's thickness. In addition, it aimed to apply Artificial Intelligence for visual inspection based on machine learning, to automate and accelerate the decision to approve or discard the product. The company provided production data totaling five production batches from March to July (2024). Generalized linear mixed models with a binomial family were used to analyze yield and manufacturing errors, performed in RStudio software (a=0.05). Success proportions were evaluated through their logit values, variance, and confidence interval obtained from the model and logistic distribution. Control and Pareto charts were used to analyze product thickness and manufacturing errors, respectively. Additionally, a computer vision model based on a pre-training neural network was developed in Python for automating the product inspection process using sensor’s images to identify manufacturing errors. It was observed that the screen-printing process had a yield of 41.5%, with the main errors being rejections due to unprinted tracks, tracks wider than standard and paste accumulation during printing. The developed computational model presents itself as a promising tool with 83% efficiency in precision, recall, and F1-Score metrics when tested in the production process.
- 5 January 2026
- Published by Brazilian Journals in Revista Contemporânea
- Vol. 6 (1) , e10100
Open AccessSENSORS PRODUCTION: PROCESS STATISTICAL ANALYSIS AND ARTIFICIAL INTELLIGENCE FOR QUALITY CONTROL
Screen printing is an economical, practical, and sustainable alternative for sensor production. Screen-printed carbon electrodes (SPCEs) are a fundamental component of biosensors, which act as diagnostic devices, and therefore need to meet high quality and performance standards. This work aimed to study a company production process of SPCEs through statistical analyses of the process’ failures and the final product's thickness. In addition, it aimed to apply Artificial Intelligence for visual inspection based on machine learning, to automate and accelerate the decision to approve or discard the product. The company provided production data totaling five production batches from March to July (2024). Generalized linear mixed models with a binomial family were used to analyze yield and manufacturing errors, performed in RStudio software (a=0.05). Success proportions were evaluated through their logit values, variance, and confidence interval obtained from the model and logistic distribution. Control and Pareto charts were used to analyze product thickness and manufacturing errors, respectively. Additionally, a computer vision model based on a pre-training neural network was developed in Python for automating the product inspection process using sensor’s images to identify manufacturing errors. It was observed that the screen-printing process had a yield of 41.5%, with the main errors being rejections due to unprinted tracks, tracks wider than standard and paste accumulation during printing. The developed computational model presents itself as a promising tool with 83% efficiency in precision, recall, and F1-Score metrics when tested in the production process.
- 4 April 2024
- Published by Elsevier in Focus on Powder Coatings
- Vol. 2024 (4)
WEG evolves in Its CDP climate change 2023 assessment
- 4 April 2024
- Published by Elsevier in Focus on Powder Coatings
- Vol. 2024 (4)
WEG evolves in Its CDP climate change 2023 assessment
- 4 April 2024
- Published by Elsevier in Focus on Powder Coatings
- Vol. 2024 (4)
Coating market growth fueled by efficiency demands
- 4 April 2024
- Published by Elsevier in Focus on Powder Coatings
- Vol. 2024 (4)
Coating market growth fueled by efficiency demands
- Top Cited Papers
- 21 March 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 878, 162954
Micro- and nanoplastic toxicity: A review on size, type, source, and test-organism implications
- 21 March 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 878, 162954
Top Cited PapersMicro- and nanoplastic toxicity: A review on size, type, source, and test-organism implications
- 6 August 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 290
Cardanol surfactant/ultrasound-assisted exfoliation of graphite in a water/ethanol solution
- 6 August 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 290
Cardanol surfactant/ultrasound-assisted exfoliation of graphite in a water/ethanol solution
- 1 March 2021
- Published by Elsevier in Materials Today Communications
- Vol. 26
Reduced graphene oxide decorated with Ni-Fe-Mo permalloy obtained by sputtering
- 1 March 2021
- Published by Elsevier in Materials Today Communications
- Vol. 26
Reduced graphene oxide decorated with Ni-Fe-Mo permalloy obtained by sputtering
- 12 September 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (41) , 16367-16373
Organometal-catalyzed synthesis of high molecular weight poly-(l-lactic acid) with a covalently attached imidazolium salt: performance-enhanced reduced graphene oxide–PLLA biomaterials
Herein, we report on the synthesis of imidazolium salt end-functionalized PLLA (PLLA-IS) and its application in the preparation of reduced graphene oxide–PLLA composites. When applying the imidazolium salt 1-(2-hydroxyethyl)-3-methylimidazolium tetrafluoroborate as the initiator, the organometallic Zn(C6F5)2toluene complex polymerized L-lactide into high molecular weight PLLA-IS (Mn up to 56k). The presence of this imidazolium functionality enhanced the PLLA−reduced graphene oxide interaction, which promoted a homogenous dispersion of this filler when applying a solvent casting procedure. Significant improvements in the mechanical properties were achieved, reaching 148% and 105% for the loss and storage moduli, respectively. Besides, the PLLA-IS/rGO-1% composite inhibited the growth of fungal biofilms, including C. tropicalis (43%) and C. albicans (34%). Altogether, these materials exhibit properties for novel applications, including as biomaterials.
- 12 September 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (41) , 16367-16373
Organometal-catalyzed synthesis of high molecular weight poly-(l-lactic acid) with a covalently attached imidazolium salt: performance-enhanced reduced graphene oxide–PLLA biomaterials
Herein, we report on the synthesis of imidazolium salt end-functionalized PLLA (PLLA-IS) and its application in the preparation of reduced graphene oxide–PLLA composites. When applying the imidazolium salt 1-(2-hydroxyethyl)-3-methylimidazolium tetrafluoroborate as the initiator, the organometallic Zn(C6F5)2toluene complex polymerized L-lactide into high molecular weight PLLA-IS (Mn up to 56k). The presence of this imidazolium functionality enhanced the PLLA−reduced graphene oxide interaction, which promoted a homogenous dispersion of this filler when applying a solvent casting procedure. Significant improvements in the mechanical properties were achieved, reaching 148% and 105% for the loss and storage moduli, respectively. Besides, the PLLA-IS/rGO-1% composite inhibited the growth of fungal biofilms, including C. tropicalis (43%) and C. albicans (34%). Altogether, these materials exhibit properties for novel applications, including as biomaterials.