ZZZhihao Zheng

Zhihao Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhihao Zheng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dimensional measurement of anti-stress cone of HV cable joints based on 3D point cloud

    by Zhihao Zheng, Yuqun Gao, Zebin He, Chaoyang Wang, Hao Xie, Guihua Liu

    To solve the problem of automatic measurement of anti-stress cone of high voltage cable joints, a measurement algorithm based on 3D point cloud is proposed. Firstly, denoising and coordinate adjustment of point cloud of a cable joint are realized. Then the characteristic curve model of fitting circle radius indicating structure characteristic of cable joints is constructed by fitting circles with random sample consensus algorithm. After that, the discrete points on the characteristic curve are extracted according to the characteristics such as the fluctuation range of the characteristic curve for straight line fitting and the intersection of the fitted lines is calculated to complete the segmentation of the anti-stress cone area of the cable joint. Finally, the parameter measurement of the anti-stress cone was completed according to the structure of the anti-stress cone, and the error correction post-processing was performed. Two types of cable joint point clouds with standard dimensions and surface defects were used for measurement experiments, the absolute errors of the measurement results are less than 0.2 mm and 1.0 mm respectively, and the relative errors are less than 0.25% and 2% respectively, indicating that the proposed method has high robustness and measurement accuracy, which meet the measurement requirements in engineering practice.


  • Three-dimensional defects detection of high-voltage cable joint based on iterative residual fitting

    by Zhihao Zheng, Jiayin Bian, Yuqun Gao, Shuqi He, Wanzhong Liu, Tao Song, Guihua Liu

    Aiming at the three-dimensional (3D) defects detection of high-voltage cables joint, a method based on iterative residual fitting is proposed. The 3D point cloud data was obtained by reconstructing the laser line projected onto the surface of the high-voltage cable joint. In order to remove noise generated by reconstruction which is located above or below the curve, a simple and effective strategy that the noise can be filtered by the gradient change in the neighborhood is adopted. Then a continuous iterative residual fitting method is proposed to effectively reduce the interference of the defect area on the curve fitting accuracy, thereby obtaining the accurate equation expression of the cable surface curve. By comparing the residual value of the high-voltage cable surface points relative to the fitting curve, the points of the defect area are marked. Finally 3D defect area is extracted through segmentation and clustering. Experiments have verified the effectiveness of the proposed method on artificial standard size defects and real manual ground defects. The absolute error of the depth (height) of artificial standard size defects is less than 0.05 mm. Compared with the traditional cylindrical fitting method, it can be seen that the recognition rate of the proposed method for manually ground defects of high-voltage cable joint is much higher than that of cylinder fitting method.


  • Open Access

    Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter

    by Changfu Chen, Yongxia Han, Junxiang Liu, Wenxiong Mo, Zhao Yuan, Jianning Huang, Haibo Su, Xiancong Zhang, Kaijian Wu

    As one of the key technologies to solve the problem of high short-circuit current, the fault current limiter (FCL) has become a research hotspot in China and abroad. The overvoltage and protection measures of the FCL are the key technologies for its application. Therefore, this paper studies the lightning intruding overvoltage and protection measures for a 500 kV FCL based on a high coupled split reactor (HCSR). Firstly, according to the main topology of the system and the 500 kV HCSR-FCL structure, the lightning intruding overvoltage simulation model of the 500 kV station, including the nearby transmission lines, is established on the PSCAD (Power Systems Computer Aided Design) program. Secondly, the lightning overvoltage of the equipment in the station and the components of the HCSR-FCL are simulated and analyzed when the transmission lines nearby are subjected to lightning shielding failure and back flashover. Meanwhile, the influence of the HCSR-FCL on the lightning overvoltage of the equipment in the station are compared and analyzed before and after the HCSR-FCL is installed. The simulation results show that the overvoltage of the equipment in the station and the components of the HCSR-FCL is more serious when the shielding failure occurs in the transmission lines nearby. The HCSR-FCL can reduce the lightning overvoltage of the equipment in the station, but the maximum inter-terminal and inter-arm lightning overvoltage of the HCSR can reach 1064 kV and 790 kV, respectively, under the current limiting state and the current sharing state. Finally, methods of increasing the arresters on the transmission lines side of the HCSR-FCL and shunt capacitor between each module of the HCSR-FCL are proposed to reduce the lightning overvoltage. The lightning impulse withstand voltage of each component of the HCSR is also proposed: The inter-terminal lightning impulse withstand voltage of HCSR is 170 kV. The inter-arm lightning impulse withstand voltage of HCSR is 200 kV. The terminal-to-ground lightning impulse withstand voltage of the HCSR-FCL is 1550 kV.