AUAbdullah Yousuf Usmani

Abdullah Yousuf Usmani

*This is an algorithmically generated author record based on publicly available information.

Abdullah Yousuf Usmani has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Core Gradation on the Blast Resistance and Progressive Collapse of Bio-Inspired Hierarchical Corrugated Sandwich Panels Under Underwater Explosion

    by Danish Iqbal, M. Kamil Khan, Zaid Mohammad, A. Y. Usmani, M.A. Iqbal

    The dynamic response of bio-inspired hierarchical corrugated sandwich panels subjected to underwater explosion (UNDEX) loading is numerically investigated using a Coupled Eulerian-Lagrangian (CEL) framework validated against published experimental data. The core architecture, inspired by the graded vascular bundle distribution in bamboo, incorporates three levels of hierarchical corrugation arranged in four gradation strategies which were Uniform (UG), Alternate (AG), Increasing (IG), and Decreasing (DG). A parametric study spanning TNT charge masses of 10-40 g and stand-off distances of 60-120 mm is conducted to evaluate the influence of core gradation on transient deformation, facesheet velocity histories, progressive core crushing, layer-wise and specific energy absorption, and failure characteristics. The results reveal that core gradation fundamentally governs the collapse mode from sequential layer-by-layer crushing in UG, selective preferential crushing of lighter interlayers in AG, front-concentrated decelerating crushing in IG, to concurrent multi-layer deformation in DG. The DG configuration reduces front facesheet deflection by up to 46% relative to UG through a spatial separation of load-bearing and energy-absorbing functions, wherein the dense front layers attenuate initial momentum transfer while the lighter rear layers undergo preferential plastic collapse. The findings establish that spatial distribution of energy dissipation across the core depth, rather than its peak magnitude, governs blast mitigation efficacy in hierarchically graded sandwich structures.

  • Pulsatile flow dynamics in an artery with multiple pathologies: A fluid–structure interaction study

    by Priyanshu Soni, Abhra Bhattacharyya, Abdullah Y. Usmani, Sanjay Kumar Rai, B. V. Rathish Kumar

    Cardiovascular diseases are a major cause of premature mortality, often due to arterial stenosis and aneurysms. This study investigates the interplay between hemodynamics and biomechanics in arteries with coexisting stenosis and aneurysms using one-way fluid–structure interaction (FSI) modeling. Three-dimensional artery models with stenosis severities of 50%, 70%, and 90% (cases 1–3) and an eccentric model (case 4) are created, each featuring a 50% downstream aneurysm to examine its interaction with upstream stenosis. The viscoelastic arterial wall, modeled with a 2.5 mm thickness using a generalized Maxwell model, is subjected to physiological pulsatile velocity and pressure profiles to simulate realistic blood flow conditions. FSI analysis captures key hemodynamic indicators along with biomechanical responses, including arterial wall deformation and von Mises stress. Results reveal severe stenosis (>70%) induces intense, persistent vortical structures and promotes pronounced three-dimensional flow disturbances, significantly increasing thrombus risk, aneurysm progression, and localized wall stress, especially in 90% stenosis (case 3). Vortical dynamics become more complex with stenosis severity, as eccentric stenosis introducing asymmetry, leading to wall-adjacent vortex migration and prolonged flow disturbances. Eccentric stenosis (case 4) redistributes shear stress, reducing localized stress concentrations but maintaining complex flow patterns, causing the highest wall deformation of 1.9 mm and peak von Mises stress of 8.8 kPa. Severe stenosis requires urgent medical attention due to increased rupture risk, while eccentricity moderates localized stress yet sustains vascular risks. This study highlights the role of FSI in connecting flow dynamics with arterial biomechanics, aiding in vascular risk assessment and targeted surgical interventions.


  • Effect of a bend on vortex formation and evolution in a three-dimensional stenosed geometry during pulsatile flow

    by Mohammad Owais, Abdullah Y. Usmani, K. Muralidhar

    Stenosis at arterial bends alters hemodynamics and instigates abnormal disease progression. This configuration is addressed numerically by exploring pulsatile flow (Reynolds number Re = 300–1200; Womersley number Wo = 7.62–15.24) in arteries encountering bend angles of θ = 20°–60°. Individual influences of stenosis and bend on flow dynamics are investigated. Validations against particle image velocimetry experiments for Re = 800 and Wo = 7.62 are carried out in straight and 60° bend stenosed models. For Re = 300–800, the shear layer along the stenosis rolls up into a primary vortex, that is, constrained by the outer wall forming a secondary vortex. At Re = 1200, shear layers undergo instabilities along the post-stenotic region and develop new vortices that promote disturbances and induce asymmetries over the cross-plane flow structures. These features are not present in a straight stenosed tube, showing that the bend is responsible for flow distortion. During the pulsatile cycle, increasing bend angles intensify the size and strength of vortices, while these are suppressed at higher frequencies. A higher bend of 60° experiences large time-averaged wall shear stress and oscillatory loads. In time, wall loading spatially circumscribes the post-stenotic region followed by wall loading during cycle deceleration. These features are consistent with the skewing of a three-dimensional ring structure formed in a stenosed tube that evolves into disintegrated structures in the post-stenotic region. Overall, simulations reveal that strongly bent stenosed arteries experience aggravated oscillatory loading. In the biomedical context, such arterial geometries will require special attention.


  • Open Access

    4E analysis of a two-stage refrigeration system through surrogate models based on response surface methods and hybrid grey wolf optimizer

    by Rasel Ahmed, Shuhaimi Mahadzir, Adrián Mota-Babiloni, Al- Amin, Abdullah Yousuf Usmani, Zaid Ashraf Rana, Hayati Yassin, Saboor Shaik, Fayaz Hussain

    Refrigeration systems are complex, non-linear, multi-modal, and multi-dimensional. However, traditional methods are based on a trial and error process to optimize these systems, and a global optimum operating point cannot be guaranteed. Therefore, this work aims to study a two-stage vapor compression refrigeration system (VCRS) through a novel and robust hybrid multi-objective grey wolf optimizer (HMOGWO) algorithm. The system is modeled using response surface methods (RSM) to investigate the impacts of design variables on the set responses. Firstly, the interaction between the system components and their cycle behavior is analyzed by building four surrogate models using RSM. The model fit statistics indicate that they are statistically significant and agree with the design data. Three conflicting scenarios in bi-objective optimization are built focusing on the overall system following the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and Linear Programming Technique for Multidimensional Analysis of Preference (LINMAP) decision-making methods. The optimal solutions indicate that for the first to third scenarios, the exergetic efficiency (EE) and capital expenditure (CAPEX) are optimized by 33.4% and 7.5%, and the EE and operational expenditure (OPEX) are improved by 27.4% and 19.0%. The EE and global warming potential (GWP) are also optimized by 27.2% and 19.1%, where the proposed HMOGWO outperforms the MOGWO and NSGA-II. Finally, the K-means clustering technique is applied for Pareto characterization. Based on the research outcomes, the combined RSM and HMOGWO techniques have proved an excellent solution to simulate and optimize two-stage VCRS.


  • Open Access

    Two-Phase Non-Newtonian Pulsatile Blood Flow Simulations in a Rigid and Flexible Patient-Specific Left Coronary Artery (LCA) Exhibiting Multi-Stenosis

    by Abdulgaphur Athani, Nik Nazri Nik Ghazali, Irfan Anjum Badruddin, Abdullah Y. Usmani, Sarfaraz Kamangar, Ali E. Anqi, Nandalur Ameer Ahammad

    Coronary artery disease (CAD) is stated as one of the most common causes of death all over the world. This article explores the influence of multi stenosis in a flexible and rigid left coronary artery (LCA) model using a multiphase blood flow system which has not yet been studied. Two-way fluid–solid interaction (FSI) is employed to achieve flow within the flexible artery model. A realistic three-dimensional model of multi-stenosed LCA was reconstructed based on computerized tomography (CT) images. The fluid domain was solved using a finite volume-based commercial software (FLUENT 2020). The fluid (blood) and solid (wall) domains were fully coupled by using the ANSYS Fluid-Structure Interaction solver. The maximum pressure drops, and wall shear stress was determined across the sever stenosis (90% AS). The higher region of displacement occurs at the pre-stenosis area compared to the other area of the left coronary artery model. An increase in blood flow velocity across the restricted regions (stenosis) in the LCA was observed, whereas the recirculation zone at the post-stenosis and bifurcation regions was noted. An overestimation of hemodynamic descriptors for the rigid models was found as compared to the FSI models.


  • Unsteady Hemodynamics in Intracranial Aneurysms With Varying Dome Orientations

    by Abdullah Y. Usmani, K. Muralidhar

    Fluid loading within an intracranial aneurysm is difficult to measure but can be related to the shape of the flow passage. The outcome of excessive loading is a fatal hemorrhage, making it necessary for early diagnosis. However, arterial diseases are asymptomatic and clinical assessment is a challenge. A realistic approach to examining the severity of wall loading is from the morphology of the aneurysm itself. Accordingly, this study compares pulsatile flow (Reynolds number Re = 426, Womersley number Wo = 4.7) in three different intracranial aneurysm geometries. Specifically, the spatio-temporal movement of vortices is followed in high aspect ratio aneurysm models whose domes are inclined along with angles of 0, 45, and 90 deg relative to the plane of the parent artery. The study is based on finite volume simulation of unsteady three-dimensional flow while a limited set of particle image velocimetry experiments have been carried out. Within a pulsatile cycle, an increase in inclination (0–90 deg) is seen to shift the point of impingement from the distal end toward the aneurysmal apex. This change in flow pattern strengthens helicity, drifts vortex cores, enhances spatial displacement of the vortex, and generates skewed Dean's vortices on transverse planes. Patches of wall shear stress and wall pressure shift spatially from the distal end in models of low inclination (0–45 deg) and circumscribe the aneurysmal wall for an inclination angle of 90 deg. Accordingly, it is concluded that high angles of inclination increase rupture risks while lower inclinations are comparatively safe.


  • FLOW HEMODYNAMICS WITHIN A BENT ASYMMETRIC STENOSED ARTERY

    by Mohammad Owais, Abdullah Y. Usmani

    The plaque deposition on the arterial wall narrows down the arterial lumen, thus restricting blood flow and altered hemodynamics around the constriction. The bends in the arteries are believed to be potential sites of such deposits. In the present study, pulsatile flow in asymmetrically stenosed arterial models has been numerically simulated. The straight stenosed model is considered and is compared with the 20°, 40° and 60° bend stenosed models. Physiologically relevant inlet pulsatile waveform of Repeak = 300 - 800 and Wo = 7.62-15.24 is considered. Limited PIV experiments have also been performed for 60° bend stenosed artery model to validate numerical results. In comparison to the straight stenosed tube an arterial bend (on the medial plane) reveals larger vortex patterns, diminishes the size of the secondary vortex on the outer wall, disturbed flow patterns in the post-stenotic region and increased vortex strength (d2 values). Cross plane shows large vortex strength during the late diastolic portion of the cycle, being indicative of strong three dimensionality within the flow. With the increased bend angle (θ = 20° to 60°), these trends intensify in conjunction with higher WSS values being experienced at the throat and oscillatory wall loading (OSI ~ 0.5) prevailing along the post-stenotic portion. Time-averaged WSS reveals large recirculation zone, which in turn indicates that a 60° stenosed bend is the most critical from the biomedical point of view.