DCDenis Cecchinato

Denis Cecchinato

*This is an algorithmically generated author record based on publicly available information.

Denis Cecchinato has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biomaterial used to counteract ridge reduction following the removal of adjacent teeth: A randomized controlled multicenter study

    by Denis Cecchinato, Enrico Corrà, Eriberto Bressan, Marika Gervasi, Marco Menoncin, Enrico Savio, Marco Toia

    Background: Alveolar ridge resorption (ARP) is a well‐recognized consequence of tooth extraction, and multiple adjacent extractions may lead to greater ridge reduction than single‐tooth extractions. This multicenter randomized controlled trial aimed to assess ridge remodeling after removing 2 adjacent teeth and whether socket grafting with deproteinized bovine bone mineral with collagen (DBBM‐C) plus a collagen membrane could counteract the ridge reduction. Methods: Forty‐two patients requiring 2 adjacent tooth extractions were randomly assigned to either Test (DBBM‐C graft + collagen membrane) or Control (natural healing). Impressions were taken immediately after extraction and at 6 months, and models were analyzed to measure changes in horizontal ridge width (bucco‐lingual at 3 mm below the crest) and vertical ridge height (buccal and lingual). Results: At 6 months, grafted sites had significantly less ridge reduction than controls. Horizontal ridge width reduction averaged 57.7% in Control versus 23.0% in Test ( p < 0.001). Vertical height loss was also greater in controls (buccal 3.0 mm vs. 1.5 mm; lingual 2.2 mm vs. 1.3 mm; p < 0.001). Both mesial and distal sockets benefited similarly from grafting, with comparable preservation at each site. Conclusion: Filling adjacent extraction sockets with DBBM‐C and covering with a collagen membrane significantly reduced horizontal and vertical alveolar ridge resorption compared to unassisted healing. This approach effectively preserves bone volume after multiple tooth extractions, which may facilitate later implant placement. Plain language summary: When 2 neighboring teeth are removed, the area tends to shrink in width and height as it heals. This bone loss can make it more difficult to place dental implants later. In this study, we tested a method to help maintain the bone after removing 2 adjacent teeth. In the Test group, the empty tooth sockets were filled with a bone graft material (deproteinized bovine bone mineral and collagen) and covered with a collagen membrane. In the Control group, the sites were left to heal physiologically. A total of 42 patients participated, each needing 2 side‐by‐side teeth removed. After 6 months of healing, we compared models of the patients from right after the extractions to those taken 6 months later. The results showed that the group with the bone graft and membrane had much less bone shrinkage than the group without them. The 2 extraction sites in the graft group maintained their bone height and width similarly. In summary, using a bone substitute material and membrane immediately after multiple tooth extractions helped preserve the jawbone, which could make future treatments like dental implants more successful.


  • Fixed Full‐Arch Maxillary Prostheses Supported by Four Versus Six Implants: 5‐Year Results of a Multicenter Randomized Clinical Trial

    by Marco Toia, Cristiano S. Moreira, Debora R. Dias, Enrico Corrà, Andrea Ravidà, Denis Cecchinato

    Objectives: This 5‐year multicenter randomized clinical trial assessed the non‐inferiority of maxillary implant‐supported fixed complete dentures (FCDs) with four (4‐I) compared to six implants (6‐I) in terms of radiographic marginal bone level (MBL) changes after 5 years in function.Materials and Methods: Individuals were randomly assigned to the 4‐I or 6‐I groups. Follow‐ups occurred at 1, 3, and 5 years. At each visit, FCDs were unscrewed, clinical parameters (plaque index, bleeding on probing, pocket depth, and keratinized mucosa width) were recorded using a periodontal probe, periapical radiographs were obtained, and maintenance care was performed. MBL changes, incidence of techincal, prosthetic, and biological complications, treatments costs, and satisfaction were evaluated.Results: Of 47 patients rehabiliated with 233 implants, survival rates were 99.3% for 6‐I and 100% for 4‐I (one early failure; 6‐I group). No significant MBL differences were observed at 5 years between and within the groups. Both groups showed a decrease in keratinized mucosa width and experienced prosthetic and biological complications, but no peri‐implantitis. The 4‐I exhibited a significantly higher incidence of technical complications (16.6% vs. 0%) Cost analysis favored 4‐I for initial and total costs. Clinician and patient satisfaction varied, with 4‐I preferred aesthetically and 6‐I functionally, particularly in speaking ability at earlier follow‐ups.Conclusion: The use of FCDs supported by four implants is non‐inferior to six implants in terms of radiographic MBL changes after 5 years in function. Both groups demonstrated comparable survival rates and incidence of biological and prosthetic complications. The 4‐I was associated with higher technical complications and reduced overall treatment cost.Trial Registration: ClinicalTrials.gov identifier: NCT02405169


  • Open Access

    6 mm short versus 11 mm long inter‐foraminal implants in the full‐arch rehabilitation of edentulous non‐atrophic mandibles: 5‐year results from a multicenter randomized controlled trial

    by Luigi Guida, Umberto Esposito, Massimiliano Sirignano, Paolo Torrisi, Marco Annunziata, Denis Cecchinato

    ObjectiveThe aim of this multicenter parallel-group randomized controlled trial is to compare, in the same clinical scenario, 6 mm short with 11 mm long implants for the rehabilitation of completely edentulous non-atrophic mandibles. Materials and MethodsThirty patients in three study centers received a fixed full-arch mandibular rehabilitation supported by five inter-foraminal implants, with no need for bone augmentation procedures. Patients were randomly allocated (1:1 ratio), at the time of surgery, to test (6 mm implants) or control group (11 mm implants). After 3 months, a screw-retained full-arch prosthesis was positioned (baseline). Peri-implant marginal bone level change (MBLc, primary outcome) together with implant and prosthesis survival rate, and biological/technical complications (secondary outcomes) were evaluated up to 5 years. ResultsTwenty seven patients were controlled at 5 years (3 drop-outs). No implant or prosthesis loss occurred. No significant intergroup difference for biological/technical complications (p > .05, Fisher's exact test) and no significant intragroup and intergroup difference in the MBLc values were registered (test -0.03 +/- 0.17 mm and control -0.13 +/- 0.32 mm at 5-years; p > .025, one-sided Mann-Whitney U-test). ConclusionsWhen used in comparable anatomic, surgical, and prosthetic conditions, no difference in the clinical and radiographic outcomes between 6-mm and 11-mm implants was observed at 5 years of follow-up. Short implants showed to be a reliable option for the rehabilitation of completely edentulous non-atrophic mandibles. There is growing clinical evidence supporting the use of short implants, even in the case of non-atrophic sites.


  • Occurrence of complications in patients restored with implants

    by Denis Cecchinato, Massimiliano Marino, Jan Håkansson, Jan Lindhe, Jan Derks

    Objectives: To determine the occurrence and clustering of complications in subjects restored with fixed implant‐supported prostheses.Methods: In the present retrospective case series, 241 subjects treated at one clinical centre and provided with 729 implants were included. A clinical and radiographic examination was performed after a mean follow‐up period of 4.8 ± 2.0 years. Additional information on occurrence of technical (chipping, loss of retention, fracture of components) and biological complications (marginal bone loss, implant loss) during follow‐up was extracted from patient records. For each type of complication and complications overall, regression analyses were performed to identify potential risk factors. Cox regression analyses were used to evaluate time to event for implant loss and technical complications.Results: In all, 30% of the 241 patients presented with at least one complication of technical and/or biological character during the follow‐up period. Technical complications affected 19.5% of subjects, while 14.1% presented with marginal bone loss >2 mm. Implant loss occurred in 4.6% of subjects. While technical complications were noted already early during the maintenance period (<1200 days), implant loss typically occurred during a later phase. A small subgroup of subjects (7.9%) experienced more than one type of complication.Conclusions: Complications occurred frequently and the most common type of complication was of technical character. Technical and biological complications occurred independently of each other.


  • Fixed full‐arch maxillary prostheses supported by four versus six implants with a titanium CAD/CAM milled framework: 3‐year multicentre RCT

    by Marco Toia, Michele Stocchero, Enrico Corrà, Jonas P. Becktor, Ann Wennerberg, Denis Cecchinato

    Objectives: This RCT compares marginal bone level (MBL) change and the clinical parameters after a 3‐year function in maxillary implant‐supported fixed complete dentures (FCDs) treated with four‐implants (4‐I) or six‐implants (6‐I).Material and method: Three centres treated 56 patients with 280 implants allocated to the 4‐I or 6‐I group. Radiographic and clinical examinations were performed. The primary outcome was to investigate MBL change between the groups.Results: Implant survival rates were 100% and 99% in the 4‐I and 6‐I groups, respectively. Considering the clustering effects, the MBL change was not significantly different between the groups over the 3‐year follow‐up. The MBL in the 4‐I group was 0.30 ± 0.50 mm at baseline, 0.24 ± 0.31 mm at 1 year and 0.24 ± 0.38 mm at 3 years. In the 6‐I group, MBL was 0.14 ± 0.32 mm at baseline, 0.16 ± 0.35 mm at 1 year and 0.12 ± 0.26 mm at 3 years. There was a statistically significant difference between the groups at BL and 3Y. No significant differences between the groups were reported for clinical parameters at each time point as well as in between the visits. The technical and biological complications rates were 1.6% and 6.0%, respectively. Prosthetic complications affected 25 FCDs (47.2%).Conclusion: Marginal bone level change revealed a stable condition in the 3‐year period in the two groups. Few technical and biological complications occurred apart from the chipping/fracture of the prosthetic teeth. Four‐implant is a feasible solution if the rehabilitation is oriented towards the most cost‐effective treatment and towards avoiding bone augmentation procedures. Clinicians have to consider the potential required visits for prosthetic maintenance.


  • 6‐mm‐short and 11‐mm‐long implants compared in the full‐arch rehabilitation of the edentulous mandible: A 3‐year multicenter randomized controlled trial

    by Luigi Guida, Marco Annunziata, Umberto Esposito, Massimiliano Sirignano, Paolo Torrisi, Denis Cecchinato

    Objective: The aim of this multicenter parallel‐group randomized controlled trial is to compare 6‐mm‐short with 11‐mm‐long implants in the rehabilitation of totally edentulous mandible in a completely comparable clinical situation, from anatomical, surgical, and prosthetic point of view.Material and methods: Thirty patients were selected in three study centers to receive a fixed full‐arch mandibular rehabilitation supported by five inter‐foraminal implants. Patients were randomly allocated, at the time of surgery, half to the test group (6‐mm‐long implants) and half to the control group (11‐mm‐long implants). No bone augmentation procedure was performed. After 3 months, a screw‐retained full‐arch prosthesis with distal cantilevers was positioned (baseline). Peri‐implant marginal bone level change (MBLc), implant and prosthesis survival rate, and biological/technical complications were evaluated after 1 and 3 years.Results: Thirty subjects (150 implants) were evaluated after 1 year and 28 (140 implants) after 3 years. No implant or prosthesis loss occurred. No significant inter‐group difference for biological/technical complications was registered. No statistically significant (p > .025) intra‐group or inter‐group difference in the mean MBLc values was registered. The mean MBLc was 0.01 ± 0.19 mm and −0.04 ± 0.21 mm at 1 year, and −0.10 ± 0.24 mm and 0.02 ± 0.25 mm at 3 years (test and control groups, respectively).Conclusions: 6‐mm‐short implants may be a reliable option when used in the rehabilitation of total edentulous mandibles. These results need to be confirmed by longer follow‐up data from well‐designed randomized controlled clinical trials.


  • Effect of socket grafting with deproteinized bone mineral: An RCT on dimensional alterations after 6 months

    by Cristiano Tomasi, Mauro Donati, Denis Cecchinato, Isacco Szathvary, Enrico Corrà, Jan Lindhe

    Objective: To examine if (i) characteristics of the fresh extraction socket site influenced subsequent dimensional alterations and (ii) placement of deproteinized bovine mineral in the socket affected volumetric change during healing.Materials and methods: Twenty seven subjects and 28 extraction sites were included. Immediately after the removal of the tooth and after 6 months of healing, stone and virtual models of the jaw were produced. A cone beam computerized tomography scan was obtained immediately after extraction and the thickness of the buccal bone wall at the extraction site was measured. Extraction sites were randomly assigned to test or control group. In the test group, extraction sockets were filled with deproteinized bone mineral and covered with a collagen membrane. In the control group, only a collagen membrane was placed.Results: The thickness of the buccal bone wall at the extraction site influenced the amount of volume reduction that occurred. Socket grafting influenced the degree of ridge diminution only at sites where the buccal bone wall was thin (≤ 1 mm).Conclusion: A graft comprised of collagen‐enriched deproteinized bovine bone mineral, placed to fill extraction sockets failed to influence the overall diminution of the ridge that occurred during healing. The thickness of the buccal bone wall apparently had a significant influence on volumetric alterations of the edentulous ridge following tooth extraction.


  • Bone loss at implants and teeth in the same inter‐proximal unit: A radiographic study

    by Denis Cecchinato, Massimiliano Marino, Marco Toia, Francesca Cecchinato, Jan Lindhe

    Objective: This study was performed to determine whether the distance between an implant and a tooth present in an inter‐proximal unit influenced the amount of marginal bone loss that occurred at the two facing (adjacent) surfaces.Materials and methods: One hundred and eighty patients with a total of 278 inter‐proximal units were included. Radiographs of implants that also included adjacent (facing) natural tooth/teeth were digitalized, and various linear measurements were performed using a software program. The marginal bone level and the bone level change that had occurred during a mean of 5.8 years were assessed as well as distance between the implant and the adjacent tooth/teeth.Results: The mean amount of additional marginal bone loss that took place during the observation period was about 0.4 mm at both implants and adjacent tooth surfaces. The horizontal distance between an implant and the facing tooth did not influence the amount of marginal bone loss that had occurred. In most inter‐proximal units, more advanced bone loss (>1 mm, >2 mm) had ensued either at the implant or at the facing tooth surface. Advanced additional bone loss occurred at both the implant and the tooth in only about 3% of the examined subjects.Conclusion: Bone loss at implants and teeth appears to be a site‐specific phenomenon and not dependent on the inter‐proximal distance.


  • A prospective, randomized, controlled study using OsseoSpeed™ implants placed in maxillary fresh extraction socket: soft tissues response

    by Denis Cecchinato, Diego Lops, Giovanni E. Salvi, Mariano Sanz

    Purpose: The aim of this work was to study the peri‐implant soft tissues response, by evaluating both the recession and the papilla indexes, of patients treated with implants with two different configurations. In addition, data were stratified by tooth category, smoking habit and thickness of buccal bone wall.Materials and methods: The clinical trial was designed as a prospective, randomized‐controlled multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15–25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical or conical/cylindrical implant. The following parameters were studied: (i) Soft tissue recession (REC) measured by comparing the gingival zenith (GZ) score at baseline (permanent restoration) with that of the yearly follow‐up visits over a period of 3 years (V1, V2 and V3). (ii) Interdental Papilla Index (PI): PI measurements were performed at baseline and compared with that of the follow‐up visits. In addition, data were stratified by different variables: tooth category: anterior (incisors and canine) and posterior (first and second premolar); smoking habit: patient smoker (habitual or occasional smoker at inclusion) or non‐smoker (non‐smoker or ex‐smoker at inclusion) and thickness of buccal bone wall (TB): TB ≤ 1 mm (thin buccal wall) or TB > 1 mm (thick buccal wall).Results: A total of 93 patients were treated with 93 implants. At the surgical re‐entry one implant was mobile and then removed; moreover, one patient was lost to follow‐up. Ninety‐one patients were restored with 91 implant‐supported permanent single crowns. After the 3‐year follow‐up, a mean gain of 0.23 mm of GZ was measured; moreover, 79% and 72% of mesial and distal papillae were classified as >50%/ complete, respectively. From the stratification analysis, not significant differences were found between the mean GZ scores of implants with TB ≤ 1 mm (thin buccal wall) and TB > 1 mm (thick buccal wall), respectively (P < 0.05, Mann–Whitney U‐test) at baseline, at V1, V2 and V3 follow‐up visits. Also, the other variables did not seem to influence GZ changes over the follow‐up period. Moreover, a re‐growth of the interproximal mesial and distal papillae was the general trend observed independently from the variables studied.Conclusions: Immediate single implant treatment may be considered a predictable option regarding soft tissue stability over a period of 3 years of follow‐up. An overall buccal soft tissue stability was observed during the GZ changes from the baseline to the 3 years of follow‐up with a mean GZ reduction of 0.23 mm. A nearly full papillary re‐growth can be detectable over a minimum period of 2 years of follow‐up for both cylindrical and conical/cylindrical implants. Both the interproximal papilla filling and the midfacial mucosa stability were not influenced by variables such as type of fixture configuration, tooth category, smoke habit, and thickness of buccal bone wall of ≤ 1 mm (thin buccal wall).