Gian Marco Melito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gian Marco Melito has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Alice Reinbacher-Köstinger
Institute of Fundamentals and Theory in Electrical Engineering, Graz University of Technology, Inffeldgasse 18, 8010 Graz, Austria
4 shared publications - Alireza Jafarinia
Institute of Strength of Materials, Graz University of Technology, 8010 Graz, Austria
4 shared publications - Katrin Ellermann
Graz University of Technology
4 shared publications - Vahid Badeli
Institute of Fundamentals and Theory in Electrical Engineering, Graz University of Technology, 8010 Graz, Austria
4 shared publications Katrin Ellermann
Faculty of Mathematics, Ruhr University Bochum, Bochum, Germany
3 shared publications- Günter Brenn
Institute of Fluid Mechanics and Heat Transfer, Graz University of Technology, 8010 Graz, Austria
2 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Elsevier in Computers and Geotechnics
- Vol. 203
Surrogate models for forward simulation and inverse parameter identification using numerical cone penetration test data
- 25 October 2026
- Published by Elsevier in Computers and Geotechnics
- Vol. 203
Open AccessSurrogate models for forward simulation and inverse parameter identification using numerical cone penetration test data
- Open Access
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (1) , 421-430
SynthAorta: A 3D Mesh Dataset of Parametrized Physiological Healthy Aortas
The effects of the aortic geometry on its mechanics and blood flow, and subsequently on aortic pathologies, remain largely unexplored. The main obstacle lies in obtaining patient-specific aorta models, an extremely difficult procedure in terms of ethics and availability, segmentation, mesh generation, and all of the accompanying processes. Contrastingly, idealized models are easy to build but do not faithfully represent patient-specific variability. Additionally, a unified aortic parametrization in clinic and engineering has not yet been achieved. To bridge this gap, we introduce a new set of statistical parameters to generate synthetic models of the aorta. The parameters possess geometric significance and fall within physiological ranges, effectively bridging the disciplines of clinical medicine and engineering. Smoothly blended realistic representations are recovered with convolution surfaces. These enable high-quality visualization and biological appearance, whereas the structured mesh generation paves the way for numerical simulations. The only requirement of the approach is one patient-specific aorta model and the statistical data for parameter values obtained from the literature. The output of this work is SynthAorta, a dataset of ready-to-use synthetic, physiological aorta models, each containing a centerline, surface representation, and a structured hexahedral finite element mesh. The meshes are structured and fully consistent between different cases, making them imminently suitable for reduced order modeling and machine learning approaches.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (1) , 421-430
Open AccessSynthAorta: A 3D Mesh Dataset of Parametrized Physiological Healthy Aortas
The effects of the aortic geometry on its mechanics and blood flow, and subsequently on aortic pathologies, remain largely unexplored. The main obstacle lies in obtaining patient-specific aorta models, an extremely difficult procedure in terms of ethics and availability, segmentation, mesh generation, and all of the accompanying processes. Contrastingly, idealized models are easy to build but do not faithfully represent patient-specific variability. Additionally, a unified aortic parametrization in clinic and engineering has not yet been achieved. To bridge this gap, we introduce a new set of statistical parameters to generate synthetic models of the aorta. The parameters possess geometric significance and fall within physiological ranges, effectively bridging the disciplines of clinical medicine and engineering. Smoothly blended realistic representations are recovered with convolution surfaces. These enable high-quality visualization and biological appearance, whereas the structured mesh generation paves the way for numerical simulations. The only requirement of the approach is one patient-specific aorta model and the statistical data for parameter values obtained from the literature. The output of this work is SynthAorta, a dataset of ready-to-use synthetic, physiological aorta models, each containing a centerline, surface representation, and a structured hexahedral finite element mesh. The meshes are structured and fully consistent between different cases, making them imminently suitable for reduced order modeling and machine learning approaches.
- 10 February 2024
- Published by Springer Nature
- p. 110-126
Optimizing Aortic Segmentation with an Innovative Quality Assessment: The Role of Global Sensitivity Analysis
- 10 February 2024
- Published by Springer Nature
- p. 110-126
Optimizing Aortic Segmentation with an Innovative Quality Assessment: The Role of Global Sensitivity Analysis
- Open Access
- 1 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 147
Modeling Anisotropic Electrical Conductivity of Blood: Translating Microscale Effects of Red Blood Cell Motion into a Macroscale Property of Blood
Cardiovascular diseases are a leading global cause of mortality. The current standard diagnostic methods, such as imaging and invasive procedures, are relatively expensive and partly connected with risks to the patient. Bioimpedance measurements hold the promise to offer rapid, safe, and low-cost alternative diagnostic methods. In the realm of cardiovascular diseases, bioimpedance methods rely on the changing electrical conductivity of blood, which depends on the local hemodynamics. However, the exact dependence of blood conductivity on the hemodynamic parameters is not yet fully understood, and the existing models for this dependence are limited to rather academic flow fields in straight pipes or channels. In this work, we suggest two closely connected anisotropic electrical conductivity models for blood in general three-dimensional flows, which consider the orientation and alignment of red blood cells (RBCs) in shear flows. In shear flows, RBCs adopt preferred orientations through a rotation of their membrane known as tank-treading motion. The two models are built on two different assumptions as to which hemodynamic characteristic determines the preferred orientation. The models are evaluated in two example simulations of blood flow. In a straight rigid vessel, the models coincide and are in accordance with experimental observations. In a simplified aorta geometry, the models yield different results. These differences are analyzed quantitatively, but a validation of the models with experiments is yet outstanding.
- 1 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 147
Open AccessModeling Anisotropic Electrical Conductivity of Blood: Translating Microscale Effects of Red Blood Cell Motion into a Macroscale Property of Blood
Cardiovascular diseases are a leading global cause of mortality. The current standard diagnostic methods, such as imaging and invasive procedures, are relatively expensive and partly connected with risks to the patient. Bioimpedance measurements hold the promise to offer rapid, safe, and low-cost alternative diagnostic methods. In the realm of cardiovascular diseases, bioimpedance methods rely on the changing electrical conductivity of blood, which depends on the local hemodynamics. However, the exact dependence of blood conductivity on the hemodynamic parameters is not yet fully understood, and the existing models for this dependence are limited to rather academic flow fields in straight pipes or channels. In this work, we suggest two closely connected anisotropic electrical conductivity models for blood in general three-dimensional flows, which consider the orientation and alignment of red blood cells (RBCs) in shear flows. In shear flows, RBCs adopt preferred orientations through a rotation of their membrane known as tank-treading motion. The two models are built on two different assumptions as to which hemodynamic characteristic determines the preferred orientation. The models are evaluated in two example simulations of blood flow. In a straight rigid vessel, the models coincide and are in accordance with experimental observations. In a simplified aorta geometry, the models yield different results. These differences are analyzed quantitatively, but a validation of the models with experiments is yet outstanding.
- Open Access
- 11 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (3) , 885-904
Morphological parameters affecting false lumen thrombosis following type B aortic dissection: a systematic study based on simulations of idealized models
Type B aortic dissection (TBAD) carries a high risk of complications, particularly with a partially thrombosed or patent false lumen (FL). Therefore, uncovering the risk factors leading to FL thrombosis is crucial to identify high-risk patients. Although studies have shown that morphological parameters of the dissected aorta are related to FL thrombosis, often conflicting results have been reported. We show that recent models of thrombus evolution in combination with sensitivity analysis methods can provide valuable insights into how combinations of morphological parameters affect the prospect of FL thrombosis. Based on clinical data, an idealized geometry of a TBAD is generated and parameterized. After implementing the thrombus model in computational fluid dynamics simulations, a global sensitivity analysis for selected morphological parameters is performed. We then introduce dimensionless morphological parameters to scale the results to individual patients. The sensitivity analysis demonstrates that the most sensitive parameters influencing FL thrombosis are the FL diameter and the size and location of intimal tears. A higher risk of partial thrombosis is observed when the FL diameter is larger than the true lumen diameter. Reducing the ratio of the distal to proximal tear size increases the risk of FL patency. In summary, these parameters play a dominant role in classifying morphologies into patent, partially thrombosed, and fully thrombosed FL. In this study, we point out the predictive role of morphological parameters for FL thrombosis in TBAD and show that the results are in good agreement with available clinical studies.
- 11 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (3) , 885-904
Open AccessMorphological parameters affecting false lumen thrombosis following type B aortic dissection: a systematic study based on simulations of idealized models
Type B aortic dissection (TBAD) carries a high risk of complications, particularly with a partially thrombosed or patent false lumen (FL). Therefore, uncovering the risk factors leading to FL thrombosis is crucial to identify high-risk patients. Although studies have shown that morphological parameters of the dissected aorta are related to FL thrombosis, often conflicting results have been reported. We show that recent models of thrombus evolution in combination with sensitivity analysis methods can provide valuable insights into how combinations of morphological parameters affect the prospect of FL thrombosis. Based on clinical data, an idealized geometry of a TBAD is generated and parameterized. After implementing the thrombus model in computational fluid dynamics simulations, a global sensitivity analysis for selected morphological parameters is performed. We then introduce dimensionless morphological parameters to scale the results to individual patients. The sensitivity analysis demonstrates that the most sensitive parameters influencing FL thrombosis are the FL diameter and the size and location of intimal tears. A higher risk of partial thrombosis is observed when the FL diameter is larger than the true lumen diameter. Reducing the ratio of the distal to proximal tear size increases the risk of FL patency. In summary, these parameters play a dominant role in classifying morphologies into patent, partially thrombosed, and fully thrombosed FL. In this study, we point out the predictive role of morphological parameters for FL thrombosis in TBAD and show that the results are in good agreement with available clinical studies.
- Open Access
- 1 September 2021
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 213
Sensitivity analysis study on the effect of the fluid mechanics assumptions for the computation of electrical conductivity of flowing human blood
- 1 September 2021
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 213
Open AccessSensitivity analysis study on the effect of the fluid mechanics assumptions for the computation of electrical conductivity of flowing human blood
- Open Access
- 1 January 2021
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 7 (1) , 31-40
Sensitivity Analysis of a Phenomenological Thrombosis Model and Growth Rate Characterisation
Volume 7, Issue 1 published for JBEB Journal.
- 1 January 2021
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 7 (1) , 31-40
Open AccessSensitivity Analysis of a Phenomenological Thrombosis Model and Growth Rate Characterisation
Volume 7, Issue 1 published for JBEB Journal.
- Open Access
Bayesian Uncertainty Quantification with Multi-Fidelity Data and Gaussian Processes for Impedance Cardiography of Aortic Dissection
In 2000, Kennedy and O’Hagan proposed a model for uncertainty quantification that combines data of several levels of sophistication, fidelity, quality, or accuracy, e.g., a coarse and a fine mesh in finite-element simulations. They assumed each level to be describable by a Gaussian process, and used low-fidelity simulations to improve inference on costly high-fidelity simulations. Departing from there, we move away from the common non-Bayesian practice of optimization and marginalize the parameters instead. Thus, we avoid the awkward logical dilemma of having to choose parameters and of neglecting that choice’s uncertainty. We propagate the parameter uncertainties by averaging the predictions and the prediction uncertainties over all the possible parameters. This is done analytically for all but the nonlinear or inseparable kernel function parameters. What is left is a low-dimensional and feasible numerical integral depending on the choice of kernels, thus allowing for a fully Bayesian treatment. By quantifying the uncertainties of the parameters themselves too, we show that “learning” or optimising those parameters has little meaning when data is little and, thus, justify all our mathematical efforts. The recent hype about machine learning has long spilled over to computational engineering but fails to acknowledge that machine learning is a big data problem and that, in computational engineering, we usually face a little data problem. We devise the fully Bayesian uncertainty quantification method in a notation following the tradition of E.T. Jaynes and find that generalization to an arbitrary number of levels of fidelity and parallelisation becomes rather easy. We scrutinize the method with mock data and demonstrate its advantages in its natural application where high-fidelity data is little but low-fidelity data is not. We then apply the method to quantify the uncertainties in finite element simulations of impedance cardiography of aortic dissection. Aortic dissection is a cardiovascular disease that frequently requires immediate surgical treatment and, thus, a fast diagnosis before. While traditional medical imaging techniques such as computed tomography, magnetic resonance tomography, or echocardiography certainly do the job, Impedance cardiography too is a clinical standard tool and promises to allow earlier diagnoses as well as to detect patients that otherwise go under the radar for too long.
Open AccessBayesian Uncertainty Quantification with Multi-Fidelity Data and Gaussian Processes for Impedance Cardiography of Aortic Dissection
In 2000, Kennedy and O’Hagan proposed a model for uncertainty quantification that combines data of several levels of sophistication, fidelity, quality, or accuracy, e.g., a coarse and a fine mesh in finite-element simulations. They assumed each level to be describable by a Gaussian process, and used low-fidelity simulations to improve inference on costly high-fidelity simulations. Departing from there, we move away from the common non-Bayesian practice of optimization and marginalize the parameters instead. Thus, we avoid the awkward logical dilemma of having to choose parameters and of neglecting that choice’s uncertainty. We propagate the parameter uncertainties by averaging the predictions and the prediction uncertainties over all the possible parameters. This is done analytically for all but the nonlinear or inseparable kernel function parameters. What is left is a low-dimensional and feasible numerical integral depending on the choice of kernels, thus allowing for a fully Bayesian treatment. By quantifying the uncertainties of the parameters themselves too, we show that “learning” or optimising those parameters has little meaning when data is little and, thus, justify all our mathematical efforts. The recent hype about machine learning has long spilled over to computational engineering but fails to acknowledge that machine learning is a big data problem and that, in computational engineering, we usually face a little data problem. We devise the fully Bayesian uncertainty quantification method in a notation following the tradition of E.T. Jaynes and find that generalization to an arbitrary number of levels of fidelity and parallelisation becomes rather easy. We scrutinize the method with mock data and demonstrate its advantages in its natural application where high-fidelity data is little but low-fidelity data is not. We then apply the method to quantify the uncertainties in finite element simulations of impedance cardiography of aortic dissection. Aortic dissection is a cardiovascular disease that frequently requires immediate surgical treatment and, thus, a fast diagnosis before. While traditional medical imaging techniques such as computed tomography, magnetic resonance tomography, or echocardiography certainly do the job, Impedance cardiography too is a clinical standard tool and promises to allow earlier diagnoses as well as to detect patients that otherwise go under the radar for too long.
- Open Access
- 9 December 2019
- Published by MDPI AG in Proceedings
- Vol. 33 (1) , 24
On the Diagnosis of Aortic Dissection with Impedance Cardiography: A Bayesian Feasibility Study Framework with Multi-Fidelity Simulation Data
Aortic dissection is a cardiovascular disease with a disconcertingly high mortality. When it comes to diagnosis, medical imaging techniques such as Computed Tomography, Magnetic Resonance Tomography or Ultrasound certainly do the job, but also have their shortcomings. Impedance cardiography is a standard method to monitor a patients heart function and circulatory system by injecting electric currents and measuring voltage drops between electrode pairs attached to the human body. If such measurements distinguished healthy from dissected aortas, one could improve clinical procedures. Experiments are quite difficult, and thus we investigate the feasibility with finite element simulations beforehand. In these simulations, we find uncertain input parameters, e.g., the electrical conductivity of blood. Inference on the state of the aorta from impedance measurements defines an inverse problem in which forward uncertainty propagation through the simulation with vanilla Monte Carlo demands a prohibitively large computational effort. To overcome this limitation, we combine two simulations: one simulation with a high fidelity and another simulation with a low fidelity, and low and high computational costs accordingly. We use the inexpensive low-fidelity simulation to learn about the expensive high-fidelity simulation. It all boils down to a regression problem—and reduces total computational cost after all.
- 9 December 2019
- Published by MDPI AG in Proceedings
- Vol. 33 (1) , 24
Open AccessOn the Diagnosis of Aortic Dissection with Impedance Cardiography: A Bayesian Feasibility Study Framework with Multi-Fidelity Simulation Data
Aortic dissection is a cardiovascular disease with a disconcertingly high mortality. When it comes to diagnosis, medical imaging techniques such as Computed Tomography, Magnetic Resonance Tomography or Ultrasound certainly do the job, but also have their shortcomings. Impedance cardiography is a standard method to monitor a patients heart function and circulatory system by injecting electric currents and measuring voltage drops between electrode pairs attached to the human body. If such measurements distinguished healthy from dissected aortas, one could improve clinical procedures. Experiments are quite difficult, and thus we investigate the feasibility with finite element simulations beforehand. In these simulations, we find uncertain input parameters, e.g., the electrical conductivity of blood. Inference on the state of the aorta from impedance measurements defines an inverse problem in which forward uncertainty propagation through the simulation with vanilla Monte Carlo demands a prohibitively large computational effort. To overcome this limitation, we combine two simulations: one simulation with a high fidelity and another simulation with a low fidelity, and low and high computational costs accordingly. We use the inexpensive low-fidelity simulation to learn about the expensive high-fidelity simulation. It all boils down to a regression problem—and reduces total computational cost after all.
- Open Access
- 8 October 2019
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 19 (1)
Sensitivity Analysis for Electrical Detection of Aortic Dissection
In medical and patient‐specific applications, uncertainty quantification and sensitivity analysis are indispensable in the process of diagnosis and decision‐making. For the identification of an aortic dissection, a 3D FEM model is used to simulate an appropriate measurement setup. Based on this model, a method to evaluate the uncertainty distribution of a pre‐defined parameter set is proposed. In particular, sensitivity analysis is divided into two steps. The first step involves an initial screening using the Morris method. In the second step, a sensitivity analysis is performed through a variance‐based setting. Here, Polynomial Chaos Expansion (PCE) surrogate model is used. Subsequent post‐processing on the study allows the computation of the representative sensitivity indices.
- 8 October 2019
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 19 (1)
Open AccessSensitivity Analysis for Electrical Detection of Aortic Dissection
In medical and patient‐specific applications, uncertainty quantification and sensitivity analysis are indispensable in the process of diagnosis and decision‐making. For the identification of an aortic dissection, a 3D FEM model is used to simulate an appropriate measurement setup. Based on this model, a method to evaluate the uncertainty distribution of a pre‐defined parameter set is proposed. In particular, sensitivity analysis is divided into two steps. The first step involves an initial screening using the Morris method. In the second step, a sensitivity analysis is performed through a variance‐based setting. Here, Polynomial Chaos Expansion (PCE) surrogate model is used. Subsequent post‐processing on the study allows the computation of the representative sensitivity indices.