PKPiotr Kunicki

Piotr Kunicki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Piotr Kunicki has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrical, thermal and noise properties of platinum-carbon free-standing nanowires designed as nanoscale resistive thermal devices

    by Tomasz Piasecki, Krzysztof Kwoka, Ewelina Gacka, Piotr Kunicki, Teodor Gotszalk

    Platinum-carbon (PtC) composite nanowires were fabricated using focused electron beam induced deposition and postprocessed, and their performance as a nanoscale resistive thermal device (RTD) was evaluated. Nanowires were free-standing and deposited on a dedicated substrate to eliminate the influence of the substrate itself and of the halo effect on the results. The PtC free-standing nanowires were postprocessed to lower their electrical resistance using electron beam irradiation and thermal annealing using Joule heat both separately and combined. Postprocessed PtC free-standing nanowires were characterized to evaluate their noise figure (NF) and thermal coefficients at the temperature range from 30 K to 80 °C. The thermal sensitivity of RTD was lowered with the reduced resistance but simultaneously the NF improved, especially with electron-beam irradiation. The temperature measurement resolution achievable with the PtC free-standing nanowires was 0.1 K in 1 kHz bandwidth.


  • Open Access

    Integration of Fluorescent, NV-Rich Nanodiamond Particles with AFM Cantilevers by Focused Ion Beam for Hybrid Optical and Micromechanical Devices

    by Mateusz Ficek, Maciej J. Głowacki, Krzysztof Gajewski, Piotr Kunicki, Ewelina Gacka, Krystian Sycz, Mariusz Mrózek, Adam M. Wojciechowski, Teodor P. Gotszalk, Wojciech Gawlik, et al.

    In this paper, a novel fabrication technology of atomic force microscopy (AFM) probes integrating cantilever tips with an NV-rich diamond particle is presented. Nanomanipulation techniques combined with the focused electron beam-induced deposition (FEBID) procedure were applied to position the NV-rich diamond particle on an AFM cantilever tip. Ultrasonic treatment of nanodiamond suspension was applied to reduce the size of diamond particles for proper geometry and symmetry. The fabricated AFM probes were tested utilizing measurements of the electrical resistance at highly oriented pyrolytic graphite (HOPG) and compared with a standard AFM cantilever performance. The results showed novel perspectives arising from combining the functionalities of a scanning AFM with optically detected magnetic resonance (ODMR). In particular, it offers enhanced magnetometric sensitivity and the nanometric resolution.


  • Open Access

    Near-zero contact force atomic force microscopy investigations using active electromagnetic cantilevers

    by B Świadkowski, W Majstrzyk, P Kunicki, A Sierakowski, T Gotszalk

    Atomic force microscopy (AFM) belongs to the high resolution and high sensitivity surface imaging technologies. In this method force interactions between the tip and the surface are observed to characterize sample properties. In the so-called contact AFM (C AFM) mode the tip is brought into continuous contact with the sample. Significant progress in the AFM technology can be obtained, when the so-called active cantilever technology is implemented in the surface measurements. The built-in deflection actuator enables very precise excitation of the cantilever. Moreover, as the mass of the beam is very small the static beam displacement can be controlled in the wide frequency range. In the experiments, which we describe in this article, we applied the so called active electromagnetic cantilevers. They integrate a conductive loop which, when immersed in the magnetic field and biased with electric current, acts as an electromagnetic deflection actuator. The induced and precisely estimated Lorentz force, which is a function of bias current, cantilever geometry and magnetic field makes the cantilever deflect. Moreover, the probe stiffness can be calibrated with lower uncertainty as in the case of standard thermomechanical analysis. NZ AFM technology required application of a novel control algorithm, called PredPID, in which the cantilever bending caused by a proportional-integral-derivative (PID) block maintaining the constant load force was predicted.


  • Quartz tuning fork mass change sensing for FIB/SEM technology

    by Piotr Kunicki, Magdalena Moczała-Dusanowska, Grzegorz Jóźwiak, Paulina Szymanowska, Tomasz Piasecki, Teodor Gotszalk


  • A method of magnetic field measurement in a scanning electron microscope using a microcantilever magnetometer

    by Maria E. Mognaschi, Bartosz Pruchnik, Karolina Orłowska, Krzysztof Kwoka, Tomasz Piasecki, Piotr Kunicki, Andrzej Sierakowski, Wojciech Majstrzyk, Arkadiusz Podgórni, Paolo di Barba, et al.


  • Open Access

    Sensitivity Improvement to Active Piezoresistive AFM Probes Using Focused Ion Beam Processing

    by Piotr Kunicki, Tihomir Angelov, Tzvetan Ivanov, Teodor Gotszalk, Ivo Rangelow

    This paper presents a comprehensive modeling and experimental verification of active piezoresistive atomic force microscopy (AFM) cantilevers, which are the technology enabling high-resolution and high-speed surface measurements. The mechanical structure of the cantilevers integrating Wheatstone piezoresistive was modified with the use of focused ion beam (FIB) technology in order to increase the deflection sensitivity with minimal influence on structure stiffness and its resonance frequency. The FIB procedure was conducted based on the finite element modeling (FEM) methods. In order to monitor the increase in deflection sensitivity, the active piezoresistive cantilever was deflected using an actuator integrated within, which ensures reliable and precise assessment of the sensor properties. The proposed procedure led to a 2.5 increase in the deflection sensitivity, which was compared with the results of the calibration routine and analytical calculations.


  • Open Access

    Analysis of the electrolytically polished skeletal dentures surfaces using various nano- and microscopic technologies

    by Tomasz Dąbrowa, Wojciech Majstrzyk, Magdalena Tamulewicz, Tomasz Piasecki, Piotr Kunicki, Włodzimierz Więckiewicz, Teodor Gotszalk

    The surface roughness of the dental restorations is significant to the denture plaque adhesion. In this work, we present the complex analysis of the electropolished CoCrW alloy remanium® star (Dentaurum, Germany) samples with laserengraved fiducial marks performed using complementary set of micro- and nanoscopic techniques: optical profilometry (OP), atomic force microscopy (AFM), scanning electron microscopy (SEM) and focused ion beam (FIB) milling. Both mean and RMS roughness of the samples were reduced by electopolishing process, however, the results obtained using OP and AFM exhibited some discrepancies. This was caused by the relatively high local protruding defects developed on the processed surface. The cross-sections of the protrusions were made to analyze the cause of their formation as the EDS elemental content maps revealed that their composition was uniform. We also analyzed the local roughness in the smaller areas free from the defects. In that case, both OP and AFM techniques delivered the same results. Analysis of results showed that various methods used for the surface roughness evaluation have to be used simultaneously to obtain complete and true analysis of the technological CoCrW samples.