CLCheng S. Lee

Cheng S. Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cheng S. Lee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Recent advances in capillary separations for proteomics

    by Jonathan W. Cooper, Yueju Wang, Cheng S. Lee

    The sequencing of several organisms' genomes, including the human's one, has opened the way for the so‐called postgenomic era, which is now routinely coined as “proteomics”. The most basic task in proteomics remains the detection and identification of proteins from a biological sample, and the most traditional way to achieve this goal consists of protein separations performed by two‐dimensional polyacrylamide gel electrophoresis (2‐D PAGE). Still, the 2‐D PAGE‐mass spectrometry (MS) approach remains lacking in proteome coverage (for proteins having extreme isoelectric points or molecular masses as well as for membrane proteins), dynamic range, sensitivity, and throughput. Consequently, considerable efforts have been devoted to the development of non‐gel‐based proteome separation technologies in an effort to alleviate the shortcomings in 2‐D PAGE while reserving the ability to resolve complex protein and peptide mixtures prior to MS analysis. This review focuses on the most recent advances in capillary‐based separation techniques, including capillary liquid chromatography, capillary electrophoresis, and capillary electrokinetic chromatography, and combinations of multiples of these mechanisms, along with the coupling of these techniques to MS. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state‐of‐the‐art integrated proteome effort. Miniaturized and integrated multidimensional peptide/protein separations using microfluidics are further summarized for their potential applications in high‐throughput protein profiling toward biomarker discovery and clinical diagnosis.


  • Integration of capillary isoelectric focusing with capillary reversed-phase liquid chromatography for two-dimensional proteomics separation

    by Jinzhi Chen, Cheng S. Lee, Yufeng Shen, Richard D. Smith, Eric H. Baehrecke

    On-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed using a microinjector as the interface for performing two-dimensional (2-D) protein/peptide separations of complex protein mixtures. The focusing effect of CIEF not only contributes to a high-resolution protein/peptide separation, but also may permit the analysis of low-abundance proteins with a typical concentration factor of 50–100 times. The preparative capabilities of CIEF are much larger than most of capillary-based electrokinetic separation techniques since the entire capillary is initially filled with a solution containing proteins/peptides and carrier ampholytes for the creation of a pH gradient inside the capillary. The focused peptides which have a similar pI are coinjected into the second separation dimension and further resolved by their differences in hydrophobicity. The resolving power of combined CIEF-CRPLC system is demonstrated using the soluble fraction of Drosophila salivary glands taken from a period beginning before steroid-triggered programmed cell death and extending to its completion. The separation mechanisms of CIEF and CRPLC are completely orthogonal and the overall peak capacity is estimated to be around ∼1800 over a run time of less than 8 h. Significant enhancement in the separation peak capacity can be realized by further increasing the number of CIEF fractions and/or slowing the solvent gradient in CRPLC, however, at the expense of overall analysis time. The results of our preliminary studies display significant differences in the separation profiles of peptide samples obtained from salivary glands of animals staged at the 6 and 12 h following puparium formation.


  • On-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis: A two-dimensional separation system for proteomics

    by Deepa Mohan, Cheng S. Lee

    A microdialysis junction is employed as the interface for on-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis in a two-dimensional separation system. Capillary isoelectric focusing not only provides high-resolution separation of tryptic peptides based on their differences in isoelectric point, but also potentially allows the analysis of low-abundance proteins with a typical concentration factor of 50–100 times. Carrier ampholytes, employed for the creation of a pH gradient during focusing, are further utilized as the leading electrolyte in the second separation dimension, transient isotachophoresis-zone electrophoresis. Many peptides which have the same isoelectric point would most likely have different charge-to-mass ratios, and thus different electrophoretic mobilities in zone electrophoresis. Two-dimensional separation of proteolytic peptides is demonstrated using standard proteins, including cytochrome c, ribonuclease A, and carbonic anhydrase II. The maximum peak capacity is estimated to be around ∼1600 and can be significantly increased by simply increasing the capillary column length and manipulating the range of pH gradient in isoelectric focusing. In addition to enhanced separation efficiency and resolution, this two-dimensional electrokinetic separation system permits sensitive and comprehensive analysis of peptide fragments, especially when integrated with electrospray ionization mass spectrometry for peptide/protein identification.


  • On‐line coupling of hollow fiber membranes with electrospray ionization mass spectrometry for continuous affinity selection, concentration and identification of small‐molecule libraries

    by Yun Jiang, Cheng S. Lee

    Combinatorial chemistry has been widely employed in the pharmaceutical industry in the effort towards drug discovery. Rapid and sensitive screening of lead candidates among library compounds has thus imposed significant analytical challenges in recent years. This work involved the development of a continuous affinity capture and concentration system, providing cost‐effective and structural analysis of drug candidates in a flow‐through format. The system combines the strengths of a hollow fiber dialysis membrane of ease and speed of purification and concentration with the specificity of affinity interactions in solution. The complexes between the lead compounds and the affinity binding proteins are separated from other chemical components inside a dialysis hollow fiber as the result of their differences in size. The affinity complexes are further concentrated inside a second dialysis fiber. The concentrated drug candidates are liberated from the binding proteins in a microdialysis junction and can be directly identified using electrospray ionization mass spectrometry. Two model systems, including human serum albumin–warfarin‐related compounds and anti‐phenobarbital antibody–barbiturates, were employed for mechanistic studies of dialysis versus dissociation kinetics and competitive selection of drug candidates according to their binding strengths. Copyright © 2001 John Wiley & Sons, Ltd.