Carina Marconi Germer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carina Marconi Germer has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Leonardo Abdala Elias
Universidade Estadual de Campinas (UNICAMP)
8 shared publications - Dario Farina
Department of Bioengineering, Imperial College London, London, UK
4 shared publications - Alessandro Del Vecchio
Friedrich-Alexander-Universität Erlangen-Nürnberg
3 shared publications - Ellen Pereira Zambalde
Federal University of Uberlândia
2 shared publications A. Del Vecchio
Neuromechanics & Rehabilitation Technology Group, Department of Bioengineering, Faculty of Engineering, Imperial College London, UK
1 shared publicationAlessandro Del Vecchio
Department of Bioengineering, Imperial College London, London, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (10) , 3675-3701
Impact of EMG-based interfaces for hand motor rehabilitation in stroke: A systematic review with evidence gap map and meta-analysis
Electromyography (EMG)-based interventions have been proposed to improve hand/wrist motor recovery after stroke; however, their clinical value remains uncertain, as evidence for their effectiveness is inconsistent. This systematic review with meta-analysis evaluated the impact of different EMG-based rehabilitation approaches compared with non-EMG-based interventions in individuals with stroke. Seven databases were searched from inception to November 17, 2025, in accordance with PRISMA guidelines. Randomized controlled trials comparing EMG-based and non-EMG-based interventions for post-stroke hand or wrist rehabilitation were eligible. Interventions were classified into four categories: EMG-triggered electrical stimulation (EMG-ES), EMG-ES combined with other interventions, EMG-based robotic platforms, and EMG biofeedback combined with other interventions. Risk of bias was assessed using the Cochrane Risk of Bias 2 tool, and certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Meta-analyses were conducted for clinical outcomes classified according to the International Classification of Functioning, Disability and Health (ICF) domains at post-intervention, follow-up Graphical abstract The graphical abstract summarizes the findings of a systematic review and meta-analysis including 38 studies and 1,132 participants. Four types of sEMG-based rehabilitation interfaces were examined across the International Classification of Functioning, Disability and Health (ICF) domains of Body Functions and Structures, Activity, Participation, and Patient-reported outcomes. The symbols indicate the direction of the observed effects and the certainty of the evidence according to GRADE. The results suggest that the effects of sEMG-based rehabilitation vary according to the type of interface. The combination of sEMG-triggered electrical stimulation with other interventions produced the most consistent improvements across the ICF domains. In contrast, sEMG-triggered stimulation alone and sEMG-biofeedback combined with other interventions showed fewer and less consistent benefits. sEMG-based robotic platforms also showed potential, particularly for reducing spasticity. Together, these findings favor the use of combined sEMG-triggered interventions while supporting further investigation of sEMG-based robotic approaches in rehabilitation.
- 28 August 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (10) , 3675-3701
Open AccessImpact of EMG-based interfaces for hand motor rehabilitation in stroke: A systematic review with evidence gap map and meta-analysis
Electromyography (EMG)-based interventions have been proposed to improve hand/wrist motor recovery after stroke; however, their clinical value remains uncertain, as evidence for their effectiveness is inconsistent. This systematic review with meta-analysis evaluated the impact of different EMG-based rehabilitation approaches compared with non-EMG-based interventions in individuals with stroke. Seven databases were searched from inception to November 17, 2025, in accordance with PRISMA guidelines. Randomized controlled trials comparing EMG-based and non-EMG-based interventions for post-stroke hand or wrist rehabilitation were eligible. Interventions were classified into four categories: EMG-triggered electrical stimulation (EMG-ES), EMG-ES combined with other interventions, EMG-based robotic platforms, and EMG biofeedback combined with other interventions. Risk of bias was assessed using the Cochrane Risk of Bias 2 tool, and certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Meta-analyses were conducted for clinical outcomes classified according to the International Classification of Functioning, Disability and Health (ICF) domains at post-intervention, follow-up Graphical abstract The graphical abstract summarizes the findings of a systematic review and meta-analysis including 38 studies and 1,132 participants. Four types of sEMG-based rehabilitation interfaces were examined across the International Classification of Functioning, Disability and Health (ICF) domains of Body Functions and Structures, Activity, Participation, and Patient-reported outcomes. The symbols indicate the direction of the observed effects and the certainty of the evidence according to GRADE. The results suggest that the effects of sEMG-based rehabilitation vary according to the type of interface. The combination of sEMG-triggered electrical stimulation with other interventions produced the most consistent improvements across the ICF domains. In contrast, sEMG-triggered stimulation alone and sEMG-biofeedback combined with other interventions showed fewer and less consistent benefits. sEMG-based robotic platforms also showed potential, particularly for reducing spasticity. Together, these findings favor the use of combined sEMG-triggered interventions while supporting further investigation of sEMG-based robotic approaches in rehabilitation.
- 1 July 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (12) , 3741-3752
Reassessment of isometric muscle force complexity under different contraction intensities, joint angles, and visual feedback conditions
We employed an optimization method for the approximate entropy (ApEn) parameters ( , ) to evaluate the influence of changes in contraction intensity, visual feedback conditions, and joint angles in force ApEn during an isometric force-matching task. Seventeen participants performed an index finger abduction isometric force task in six contraction intensities (5-75% of maximum voluntary contraction, MVC), with and without visual feedback of the force, and in three different metacarpophalangeal (MCP) joint angles. Force variability, complexity (ApEn), and power spectrum density (PSD) were assessed, and a correlation analysis was performed between these variables. The best ApEn ( , ) pair for muscle force analysis was and force standard deviation (SD). Visual feedback influenced the ApEn; however, the comparison between experimental conditions (force intensity and joint angle) was similar. Both the force ApEn and the coefficient of variation (CoV) were reduced as a function of contraction intensity and without visual feedback. Conversely, the force SD and the PSD in the low-frequency band increased with contraction intensity and the absence of visual feedback. The changes in the MCP joint angle affected the MVC values and force CoV, with no significant effect on the force ApEn. The PSD in the low-frequency band (< 5 Hz) showed a strong negative correlation with force ApEn in both visual feedback conditions. ApEn is influenced by force level and visual feedback, and it is strongly correlated with low-frequency force oscillations, which are related to the muscle's common drive.- 1 July 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 125 (12) , 3741-3752
Reassessment of isometric muscle force complexity under different contraction intensities, joint angles, and visual feedback conditions
We employed an optimization method for the approximate entropy (ApEn) parameters ( , ) to evaluate the influence of changes in contraction intensity, visual feedback conditions, and joint angles in force ApEn during an isometric force-matching task. Seventeen participants performed an index finger abduction isometric force task in six contraction intensities (5-75% of maximum voluntary contraction, MVC), with and without visual feedback of the force, and in three different metacarpophalangeal (MCP) joint angles. Force variability, complexity (ApEn), and power spectrum density (PSD) were assessed, and a correlation analysis was performed between these variables. The best ApEn ( , ) pair for muscle force analysis was and force standard deviation (SD). Visual feedback influenced the ApEn; however, the comparison between experimental conditions (force intensity and joint angle) was similar. Both the force ApEn and the coefficient of variation (CoV) were reduced as a function of contraction intensity and without visual feedback. Conversely, the force SD and the PSD in the low-frequency band increased with contraction intensity and the absence of visual feedback. The changes in the MCP joint angle affected the MVC values and force CoV, with no significant effect on the force ApEn. The PSD in the low-frequency band (< 5 Hz) showed a strong negative correlation with force ApEn in both visual feedback conditions. ApEn is influenced by force level and visual feedback, and it is strongly correlated with low-frequency force oscillations, which are related to the muscle's common drive.- 1 October 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 137 (4) , 835-847
Neuroplastic alterations in common synaptic inputs and synergistic motor unit clusters controlling the vastii muscles of individuals with ACL reconstruction
Chronic quadriceps dysfunction is common after anterior cruciate ligament reconstruction (ACLR). We investigated voluntary force control strategies by estimating common inputs to motor neurons innervating the vastii muscles. Our results showed attenuated common inputs to the vastus lateralis and plastic rearrangements in functional clusters of motor neurons modulating knee extension forces in the reconstructed limb. These findings suggest neuroplastic adjustments following ACLR that may occur to fine-tune the control of quadriceps forces.
- 1 October 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 137 (4) , 835-847
Neuroplastic alterations in common synaptic inputs and synergistic motor unit clusters controlling the vastii muscles of individuals with ACL reconstruction
Chronic quadriceps dysfunction is common after anterior cruciate ligament reconstruction (ACLR). We investigated voluntary force control strategies by estimating common inputs to motor neurons innervating the vastii muscles. Our results showed attenuated common inputs to the vastus lateralis and plastic rearrangements in functional clusters of motor neurons modulating knee extension forces in the reconstructed limb. These findings suggest neuroplastic adjustments following ACLR that may occur to fine-tune the control of quadriceps forces.
- Open Access
NeuroNella: A Robust Unsupervised Algorithm for Identification of Neural Activity from Multielectrode Arrays
We introduce NeuroNella, an automated algorithm developed for the identification of neuronal activity from multichannel electrode arrays. In evaluations conducted on recordings from implanted probes in the nervous system of rodents and primates, the algorithm demonstrated remarkable accuracy, showcasing an error rate of less than 1% compared to ground-truth patch clamp signals. Notably, the proposed algorithm handles large datasets efficiently without the necessity of a GPU system. The results highlighted the algorithm’s efficacy in detecting sources in a wide amplitude range and its adaptability in accommodating minor probe shifts. Moreover, the high robustness exhibited by the algorithm in decomposing recordings lasting up to 30 minutes underscores its potential for enabling longitudinal studies and prolonged recording sessions, thus opening new avenues for future brain/machine interface applications.
Open AccessNeuroNella: A Robust Unsupervised Algorithm for Identification of Neural Activity from Multielectrode Arrays
We introduce NeuroNella, an automated algorithm developed for the identification of neuronal activity from multichannel electrode arrays. In evaluations conducted on recordings from implanted probes in the nervous system of rodents and primates, the algorithm demonstrated remarkable accuracy, showcasing an error rate of less than 1% compared to ground-truth patch clamp signals. Notably, the proposed algorithm handles large datasets efficiently without the necessity of a GPU system. The results highlighted the algorithm’s efficacy in detecting sources in a wide amplitude range and its adaptability in accommodating minor probe shifts. Moreover, the high robustness exhibited by the algorithm in decomposing recordings lasting up to 30 minutes underscores its potential for enabling longitudinal studies and prolonged recording sessions, thus opening new avenues for future brain/machine interface applications.
- 4 January 2024
- Published by Springer Nature
- p. 192-201
Assessment of Neuromuscular Function in Patients with Long-Term Symptoms of COVID-19
- 4 January 2024
- Published by Springer Nature
- p. 192-201
Assessment of Neuromuscular Function in Patients with Long-Term Symptoms of COVID-19
- 17 December 2023
- Published by Springer Nature
- p. 266-276
Simplified Computational Model of the Cervical Region for Transcutaneous Spinal Direct Current Stimulation
- 17 December 2023
- Published by Springer Nature
- p. 266-276
Simplified Computational Model of the Cervical Region for Transcutaneous Spinal Direct Current Stimulation
- 1 August 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 131 (2) , 808-820
Surface EMG cross talk quantified at the motor unit population level for muscles of the hand, thigh, and calf
We proposed a new method for the identification and quantification of cross talk at the motor unit level. We show that surface EMG cross talk can lead to physiological misinterpretations of EMG signals such as overestimations in the muscle activity and intermuscular correlation. Cross talk had little influence on the EMG power spectrum, which indicates that conventional temporal filtering cannot minimize cross talk. Spatial filter (single and double differential) effectively reduces but not abolish cross talk.
- 1 August 2021
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 131 (2) , 808-820
Surface EMG cross talk quantified at the motor unit population level for muscles of the hand, thigh, and calf
We proposed a new method for the identification and quantification of cross talk at the motor unit level. We show that surface EMG cross talk can lead to physiological misinterpretations of EMG signals such as overestimations in the muscle activity and intermuscular correlation. Cross talk had little influence on the EMG power spectrum, which indicates that conventional temporal filtering cannot minimize cross talk. Spatial filter (single and double differential) effectively reduces but not abolish cross talk.
- Open Access
- 10 November 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 37 (1) , 95-103
Assessment of force control improvement induced by sinusoidal vibrotactile stimulation in dominant and non-dominant hands
- 10 November 2020
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 37 (1) , 95-103
Open AccessAssessment of force control improvement induced by sinusoidal vibrotactile stimulation in dominant and non-dominant hands
- 31 January 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (1) , 016043
Neurophysiological correlates of force control improvement induced by sinusoidal vibrotactile stimulation
Objective . An optimal level of vibrotactile stimulation has been shown to improve sensorimotor control in healthy and diseased individuals. However, the underlying neurophysiological mechanisms behind the enhanced motor performance caused by vibrotactile stimulation are yet to be fully understood. Therefore, here we aim to evaluate the effect of a cutaneous vibration on the firing behavior of motor units in a condition of improved force steadiness. Approach . Participants performed a visuomotor task, which consisted of low-intensity isometric contractions of the first dorsal interosseous (FDI) muscle, while sinusoidal (175 Hz) vibrotactile stimuli with different intensities were applied to the index finger. High-density surface electromyogram was recorded from the FDI muscle, and a decomposition algorithm was used to extract the motor unit spike trains. Additionally, computer simulations were performed using a multiscale neuromuscular model to provide a potential explanation for the experimental findings. Main results . Experimental outcomes showed that an optimal level of vibration significantly improved force steadiness (estimated as the coefficient of variation of force). The decreased force variability was accompanied by a reduction in the variability of the smoothed cumulative spike train (as an estimation of the neural drive to the muscle), and the proportion of common inputs to the FDI motor nucleus. However, the interspike interval variability did not change significantly with the vibration. A mathematical approach, together with computer simulation results suggested that vibrotactile stimulation would reduce the variance of the common synaptic input to the motor neuron pool, thereby decreasing the low frequency fluctuations of the neural drive to the muscle and force steadiness. Significance . Our results demonstrate that the decreased variability in common input accounts for the enhancement in force control induced by vibrotactile stimulation.
- 31 January 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (1) , 016043
Neurophysiological correlates of force control improvement induced by sinusoidal vibrotactile stimulation
Objective . An optimal level of vibrotactile stimulation has been shown to improve sensorimotor control in healthy and diseased individuals. However, the underlying neurophysiological mechanisms behind the enhanced motor performance caused by vibrotactile stimulation are yet to be fully understood. Therefore, here we aim to evaluate the effect of a cutaneous vibration on the firing behavior of motor units in a condition of improved force steadiness. Approach . Participants performed a visuomotor task, which consisted of low-intensity isometric contractions of the first dorsal interosseous (FDI) muscle, while sinusoidal (175 Hz) vibrotactile stimuli with different intensities were applied to the index finger. High-density surface electromyogram was recorded from the FDI muscle, and a decomposition algorithm was used to extract the motor unit spike trains. Additionally, computer simulations were performed using a multiscale neuromuscular model to provide a potential explanation for the experimental findings. Main results . Experimental outcomes showed that an optimal level of vibration significantly improved force steadiness (estimated as the coefficient of variation of force). The decreased force variability was accompanied by a reduction in the variability of the smoothed cumulative spike train (as an estimation of the neural drive to the muscle), and the proportion of common inputs to the FDI motor nucleus. However, the interspike interval variability did not change significantly with the vibration. A mathematical approach, together with computer simulation results suggested that vibrotactile stimulation would reduce the variance of the common synaptic input to the motor neuron pool, thereby decreasing the low frequency fluctuations of the neural drive to the muscle and force steadiness. Significance . Our results demonstrate that the decreased variability in common input accounts for the enhancement in force control induced by vibrotactile stimulation.
- Open Access
- 30 October 2019
- Published by Wiley in The Journal of Physiology
- Vol. 597 (24) , 5935-5948
The human central nervous system transmits common synaptic inputs to distinct motor neuron pools during non‐synergistic digit actions
Key points: Neural connectivity between distinct motor neuronal modules in the spinal cord is classically studied through electrical stimulation or multi‐muscle EMG recordings. We quantified the strength of correlation in the activity of two distinct populations of motor neurons innervating the thenar and first dorsal interosseous muscles during tasks that required the two hand muscles to exert matched or un‐matched forces in different directions. We show that when the two hand muscles are concurrently activated, synaptic input to the two motor neuron pools is shared across all frequency bandwidths (representing cortical and spinal input) associated with force control. The observed connectivity indicates that motor neuron pools receive common input even when digit actions do not belong to a common behavioural repertoire. Neural connectivity between distinct motor neuronal modules in the spinal cord is classically studied through electrical stimulation or multi‐muscle EMG recordings. Here we quantify the strength of correlation in the activity of two distinct populations of motor neurons innervating the thenar and first dorsal interosseous muscles in humans during voluntary contractions. To remove confounds associated with previous studies, we used a task that required the two hand muscles to exert matched or un‐matched forces in different directions. Despite the force production task consisting of uncommon digit force coordination patterns, we found that synaptic input to motor neurons is shared across all frequency bands, reflecting cortical and spinal inputs associated with force control. The coherence between discharge timings of the two pools of motor neurons was significant at the delta (0–5 Hz), alpha (5–15 Hz) and beta (15–35 Hz) bands (P < 0.05). These results suggest that correlated input to motor neurons of two hand muscles can occur even during tasks not belonging to a common behavioural repertoire and despite lack of common innervation. Moreover, we show that the extraction of activity from motor neurons during voluntary force control removes cross‐talk associated with global EMG recordings, thus allowing direct in vivo interrogation of spinal motor neuron activity.
- 30 October 2019
- Published by Wiley in The Journal of Physiology
- Vol. 597 (24) , 5935-5948
Open AccessThe human central nervous system transmits common synaptic inputs to distinct motor neuron pools during non‐synergistic digit actions
Key points: Neural connectivity between distinct motor neuronal modules in the spinal cord is classically studied through electrical stimulation or multi‐muscle EMG recordings. We quantified the strength of correlation in the activity of two distinct populations of motor neurons innervating the thenar and first dorsal interosseous muscles during tasks that required the two hand muscles to exert matched or un‐matched forces in different directions. We show that when the two hand muscles are concurrently activated, synaptic input to the two motor neuron pools is shared across all frequency bandwidths (representing cortical and spinal input) associated with force control. The observed connectivity indicates that motor neuron pools receive common input even when digit actions do not belong to a common behavioural repertoire. Neural connectivity between distinct motor neuronal modules in the spinal cord is classically studied through electrical stimulation or multi‐muscle EMG recordings. Here we quantify the strength of correlation in the activity of two distinct populations of motor neurons innervating the thenar and first dorsal interosseous muscles in humans during voluntary contractions. To remove confounds associated with previous studies, we used a task that required the two hand muscles to exert matched or un‐matched forces in different directions. Despite the force production task consisting of uncommon digit force coordination patterns, we found that synaptic input to motor neurons is shared across all frequency bands, reflecting cortical and spinal inputs associated with force control. The coherence between discharge timings of the two pools of motor neurons was significant at the delta (0–5 Hz), alpha (5–15 Hz) and beta (15–35 Hz) bands (P < 0.05). These results suggest that correlated input to motor neurons of two hand muscles can occur even during tasks not belonging to a common behavioural repertoire and despite lack of common innervation. Moreover, we show that the extraction of activity from motor neurons during voluntary force control removes cross‐talk associated with global EMG recordings, thus allowing direct in vivo interrogation of spinal motor neuron activity.