Tim Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tim Wu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Bryan Buchholz
Biomedical Engineering and Biotechnology Doctoral Program, University of Massachusetts, Lowell, MA 01854, USA
5 shared publicationsHao Wu
VasoTech, Inc., Lowell, MA 01854, USA
5 shared publicationsStephen McCarthy
Biomedical Engineering and Biotechnology Doctoral Program, University of Massachusetts, Lowell, MA 01854, USA
5 shared publicationsXiaodong Ma
Biomedical Engineering and Biotechnology Doctoral Program, University of Massachusetts, Lowell, MA 01854, USA
5 shared publicationsXingwei Wang
Biomedical Engineering and Biotechnology Doctoral Program, University of Massachusetts, Lowell, MA 01854, USA
5 shared publicationsCesario F. Bianchi
Division of Cardiothoracic Surgery, Brown Medical School, Providence, RI 02903, USA
4 shared publications
Latest Publications
- 27 October 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 11 (6) , 636-645
Long-Term Arterial Remodeling After Bioresorbable Scaffold Implantation 4-Year Follow-up of Quantitative Coronary Angiography, Histology and Optical Coherence Tomography
Purpose Our previous studies have confirmed the safety and efficacy of the novel fully bioresorbable PLLA scaffold (PowerScaffold®) at 12 months implantation. In the present study, the scaffold absorption and coronary vessel remodeling at 4 years were evaluated. Methods After PowerScaffold® were implanted into 13 coronary arteries of 6 miniature pigs, quantitative coronary angiography (QCA) was performed at 15 days and 4 years follow-up to measure the mean lumen diameter (MLD), late lumen loss (LLL), and % stenosis of the coronary arteries. Optical coherence tomography (OCT) was performed to obtain the strut footprints at 4 years before euthanization for histological analysis. In addition, 2 PowerScaffold® were implanted into 2 miniature pigs for 2 years as supplementary data. All stented arteries were dissected and stained with HE, Masson, EVG, and Alcian blue to observe struts, cells, fibrinoid, elastin, and proteoglycans, respectively. Results There were no significant differences in MLD, LLL and % stenosis in stented coronary arteries between 15 days and 4 years by QCA. At 4 years, most strut sites were indiscernible and replaced by extracellular matrix and connective tissue by histology. Both strut/vessel wall interaction and strut coverage were shown 100% by OCT. Conclusion At 4 years, the scaffold struts were completely embedded into vessel wall and mostly replaced by regenerated tissue. There was no sign of in-stent stenosis in all stented arteries.
- 27 October 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 11 (6) , 636-645
Long-Term Arterial Remodeling After Bioresorbable Scaffold Implantation 4-Year Follow-up of Quantitative Coronary Angiography, Histology and Optical Coherence Tomography
Purpose Our previous studies have confirmed the safety and efficacy of the novel fully bioresorbable PLLA scaffold (PowerScaffold®) at 12 months implantation. In the present study, the scaffold absorption and coronary vessel remodeling at 4 years were evaluated. Methods After PowerScaffold® were implanted into 13 coronary arteries of 6 miniature pigs, quantitative coronary angiography (QCA) was performed at 15 days and 4 years follow-up to measure the mean lumen diameter (MLD), late lumen loss (LLL), and % stenosis of the coronary arteries. Optical coherence tomography (OCT) was performed to obtain the strut footprints at 4 years before euthanization for histological analysis. In addition, 2 PowerScaffold® were implanted into 2 miniature pigs for 2 years as supplementary data. All stented arteries were dissected and stained with HE, Masson, EVG, and Alcian blue to observe struts, cells, fibrinoid, elastin, and proteoglycans, respectively. Results There were no significant differences in MLD, LLL and % stenosis in stented coronary arteries between 15 days and 4 years by QCA. At 4 years, most strut sites were indiscernible and replaced by extracellular matrix and connective tissue by histology. Both strut/vessel wall interaction and strut coverage were shown 100% by OCT. Conclusion At 4 years, the scaffold struts were completely embedded into vessel wall and mostly replaced by regenerated tissue. There was no sign of in-stent stenosis in all stented arteries.
- 31 March 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 166 (1) , e91-e95
Trans-Iliac Rat Aorta Stenting: A Novel High Throughput Preclinical Stent Model for Restenosis and Thrombosis
- 31 March 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 166 (1) , e91-e95
Trans-Iliac Rat Aorta Stenting: A Novel High Throughput Preclinical Stent Model for Restenosis and Thrombosis
- 1 March 2011
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 54 (4) , 807-811
Paclitaxel/sirolimus combination coated drug-eluting stent: In vitro and in vivo drug release studies
- 1 March 2011
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 54 (4) , 807-811
Paclitaxel/sirolimus combination coated drug-eluting stent: In vitro and in vivo drug release studies
- 25 January 2011
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 96A (4) , 632-638
In vitro and in vivo degradation of poly(D, L‐lactide‐co‐glycolide)/amorphous calcium phosphate copolymer coated on metal stents
The purpose of this study was to optimize a novel biodegradable polymer for drug eluting stent (DES) applications. Degradation profiles of different poly(D, L‐lactide ‐co‐glycolide)/amorphous calcium phosphate (PLGA/ACP) composites coated on stents were studied both in vitro and in vivo for three months. For the in vitro study, stents were immersed into the phosphate buffered saline (37°C, pH 7.4) with constant shaking. The polymer weight loss was measured weekly and morphological changes were analyzed. The results demonstrated that approximately 60% of polymer was degraded within the three‐month period and there was no significant difference between the different PLGA/ACP composites. However, the composite of 50% PLGA (65/35) with 50% ACP showed a slightly faster degradation rate than other composites. Morphologically, all stent surfaces changed from a micro‐porous before degradation to a corrugated solid micro‐net‐like structure at two months post degradation. Based on in vitro results, 65% PLGA (65/35) with 35% ACP) coated stents were selected and implanted into rat aortas (n = 12) for the in vivo study. Microscopic observation showed that no composite was found on any of the implanted stents at 12 weeks post implantation, which indicated the selected PLGA/ACP composite is desired for DES applications. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A: , 2011.
- 25 January 2011
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 96A (4) , 632-638
In vitro and in vivo degradation of poly(D, L‐lactide‐co‐glycolide)/amorphous calcium phosphate copolymer coated on metal stents
The purpose of this study was to optimize a novel biodegradable polymer for drug eluting stent (DES) applications. Degradation profiles of different poly(D, L‐lactide ‐co‐glycolide)/amorphous calcium phosphate (PLGA/ACP) composites coated on stents were studied both in vitro and in vivo for three months. For the in vitro study, stents were immersed into the phosphate buffered saline (37°C, pH 7.4) with constant shaking. The polymer weight loss was measured weekly and morphological changes were analyzed. The results demonstrated that approximately 60% of polymer was degraded within the three‐month period and there was no significant difference between the different PLGA/ACP composites. However, the composite of 50% PLGA (65/35) with 50% ACP showed a slightly faster degradation rate than other composites. Morphologically, all stent surfaces changed from a micro‐porous before degradation to a corrugated solid micro‐net‐like structure at two months post degradation. Based on in vitro results, 65% PLGA (65/35) with 35% ACP) coated stents were selected and implanted into rat aortas (n = 12) for the in vivo study. Microscopic observation showed that no composite was found on any of the implanted stents at 12 weeks post implantation, which indicated the selected PLGA/ACP composite is desired for DES applications. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A: , 2011.
- 15 July 2010
- Vol. 3 (3) , 192-201
Drug-eluting stents.
Coronary artery disease (CAD) is currently a leading cause of death worldwide. Drug-eluting stents (DESs) have been dominant for the treatment of CAD in the interventional cardiology world owing to their efficacy in significantly reducing restenosis. However, late stage stent thrombosis has become a major concern. Stent platform, drug delivery vehicle and type of drug are three parts of DES and each part affects the performance of the DES. Aiming to provide a clue for the design of future DES, this review focuses on the development of the three major components of DES and their roles in restenosis and thrombosis.
- 15 July 2010
- Vol. 3 (3) , 192-201
Drug-eluting stents.
Coronary artery disease (CAD) is currently a leading cause of death worldwide. Drug-eluting stents (DESs) have been dominant for the treatment of CAD in the interventional cardiology world owing to their efficacy in significantly reducing restenosis. However, late stage stent thrombosis has become a major concern. Stent platform, drug delivery vehicle and type of drug are three parts of DES and each part affects the performance of the DES. Aiming to provide a clue for the design of future DES, this review focuses on the development of the three major components of DES and their roles in restenosis and thrombosis.