Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yiming Liu has a total of 264 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature–strain decoupled electronic skin for human–machine interaction

    by Miao Kong, Shengwei Gao, Jiaxin Zhuang, Zilin Wang, Hao Sun, Panqi Huang, Xue Wang, Yuqing Zhang, Rui Paulo Martins, Pui In Mak, et al.

    Electronic skins are promising for wearable motion monitoring and human–machine interaction owing to their mechanical compliance and conformal contact with human skin. However, in practical environments, piezoresistive strain sensors are intrinsically susceptible to temperature fluctuations, where thermally induced resistance variations are superimposed on strain signals, leading to baseline drift and sensing inaccuracies under practical conditions. Herein, we report a flexible electronic skin platform with real‐time temperature–strain decoupling capabilities. A serpentine strain sensor and a miniaturized thermistor are co‐integrated within a compliant multilayer architecture to simultaneously monitor mechanical deformation and local temperature fluctuations. Through multi‐temperature and multi‐strain calibration, a two‐dimensional regression model is established to quantitatively distinguish the thermal and mechanical contributions to the resistance response. The extracted effective temperature coefficient is further embedded into the acquisition algorithm, enabling real‐time subtraction of temperature‐induced drift. The device exhibits stable temperature and strain responses, fast response/recovery times of 100/200 ms, and reliable performance over 10 000 loading‐unloading cycles. The integrated thermistor maintains strain‐insensitive temperature sensing performance, providing a robust thermal reference under dynamic thermal conditions. The decoupled output effectively suppresses thermally induced baseline drift while preserving the strain‐induced waveform. In human motion monitoring, the E‐skin platform enables stable sensing during bending, stretching, swallowing, and torsional deformations. The decoupled signals are further wirelessly mapped to a four‐degree‐of‐freedom robotic arm, realizing real‐time human–machine interaction. This work provides a physically interpretable and potentially scalable strategy for temperature‐resilient wearable sensing systems operating in dynamic environments. image

  • Open Access

    Flexible wearable human–machine interfaces in biomedical and robotic applications: Bridging electronics, energy, and electrochemical diagnostics

    by Ji Cheng, Yixuan Wang, Xue Wang, Ruiqi Guo, Miao Kong, Anan Ren, Panqi Huang, Shiyuan Liu, Jianwei Li, Yingli Shi, et al.

  • Open Access

    Freestanding Hierarchical‐Porous BCZT Thin Films Enable Efficient Ultrasonic Energy Harvesting in Soft Tissue

    by Zifan Li, Shengwei Gao, Wang Hong, Yuxin Chen, Yiyang Gu, Xu Wang, Chen Tang, Ying Hong, Xuemu Li, Xiaodong Yan, et al.

    Excellent electromechanical properties of piezoceramic thin films facilitate ultrasonic energy harvesting in bioelectronic systems. However, most piezoceramic thin films are fragile and cannot maintain mechanical integrity under deformation, hindering their application in soft tissue coupling. Here, we report a freestanding hierarchical‐porous barium calcium zirconate titanate (BCZT) thin film that combines crack resistance with efficient ultrasonic energy harvesting. The hierarchical‐porous structure, fabricated using polyvinylpyrrolidone (PVP) as a porogen, disperses tensile‐side stress concentration and suppresses crack initiation, while reducing the acoustic‐impedance mismatch with soft tissue and suppressing interfacial ultrasound reflection. The film exhibits reduced permittivity and a high piezoelectric voltage coefficient of g 33 = 97 × 10 −3 V·m/N, resulting in a maximum output power that is approximately 1.5 times that of the dense BCZT thin film under identical ultrasound excitation, evaluated at the respective optimal loads. Owing to its excellent piezoelectric performance, the film also enables reliable detection of weak vibrations, such as radial artery pulse‐wave signals. This work demonstrates a hierarchical‐porous structure for simultaneously improving acoustic coupling, mechanical reliability, and electromechanical transduction in freestanding piezoceramic thin films, highlighting their potential for wearable sensing and implantable ultrasound‐powered bioelectronics.

  • Open Access

    A hemispherical latitude-gradient sensor for closed-loop monitoring and management of scoliosis correction

    by Hehua Zhang, Yuyu Gao, Xinxin He, Haoyu Wang, Jianpeng Zhang, Weibin Zhu, Yuan Guo, Zhenlin Chen, Binbin Zhang, Shengxin Jia, et al.

    Conservative treatment of scoliosis relies on physiotherapy and bracing, yet both approaches lack tools for quantitative, real-time monitoring of corrective forces. Here, we introduce a hemispherical latitude-gradient (HS-LG) sensor as a previously unknown sensing paradigm for soft, curved-body interfaces, using scoliosis as a clinical exemplar. Leveraging a nonzero Gaussian curvature ( K G ≠ 0 ) geometry, the device acts as a spatiotemporal mechanical filter, converting normal pressure into in-plane tensile forces to overcome shear and stress artifacts limiting conventional sensors. Integrated into a wireless platform, the HS-LG sensor enables immediate visualization of spatiotemporal pressure dynamics during therapy. In physiotherapy, bilateral deployment established the first quantitative, closed-loop Schroth regimen. Real-time visual feedback amplified targeted asymmetric breathing by ∼40% and decoupled nontargeted regional effort, transforming subjective instruction into data-driven neuromuscular internalization. In bracing, embedded sensors mapped pressures during daily activities, uncovering highly dynamic, posture-specific force redistributions, including transient pressure gradient reversals during ambulation, that challenge conventional static orthotic paradigms. Furthermore, age ( r = 0.738 ) and body mass index (BMI; r = 0.733 ) emerged as strong predictors of daily wear compliance in the lumbar cohort, while BMI consistently drove interfacial mechanical loading across both spinal regions (lumbar r = 0.61 ; thoracic r = 0.77 ). Together, these results establish the HS-LG sensor design as a versatile, patient-ready platform that links geometry-driven sensing design to personalized, data-informed scoliosis management, while broadly advancing the development of wearable mechanosensing technologies for soft, curved biological surfaces.


  • A Flexible Wireless Passive Platform for Decoupled Electrolyte and Temperature Sensing Toward Heat‑Stress Assessment

    by Yixuan Wang, Yakun Wen, Xinyi Wang, Hao Sun, Haihang Feng, Zhichao Ma, Yanlong Li, Mingyi Chen, Di Chen, Yingli Shi, et al.

    Strenuous exercise and heat exposure can significantly elevate core body temperature and induce profuse sweating, leading to dehydration, electrolyte imbalance, and an increased risk of heat stress. Simultaneous yet decoupled monitoring of thermal and sweating‐related signals is therefore essential for reliable physiological assessment under intense motion. Here, we report a flexible, wireless, and fully passive dual‐mode sensing platform that enables independent detection of sweat accumulation and skin temperature on a single LC resonant architecture. The system integrates a sweat‐responsive electrochemical module and a thermosensitive conductive composite, both inductively coupled to a flexible serpentine coil for battery‐free near‐field interrogation. We establish an orthogonal “frequency–magnitude” decoding strategy: sweat‐induced dielectric changes dominantly drive resonance frequency shifts, while temperature‐dependent resistive losses primarily modulate the reflection coefficient magnitude ( S 11 ). To further enhance robustness against signal coupling and motion artifacts, a machine‐learning‐assisted spectral decoder is introduced, enabling high‐accuracy recognition of joint physiological states. Owing to its lightweight, maintenance‐free operation, and robust performance under vigorous motion, this platform provides a promising strategy for heat‐stress assessment and real‐time physiological monitoring in demanding scenarios such as military training and competitive sports.

  • Advances in olfactory displays for multisensory immersion: principles, applications, and future directions

    by Xue Wang, Miao Kong, Junchen Liao, Ying Hong, Shiyuan Liu, Yiming Liu


  • Self-Driven, Stretchable Drug Delivery Electronics for Acne Treatment

    by Yiming Liu, Xingcan Huang, Qiang Zhang, Wooyoung Park, Jinpei Wang, Jingyou Su, Zhao Zhao, Xue Wang, Miao Kong, Mingxiu Lv, et al.

    Acne is a common skin condition caused by the blockage of hair follicles, which is often associated with adolescents. Beyond physical discomfort and potential scarring, acne can also result in mental health issues including low self-esteem and anxiety. Among all available medical treatments, topical antibiotics are effective for acne treatment due to their rapid action, anti-inflammatory properties, minimal side effects, and accessibility. However, long-term and continuous use of topical antibiotics will result in serious bacterial resistance. Focusing on this issue, we developed a stretchable, self-driven drug delivery system with clindamycin serving as the antibacterial agent, which is powered by a biocompatible, high-performance magnesium-O2 battery. Based on the working principle of ion electrophoresis, the direct current power by the integrated battery is applied onto the self-developed drug layer with clindamycin embedded, realizing controllable delivery of clindamycin along with the ions in the electrolyte to target acne lesions, where the drug delivery rate could be well-adjusted by regulating the power output of the battery. Benefiting from advanced mechanical design and material selection, the entire system is fully stretchable and biocompatible, achieving a stretching rate of up to 100% within the yielding limit. This capability allows it to effectively conform to most human body areas for acne treatment. We further validated the self-driven drug delivery system through in vitro and in vivo experiments, showcasing a feasible acne treatment method that not only extends antibiotic efficacy but also ensures long-term wearability.


  • Top Cited Papers
    Open Access

    A skin-interfaced three-dimensional closed-loop sensing and therapeutic electronic wound bandage

    by Xingcan Huang, Qiang Zhang, Yawen Yang, Lung Chow, Jie Ma, Guoqiang Xu, Fang Guo, Xinxin He, Zhiyuan Li, Guangyao Zhao, et al.

    Chronic wound healing is a complex and long-standing problem, that has been a major and critical clinical concern around the world for years. Recent advances in digital wound dressings open new possibilities for solving the problem. Here, we report a battery-free, fully permeable, skin-adhesive, stretchable electronic wound bandage (iSAFE) for intelligent wound management. This electronic bandage exhibits superior properties in multiple features and can be conformally adhered to the skin wound. In addition, the iSAFE can accurately assess the wound conditions in-situ and thus adaptively perform localized drug release. The results from both in vitro and in vivo studies on animals prove the validity of wound monitoring, wound healing boosting and intelligent closed-loop wound management. Clinical trials on patients across age 18 to 95 with various types of wounds are performed. These results all indicate the unique and universality of the reported technology for wound monitoring and management.


  • Top Cited Papers
    Open Access

    Skin-interfaced multimodal sensing and tactile feedback system as enhanced human-machine interface for closed-loop drone control

    by Chunki Yiu, Yiming Liu, Wooyoung Park, Jian Li, Xingcan Huang, Kuanming Yao, Yuyu Gao, Guangyao Zhao, Hongwei Chu, Jingkun Zhou, et al.

    Unmanned aerial vehicles have undergone substantial development and market growth recently. With research focusing on improving control strategies for better user experience, feedback systems, which are vital for operator awareness of surroundings and flight status, remain underdeveloped. Current bulky manipulators also hinder accuracy and usability. Here, we present an enhanced human-machine interface based on skin-integrated multimodal sensing and feedback devices for closed-loop drone control. This system captures hand gestures for intuitive, rapid, and precise control. An integrated tactile actuator array translates the drone’s posture into two-dimensional tactile information, enhancing the operator’s perception of the flight situation. Integrated obstacle detection and neuromuscular electrical stimulation–based force feedback system enable collision avoidance and flight path correction. This closed-loop system combines intuitive controls and multimodal feedback to reduce training time and cognitive load while improving flight stability, environmental awareness, and the drone’s posture. The use of stretchable electronics also addresses wearability and bulkiness issues in traditional systems, advancing human-machine interface design.


  • Open Access

    Miniaturized, portable gustation interfaces for VR/AR/MR

    by Yiming Liu, Wooyoung Park, Chun Ki Yiu, Xingcan Huang, Shengxin Jia, Yao Chen, Hehua Zhang, Hongting Chen, Pengcheng Wu, Mengge Wu, et al.

    Gustation is one of the five innate sensations for humans, distinguishing from vision, auditory, tactile, and olfaction, as which is a close and chemically induced sense. Despite the fact that a handful of gustation display technologies have been developed, the new technologies still pose significant challenges in miniaturization of the overall size for portability, enriching taste options within a limited working area, supporting natural human–device interaction, and achieving precisely controlled taste feedback. To address these issues, here, we report a set of intelligent and portable lollipop-shaped taste interfacing systems covering from 2 to 9 different taste options for establishing an adjustable taste platform in virtual reality (VR), augmented reality (AR), and mixed reality (MR) environments. Tasteful and food-grade chemicals embedded agarose hydrogels serve as taste sources based on iontophoresis operation principle, with an adjustable feedback intensity and independent operation time by tuning the voltage input. To achieve portability and user-friendly operation, the devices are miniaturized into a gustation interface with 9-channel taste generators in the dimension of 8 cm × 3 cm × 1 cm. To realize both gustation and olfaction feedbacks in Metaverse, an olfaction interface based on 7-channel odor generators is also introduced into the gustation interface system. As a result, the demonstrations of our gustation interface systems in intelligent medical gustation assessment, remote shopping, and mixed reality have proven their advances and great progress in various potential application areas, ranging from human–machine interfaces, to biomedical science, and to entertainment.