Nobuhisa Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nobuhisa Watanabe has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Günter Böhm
Puls-Plasmatechnik PPT
1 shared publicationJohji Fukuyama
Osaka City Institute of Public Health and Environmental Sciences, Tennoji-ku, Osaka City 543-0026, Japan
1 shared publicationMamoru Sakai
Osaka City Institute of Public Health and Environmental Sciences, Tennoji-ku, Osaka City 543-0026, Japan
1 shared publicationOsamu Yamamoto
Osaka City Institute of Public Health and Environmental Sciences, Tennoji-ku, Osaka City 543-0026, Japan
1 shared publicationWolfgang Buscher
Institut für Chemo-und Biosensorik
1 shared publication
Latest Publications
- 1 January 2004
- Published by Elsevier in Waste Management
- Vol. 24 (6) , 623-632
Combustible and incombustible speciation of Cl and S in various components of municipal solid waste
- 1 January 2004
- Published by Elsevier in Waste Management
- Vol. 24 (6) , 623-632
Combustible and incombustible speciation of Cl and S in various components of municipal solid waste
- Open Access
- 25 November 2002
- Published by Springer Nature in Analytical Sciences
- Vol. 18 (11) , 1191-1194
Determination of Fluorine, Chlorine, Bromine and Iodine by Barrier Discharge Radiofrequency Helium Plasma
A determination method of fluorine (F), chlorine (Cl), bromine (Br) and iodine (I) by a barrier discharge radiofrequency helium plasma-atomic emission spectroscopy was developed. A borosilicate glass was wrapped by two copper film electrodes, one of which was earthed, and the other was supplied with a radiofrequency high voltage (98 kHz, 3.2 kV), resulting in a discharge inside of the tube. An optical emission from the discharge tube was introduced to a charge-coupled device(CCD)-spectrometer through an optical fiber, and was monitored in the wavelength range of 730 - 960 nm. The emission lines of F (733.2 nm, 739.9 nm), Cl (833.3 nm, 837.6 nm, 858.6 nm, 894.8 nm, 912.1 nm, etc.), Br (827.2 nm, 882.5 nm, 889.8 nm, 926.5 nm, etc.) and I (905.8 nm) were observed. The linearity of the calibration was determined for F and Cl over the range of 1 - 10 µg, and for Br of 0.1 - 1 µg. The relative emission intensity was in the order of Br > I > Cl > F.
- 25 November 2002
- Published by Springer Nature in Analytical Sciences
- Vol. 18 (11) , 1191-1194
Open AccessDetermination of Fluorine, Chlorine, Bromine and Iodine by Barrier Discharge Radiofrequency Helium Plasma
A determination method of fluorine (F), chlorine (Cl), bromine (Br) and iodine (I) by a barrier discharge radiofrequency helium plasma-atomic emission spectroscopy was developed. A borosilicate glass was wrapped by two copper film electrodes, one of which was earthed, and the other was supplied with a radiofrequency high voltage (98 kHz, 3.2 kV), resulting in a discharge inside of the tube. An optical emission from the discharge tube was introduced to a charge-coupled device(CCD)-spectrometer through an optical fiber, and was monitored in the wavelength range of 730 - 960 nm. The emission lines of F (733.2 nm, 739.9 nm), Cl (833.3 nm, 837.6 nm, 858.6 nm, 894.8 nm, 912.1 nm, etc.), Br (827.2 nm, 882.5 nm, 889.8 nm, 926.5 nm, etc.) and I (905.8 nm) were observed. The linearity of the calibration was determined for F and Cl over the range of 1 - 10 µg, and for Br of 0.1 - 1 µg. The relative emission intensity was in the order of Br > I > Cl > F.