Gengliang Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gengliang Yang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Yi Chen
Beijing National Laboratory for Molecular Sciences, Laboratory of Analytical Chemistry for Life Science, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China. Fax: +86-10-62559373
3 shared publicationsJunfa Yin
Beijing National Laboratory for Molecular Sciences, Laboratory of Analytical Chemistry for Life Science, Institute of Chemistry, Chinese Academy of Sciences, Beijing, China. Fax: +86-10-62559373
2 shared publicationsChunxia He
Chemistry School of Xiangtan University, Xiangtan, China
1 shared publicationHailin Wang
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China
1 shared publicationHaiyan Liu
College of Pharmacy, Hebei University, Baoding 071002, China
1 shared publicationHongying Jia
Beijing National Laboratory for Molecular Sciences, Laboratory of Analytical Chemistry for Life Science, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100080, China
1 shared publication
Latest Publications
- 19 February 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 46 (10) , 1477-1494
Preparation of a Hybrid Cation-Exchange Monolith and Its Application for the Separation of Proteins by High Performance Liquid Chromatography
A hybrid cation-exchange monolith for high performance liquid chromatography (HPLC) was prepared by a one-pot synthesis with reverse-atom transfer radical polymerization, in which sodium bisulfite was used as the inorganic material, methyl methacrylate was used as organic material, 2, 2'-Azobisisobutyronitrile as initiator, and ferric trichloride as the inorganic catalyst. Moreover, sodium bisulfite was used to provide the sulfonic group. The conditions of polymerization were optimized. The chemical groups of the monolith were assayed by Fourier transform infrared spectroscopy; the morphology of monolithic material was investigated by scanning electron microscopy; the pore size distribution was determined by a mercury porosimeter; and the mechanical stability and permeability of the monolith were investigated by the back-pressure drop at several linear velocities. Finally, the monolith was used to separate human serum albumin from human plasma in conjunction with HPLC in 5 min, and the influences of buffer concentration and pH value on the elution of human serum albumin were investigated. In addition, the monolith was applied to separate lysozyme from egg whites in a short time (4 min) and separate a mixture of aromatic compounds.
- 19 February 2013
- Published by Taylor & Francis in Analytical Letters
- Vol. 46 (10) , 1477-1494
Preparation of a Hybrid Cation-Exchange Monolith and Its Application for the Separation of Proteins by High Performance Liquid Chromatography
A hybrid cation-exchange monolith for high performance liquid chromatography (HPLC) was prepared by a one-pot synthesis with reverse-atom transfer radical polymerization, in which sodium bisulfite was used as the inorganic material, methyl methacrylate was used as organic material, 2, 2'-Azobisisobutyronitrile as initiator, and ferric trichloride as the inorganic catalyst. Moreover, sodium bisulfite was used to provide the sulfonic group. The conditions of polymerization were optimized. The chemical groups of the monolith were assayed by Fourier transform infrared spectroscopy; the morphology of monolithic material was investigated by scanning electron microscopy; the pore size distribution was determined by a mercury porosimeter; and the mechanical stability and permeability of the monolith were investigated by the back-pressure drop at several linear velocities. Finally, the monolith was used to separate human serum albumin from human plasma in conjunction with HPLC in 5 min, and the influences of buffer concentration and pH value on the elution of human serum albumin were investigated. In addition, the monolith was applied to separate lysozyme from egg whites in a short time (4 min) and separate a mixture of aromatic compounds.
- 22 March 2009
- Published by Springer Nature in Chromatographia
- Vol. 69 (7-8) , 615-619
On-Line Preconcentration and Analysis of Metribuzin Residues in Corn Fields by Use of a Molecularly Imprinted Polymer
- 22 March 2009
- Published by Springer Nature in Chromatographia
- Vol. 69 (7-8) , 615-619
On-Line Preconcentration and Analysis of Metribuzin Residues in Corn Fields by Use of a Molecularly Imprinted Polymer
- Open Access
- 21 November 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (17) , 2851-2857
On‐line solid‐phase extraction with a monolithic weak cation‐exchange column and simultaneous screening of α1‐adrenergic receptor antagonists in human plasma
An on‐line SPE–HPLC method, using a monolithic poly(glycidyl methacrylate‐co‐ethylene glycol dimethacrylate) (poly(GMA‐EDMA)) based weak cation‐exchange (WCX) column, was developed for simultaneous determination of α1‐adrenergic receptor antagonists in human plasma. The monolithic WCX column was prepared by an in‐situ polymerization protocol and modified stepwise with ethylenediamine and chloroacetic acid. On connecting this column to an injection valve, an on‐line SPE protocol could be established for removal of matrices (mainly proteins and lipids) and preconcentration of four α1‐adrenergic receptor antagonists in human plasma. This method was validated and then used for determination of terazosin, alfuzosin, prazosin, and doxazosin in clinical plasma samples. For all analytes, each calibration curve was found to be linear over a range of 0.005–5 μg/mL (R >0.997), and the limit of detection for each analyte was 0.5 ng/mL. Recovery (> 80%) and precision (RSD <15%) for inter‐ and intra‐day assay were tested at three concentration levels of each analyte and showed acceptable results for quantitative assay. Real samples from hypertensive patients were monitored and results were in agreement with those of the conventional liquid–liquid extraction‐HPLC method. Furthermore, due to its good permeability and biocompatibility, the monolithic WCX sorbent could be reused more than 300 times. The proposed method was especially appropriate for multi‐analyte monitoring in plasma samples.
- 21 November 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (17) , 2851-2857
Open AccessOn‐line solid‐phase extraction with a monolithic weak cation‐exchange column and simultaneous screening of α1‐adrenergic receptor antagonists in human plasma
An on‐line SPE–HPLC method, using a monolithic poly(glycidyl methacrylate‐co‐ethylene glycol dimethacrylate) (poly(GMA‐EDMA)) based weak cation‐exchange (WCX) column, was developed for simultaneous determination of α1‐adrenergic receptor antagonists in human plasma. The monolithic WCX column was prepared by an in‐situ polymerization protocol and modified stepwise with ethylenediamine and chloroacetic acid. On connecting this column to an injection valve, an on‐line SPE protocol could be established for removal of matrices (mainly proteins and lipids) and preconcentration of four α1‐adrenergic receptor antagonists in human plasma. This method was validated and then used for determination of terazosin, alfuzosin, prazosin, and doxazosin in clinical plasma samples. For all analytes, each calibration curve was found to be linear over a range of 0.005–5 μg/mL (R >0.997), and the limit of detection for each analyte was 0.5 ng/mL. Recovery (> 80%) and precision (RSD <15%) for inter‐ and intra‐day assay were tested at three concentration levels of each analyte and showed acceptable results for quantitative assay. Real samples from hypertensive patients were monitored and results were in agreement with those of the conventional liquid–liquid extraction‐HPLC method. Furthermore, due to its good permeability and biocompatibility, the monolithic WCX sorbent could be reused more than 300 times. The proposed method was especially appropriate for multi‐analyte monitoring in plasma samples.
- 1 October 2007
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 44,p. 4614-4616
Macroporous polymer monoliths fabricated by using a metal–organic coordination gel template
We have found a new way, a metal–organic coordination gel template method, to generate polymer monoliths with an essentially macropore size, in which the pores are organized spontaneously into continuous networks; furthermore, the resulting macroporous monoliths have potential applications in high-throughput and high-efficiency separation of proteins.
- 1 October 2007
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 44,p. 4614-4616
Macroporous polymer monoliths fabricated by using a metal–organic coordination gel template
We have found a new way, a metal–organic coordination gel template method, to generate polymer monoliths with an essentially macropore size, in which the pores are organized spontaneously into continuous networks; furthermore, the resulting macroporous monoliths have potential applications in high-throughput and high-efficiency separation of proteins.
- 1 July 2007
- Published by Elsevier in Journal of Chromatography B
- Vol. 854 (1-2) , 85-90
On-line clean-up and screening of oxacillin and cloxacillin in human urine and plasma with a weak ion exchange monolithic column
- 1 July 2007
- Published by Elsevier in Journal of Chromatography B
- Vol. 854 (1-2) , 85-90
On-line clean-up and screening of oxacillin and cloxacillin in human urine and plasma with a weak ion exchange monolithic column
- 2 March 2007
- Published by Elsevier in Journal of Chromatography A
- Vol. 1143 (1-2) , 88-97
Micellar liquid chromatography with dodecyl dimethyl betaine as an in vitro method for prediction of protein-drug binding
- 2 March 2007
- Published by Elsevier in Journal of Chromatography A
- Vol. 1143 (1-2) , 88-97
Micellar liquid chromatography with dodecyl dimethyl betaine as an in vitro method for prediction of protein-drug binding