RIReza Iranpour

Reza Iranpour

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Reza Iranpour has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Online Biochemical Oxygen Demand Monitoring for Wastewater Process Control-Full-Scale Studies at Los Angeles Glendale Wastewater Plant, California

    by Reza Iranpour, Miguel Zermeno

    The main objective of this investigation is to determine whether or not it would be feasible to use the measured values of biochemical oxygen demand (BOD) of wastewater obtained by an online instrument at the Los Angeles/Glendale Water Reclamation Plant (California) for controlling its activated sludge process. This investigation is part of a project to develop online BOD monitoring for process control in the City of Los Angeles wastewater treatment plants. Tests studied the Siepmann und Teutscher GmbH (ISCO‐STIP Inc., Lincoln, Nebraska) BIOX‐1010, which uses a bioreactor containing a culture of microbes from the wastewater to measure soluble BOD in 2 minutes. This rapid approximation to the operation of secondary treatment allows anticipation of system response. Calibration measurements allow the operators to find a conversion factor for the instrument's microprocessor to compute values of BOD that agree well with the standard 5‐day BOD (BOD 5) measurement, despite the differences in the details of the two testing methods. This instrument has recently been used at other wastewater treatment plants, at a number of airports in Europe and the United States to monitor runway runoff, and is also being used on waste streams at an increasing number of food processing plants. A comparison was made between the plant influent BOD values obtained by the BIOX‐1010 online monitor from the end of August, 2000, to late January, 2001, and the individual and average values obtained for the same period using the standard BOD 5, 20°C test, to determine the effectiveness of the Biox‐1010 to identify shock loads and their duration. Individual BOD estimates and averages over periods of overly high biological loads (shock loads) were compared, and the instrument readings were evaluated for their effectiveness in detecting shock loads. The results were highly satisfactory, so the instrument was used to trigger a shock‐load warning alarm since late September, 2000. This allowed flow diversion and temporary storage to prevent process upsets.


  • Single-stage Sequencing Batch Process for Producing Class A Biosolids from AD Effluent at Terminal Island Treatment Plant

    by Huub H.J. Cox, Steve Fan, Reza Iranpour

    Terminal Island Treatment Plant converted its digesters to thermophilic operation with the objective to comply with the U.S. EPA Part 503 Biosolids Rule requirements for Class A biosolids. The following processes were tested: a) single-stage continuous; b) two-stage continuous; c) single-stage sequencing batch. Salmonella sp. were always non-detect in digester outflows (<3 MPN/4 g dry wt), whereas fecal coliform densities were usually below the Class A limit of 1000 MPN/g dry wt. However, the recurrence of fecal coliforms in post-digestion caused non-compliance with the Class A limit at the truck loading facility as the last point of plant control for compliance. After several design modifications of the post-digestion train, operation of the digesters as sequencing batch digesters according to the time-temperature requirement of Alternative 1 of the Part 503 Biosolids Rule achieved compliance for both Salmonella sp. and fecal coliforms at the last point of plant control (truck loading facility).

  • Full‐Scale Class A Biosolids Production by Two‐Stage Continuous‐Batch Thermophilic Anaerobic Digestion at the Hyperion Treatment Plant, Los Angeles, California

    by Reza Iranpour, Huub H. J. Cox, Steve Fan, Varouj Abkian, Traci Minamide, Ray J. Kearney, Roger T. Haug

    The City of Los Angeles Hyperion Treatment Plant (HTP) (California) converted its anaerobic digesters to thermophilic operation to produce Class A biosolids. Phase IV tests demonstrated compliance of a two‐stage, continuous‐batch process with Alternative 1 of U.S. Environmental Protection Agency 40 CFR Part 503 (U.S. EPA, 1993), which defines the time–temperature requirement for batch treatment (T ≥ 56.3°C at 16‐h holding). Fecal coliforms, Salmonella sp., viable helminth ova, and enteric viruses were not detected in biosolids in the postdigestion train, including the truck‐loading facility and the farm for land application as the last points of plant control where compliance is to be demonstrated. The same results were achieved during Phase V tests, after lowering the second‐stage holding temperature to 52.6°C to reduce the elevated methyl mercaptan production that was observed during Phase IV. Hence, the Phase V process complied with Alternative 3 of 40 CFR Part 503. Currently, HTP operates its digesters under the same conditions as tested in Phase V. In 2003, monthly monitoring of the biosolids at the truck‐loading facility and the farm for land application demonstrated consistent compliance with Alternative 3.


  • Evaluation of thermophilic anaerobic digestion processes for full‐scale Class A biosolids disinfection at hyperion treatment plant

    by R. Iranpour, H.H.J. Cox

    This paper describes 5 phases of full‐scale testing at the City of Los Angeles Hyperion Treatment Plant (HTP) for producing Class A biosolids (U.S. EPA Part 503 Biosolids Rule) by thermophilic anaerobic digestion. Phases I and II were tests with a two‐stage continuous‐batch process in a thermophilic battery of six digesters and a designated post‐digestion train that was isolated from mesophilic operations. These tests demonstrated that digester outflow biosolids met the Class A limits for fecal coliforms and Salmonella sp. However, fecal coliform densities sharply increased during post‐digestion. The recurrence was possibly related to a combination of a large drop of the biosolids temperature after the dewatering centrifuges and contamination of thermophilically digested biosolids from mesophilic operations. Phase III was conducted after insulation and electrical heat‐tracing of the post‐digestion train to maintain a biosolids temperature throughout post‐digestion at about the same level as in the digester outflow. Biosolids monitoring at the last points of plant control (silos at Truck Loading Facility and farm for land application) indicated that fecal coliform recurrence was prevented. After completing the conversion of HTP to thermophilic operation, certification tests of Phases IV and V demonstrated Class A compliance of a two‐stage continuous‐batch process under Alternatives 1 and 3 of the Part 503 Biosolids Rule, respectively. HTP received the permit for Class A (indeed exceptional quality) biosolids land application in Kern County, California, in December 2002 under Alternative 3. Since 2003, HTP has consistently complied with the federal and local standards for Class A biosolids, indicating that Class A limits can be met under conditions less stringent than defined by the Alternative 1 time‐temperature requirement for batch treatment. Biotechnol. Bioeng. 2007;97:19–39.


  • Solving fecal coliform growth/reactivation in biosolids during full-scale post-digestion processes

    by R. Iranpour, R. Palacios, H.H.J. Cox, V. Abkian

    Fecal coliform recurrence has been observed at the City of Los Angeles Hyperion Treatment Plant during pilot-scale experiments with a designated thermophilic battery of six anaerobic digesters, while other digesters were still at a mesophilic temperature. Several lab and full-scale experiments indicated the following possible causes of the growth/reactivation of fecal coliforms in post-digestion: a) contamination of thermophilically digested biosolids with mesophilically digested biosolids; b) a large drop in the biosolids temperature between the centrifuges and silos, which could have allowed the reactivation and/or growth of fecal coliforms. These were resolved by the full plant conversion to thermophilic anaerobic digestion and design modifications of the post-digestion train.


  • Short‐term and long‐term effects of increasing temperatures on the stability and the production of volatile sulfur compounds in full‐scale thermophilic anaerobic digesters

    by Reza Iranpour, Huub H.J. Cox, Steve Fan, Varouj Abkian, Ray J. Kearney, Roger T. Haug

    This study compares the effect of a rapid increase of the digester temperature (from 54°C to 58°C in 2 weeks) with a slow increase (from 53.9°C to 57.2°C at a rate of 0.55°C per month) on full‐scale thermophilic anaerobic digestion at Hyperion Treatment Plant. The short‐term test demonstrated that rapidly increasing the digester temperature caused elevated production of volatile sulfur compounds, most notably methyl mercaptan, but volatile solids destruction and methane production were not significantly affected. The increase of the volatile fatty acid to alkalinity ratio from 0.1 to over 0.3 indicated a transient change in digester biochemistry, which was reversed by lowering the temperature. In the long term‐test, a slow increase of digester temperature, the production of hydrogen sulfide increased above temperatures of 56.1°C, but was controlled by increased injection of ferrous chloride. Methyl mercaptan was detected in trace amounts at the highest temperature tested (57.2°C). This test showed insignificant effects on other digestion parameters, although some temperature‐independent changes were observed that could have been seasonal effects over the year that the long‐term test lasted. Thus a slow temperature increase was preferable. This observation contrasts with previous results showing the desirability of a rapid temperature rise to first establish a thermophilic culture when converting from mesophilic operation. Further research is warranted on temperature limits and process changes to optimize thermophilic anaerobic digestion.


  • Literature review of air pollution control biofilters and biotrickling filters for odor and volatile organic compound removal

    by Reza Iranpour, Huub H.J. Cox, Marc A. Deshusses, Edward D. Schroeder

    A literature study was conducted to compare the feasibility of biofilters and biotrickling filters for the treatment of complex odorous waste air containing hydrogen sulfide (H2S), organic reduced sulfur compounds, and chlorinated and nonchlorinated volatile organic compounds (VOCs). About 40 pilot‐plant studies and full‐scale applications at wastewater treatment plants and other facilities were reviewed. Reactor design and pollutant removal efficiencies were summarized in tables for easy reference and for a perspective on the current state of the art, and to allow comparison between different projects. The survey indicated that both biofilters and biotrickling filters are capable of combining a high H2S and odor removal efficiency with VOC removal. Apart from odor abatement, biological treatment therefore holds promise for reducing the overall toxicity and potential carcinogenicity of VOC‐containing odorous waste air from wastewater treatment plants and other facilities. VOC removal efficiencies were in general lower than those of H2S and odor, although concentrations of individual VOC species were relatively low. This indicates that for effective treatment of VOC‐containing odorous waste air, the design and operation should emphasize VOC removal as the rate‐limiting parameter. © 2005 American Institute of Chemical Engineers Environ Prog, 2005


  • Assessment of aeration basin performance efficiency: sampling methods and tank coverage

    by R. Iranpour, A. Magallanes, M. Zermeño, V. Varsh, A. Abrishamchi, M. Stenstrom


  • Management analysis of wastewater capital improvement programs in large cities

    by Reza Iranpour, Michael K Stenstrom, Jiin Jen Lee, David Miller, Massoud Tajrishi, Ahmad Abrishamchi, Edward D Schroeder, George Tchobanoglous